• Title/Summary/Keyword: reinforcement configuration

Search Result 91, Processing Time 0.022 seconds

Clinical and Angiographic Results after Treatment with Combined Clipping and Wrapping Technique for Intracranial Aneurysm

  • Suh, Sang-Jun;Kim, Sang-Chul;Kang, Dong-Gee;Ryu, Kee-Young;Lee, Hyuk-Gee;Cho, Jae-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.4
    • /
    • pp.190-195
    • /
    • 2008
  • Objective : There have been numerous follow-up studies of patients who had ruptured or unruptured intracranial aneurysms treated by wrapping technique using various materials have been reported. Our objective was to ascertain whether our particular wrapping technique using the temporalis muscle provides protection from rebleeding and any aneurysm configuration changes in follow-up studies. Methods : Clinical presentation, the location and shape of the aneurysm, outcomes at discharge and last follow-up, and any aneurysm configuration changes on last angiographic study were analyzed retrospectively in 21 patients. Reinforcement was acquired by clipping the wrapped temporalis muscle. Wrapping and clipping after incomplete clipping was also done. Follow-up loss and non-angiographic follow-up patient groups were excluded in this study. Results : The mean age was 53 years (range 29-67), and 15 patients were female. Among 21 patients, 10 patients had ruptured aneurysms (48%). Aneurysms in 21 patients were located in the anterior circulation. Aneurysm shapes were broad neck form (14 cases), fusiform (1 case), and bleb to adjacent vessel (6 cases). Five patients were treated by clipping the wrapped temporalis, and 16 patients by wrapping after partial clipping. The mean Glasgow coma scale (GCS) at admission was 14.2. The mean Glasgow outcome scale (GOS) at discharge was 4.8, and 18 patients were grade 5. The mean period between initial angiography and last angiography was 18.5 months (range 8-44). Aneurysm size was not increased in any of these patients and configuration also did not change. There was no evidence of rebleeding in any of these treated aneurysms. Conclusion : Our study results show that wrapping technique, using the temporalis muscle and aneurysm clip(s), for intracranial aneurysm treatment provides protection from rebleeding or regrowth.

Implementation of Tone Control Module in Anchor System for Improved Audio Quality

  • Seungwon Lee;Soonchul Kwon;Seunghyun Lee
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.10-21
    • /
    • 2024
  • Recently, audio systems are changing the configuration of conventional sound reinforcement (SR) systems and public address (PA) systems by using audio over IP (AoIP), a technology that can transmit and receive audio signals based on internet protocol (IP). With the advancement of IP technology, AoIP technologies are leading the audio market and various technologies are being released. In particular, audio networks and control hierarchy over peer-to-peer (Anchor) technology based on AoIP is a system that transmits and receives audio signals over a wide bandwidth without an audio mixer, creating a novel paradigm for existing audio system configurations. Anchor technology forms an audio system by connecting audio sources and output equipment with On-site audio center (OAC), a device that can transmit and receive IP. Anchor's receiving OAC is capable of receiving and mixing audio signals transmitted from different IPs, making it possible to configure a novel audio system by replacing the conventional audio mixer. However, Anchor technology does not have the ability to provide audio effects to input devices such as microphones and instruments in the audio system configuration. Due to this, when individual control of each audio source is required, there is a problem of not being able to control the input signal, and it is impossible to individually affect a specific input signal. In this paper, we implemented a tone control module that can individually control the tone of the audio source of the input device using the audio processor core in the audio system based on Anchor technology, tone control for audio sources is possible through a tone control module connected to the transmitting OAC. As a result of the study, we confirmed that OAC receives the signal from the audio source, adjusts the tone and outputs it on the tone control module. Based on this, it was possible to solve problems that occurred in Anchor technology through transmitting OAC and tone control modules. In the future, we hope that the audio system configuration using Anchor technology will become established as the standard for audio equipment.

