• Title/Summary/Keyword: regulations on standard Korean

Search Result 471, Processing Time 0.037 seconds

A Review on the Performance Criteria of Equipment Required for Asbestos Removal (석면 해체.제거 작업에서 사용되는 장비의 성능 기준에 관한 고찰)

  • Lee, Naroo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.212-221
    • /
    • 2013
  • Objectives: Asbestos fibers are accumulated in negative pressure unit (NPU) or vacuum cleaner in asbestos removal. Failure of operation or poor use performance of the NPU or vacuum cleaner causes asbestos fibers to spread in the air. Asbestos contractors should have an NPU fitted with a HEPA , vacuum cleaner, decontamination area, respirators, wetting equipment, and differential pressure manometer to register with the Ministry of Employment and Labor. There should be performance criteria of equipment used in asbestos removal. But there are none such criteria used in asbestos removal. This study was performed to investigate international or national performance criteria of equipment used in asbestos removal. Methods: Regulations, approved code of practice, guidance and national standards of the UK, USA and Korea were reviewed. A survey was done to investigate the requirements for equipment used in asbestos removal in Korea. Results: Air flow of NPUs used in Korea usually covers from$500m^3/h$ to over $3000m^3/h$. Some requirements for NPUs used in Korea were missing compared to the requirements of British standards for NPUs. All NPUs have different missing requirements. The UK also has separate British standard for leak tests for NPUs. Highly hazardous class vacuum cleaners should be used in asbestos removal in the UK. It has national standards on the operation of vacuum cleaners used in asbestos removal. There is only a certification system for less than 2.5kw rated voltage vacuum cleaners for home use in Korea. Powered (-assisted) respirators with mask are recommended in asbestos removal. Type 5 coveralls should be used in asbestos removal in the UK. There are international standards for requirements and leak tests of type 5 coveralls. A manometer for measuring differential pressure is needed in asbestos removal. The manometer's measuring range should cover less than ${\pm}125$ Pa and the gradation of manometer should be less than 2.5 Pa. The definition of decontamination area should be corrected. Installation of airlock and minimum area should be considered in decontamination area. Conclusions: Equipment should be used in asbestos removal proper performance and no leaks. There should be a certification system for equipment used in asbestos removal. This study can help to a certification system for equipment used in asbestos removal in Korea.

A Study on the Residual Strength of the Carbon Steel pipe using in Fuel Gas (연료가스 배관용 탄소강관의 잔존강도에 대한 연구)

  • Yim, Sang-Sik;Kim, Ji-sun;Ryu, Young-don;Lee, Jin-Han
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.112-117
    • /
    • 2016
  • The standard(KS D 3631) should be obey for using fuel gas pipe in Korea and a carbon steel pipe is coated with synthetic resine for protecting the corrosion. The coating is just performed for anti-corrosion, and actual strength of pipe is given by the carbon steel pipe when the fuel gas is transported. When the flaws are occurred in the steel pipe, the estimation method which is used for residual strength is necessary. But the suitable method is not exist for applying the fuel gas pipe. Eventually, the residual strength is estimated by overseas regulation such as ASME B31G or DNV RP F101. But the method based on the relative regulations are not sufficiently valid and it can not estimate the 85% over even. Therefore, the test was performed for validation with pipe specimen. The specimen was made with artificial flaw. The test results showed the certain differences according to flaw depth and DNV RP F101 is suitable to estimate the residual strength in Korea. The results in this paper contain in case of the severe flaw depth and suitable mode for Korea, so the result can be expected as valuable and widely used in various field.

