The dynamic characterization of a three-story auxiliary building in a nuclear power plant (NPP) constructed with a monolithic reinforced concrete shear wall is investigated in this study. The shear wall is subjected to a joint-research, round-robin analysis organized by the Korea Atomic Energy Research Institute, South Korea, to predict seismic responses of that auxiliary building in NPP through a shake table test. Five different intensity measures of the base excitation are applied to the shaking table test to get the acceleration responses from the different building locations for one horizontal direction (front-back). Simultaneously to understand the global damage scenario of the structure, a frequency search test is conducted after each excitation. The primary motivation of this study is to develop a nonlinear numerical model considering the multi-layered shell element and compare it with the test result to validate through the modal parameter identification and floor responses. In addition, the acceleration amplification factor is evaluated to judge the dynamic behavior of the shear wall with the existing standard, thus providing theoretical support for engineering practice.
Despite its disadvantages, soft story can reduce the damage to the upper floors by concentrating drift in that specific story provided that large drifts are avoided. Gapped-Inclined Brace (GIB) with reduced P-delta effects and the control of soft story stiffness makes it possible to take advantage of the soft story in buildings and increase their capacity for energy dissipation. OpenSees software is used in this study to validate and modify the GIB model's shortcomings. Also, the analysis method for this element is changed for design. The modified element is evaluated in 3D analysis. Finally, to retrofit an existing building, this element is used. Based on the Iranian seismic code, a six-story reinforced concrete building is modelled and studied with 3D analysis. In this building, the construction shortcomings and elimination of infills on the ground floor cause the formation of a soft story. Results of nonlinear static analysis, nonlinear dynamic, and incremental dynamic analysis using both components of seismic acceleration applied to the structure at different angles and the fragility curves indicate the improvement of the retrofitted structure's performance using the modified element to reach the required performance level following the retrofit code.
해운대 두산 위브 더 제니스는 부산시 해운대구 수영만에 인접한 매립지에 세워지는 건축물로서 현재 지하 터파기 및 일부 기초공사 진행 중인 건축물이다. 타워동의 주 용도는 주거용 건축물로 높이 300m, 층수 80층으로 이루어져 주거용 콘크리트 건축물로서는 동양 최대의 높이를 자랑하고 있다. 타워는 총 3개의 고충타워와 1개의 저층타워로 이루어져 있으며 지하 저층부 길이가 가로폭 230m, 세로폭 200m로 전체가 한 개의 덩어리로 이루어진 구조물이다. 횡력저항 시스템은 중앙의 $700{\sim}800mm$ 두께의 코어벽체가 4방향의 외곽으로 확장되어 있으며 슬래브 외곽주변을 철근콘크리트 기둥을 설치하여 건축적인 요구사항에 부합되면서 횡방향 하중에 아주 효율적으로 저항할 수 있도록 계획되었으며, 풍 진동에 대해서도 아주 만족스러운 결과를 가져다주었다. 슬래브 바닥 시스템은 두께 250mm인 플랫 플레이트를 적용하여 충고의 최소화 및 외주부의 테두리보나 드롭패널을 설치하지 않아 시공성 및 공기단축에 부합되도록 계획되었다. 시공 시 및 준공 후에도 지속적인 상시 모니터링 시스템을 구축하여 계측된 자료를 기준으로 구조물의 안전성과 사용성을 객관적으로 판단하고 검증할 수 있도록 하였다.
본 논문은 전단머리를 갖는 CFT기둥-RC 무량판 접합부에 대한 실물대 실험연구를 요약한 것이다. CFT구조는 여러 가지 구조 및 시공 상의 장점으로 인하여 국내 건설현장에서 상대적으로 짧은 시간에 폭넓게 수용되고 있다. 한편 RC 무량판 구조는 층고절감 및 공기 단축 측면의 장점으로 국내의 지하주차장이나 주거용 건물에 필수적 구조시스템으로 널리 사용되고 있다. 이 두 구조시스템을 조합함으로써 공사기간의 획기적 단축 등 여러 시공 및 구조상의 이점을 극대화할 수 있을 것으로 예상된다. 그러나 CFT기둥-RC 무량판 접합부의 효율적인 디테일은 국내 외적으로 아직 충분히 연구된 바가 없어서 이 분야의 연구가 매우 필요한 실정이다. CFT기둥-RC 무량판 접합부의 구조성능에 영향을 미칠 수 있는 여러 가지 변수를 고려하여 접합상세를 제안하고 실험을 통하여 검증하였다. 실험결과 본 연구에서 제시된 CFT기둥-RC 무량판 접합상세의 펀칭강도는 ACI에서 규정한 RC 무량판 펀칭강도와 동등하거나 상회하는 것을 확인할 수 있었다. 실험결과를 토대로 CFT기둥-RC 무량판의 펀칭전단강도 예측식을 제안하였다.
