• Title/Summary/Keyword: relative and absolute

Search Result 895, Processing Time 0.025 seconds

Absolute categories and relative categories (절대범주와 상대범주)

  • Kwon, Kyeong-Won
    • English Language & Literature Teaching
    • /
    • v.8 no.2
    • /
    • pp.131-150
    • /
    • 2003
  • The purpose of this paper is to provide two levels of conceptualization of a category such as an absolute category in semantic level and a relative category in pragmatic level on the basis of Aristotelian category theory and prototype category theory. I do not intend to criticize classical category theory and prototype category theory but to show that these two types of category are applied to the different world. Aristotelian categorization is an absolute category because it is based on the possible world called the meta-world and it has an absolute truth value. The members of an absolute category is presented as a set. There is a clear boundary between members and non-members because they are distinguished by the absolute criteria An absolute category is semantic conceptualization. This absolute category is changed into a relative category when it is applied in the real world. A relative category which corresponds to a prototype category is based on the real world called the object world and it has a relative truth value. Here individuals are categorized by the cognition and perception of human beings. A relative category is pragmatic conceptualization. In conclusion, while classical categories which are called absolute categories represent sentence meaning, prototype categories which are called relative categories represent utterance meaning.

  • PDF

Difference between absolute and relative muscle strength according to resistance exercise proficiency

  • Sang-Hyun Lee
    • International journal of advanced smart convergence
    • /
    • v.12 no.2
    • /
    • pp.167-172
    • /
    • 2023
  • In this study, the absolute and relative strength of six upper extremity resistance exercises were measured by classifying resistance exercise experts and non-experts. As a result, the skilled group showed higher absolute and relative muscle strength than the unskilled group in the 6 upper extremity resistance exercises. These results are judged to be the hypertrophy of fast-twith muscles, the mobilization of motor units, and the increase in the speed of nerve conduction while the skilled person consistently performs resistance exercise. Experts use intermuscular coordination efficiently to stably perform the load according to the movement and exercise intensity performed during exercise, whereas the inexperienced person uses relatively large muscle groups rather than efficiently using intermuscular coordination. It is considered that exercise motion and load were performed by mobilizing. In addition, as a result of comparing the absolute and relative muscle strength between the 6 types of upper limb resistance exercises, there was a difference between the 6 types of upper limb resistance exercises in the two groups. It can be judged that greater muscle strength and endurance were created through liver coordination.

Uncertainty Assessment: Relative versus Absolute Point Dose Measurement for Patient Specific Quality Assurance in EBRT

  • Mahmood, Talat;Ibrahim, Mounir;Aqeel, Muhammad
    • Progress in Medical Physics
    • /
    • v.28 no.3
    • /
    • pp.111-121
    • /
    • 2017
  • Verification of dose distribution is an essential part of ensuring the treatment planning system's (TPS) calculated dose will achieve the desired outcome in radiation therapy. Each measurement have uncertainty associated with it. It is desirable to reduce the measurement uncertainty. A best approach is to reduce the uncertainty associated with each step of the process to keep the total uncertainty under acceptable limits. Point dose patient specific quality assurance (QA) is recommended by American Association of Medical Physicists (AAPM) and European Society for Radiotherapy and Oncology (ESTRO) for all the complex radiation therapy treatment techniques. Relative and absolute point dose measurement methods are used to verify the TPS computed dose. Relative and absolute point dose measurement techniques have a number of steps to measure the point dose which includes chamber cross calibration, electrometer reading, chamber calibration coefficient, beam quality correction factor, reference conditions, influences quantities, machine stability, nominal calibration factor (for relative method) and absolute dose calibration of machine. Keeping these parameters in mind, the estimated relative percentage uncertainty associated with the absolute point dose measurement is 2.1% (k=1). On the other hand, the relative percentage uncertainty associated with the relative point dose verification method is estimated to 1.0% (k=1). To compare both point dose measurement methods, 13 head and neck (H&N) IMRT patients were selected. A point dose for each patient was measured with both methods. The average percentage difference between TPS computed dose and measured absolute relative point dose was 1.4% and 1% respectively. The results of this comparative study show that while choosing the relative or absolute point dose measurement technique, both techniques can produce similar results for H&N IMRT treatment plans. There is no statistically significant difference between both point dose verification methods based upon the t-test for comparing two means.

