• Title/Summary/Keyword: regeneration process

검색결과 731건 처리시간 0.024초

재생입구 직접증발냉각기 적용이 제습냉방시스템 성능에 미치는 영향 (Effects of Performance Analysis of a Desiccant Cooling System with a Direct Evaporative Cooler in the Inlet of Regeneration Process)

  • 다쉬 울찌우타스;성상철;오명도;이대영
    • 설비공학논문집
    • /
    • 제22권5호
    • /
    • pp.328-335
    • /
    • 2010
  • The purpose of this study is to make an analysis of influence on the cooling capacity and COP of a desiccant cooling system with a regenerative evaporative cooler when a direct evaporative cooler was applied to the inlet of regeneration process of this system. We used cycle simulation in order to analyze the performance of this system. From the cycle simulation, we knew that the optimal rotation time of desiccant rotor was between 160s and 220s and hardly ever affected cooling capacity of desiccant cooling system when this system was operated at the outdoor air condition of $35^{\circ}$ and 40% RH and low regeneration temperature of $60^{\circ}$. Also there was optimal area ratio of regeneration to dehumidification between 0.7 and 1.0. Our results showed that it had a small effect on the system’s cooling capacity to install direct evaporative cooler at the inlet of regeneration process.

이소프렌 정제를 위한 제올라이트 5A 흡착제 재생 (Regeneration of Zeolite 5A in the Adsorption Process for Isoprene Purification)

  • 전경진;유계상;이창하;안병성
    • 청정기술
    • /
    • 제16권4호
    • /
    • pp.272-276
    • /
    • 2010
  • 이소프렌(isoprene)에 포함되어 있는 acetylene류의 불순물 중 2-butyne을 선택적으로 제거하기 위해 제올라이트를 흡착제로 사용한 흡착 및 탈착 특성을 연구하였다. 본 연구에서는 제올라이트 5A를 사용하여 흡착실험을 실시한 후, 흡착제를 재생하기 위한 탈착실험을 수행하여 2-butyne의 재흡착 성능을 확인하였다. 감압 및 고온의 질소 가스를 이용한 탈착실험에서 온도 영향과 탈착 시간에 따른 변화를 검토하고 재흡착실험을 실시하였으며 에너지 소비를 최소화하며 흡착성능을 유지할 수 있는 탈착조건을 확립하였다. 473 K, 16시간 탈착 및 액상흡착 반복실험을 10회 진행하여 흡착제의 재생가능성을 확인하였다.

도시재생사업 계획지표에 관한 지역주민의 가치평가 연구 - 목포시 지역 주민을 대상으로 - (A Study on Local Residents' Evaluation of the Planned Indicator Value for Urban Regeneration - Targeting Local Residents in Mokpo -)

  • 신은주;유창균;조성진
    • 한국주거학회논문집
    • /
    • 제26권6호
    • /
    • pp.71-81
    • /
    • 2015
  • In terms of urban regeneration of the present that focuses on a city's original history, culture and environment, it is now being understood as a concept of how a city by itself gets vitalized through local participation and communities. That is what indicates how a main agent of urban regeneration is changing to relevant local residents from public organizations and due to that reason, establishment of a differentiated urban regeneration policy that would reflect opinions of the locals is demanded. In the light of that, this study aimed to offer an urban regeneration project planning indicators targeting an old downtown area of Mokpo city which has been selected as an urban regeneration district. An AHP (Analytic Hierarchy Process) survey on the locals had revealed priorities of the indicators which helped the study to present indicators to be practically used for the urban regeneration project on the old downtown area in Mokpo.

Development Framework of Interactive Electronic Technical Manual for Urban Regeneration

  • Son, Bo-Sik;Yu, Jung-Ho;Park, Moon-Seo;Jeong, Jin-Wook;Lee, Sang-Hyun
    • Journal of Construction Engineering and Project Management
    • /
    • 제2권1호
    • /
    • pp.20-26
    • /
    • 2012
  • Urban regeneration is a large-scale program that must address challenges such as a significant number of involved projects, diverse participants and their conflicting objectives, and a long life span. In an effort to address these issues, the Interactive Electronic Technical Manual (IETM) is applied to urban regeneration in order to provide a guideline to enhance urban regeneration program management. Through a survey, three major functionalities required in the IETM are identified: process map provision, customized information delivery, and communication ability with other information systems. To achieve these functionalities, the development framework of the IETM and the associated technologies are examined.Its characteristics can be sum up ontology-driven metadata, user-oriented process map composition system and so on. Finally, the usage scenarios of the IETM are discussed.