본 연구에서는 기존 구조물의 면내 보강을 위해 콘크리트 구조물과 보강재를 쉽게 연결할 수 있는 내진 어댑터의 세부 설계 방안을 제안하였다. 제안된 내진 어댑터는 실제 크기의 절반으로 축소된 2층짜리 기둥-보 구조물에서 동적 시뮬레이션을 통해 성능을 테스트하였다. 실험 결과, 내진 어댑터를 사용하여 보강된 시험체는 보강되지 않은 시험체에 비해 에너지 소산 능력이 3.5배 향상되었음을 보여주어, 일반적인 사용 범위 내에서 내진 어댑터가 손상되지 않았음이 확인되어 그 효과를 입증하였다. 이어서 변형 한계(변형 각도 3.3%)까지 하중을 가했을 때, 1층 하부에서 어댑터와 보강재를 연결하는 M10 볼트 중 하나가 파손된 것을 관찰하였다. 이러한 발견을 고려할 때, 실제 상황에서 내진 보강을 적용할 때는 내진 어댑터를 연결하는 볼트와 앵커의 설계에 중점을 둬야 할 것으로 판단되었다.
This paper presents a case study about the damages on the structural elements of a cast in place reinforced concrete (RC) building after a big fire which was able to be controlled after six hours. The fire broke off at the $2^{nd}$ basement floor of the building, which has five basements, one ground, and two normal floors. As a result of intensely stocked ignitable materials, it spread out to the all of the upstairs. In visual inspection, most of the typical fire damages were observed (such as spalling, net-like cracks, crumbled plasters, bared or visible reinforcement). Also, failures of the $2^{nd}$ basement columns were encountered. It has been concluded that the severity failures of the columns at the $2^{nd}$ basement caused utterly deformation of the building, which is responsible for the massive damages on the beam-column connections. All of the observed damages were categorized related to the types and presented separated regarding the floors. Besides to the visual inspection, the numerical analysis was run to verify the observed damaged on the building for columns, beams, and the connection regions. It is concluded from the study that several parameters such as duration of the fire, level of the temperature influence on the damages to the RC building. Also, it is highlighted by the study that if the damaged building is considered on the overall structural system, it is not able to satisfy the minimum service requirements neither gravity loads nor earthquake conditions.
Arslan, M. Hakan;Ceylan, Murat;Kaltakci, Yaspr M.;Ozbay, Yuksel;Gulay, Fatma Gulten
Structural Engineering and Mechanics
/
제27권2호
/
pp.117-134
/
2007
The force (load) reduction factor, R, which is one of the most important parameters in earthquake load calculation, is independent of the dimensions of the structure but is defined on the basis of the load bearing system of the structure as defined in earthquake codes. Significant damages and failures were experienced on prefabricated reinforced concrete structures during the last three major earthquakes in Turkey (Adana 1998, Kocaeli 1999, Duzce 1999) and the experts are still discussing the main reasons of those failures. Most of them agreed that they resulted mainly from the earthquake force reduction factor, R that is incorrectly selected during design processes, in addition to all other detailing errors. Thus this wide spread damages caused by the earthquake to prefabricated structures aroused suspicion about the correctness of the R coefficient recommended in the current Turkish Earthquake Codes (TEC - 98). In this study, an attempt was made for an approximate determination of R coefficient for widely utilized prefabricated structure types (single-floor single-span) with variable dimensions. According to the selecting variable dimensions, 140 sample frames were computed using pushover analysis. The force reduction factor R was calculated by load-displacement curves obtained pushover analysis for each frame. Then, formulated artificial neural network method was trained by using 107 of the 140 sample frames. For the training various algorithms were used. The method was applied and used for the prediction of the R rest 33 frames with about 92% accuracy. The paper also aims at proposing the authorities to change the R coefficient values predicted in TEC - 98 for prefabricated concrete structures.