Autonomous Real-time Relative Navigation for Formation Flying Satellites

  • Shim, Sun-Hwa;Park, Sang-Young;Choi, Kyu-Hong
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.1
    • /
    • pp.59-74
    • /
    • 2009
  • Relative navigation system is presented using GPS measurements from a single-channel global positioning system (GPS) simulator. The objective of this study is to provide the real-time inter-satellite relative positions as well as absolute positions for two formation flying satellites in low earth orbit. To improve the navigation performance, the absolute states are estimated using ion-free GRAPHIC (group and phase ionospheric correction) pseudo-ranges and the relative states are determined using double differential carrier-phase data and singled-differential C/A code data based on the extended Kalman filter and the unscented Kalman filter. Furthermore, pseudo-relative dynamic model and modified relative measurement model are developed. This modified EKF method prevents non-linearity of the measurement model from degrading precision by applying linearization about absolute navigation solutions not about the priori estimates. The LAMBDA method also has been used to improve the relative navigation performance by fixing ambiguities to integers for precise relative navigation. The software-based simulation has been performed and the steady state accuracies of 1 m and 6 mm ($1{\sigma}$ of 3-dimensional difference errors) are achieved for the absolute and relative navigation using EKF for a short baseline leader/follower formation. In addition, the navigation performances are compared for the EKF and the UKF for 10 hours simulation, and relative position errors are mm-level for the two filters showing the similar trends.

Real-Time Relative Navigation with Integer Ambiguity

  • Shim, Sun-Hwa;Park, Sang-Young;Choi, Kyu-Hong
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.34.3-34.3
    • /
    • 2008
  • Relative navigation system is presented using measurements from a single-channel global positioning system (GPS) simulator. The objective of this study is to provide real-time relative navigation results as well as absolute navigation results for two formation flying satellites separated about 1km in low earth orbit. To improve the performance, more accurate dynamic model and modified relative measurement model are developed. This modified method prevents non-linearity of the measurement model from degrading precision by applying linearization about the states from absolute navigation algorithm not about a priori states. Furthermore, absolute states are obtained using ion-free GRAPHIC pseudo-ranges and precise relative states are provided using double differential carrier-phase data based on Extended Kalman Filter. The software-based simulation is performed and achieved meter-level precision for absolute navigation and millimeter-level precision for relative navigation. The absolute and relative accuracies at steady state are about 0.77m and 4mm respectively (3D, r.m.s.). In addition, Integer ambiguity algorithm (LAMBDA method) improves simulation performances.

  • PDF

Antecedent of Foreign Direct Investment (FDI): Focusing on the Moderating Effect of Absolute Corruption and Relative Corruption (해외직접투자(FDI)의 결정요인 분석: 절대적 부패 수준과 상대적 부패 수준의 조절 효과를 중심으로)

  • Do-Eui Kim
    • Korea Trade Review
    • /
    • v.46 no.2
    • /
    • pp.337-354
    • /
    • 2021
  • Several previous studies have not been able to derive consistent research results on the impact of the level of corruption in local countries on foreign direct investment. Therefore, in order to suggest that this study should consider the relative level of corruption rather than the level of absolute corruption, 1) first, examine the moderating effect of the absolute level of corruption on the determinants of foreign direct investment, and 2) examine the moderating effect of the relative corruption on the determinants of foreign direct investment. This study collected 9-year data from 2012 to 2020 based on the Corruption Perceptions Index (CPI) published by Transparency International. A total of 549 observations (country-year) from 82 countries were sampled and a generalized estimation equation (GEE) analysis was performed. As a result of empirical analysis, it was found that the moderating effect of absolute corruption did not appear, whereas the moderating effect of relative corruption reversed the negative (-) relationship between cultural distance and foreign direct investment into a positive (+) relationship. Based on these empirical results, this study suggest that Korean companies need to consider the relative level of corruption with Korea instead of the absolute level of corruption of the investee when conducting foreign direct investment.