The Effects of Inland Pollution Sources around the Port of Jeokyang and Jangpo after Rainfall Events on Bacteriological Water Quality in the Changseon Area, Korea (강우에 따른 적양항과 장포항 육상오염원이 창선해역에 미치는 세균학적 영향평가)

  • Ha, Kwang Soo;Yoo, Hyun Duk;Shim, Kil Bo;Kim, Ji Hoe;Lee, Tae Seek;Kim, Poong Ho;Lee, Hee Jung;Yu, Hong Sik
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.46 no.2
    • /
    • pp.160-167
    • /
    • 2013
  • The influences of inland pollution sources nearJeokyang and Jangpoports following rainfall events on the bacteriological water quality and safety of commercial shellfish were investigated in the Changseon area, Korea. Stream flow rates exhibited 1.9- to 5.7-fold increases after rainfall events and then fell to 68~81% of that level after 24 h. The calculated impact area of inland pollution sources was 0.47 $km^2$ in the Jeokyangport area and 0.27 $km^2$ in the Jangpoport area at 24 h following 11 mm of rainfall. When the flow rate of inland pollution increased, the level of male-specific bacteriophage (MSB) decreased, and no MSB could be detected in seawater samples, whereas 30 PFU/100 g was detected in shellfish samples. Fecal coliform levels in seawater and shellfish samples did not exceed their respective tolerance levels (4.5 MPN/100 mL) and 130 MPN/100 g, respectively and thus complied with the standard for approved shellfish growing area. The sanitary conditions of areas adjacent to Jeokyang and Jangpoports under conditions of rainfall below 29 mm met the criteria for approved growing area under the United States National Shellfish Sanitation Program and the EC Regulations.

Some Statistical Considerations on 2×k Crossover Designs for Bioequivalence Trial (생물학적 동등성 시험을 위한 2×k 교차설계법의 통계적 고려)

  • Noh, So-Young;Park, Sang-Gue
    • The Korean Journal of Applied Statistics
    • /
    • v.26 no.4
    • /
    • pp.675-686
    • /
    • 2013
  • The Korea Food and Drug Administration(KFDA) recommends the use of a $2{\times}2$ crossover design to assess the bioequivalence of generic drugs. However, a standard $2{\times}2$ crossover design for bioequivalence trials is often considered problematic due to ethical and economic issues as highly variable drugs are usually required by large numbers of subjects when designing the trial. To overcome this problem a $2{\times}4$ crossover design has been a recommended option as per US regulations; in addition, a $2{\times}3$ crossover design has also recently drawn special attention as an efficient alternative. The current KFDA regulation requires an ANOVA table for every bioequivalence study; however, ANOVA tables of $2{\times}4$ and $2{\times}3$ crossover designs have never been published in the literature. This study shows the derivation of tables of analysis of variance for a $2{\times}4$ cross-over design and a $2{\times}3$ cross-over design. We also suggest a sample size formulas for $2{\times}2$, $2{\times}4$ and $2{\times}3$ crossover designs to provide information on the selection of efficient designs for highly variable drugs.

Effect of Pectinase Treatment on the Extraction Yield Improvement from Rubus coreanus Juice and Physicochemical Characteristics during Alcohol Fermentation (Pectinase 처리가 복분자 과즙의 추출 수율 향상과 알코올 발효 중 이화학적 특성에 미치는 영향)

  • Jeong, Eun-Jeong;Kim, Hyeong-Eun;Shin, Dong-Hwa;Kim, Yong-Suk
    • Food Science and Preservation
    • /
    • v.14 no.6
    • /
    • pp.702-708
    • /
    • 2007
  • The effects of pectinase treatment and other processing conditions on juice yield from Rubus coreanus, and physicochemical changes during alcohol fermentation, were investigated. The yield from R. coreanus increased by 8.60% with Pectinex 100L treatment (500 ppm, 30 min) compared to a control group. The soluble solid content in the group fermented at $24^{\circ}Brix$ by addition of sucrose (24B-group), and the group fermented at $8^{\circ}Brix$ by addition of 16% sucrose after 4 days of fermentation (8B-group) decreased to $8.2{\sim}8.3$ and $7.7{\sim}8.0%$ after 10 days of fermentation, respectively, and no significant differences were observed with Pectinex 100L treatment. Initial titratable acidity in the enzyme treatment was slightly higher ($1.18{\sim}1.22%$) than for the control group (1.02%). The initial $L^*$ and $b^*$ values of R. coreanus juice decreased with enzyme treatment, and the $a^*$ value increased, but the color difference (${\Delta}E$) between the control and enzyme treatment gradually decreased with fermentation time. The ethanol contents in the 24B-group and the 8B-group were $16.01{\sim}16.22%$ and $13.29{\sim}13.52%$, respectively, after 10 days of fermentation. The methanol contents in the enzyme treatment and the control were $0.359{\sim}0.404$ and $0.520{\sim}0.604$ mg/mL, respectively, and within standard regulations (1 mg/mL).