일반 건축구조물에 적용된 엘리베이터 피트는 기초판의 연속성을 확보하기 위하여 단차부 벽체 및 피트 바닥 두께를 주변기초와 동일한 단면으로 구조설계 및 시공을 하였으나, 이러한 시공은 기초 단차로 인한 터파기 과다 및 콘크리트 등 재료의 물량이 증가하고, 특히 파일기초의 경우 파일두부정리 범위 과다 및 연약지반 노출 시 지반변위가 발생하게 된다. 또한, 단차로 인하여 기초부위의 골조공사를 2회 분할 시공함에 따른 공기지연과 지하수가 많은 지역에서의 골조공사의 어려움으로 인하여 시공성과 품질저하 및 누수 등 많은 문제점이 발생하고 있다. 강재엘리베이터 피트는 기존 철근콘크리트에서 발생하였던 문제점을 개선하여 터파기의 최소화와 골조공사의 단순화 및 경제성을 목적으로 개발되었다. 지하층의 집수정 및 엘리베이터 피트와 같은 지하구체는 통상 오픈 컷 터파기를 통한 재래식 RC공법을 적용하는 것이 보편적이나 최근 지하집수정 및 엘리베이터 피트에 소요되는 별도의 공정을 단축시키고 철근과 콘크리트의 물량을 최소화하여 공사비를 절감하기 위한 강재 집수정 및 강재엘리베이터 피트의 사용이 지속적으로 증가하고 있다. 강재엘리베이터 피트는 지하구체로서 용접부 및 구조체 방식의 성능이 중요하다. 데크만 있는 실험체보다 스터드 볼트 없이 강판과 콘크리트만 있는 실험체가 약 3배 이상의 하중을 지지할 수 있으므로 스터드 볼트가 없더라도 데크(강판)의 골이 형성되어 있어 휨작용 시 강판과 콘크리트의 구속효과가 있어 어느 정도까지의 합성효과는 기대할 수 있는 것을 확인하였다. 다만, 갑작스런 파단이 발생할 수 있으므로, 강판과 콘크리트의 합성효과를 위해 스터드 볼트 배치가 필요함을 확인하였다. 스터드 볼트의 유무에 따라 약 15% 이상의 휨강도 증가를 기대할 수 있을 것이라 예상된다.
인구 및 기술의 변화속도가 빠른 현재 상황에서 장수명주택인증은 건물의 물리적 및 기능적 수명 연장 견인책이다. 장수명주택 인증요건인 가변성과 수리용이성은 인필요소를 구조와 구분하여 교체 및 변경하도록 유도한다. 이러한 방식은 공업화주택의 특징과도 부합하여 설계 및 시공방법의 변화로 두 가지 주택 유형은 함께 활성화될 수 있을 것이다. 본 연구에서는 이러한 특징을 고려하여 OSC공법을 활용한 공동주택 모델이 장수명주택 인증기준을 충족하도록 계획하였다. 이러한 결과로 평면가변성 및 설비배관의 설치방법, 화장실 공사 방법 등을 습식 공법과는 다른 방식을 적용하여 제시하였다. 가변형 평면은 22m2와 46m2의 두 가지 타입 평면을 확장하여 69m2평면을 만드는 세대통합방법 그리고 가변 가능한 건식패널 벽체를 활용하여 69m2평면을 여러 가지로 계획하는 방법을 제안했다. 이러한 가변성은 9m×10.5m 스팬의 강콘크리트 합성구조 및 일체형 슬래브로 SI시스템 중 서포트 부분을 구성하고 비내력 외벽 및 내벽, 배관 등을 인필부분으로 구분하여 건축구성재를 부품화하는 방식으로 만들 수 있다. 이러한 서포트와 인필 분리 만으로도 시공법과 관련된 기준을 상당부분 충족할 수 있다. 현재 인필요소를 교체 용이하게 하는 기술은 탄소저감 등에서 국가에 편익이 증가할 수 있으므로 활성화를 위해 세제혜택 등의 인센티브 도입을 검토할 필요가 있다.
초고층 건설사업의 골조 공사를 대상으로 철근, 형틀 작업의 생산성을 분석하고 타워 크레인(Tower Crane; TC)의 실질적인 가동률을 조사하였다. 코어부의 형틀작업 생산성은 지하 및 지상·저층부(1~7F) 구간에서는 평균 12.0~8.7(㎡/인·일)로, 기준층 구간(8~75F) 으로 진행될수록 11.9~20.7(㎡/인·일)로 생산성이 향상되는 것으로 분석되었다. 코어와 외주부의 기준층 생산성을 비교해보면 코어 생산성이 약 11% 정도 높은 것으로 나타났다. 또한 기준층의 코어부위 철근작업 생산성(평균 1.02 ton/인·일) 대비 외주부(기준층 평균 1.12 ton/인·일)의 생산성은 대략 9.6% 높은 결과가 도출되었다. 또한, TC 세 대의 평균 가동률은 63.49%로 조사되었으며, 비가동일의 원인으로는 우천 6.1%, 강풍 6.1%, 휴무 17.8%, TC 인상작업 5.8%, 기타 고장 및 수리 등이 0.07% 인 것으로 분석되었다. 이러한 연구결과는 향후 초고층 골조 공사의 공정을 계획하고 관리함에 있어 유용한 자료가 될 것으로 기대된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.