• 제목/요약/키워드: refueling station

검색결과 97건 처리시간 0.025초

수소 충전소 연료계량방법의 차이에서 발생하는 연료단가의 상이점에 대한 고찰 (A Study on the Variation of Unit Price of Hydrogen Fuel by Difference of Fuel Measuring Method)

  • 이택홍;강병우;이은웅;정진배
    • 한국수소및신에너지학회논문집
    • /
    • 제28권3호
    • /
    • pp.279-286
    • /
    • 2017
  • Korea government decides to build one hundred hydrogen refueling stations (HRS) until 2020 and tries to disseminate HRS and boosts HRS market in korea. Naepo HRS in chungnam province has been operated for last one full year of 2016 and recorded 2,520 times full charge for the hydrogen fuel cell powered vehicles and total 6,016 kg hydrogen fueling for the 25 units of hydrogen fuel cell powered vehicles. Raw fuel of hydrogen from tube trailer measured by pressure, converting into weight of hydrogen and shows 19.6% surplus with final charged weight by dispenser. This result is caused measuring errors. Measured charged errors between dispenser and Mass flow meter was determined 13.13%.

바이모달트램 운행을 위한 운영기반시스템 개발에 관한 연구 (A Study on the Development of Operation Base System for Bimodal Tram)

  • 윤희택;박영곤;변윤섭;이강원;홍용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1937-1942
    • /
    • 2007
  • Bimodal tram is being developed to be completed in 2010 and the infrastructure needs to be developed to make the operation in time. Through the study of infrastructure reflecting domestic condition, dedicated lane, station, connection center, automated operation, precise docking, ticketing system, information system, management system for operation and maintenance, and refueling station will be developed and their performances will be also verified through the construction of test bed. The economical, safe and environment-friendly operation of the bimodal tram will be established through the present study.

  • PDF

수소-LPG 복합충전소 정량적 위험성평가에 관한 연구 (A Study on the Quantitative Risk Assessment of Hydrogen-LPG Combined Refueling Station)

  • 강승규
    • 에너지공학
    • /
    • 제28권4호
    • /
    • pp.29-34
    • /
    • 2019
  • 본 연구에서는 수소 복합충전소에 대하여 정량적 위험성 평가를 실시하였다. 평가대상의 복합충전소는 수소-LPG이며 각 충전소의 설비 구성을 분석하고 위험도를 평가하였다. 최종 위험도는 피해영향과 사고빈도를 고려한 개인적 위험성과 사회적 위험성으로 평가한다. 본 연구의 대상이 된 수소-LPG 충전소에 대한 개인적 위험도 산출 결과, 수소-LPG 형태의 복합충전소는 HSE에서 제안하고 있는 허용 불가수준의 위험지역(> 1×10E-3)은 나타나고 있지 않으며, 작업자와 일반인에 대한 개인적 위험수준이 모두 허용범위 내에 분포하고 있다. 그리고 사회적 위험도 평가에서는 해석대상 모델이 허용 가능한 범위(ALARP, As Low As Reasonably Practicable)의 위험도 분포를 보이고 있다. 보다 향상된 안전성 확보를 위해 위험도 순위화 결과에서 높은 위험도를 보이고 있는 수소 저장용기, 디스펜서, 튜브트레일러 누출 및 LPG의 Vapour 회수 라인 등에 대한 정기적인 점검 및 확인을 권장한다.

수소충전소 튜브트레일러 누출에 따른 위험성평가 (Risk Assessment of Tube Trailer Leaks at Hydrogen Charging Station)

  • 박우일;윤진희;강승규
    • 한국가스학회지
    • /
    • 제25권4호
    • /
    • pp.57-62
    • /
    • 2021
  • 본 연구는 국제공동 연구로 개발 된 HyKoRAM 프로그램을 이용하여 저장설비(튜브트레일러)의 누출 시 위험성평가를 진행하였다. 수소충전소 내의 고압가스설비는 크게 4가지로 저장설비(튜브트레일러), 처리설비(압축기), 압축가스설비, 충전설비(디스펜서)로 분류된다. 그 중 저장설비인 튜브트레일러의 설계 사양, 주변 환경 조건 등을 반영하여 기존에 발생된 사고 및 잠재적 사고 위험 사고 시나리오를 구성하였다. 이를 통해, 수소충전소 저장 설비의 위험을 확인하고 수소충전소 안전성 향상을 위한 대책을 제안한다.

