• Title/Summary/Keyword: region contrast

Search Result 858, Processing Time 0.033 seconds

Preprocessing for High Quality Real-time Imaging Systems by Low-light Stretch Algorithm

  • Ngo, Dat;Kang, Bongsoon
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.585-589
    • /
    • 2018
  • Consumer demand for high quality image/video services led to growing trend in image quality enhancement study. Therefore, recent years was a period of substantial progress in this research field. Through careful observation of the image quality after processing by image enhancement algorithms, we perceived that the dark region in the image usually suffered loss of contrast to a certain extent. In this paper, the low-light stretch preprocessing algorithm is, hence, proposed to resolve the aforementioned issue. The proposed approach is evaluated qualitatively and quantitatively against the well-known histogram equalization and Photoshop curve adjustment. The evaluation results validate the efficiency and superiority of the low-light stretch over the benchmarking methods. In addition, we also propose the 255MHz-capable hardware implementation to ease the process of incorporating low-light stretch into real-time imaging systems, such as aerial surveillance and monitoring with drones and driving aiding systems.

Intradural Retroclival Chordoma

  • Choo, Yeon-Soo;Joo, Sang-Wook;Noh, Seung-Jin;Lee, Sun-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.2
    • /
    • pp.152-155
    • /
    • 2009
  • A 43-year-old woman presented with dizziness, ataxia and right hearing difficulty. Her magnetic resonance images demonstrated an inhomogeneously contrast-enhanced large tumor growing into right cavernous sinus and Meckel's cave located totally within intradural retroclival region. She underwent retromastoid suboccipital craniotomy to resect the tumor mass and adjuvant gamma knife radiosurgery for remnant tumor at 1 month after operation. Adjuvant radiosurgery after surgical excision seems to be effective for the treatment of intradural extraosseous chordomas.

Extraction and Shape Description of Feature Region on Ocular Fundus Fluorescein Angiogram (형광 안저화상에 관한 특수 영역의 유출 및 모양)

  • Go, Chang-Rim;Ha, Yeong-Ho;Kim, Su-Jung
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.81-86
    • /
    • 1987
  • An image feature extraction method for the low contrast fluoresceln angiogram in dlabetes was studied. To obtain effective image segmentation, an adaptive local difference image is generated and relaxation process are applied to this difference Image. By the use of distance transformed data with segmented image, shape and location of feature regions were obtained. It was shown that the location and shape descriptions of Impaired blood vessel networks and retinal regions are can he utilized for the diagnosis of diabetes and other disease.

  • PDF

CCD-based EPID and Frame Averaging Technique

  • Kim, Ho-Kyung;Cho, Gyu-Seong;Chung, Yong-Hyun;Ahn, Seong-Kyu;Lee, Hyung-Koo;Kim, Hoi-Nam;Yoon, Sei-Chul
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.297-298
    • /
    • 1998
  • Prototype portal imaging device (EPID) based on CCD camera, which has a $20\times20cm^2$ field of view (FOV), has been developed and then tested by acquiring phantom images for 6 MV x-ray beam. While, among the captured images, each frame suffered notorious quantum noise, the frame averaging largely enhanced the image quality against quantum noise. Over 60 frames averaging, the signal-to-noise ratio (SNR) was increased by $\sim20$ times and contrast was increased about 2 times in the skull-region of the acquired head-phantom image.

  • PDF

Isolated Traumatic Injury of the Pancreatic Head: A Case Report

  • Kim, Dong Hun
    • Journal of Trauma and Injury
    • /
    • v.29 no.2
    • /
    • pp.51-55
    • /
    • 2016
  • Isolated injury to the pancreas after abdominal trauma is uncommon, and a delay in diagnosis and treatment can increase the morbidity and mortality. Therapeutic decisions with respect to pancreatic trauma are usually made based on the site of injury and the status of the pancreatic ductal system. In this report, we describe the surgical management of pancreatic head transection as an isolated injury following blunt abdominal trauma. A 55-year-old man presented with epigastric pain that radiated to the back. Abdominal computed tomography revealed a hematoma in the pancreatic head and upstream dilatation of the main pancreatic duct. Endoscopic retrograde cholangiopancreatography showed complete disruption of and contrast leakage from the main pancreatic duct in the pancreatic head region with a nonenhanced upstream duct. Emergency pancreaticoduodenectomy was successfully performed, and the patient was discharged on postoperative day 9 without any complications.