Changes in the Training Conditions of Residents by Enforcement of Medical Residents Act (전공의법 시행에 따른 전공의 수련환경 변화)

  • Oh, Su-Hyun;Kim, Jin-Suk
    • Journal of Digital Convergence
    • /
    • v.17 no.12
    • /
    • pp.427-434
    • /
    • 2019
  • The Medical Residents Act was enacted in December 2016 to protect the rights of residents, and to ensuring the safety of patients, and nurturing good medical human resources. This study analyzed the changes of training conditions according to the enforcement of The Medical Residents Act by comparing the results of two surveys conducted in 2015(1,793 Residents) and 2017(1,768 Residents). As a result, Residents worked over 80 hours per week on average('15=92.4h, '17=87.3h) and they worked twice as many times as 36 hours('15=89.4h, '17=70.1h). Female residents' leave before and after childbirth('15=78.5day, '17=82.2day), Preparation of Standard training contract('15=19.3%, '17=40.8%), Delivery of training contract('15=12.4%, '17=36.1%) did not comply with the regulations. The training conditions of the residents is directly related to the safety of patients and the public's health. National support is needed for the support of substitute workforces, fair training evaluation conditions and incentives based on the evaluation results, labor costs for residents and supervising medical specialists, and the cost of making training programs.

Power Generation Cost Comparison of Nuclear and Coal Power Plants in Year 2001 under Future Korean Environmental Regulations -Sensitivity and Uncertainty Analysis- (미래의 한국의 환경규제여건에 따른 2001년도의 원자력과 석탄화력 발전단가비교 -민감도와 불확실도 분석-)

  • Lee, Byong-Whi;Oh, Sung-Ho
    • Nuclear Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.18-31
    • /
    • 1989
  • To analyze the impact of air pollution control on electricity generation cost, a computer program was developed. POGEN calculates levelized discounted power generation cost including additional air pollution control cost for coal power plant. Pollution subprogram calculates total capital and variable costs using governing equations for flue gas control. The costs are used as additional input for levelized discounted power generation cost subprogram. Pollution output for Rue Gas Desulphurization direct cost was verified using published cost data of well experienced industrialized countries. The power generation costs for the year 2001 were estimated by POGEN for three different regulatory scenarios imposed on coal power plant, and by levelized discounted power generation cost subprogram for nuclear power. Because of uncertainty expected in input variables for future plants, sensitivity and uncertainty analysis were made to check the importance and uncertainty propagation of the input variables using Latin Hypercube Sampling and Multiple Least Square method. Most sensitive parameter for levelized discounted power generation cost is discount rate for both nuclear and coal. The control cost for flue gas alone reaches additional 9-11 mills/kWh with standard deviation less than 1.3 mills/kWh. This cost will be nearly 20% of power generation cost and 40% of one GW capacity coal power plant investment cost. With 90% confidence, the generation cost of nuclear power plant will be 32.6-51.9 mills/kWh, and for the coal power plant it will be 45.5-50.5 mills/kWh. Nuclear is favorable with 95% confidence under stringent future regulatory requirement in Korea.