Experimental Study on Hysteretic Behavior of 100 MPa Ultra High-Strength Concrete Tied Columns (100 MPa 초고강도 콘크리트 띠철근 기둥의 이력거동에 관한 실험적 연구)

  • Kim, Jong-Keun;Shin, Sung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.2 s.92
    • /
    • pp.161-168
    • /
    • 2006
  • An experimental investigation was conducted to examine the hysteretic behaviors of ultra-high strength concrete tied columns. The purpose of this study is to investigate the safety of ultra-high strength concrete columns with 100 MPa compressive strength for the requirement of ACI provisions. Eight 1/3 scaled columns were fabricated to simulate an 1/2 story of actual structural members with the cross section $300{\times}300mm$ and the aspect ratio 4. The main variables are axial load ratio, configurations and volumetric ratios of transverse reinforcement. The results show that the deformability of columns are affected by the configurations and volumetric ratios of transverse reinforcement. Especially, it has been found that the behavior of columns are affected by axial load ratio rather than the amounts and the configurations of transverse reinforcement. Consequently, to secure the ductile behavior of 100 MPa ultra-high strength concrete columns, ACI provisions for the requirement of transverse steel may considered axial load level and the details of transverse reinforcement.

Confinement Range of Transverse Reinforcements for T-shaped Reinforced Concrete Walls (철근콘크리트 T형 벽체의 콘크리트 구속을 위한 횡철근의 배근범위)

  • 하상수;오영훈;최창식;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.1001-1009
    • /
    • 2002
  • The objective of this study is to determine the range of confinement (or the transverse reinforcement of the reinforced concrete structural walls with the T-shaped cross section subjected to cyclic lateral loads. The range of confinement for transverse reinforcement is related to the location of neutral axis and determined by the magnitude and distribution of compressive strain. The compressive strain depends on the ratio of wall cross sectional area to the floor-plan area, the aspect ratio, configuration, the axial load, and the reinforcement ratios. By affection of flange, the neutral axis appears different depending on positive and negative forces and because of this reason, when web and flange are subjected to compressive stress, the range of confinement for the transverse reinforcement of T-shaped walls would shows different result. Therefore this experimental research focused on the structural characteristics of T-shaped walls and suggested the neutral axis depth through comparing the results of this study with sectional analysis.

Load-resisting characteristics for RC Retrofitting Columns under Cyclic Loads (반복하중을 받는 RC 기둥보강부재의 내력특성실험)

  • 김종임;홍남표;윤정배;정일영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.589-596
    • /
    • 1998
  • Experimental studies are investigated for RC column retrofitting under cyclic load. Design considerations are jacketing of steel plate of carbon fiber with epoxy bonding, use of unbonded plate, additional concrete grouting, ratio of additional longitudinal steel reinforcement and longitudinal configuration of additional ties. Investigated results are 1) jacketing and additional reinforcements are effective for strengthening, 2) use of additional grouting is less effective with respect to increased section. Future studies are needed to evaluate the requirements about additional reinforcements for member stress level, 3) bond between original and additional grout concrete.

  • PDF

Flexural Strength and Ductility of High-Strength R/C Columns subjected to Earthquake Loadings (지진하중을 받는 고강도 콘크리트 기둥의 휨강도와 연성)

  • 박관식;황선경;한병찬;성수용;윤현도;정수영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.145-150
    • /
    • 2001
  • With the increase in the use of High-Strength Concrete(HSC) despite the its weakness like brittle characteristic, it is important to improve the performance of HSC columns, nowadays. Therefore, it is common to use higher strength steel in HSC for the purpose of ductility and strength improvement. This experimental study was set up to investigate the inelastic behavior of HSC(700kg/$cm^{2}$) columns subjected to combined axial and repeated lateral loads. Effects of key variables such as the volumetric ratio of transverse reinforcement, tie configuration and tie yield strength are studied in this research program. Test results indicate that inelastic response of HSC columns improve with proper confinement of core concrete. Increasing the amount of transverse reiuorement results in increased ductility.