MAXIMUM POWER ENTROPY METHOD FOR LOW CONTRAST IMAGES

  • CHAE JONG-CHUL;YUN HONG SIK
    • Journal of The Korean Astronomical Society
    • /
    • v.27 no.2
    • /
    • pp.191-201
    • /
    • 1994
  • We propose to use the entropy of power spectra defined in the frequency domain for the deconvolution of extended images. Spatial correlations requisite for extended sources may be insured by increasing the role of power entropy because the power is just a representation of spatial correlations in the frequency domain. We have derived a semi-analytical solution which is found to severely reduce computing time compared with other iteration schemes. Even though the solution is very similar to the well-known Wiener filter, the regularizingng term in the new expression is so insensitive to the noise characteristics as to assure a stable solution. Applications have been made to the IRAS $60{\mu}m\;and\;100{\mu}m$ images of the dark cloud B34 and the optical CCD image of a solar active region containing a circular sunspot and a small pore.

  • PDF

Focal form of acquired myasthenia gravis with megaesophagus in a Yorkshire terrier dog

  • Hahn, Tae-Yeon;Kang, Min-Hee;Eom, Ki-Dong;Park, Hee-Myung
    • Korean Journal of Veterinary Research
    • /
    • v.54 no.1
    • /
    • pp.59-62
    • /
    • 2014
  • A 12-year-old, castrated male Yorkshire terrier dog presented with frequent regurgitations that had begun 45 days earlier and become more progressive. Radiographs revealed an air-trap region behind the cranial esophageal sphincter muscle in the esophagus and esophagographies with barium contrast showed mild esophageal dilation with decreased motility. Esophageal motility increased within 5 min of neostigmine methylsulfate administration and acetylcholine receptor antibodies titer increased to beyond the normal range. Based on these findings, acquired myasthenia gravis with focal form was diagnosed, making this the first such case diagnosed by an acetylcholine receptor antibody test in Korea.

Nonlinear evolution of the relativistic Weibel instability driven by anisotropic temperature

  • Kaang, Helen H.;Mo, Chang
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.34.2-34.2
    • /
    • 2009
  • The relativistic Weibel instability has drawn attention as a main mechanism of the magnetic generation in the core of galaxies or in the formation of universe. The Weibel instability is not yet fully understood in the relativistic region. We investigated nonlinear saturation and decay of the relativistic Weibel instability. It is found that the early phase of the instability is in excellent agreement with the linear theory. But, an analysis based on an alternative magnetic trapping saturation theory reveals that a substantial discrepancy between the theory and simulation is revealed in the relativistic regime in contrast to an excellent agreement in the non-relativistic regime. The analysis of the Weibel instability beyond the quasilinear saturation stage shows an inverse cascade process via a nonlinear decay instability involving electrostatic fluctuation.

  • PDF

THE LYMAN-CONTINUUM LUMINOSITIES OF OB-TYPE STARS (OB형 별의 라이먼 연속 복사의 광도)

  • Seon, Kwang-Il
    • Publications of The Korean Astronomical Society
    • /
    • v.22 no.4
    • /
    • pp.97-101
    • /
    • 2007
  • We are often faced with the task of having to estimate the hydrogen and helium ionizing luminosities of massive stars in the study of H II regions and the warm ionized medium (WIM). Using the results of the most complete compilation of stellar parameters (the effective temperature, stellar radius and surface gravity) and the latest Kurucz stellar atmosphere models, we calculate the ionizing photon luminosities in the $H^0\;and\;He^0$ continua from O3 to B5 stars. We compared the theoretical Lyman-continuum luminosity with the observationally inferred luminosity of the H II region around ${\alpha}$ Vir, and found that the theoretical value is higher than the observed value in contrast to the eariler result.

Context-free Marker-controlled Watershed Transform for Over-segmentation Reduction

  • Seo, Kyung-Seok;Cho, Sang-Hyun;Park, Chang-Joon;Park, Heung-Moon
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.482-485
    • /
    • 2000
  • A modified watershed transform is proposed which is context-free marker-controlled and minima imposition-free to reduce the over-segmentation and to speedup the transform. In contrast to the conventional methods in which a priori knowledge, such as flat zones, zones of homogeneous texture, and morphological distance, is required for marker extraction, context-free marker extraction is proposed by using the attention operator based on the GST (generalized symmetry transform). By using the context-free marker, the proposed watershed transform exploit marker-constrained labeling to speedup the computation and to reduce the over-segmentation by eliminating the unnecessary geodesic reconstruction such as the minima imposition and thereby eliminating the necessity of the post-processing of region merging. The simulation results show that the proposed method can extract context-free markers inside the objects from the complex background that includes multiple objects and efficiently reduces over-segmentation and computation time.

  • PDF