  • PDF

Study on effect of fuel property change on vehicle important parts and exhaust gas (연료 물성 변화가 자동차 주요부품 및 배출가스에 미치는 영향 연구)

  • Lee, Jung-Cheon;Kim, Sung-Woo;Lee, Min-Ho;Kim, Ki-Ho;Park, An-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.866-873
    • /
    • 2017
  • Exhaust regulations of automobile are being reinforced increasingly as environmental problems issues came to the fore by industrial development. However, it is known that the exhaust emission is not only influenced by the system of automobile but also the fuel properties. In particular, high-performance engines have required high-performance fuels with high lubricity as CRDI engines(diesel engine) have been developed and commercialized. This paper have examined that the fuel property variations affect a major parts and an exhaust gas of automobile. It was confirmed that the high pressure pump, the injector and the DPF(diesel particulate filter) were damaged and fuel efficiency was get worse due to use the fuel of lacking lubricity property($651{\mu}m$/quality standard: less in $400{\mu}m$). In addition, through an iron component was detected in the broken DPF, it was estimated that the breakage of the DPF was caused by the excessive exhaust of the particulate matter due to the iron component of the fuel.

Experimental Study on Reduction of Particulate Matter and Sulfur Dioxide Using Wet Electrostatic Precipitator (습식전기집진기를 활용한 입자상 물질 및 황산화물 저감 성능에 관한 실험적 연구)

  • Kim, Jong-Lib;Oh, Won-Chul;Lee, Won-Ju;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.898-904
    • /
    • 2021
  • This experimental study aims to investigate the use of a wet electrostatic precipitator as a post-treatment device to satisfy the strict emission regulations for sulfur oxides and particulate matter (PM). The inlet/outlet of a wet electrostatic precipitator was installed in a funnel using a marine four-stroke diesel engine (STX-MAN B&W) consuming marine heavy fuel oil (HFO) with a sulfur content of about 2.1%. Measurements were then obtained at the outlet of the wet electrostatic precipitator; an optical measuring instrument (OPA-102), and the weight concentration measurement method (Method 5 Isokinetic Train) were used for the PM measurements and the Fourier transform infrared (FT-IR; DX-4000) approach was used for the sulfur oxide measurements. The experimenst were conducted by varying the engine load from 50%, to 75% and 100%; it was noted that the PM reduction efficiency was a high at about 94 to 98% under all load conditions. Additionally, during the process of lowering the exhaust gas temperature in the quenching zone of the wet electrostatic precipitator, the sulfur dioxide (SO2) values reduced because of the cleaning water, and the reduction rate was confirmed to be 55% to 81% depending on the engine load.

A Study on the Establishment of Allowable Criteria for Sailing Ships at Offshore Wind Farms (해상풍력발전단지해역 선박 통항 허용기준 설정에 관한 연구)

  • Ohn, Sung-Wook;Lee, Chang-Hyun;Kim, Cheol-Seong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.7
    • /
    • pp.841-847
    • /
    • 2018
  • Since global energy consumption and demand for energy have dramatically risen, a focus on environmental problems and sustainability has become more important. Clean and renewable energy sources such as offshore wind power generation have received attention among new renewable energy options as alternative energy resources. Due to maintenance and operational perspectives, offshore wind farms have been planned for installation in many coastal waters. However, development of offshore wind farms faces interference from existing maritime traffic along the planned areas. In order to safely and effectively govern marine traffic in the vicinity of wind farms and inner areas, standard criteria are suggested to allow vessels to sail the internal waters of offshore wind farm areas. Therefore, the purpose of this study is to establish allowable criteria for sailing vessels and safety zones for offshore wind farms by investigating the local regulations of various offshore wind farm cases overseas. The commended inner safety zone of wind farms is proposed to be a distance of 150 % of the rotation diameter of the wind turbine rotor and a distance of 200 m from the outer wind turbine for the outer safety zone. Besides this, the allowable criteria for sailing vessels within a wind farm is proposed to have an air draft of 14.47 m south-west wind farm sea areas for a minimum margin to avoid hull contact through evaluation of the tide and height of a wind turbine. further studies will be needed to establish vessel sailing criteria among adjacent offshore wind farms as well as vessel sailing criteria within a single offshore wind farm.