  • PDF

A Study on the Development of Intelligent Supplementary Feature Designer(ISFD) in Injection Molding (사출성형제품 부형상의 지적 설계에 관한 연구)

  • Gang, Seong-Nam;Heo, Yong-Jeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.8
    • /
    • pp.164-173
    • /
    • 2001
  • The configuration of injection molded part can be classified into primary feature and supplementary feature. Even though supplementary features such as ribs, snap fits and bosses make mold more complicated, which cause the increasement of the mold cost, supplementary features should be attached to primary features because of assembly, reinforcement, moldability and other functional purposes. But it is not easy for novice designers to design them appropriately because of the profound knowledge related to Injection molding. In this paper, the intelligent design tool called ISFD(Intelligent Supplementary Feature Designer) which supplies easy, simple, time and cost-effective design method has been studied and developed. A knowledge-based design system is a new tool which enables the concurrent design and CIM with integrated and balanced design decisions at the initial design stage of injection molding.

  • PDF

Fatigue Properties of reinforcement plate for damage prevention (손상 방지용 보강재의 용접부 피로특성)

  • Kim, Hyeon-Su;Park, Yun-Gi;Hwang, Ju-Hwan;Yun, Jung-Geun
    • Proceedings of the KWS Conference
    • /
    • 2005.11a
    • /
    • pp.91-93
    • /
    • 2005
  • The purpose of this study is to evaluate effects of stiffener configuration welded to the plate on the fatigue strength. Nominal stress and hot spot stress for the stiffened plate under pure bending condition were evaluated using FEA and experiment and fatigue test for each specimen was performed. For S and SD type, the fatigue strength increase with a decrease in the nominal stress and hot spot stress. D type with doubler plate was found to have the lowest value of nominal and hot spot stress for a given condition. However its fatigue strength was smaller than the others.

  • PDF

A Configuration of DLC(Direct Load Control) Using Internet Communication and Load Control Method (인터넷을 이용한 DLC(Direct Load Control)의 구성 및 부하제어기법)

  • Lee, Jae-Kyung;Kim, In-Soo;Kim, Hyeong-Jung;Lee, Seoung-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.60-64
    • /
    • 2001
  • Recent recovery of the Korean economy drives a rapid increase in utility consumption and requires more stable utility supply and maintenance. However, power location security hardship, reinforcement of international environmental regulation and a huge cost of power plant construction have increased the burden laid on the stable supply. In addition, an efficient and flexible load management is required more than any era since an increment of the rate of increase in cooling load is expected. Therefore, according as the necessity of direct load control for cooling load during the summer in Korea was on the rise, direct load control systems by Internet communication method are constructed at five commercial buildings. Based on practical load control, this study proposes various application modes and communication methods prior to extension diffusion of direct load control hereafter.

  • PDF

Effect of laminate configuration on the free vibration/buckling of FG Graphene/PMMA composites

  • Zeverdejani, Mehran Karimi;Beni, Yaghoub Tadi
    • Advances in nano research
    • /
    • v.8 no.2
    • /
    • pp.103-114
    • /
    • 2020
  • In this research, buckling and free vibration of rectangular polymeric laminate reinforced by graphene sheets are investigated. Various patterns are considered for augmentation of each laminate. Critical buckling load is evaluated for different parameters, including boundary conditions, reinforcement pattern, loading regime, and laminate geometric states. Furthermore, vibration analysis is investigated for square laminate. Elastic properties of the composite are calculated using a combination of both molecular dynamics (MD) and the rule of mixture (MR). Kinematics of the plate is approximated based on the first shear deformation theory (FSDT). The current analysis is performed based on the energy method. For the numerical investigation, Ritz method is applied, and for shape functions, Chebyshev polynomials are utilized. It is found that the number of layers is effective on the buckling load and natural frequency of laminates which made from non-uniform layers.