도시재생사업의 의사결정 지원을 위한 가치체계 관리 방안 (The Method of Value System Management to support decision-making of Urban Regeneration Project)

  • 강현구;유정호;김창덕;손보식
    • 한국건설관리학회논문집
    • /
    • 제10권4호
    • /
    • pp.139-150
    • /
    • 2009
  • 도시재생의 패러다임은 재개발사업과 같은 물리적 개발 정비가 아닌 중심상업 업무기능을 포함한 행정 관리기능, 광역적인 문화 관광기능, 국제적 기능, 적정수준의 주거 기능이 균형적으로 활성화 될 수 있도록 바뀌어 가고 있다. 도시재생 사업은 물리 환경, 생활 문화, 산업 경제적 재생을 통해 도시의 기능을 회복하는 것을 목적으로 하며 이러한 도시재생사업에는 다수의 프로젝트들이 포함되어 있어 기존의 프로젝트 매니지먼트와는 많은 차이가 있다. 도시재생사업이 추구하는 가치와 사업 내에 존재하는 다수의 프로젝트들이 추구하는 가치 간의 관리를 통해 전체 사업을 관리해야만 한다. 본 연구의 목적은 사업 내에 존재하는 여러 목적으로 인한 충돌을 방지하기 위하여 가치관리 방안을 제시하는 것이다. 이에 본 연구에서는 가치체계를 수립함으로써 사업간 목적의 충돌을 방지하고 변화에 유연한 목표 및 가치의 체계를 구축하고자 한다. 또한 각 가치간의 상관관계 및 우선순위를 도출하여 의사결정 지원을 위한 가치체계 관리 방안을 제시하고자 한다.

팽창과정에서의 터보엑스펜더 영향에 관한 연구 (Effect of a Turbo-Expander for Regeneration in the Expansion Process)

  • 조종현;조봉수;김재실;조수용
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.157-160
    • /
    • 2006
  • A turbo-expander is developed for the regeneration in the expansion process. The turbo-expander operates in the partial admission and supersonic flow, and an axial-type single stage turbine is applied to the turbo-expander. Its outer diameter is 82mm and the operating gas is R134a. A 15kW reciprocating compressor is applied in this experiment and the turbo-expander is installed in the expansion process instead of the commonly using expansion valve. Two supersonic nozzles are applied for the expansion process. The high speed of R 134a after passing the supersonic nozzles gives the impulse force to the turbo-expander and some powers are generated on this process. A generator is installed at the end of the turbo-expander shaft. The generating output power from the turbo-expander is controlled by the power controller. Pressures and temperatures are measured on the lines for the performance investigation. More than 600W/(kg/sec) are generated in this experiment.

  • PDF

건식회전형 제습기의 성능향상에 관한 실험적 연구 (An Experimental Study on Improved Performance of Rotary Solid Dehumidifier)

  • 이기영;김효경
    • 대한설비공학회지:설비저널
    • /
    • 제16권3호
    • /
    • pp.285-294
    • /
    • 1987
  • Parametric study on the efficiency of Rotary Solid Dehumidifer are reported. Experi-ments have been performed by varying regeneration temperature, regeneration humidity, flow rate of regeneration air, angular velocity of dehumidifer rotor and regeneration angle. To improve the energy efficiency, MODE 2,3 where coding zone is constructed and MODE 4, 5 where recirculating zone is constructed, were studied through experimental method $\ldots$. These results show that economical operating ranges exist in regeneration temperature, flow rate of regeneration air, angular velocity of dehumidifier rotor and regeneration angle. MODE 2,3 where cooling zone is constructed between regeneration Bone and process zone, is far better than MODE 1 in view of energy effiency, and optimum cooling angle and flow rate of cooling air exist. But MODE 4 and MODE 5, where recirculating zone is constructed, are similar to MODE 1.