국내 수소충전소의 적정 용량 분석 (Study on the Optimum Capacity Analysis for Hydrogen Fueling Station in Korea)

  • 한자령;박진모;이영철;김상민;전소현;김형식
    • 한국수소및신에너지학회논문집
    • /
    • 제28권6호
    • /
    • pp.649-656
    • /
    • 2017
  • At present, hydrogen is emerging as a future energy source based on environment-friendly aspect, creation of new industry, and enhancement of domestic energy security. In accordance with it, the world's leading automobile companies are focusing on the development and commercialization of hydrogen electric vehicle technology, and each country is strengthening its hydrogen fueling station deployment strategy for its own country. Furthermore, the supply of hydrogen fueling stations is actively promoting under national support. More than 500 hydrogen fueling stations are being constructed, operated and planned around the world. The introduction of hydrogen energy is also progressing in Korea, by announcing road-map to supply hydrogen electric vehicles and hydrogen fueling stations by year. However, there is insufficient discussion on the capacity of hydrogen fueling station in Korea. Therefore, this study suggests the optimum capacity of hydrogen fuelling station for domestic hydrogen economy.

주유소 유증기 회수설비 사용에 따른 가솔린 증기의 개인노출양상 (Occupational Exposure Aspects of Gasoline Vapor According to the Use of a Gasoline Vapor Recovery System)

  • 이희명;원종욱;김치년;노재훈
    • 한국산업보건학회지
    • /
    • 제25권2호
    • /
    • pp.156-165
    • /
    • 2015
  • Objectives: The purpose of this study was to investigate the possible effects of a gasoline vapor recovery system on personal exposure levels of gasoline vapor constituents including benzene, toluene, ethyl benzene, xylene(BTEX), and methyl tert-butyl ether(MTBE) among gas station workers in a metropolitan area. Methods: Thirty-one gas station workers at ten gas stations in a metropolitan area were selected as subjects for this study. Test method PV2028 as recommended in the OSHA process was used for sampling and analysis. Results: The personal exposure levels of benzene, toluene, ethyl benzene, xylene, MTBE and gasoline vapor in the gas station workers were $0.0018{\pm}0.0069ppm$, $0.0077{\pm}0.0137ppm$, $0.0002{\pm}0.0008ppm$, $0.0016{\pm}0.0084ppm$, $0.2619{\pm}0.3340ppm$, and $1.4940{\pm}1.7984ppm$, respectively. After adjustment for refueling frequency and volume, personal exposure levelswere higher in the gas stations where gasoline vapor recovery systems(Stage II) were not installed, but the results were not statistically significant. Gasoline vapor concentrations showed a positive correlation to the level of MTBE, a gasoline additive. Conclusions: Vapor recovery systems(Stage II) were effective not only in reducing emissions of air pollutants, but also in reducing exposure to hazardous substances among gas station workers. In addition, acorrelation between gasoline vapors and MTBE concentration was confirmed.

휴대형 라이다 스캐너와 AUTODYN를 이용한 수소 충전소 구조물의 3차원 폭발해석 (3D Explosion Analyses of Hydrogen Refueling Station Structure Using Portable LiDAR Scanner and AUTODYN)

  • 카칸 발루치;신찬휘;조용돈;조상호
    • 화약ㆍ발파
    • /
    • 제40권3호
    • /
    • pp.19-32
    • /
    • 2022
  • 수소는 다른 연료에 비해 에너지효율이 높고 유해물질이 배출되지 않아 미래의 청정에너지원으로 인식되고 있다. 그러나 수소는 밀도가 낮아 운반 및 저장시에 부피가 커서 압축하거나 특별한 운반체를 사용해야 하며, 공기중에 노출 시 화재나 폭발의 위험성이 있다. 수소-공기 혼합물의 폭발에 관한 실험이나 수치해석적 연구가 진행되어 오고 실물 수소 충전소를 대상으로 한 폭발 시뮬레이션에 관한 연구사례는 극히 드물다. 본 연구에서는 실제 수소 충전소를 대상으로 Lidar 스캐닝을 수행하여 point cloud 데이터를 획득하고 수소 충전소 3 차원 구조 모델을 작성한다. 3 차원 구조모델은 Ansys 사 AUTODYN 에 적용되어 수소 충전소의 수소폭발을 가정한 TNT 등가량의 폭발 시뮬레이션을 실시하고 주변에 전파하는 폭발압력을 계산하여, 수소 충전소 폭발에의한 주변 보안 건물의 안전거리에 관한 정보를 제공한다.