Hybrid navigation parameter estimation from aerial image sequence (항공영상을 이용한 하이브리드 영상 항법 변수 추출)

  • 심동규;정상용;이도형;박래홍;김린철;이상욱
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.2
    • /
    • pp.146-156
    • /
    • 1998
  • Thispapr proposes hybrid navigation parameter estimation using sequential aerial images. The proposed navigation parameter estimation system is composed of two parts: relative position estimation and absolute position estimation. the relative position estimation recursively computes the current velocity and absolute position estimation. The relative position estimation recursively computes the current velocity and position of an aircraft by accumulating navigation parameters extracted from two succesive aerial images. Simple accumulation of parameter values decreases reliability of the extracted parameters as an aircraft goes on navigating. therefore absolute position estimation is required to compensate for position error generated in the relative position step. The absolute position estimation algorithm combining image matching and digital elevation model(DEM) matching is presented. Computer simulation with real aerial image sequences shows the efficiency of the proposed hybrial algorithm.

  • PDF

Recovery of spectral absolute acceleration and spectral relative velocity from their pseudo-spectral counterparts

  • Papagiannopoulos, George A.;Hatzigeorgiou, George D.;Beskos, Dimitri E.
    • Earthquakes and Structures
    • /
    • v.4 no.5
    • /
    • pp.489-508
    • /
    • 2013
  • Design spectra for damping ratios higher than 5% have several important applications in the design of earthquake-resistant structures. These highly damped spectra are usually derived from a 5%-damped reference pseudo-acceleration spectrum by using a damping modification factor. In cases of high damping, the absolute acceleration and the relative velocity spectra instead of the pseudo-acceleration and the pseudo-velocity spectra should be used. This paper elaborates on the recovery of spectral absolute acceleration and spectral relative velocity from their pseudo-spectral counterparts. This is accomplished with the aid of correction factors obtained through extensive parametric studies, which come out to be functions of period and damping ratio.

Derivation and Verification of the Relative Dynamics Equations for Aerial Refueling (공중재급유를 위한 상대운동방정식 유도 및 검증)

  • Jang, Jieun;Lee, Sangjong;Ryu, Hyuk
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.21 no.4
    • /
    • pp.1-10
    • /
    • 2013
  • This paper addresses the derivation of 6-DOF equation of Tanker and Receiver's aircraft for aerial refueling. The new set of nonlinear equations are derived in terms of the relative translational and rotational motion of receiver aircraft respect to the tanker aircraft body frame. Further the wind effect terms due to the tanker's turbulence are included. The derivation of absolute dynamic equation for tanker aircraft written in the inertial frame is calculated from the relative dynamics equations of receiver. The derived relative and absolute equations are implemented the simulation in the same flight conditions to verify the relative motion and compare the trim results by using the MATLAB/SIMULINK program.

The Effects of Cooperative Learning in the Relative Evaluation (상대평가에서 협동학습이 학습결과에 미치는 영향)

  • Huh, Jun-Young;Park, Sung-Su
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.4 no.1
    • /
    • pp.7-12
    • /
    • 2012
  • There are two ways in general for evaluating the accomplishments used by the universities, one is relative evaluation, the other is absolute evaluation. Recently, Korean universities have had the problem with score inflation due to absolute evaluation. The advantage of relative evaluation compared with absolute evaluation is for us to distinguish one's academic accomplishments from others. However, relative evaluation would lead to over-competition. Through this paper, I tired to analyze how cooperative learning influences the academic accomplishments under relative evaluation. Cooperative learning in the relative evaluation of student accomplishments conducted were divided into three groups. And analyzed a result and following presented about the research which in necessary.

  • PDF