  • PDF

아미노산염을 이용한 이산화탄소 흡수제 연속 재생에 관한 연구 (Study of continuous regeneration of carbon dioxide sorbent using amino acid salt)

  • 최진식;김재강;이준형;추연진;이주열;박병현
    • 한국응용과학기술학회지
    • /
    • 제34권4호
    • /
    • pp.947-953
    • /
    • 2017
  • 본 연구에서는 이산화탄소 흡수/재생 공정에 효율적으로 적용할 수 있는 아미노산염 흡수제의 연속재생을 통해 재생효율을 확인하였다. 재생효율은 공정적용에 있어 경제성에 큰 영향을 끼치는 인자로, 보다 경제성 있는 이산화탄소 흡수/재생 공정 확립을 위해 연속재생 실험을 진행하였다. 실험에 사용한 아미노산염은 Potassium L-lysinate와 Potassium L-alaninate이며, 각 아미노산과 Potassium hydroxide(KOH)를 1:2 몰비로 혼합하여 사용하였다. 흡수제의 재생 효율을 확인하기 위해 두 물질에 이산화탄소를 충분히 흡수시킨 후 가열을 통해 이산화탄소 탈리실험을 진행하였다. 반응초기에는 L-alanine의 반응속도가 빠르게 이루어졌으나, 시간이 지남에 따라 흡수량이 보다 큰 L-lysine이 높은 농도의 이산화탄소를 배출하였다. 두 물질의 재생효율을 비교하였을 때, L-alanine은 47.26%, L-lysine은 62.11%로 L-lysine이 더 높은 재생효율을 나타내었다. 흡수량 및 재생효율이 좋은 L-lysine을 이용한 연속재생 실험결과, 재생횟수가 증가함에 따라 재생효율이 감소하는 것을 확인 할 수 있었다.

A novel and safe small molecule enhances hair follicle regeneration by facilitating metabolic reprogramming

  • Son, Myung Jin;Jeong, Jae Kap;Kwon, Youjeong;Ryu, Jae-Sung;Mun, Seon Ju;Kim, Hye Jin;Kim, Sung-wuk;Yoo, Sanghee;Kook, Jiae;Lee, Hongbum;Kim, Janghwan;Chung, Kyung-Sook
    • Experimental and Molecular Medicine
    • /
    • 제50권12호
    • /
    • pp.5.1-5.15
    • /
    • 2018
  • Targeting hair follicle regeneration has been investigated for the treatment of hair loss, and fundamental studies investigating stem cells and their niche have been described. However, knowledge of stem cell metabolism and the specific regulation of bioenergetics during the hair regeneration process is currently insufficient. Here, we report the hair regrowth-promoting effect of a newly synthesized novel small molecule, IM176OUT05 (IM), which activates stem cell metabolism. IM facilitated stemness induction and maintenance during an induced pluripotent stem cell generation process. IM treatment mildly inhibited mitochondrial oxidative phosphorylation and concurrently increased glycolysis, which accelerated stemness induction during the early phase of reprogramming. More importantly, the topical application of IM accelerated hair follicle regeneration by stimulating the progression of the hair follicle cycle to the anagen phase and increased the hair follicle number in mice. Furthermore, the stem cell population with a glycolytic metabotype appeared slightly earlier in the IM-treated mice. Stem cell and niche signaling involved in the hair regeneration process was also activated by the IM treatment during the early phase of hair follicle regeneration. Overall, these results show that the novel small molecule IM promotes tissue regeneration, specifically in hair regrowth, by restructuring the metabolic configuration of stem cells.

태양열 온수기를 이용한 다목적 공조시스템의 재생효율에 관한 연구(제1보 액체흡수제 온도가 재생량에 미치는 영향) (Research on the Performance of Regenerator using Hot Water from Solar Water Heater(1st paper : On the Effect of Solution Temperature to Regeneration Rate))

  • 우종수;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제24권1호
    • /
    • pp.53-61
    • /
    • 2004
  • Absorption potential of desiccant solution significantly decreases after absorbing moisture from humid air, and a regeneration process requires a great amount of energy to recover absorption potential of desiccant solution. In an effort to develop an efficient solar water heater, this study examines a regeneration process using hot water obtained from solar water heater to recover absorption potential by evaporating moisture in the liquid desiccant. In this paper, a solar absorption dehumidifying system with solar water heater is suggested to save the electricity for operating an air conditioner. LiGl(lithium chloride) solution was adopted as a liquid desiccant in the proposed system, and hot water obtained from the solar water heater was used for regenerating the liquid desiccant. As a result, it was clear that the dilute LiCl solution could be regenerated by hot water, and the regeneration rate depends mostly on temperature level of liquid desiccant. The regeneration rates were about 2.4kg/h with $40^{\circ}C$, 4.0kg/h with $50^{\circ}C$, and 6.2kg/h with $60^{\circ}C$ of hot water respectively.