시내버스용 HCNG 고압가스 충전소의 폭발 위험성 해석 (Risk Assessment of High Pressure HCNG Refueling Station Explosion by Numerical Simulation)

  • 강승규;김영구;최슬기;권정락
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.113-113
    • /
    • 2014
  • This study has been conducted for evaluation of qualitative/quantitative risk of HCNG filling station. In case of fire explosion occurred because of hydrogen, CNG, and HCNG leaking on same conditions, maximum overpressure was measured as 30kPa for hydrogen, 3.5kPa for HCNG, and 0.4kPa for CNG. The overpressure of HCNG was measured 7.75 times higher than that of CNG, but it was only 11.7% compared with hydrogen. When the explosion was occurred, in case of hydrogen, the measured influential distance of overpressure was 59m and radiant heat was 75m. In case of CNG, influential distance of overpressure was 89m and radiant heat was 144m would be estimated. In case of 30% HCNG that was blended with hydrogen and CNG, influential distance of overpressure was 81m and radiant heat was 130m were measured. As the explosion occurred with the same sized container that had 350bar for hydrogen and 250bar of CNG and HCNG, the damage distance that explosive overpressure and radiant heat influenced CNG was seen as the highest. HCNG that was placed between CNG and hydrogen tended to be seen as more similar with CNG.

  • PDF

일반형 주유기의 셀프 주유시스템 구축 (A Study on the self fuel fueling system development of a regular type lubricator)

  • 김현수;강남선;엄한성;박중순;노영오
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 추계종합학술대회
    • /
    • pp.329-332
    • /
    • 2003
  • 본 논문에서는 마이크로프로세서를 사용하여 주유소 이용자가 주유기 조작방법을 모르더라도 직접 주유할 수 있는 간단한 인터페이스를 구현하고자 한다. 현재 주유소 이용자가 직접 주유할 수 있는 셀프 주유기가 상용화 되어있지만 셀프 주유기를 별도로 설치 해야하며, 주유 과정이 복잡하여 셀프 주유를 꺼리는 실정이다. 이러한 과정을 신용카드나 현금을 이용하여 주유 금액을 결재하면 모든 과정이 자동적으로 처리되어 주유기 조작법을 모르더라도 간단하게 주유할 수 있으며, 주유소에서는 셀프 주유를 하기 위해 셀프 주유기를 따로 구매할 필요 없이 간단한 회로를 인터페이스 하여 셀프 주유를 병행할 수 있는 시스템을 개발하고자 한다.

  • PDF

천연가스 개질형 $30Nm^3/hr$급 수소스테이션 연구개발 현황 (Current Progress of Development of $30Nm^3/hr$ Scale Hydrogen Refueling Station with Natural Gas Reformer)

  • 이영철;조영아;박달영;최정환;김재동;송택용;조병학;김동혁;이중성;오영삼;홍성호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.25-28
    • /
    • 2006
  • 수소는 청정에너지로서 미래에너지의 대안으로 여겨지고 있기 때문에 수소에너지 관련 기술은 미래 국가 경쟁력을 좌우할 것으로 예상되며 이러한 수소에너지의 핵심인 수소스테이션 관련 기술은 국가연료전지 시장을 비롯한 수소자동차 사업 전반에 커다란 영향을 미칠 것으로 예상되고 있다. 이에 따라 전 세계적으로 수소에너지를 차세대 에너지원으로 개발하기 위하여 전력을 다하고 있으며, 수소연료전지자동차 개발과 아울러 수소스테이션 개발에 대한 인프라 구축 및 실증연구가 본격적으로 이루어지고 있다. 국내에서도 가스공사를 비롯한 에너지 관련 기업에서 수소스테이션 건설이 추진되고 있으며, 본 연구에서도 수소인프라 구축의 일환으로 추진되고 있는 수소스테이션 개발 현황에 대하여 논의하고자 한다.

  • PDF