• Title/Summary/Keyword: refrigeration effect

Search Result 850, Processing Time 0.035 seconds

The Effect of R-134a and R-430a on the Performance of Refrigeration Equipment for R-134a (R-134a용 냉동장치의 성능에 미치는 R-134a와 R-430a의 영향)

  • Byun, Chul-Kju;Kang, Hyung-Suk
    • Journal of Industrial Technology
    • /
    • v.34
    • /
    • pp.21-26
    • /
    • 2014
  • The effect of refrigerant R-134a and R-430a on the performance of refrigeration equipment for R-134a is investigated. Refrigeration effect, compression work and coefficient of performance of refrigeration equpment for both R-134a and R-430a are obtained by experimentation. These performances comparison between R-134a and R-430a is made in case of the maximum load. Refrigeration effect for R-134a and that for R-430a is almost equal while compression work for R-134a is less than that for R-430a. Consequently it shows that coefficient of performance for R-134a is relatively 11% higher than that for R-430a.

  • PDF

Recent R&D Trend in Magnetic Refrigeration at Room Temperature (실온 자기냉동의 최근 연구개발 동향)

  • Lee, Jong-Suk
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.613-618
    • /
    • 2006
  • The 1st International Conference on Magnetic Refrigeration at Room Temperature was held at Montreux, Switzerland during September 27-30, 2005. The conference was the first of its kind to bring together about 140 scientists and engineers interested in magnetic refrigeration in one place. The magnetocaloric effect was discovered in 1881, however, magnetic refrigeration at room temperature was demonstrated to be viable in 1997 Since then, R&D efforts toward magnetic refrigeration have been on the rise around the world, in both areas of systems and materials. The conference reflected the recent R&D trend in magnetic refrigeration at room temperature, which includes the use of permanent magnet instead of superconductor magnet, switch from reciprocating to rotary magnetic refrigeration system, development of magnetic materials based on transition metal elements besides rare earth materials such as gadolinium(Gd).

  • PDF

Performance Comparison of Two-stage Compression Refrigeration System Using R404A (R410A용 2단 압축 1단 팽창 냉동시스템의 성능 분석)

  • Yoon, Jung-In;Choi, Kwang-Hwan;Son, Chang-Hyo;Jo, Hwan
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.57-62
    • /
    • 2014
  • This paper present the performance characteristics of R404A two-stage compression refrigeration system. The operating parameters considered in this study include evaporating and condensing temperature, subcooling and superheating degree, compressor efficiency. The main results were summarized as follows: The COP of two-stage compression refrigeration system using R404A has an effect on the variation of evaporation temperature, condensation temperature, subcooling degree and compressor efficiency, but not an effect on the superheating degree. R404A two-stage compression refrigeration system is unstable because COP of this system is significantly changed when evaporating temperature and compressor efficiency decreased. In particular, when compressor efficiency decreased, COP is significantly decreased. This is inefficient for long-term use.

Heating and Cooling System using the Sewage Source Absorption Refrigeration and Heat Pump Cycle (하수열을 이용한 냉난방시스템에 관한 연구)

  • Lee, Yong-Hwa;Shin, Hyun-Joon;Yoon, Hee-Chul;Park, Hyun-Gun
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.19-26
    • /
    • 2007
  • This paper concerns the study of absorption refrigeration and heat pump cycle to use sewage. Simulation analysis on the double-effect absorption refrigeration cycle with parallel and two-stage heat pump cycle has been performed. The working fluid is Lithium Bromide and water solution. The absorption refrigeration cycle use sewage as a cooling water for the absorber and condenser, and absorption refrigeration cycle does that as a chilled water for the evaporator of the first stage cycle. And the two-stage cycle consists of coupling double-effect with parallel and single effect cycle so that the first stage absorber and condenser produces heating water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as a absorber temperature on the coefficient of performance have been studied for absorption refrigeration and heat pump cycle.

An Effect of Project Learning Method in the Refrigeration Instruction for Students (냉동수업에서 프로젝트 학습법이 학생들에게 미치는 영향)

  • PARK, Jong-Un;YOUN, Joung-In;CHO, Jee-Yeh
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.17 no.2
    • /
    • pp.252-259
    • /
    • 2005
  • In this research, as an educational tool in the Refrigeration instruction, a project learning method was applied which enables active hand on practice and encourages a more active participation of students with an increased level of interest in learning. The purpose of this study is to present project learning method as an educational tool that can arouse interest and motivation of students by an active hands-on learning process. This will aid in the enhancement of understanding of educators and students in the project learning method, and assist in development of project learning method that can increase intuitiveness and originality of students. For the purpose of the study, the following questions were asked. First, what is the level of existing knowledge pertaining to Refrigeration Training Program of students? Second, what effect does Refrigeration Training Program conducted via the project approach have on the level of motivation and interest of students? Third, what effect does Refrigeration Training Program conducted via the project approach have on the study habits of students?

Experimental Study on a Rotary Magnetic Refrigeration Device (회전식 자기냉동장치에 대한 실험적 연구)

  • Lee Jong Suk;Hong Jeong Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1101-1106
    • /
    • 2004
  • Magnetic refrigeration is based on the magnetocaloric effect (MCE)-the ability of some materials to heat up when magnetized and cool down when demagnetized. A rotary magnetic refrigeration device using gadolinium (Gd) ribbon and permanent magnets was constructed for experimental study. Gd ribbon attached around a rotating wheel is cyclically magnetized and demagnetized by permanent magnets and exchanges heat with liquid in the surrounding container. Temperature of the liquid in each divided section of the container was measured and the experimental results obtained in this study were discussed.

A Study on Performance Characteristics of A Single Effect LiBr/Water Refrigeration Cycle (단효용 LiBr/물 흡수식 냉동사이클의 성능특성에 관한 연구)

  • 연제문;임삼택;오주원;이경우
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.95-99
    • /
    • 2001
  • As a way to use energy effectively, the present study is aimed at investigating the performance characteristics of a Single Effect LiBr/Water Absorption Refrigerator using a low temperature driving heat-source. It was carried out by changing the driving heat-source temperature, the cold water outlet temperature(the refrigeration load), the cooling water inlet temperature, and the weak solution flow rate and this study compares the performance characteristics of refrigerator against the existence and non-existence of the Recirculation of the Weak solution which is used as a method to improve the performance of refrigerator. In case of Recirculation of the weak solution, more improved the Refrigeration Capacity and COP was obtained, and these effects became more larger in the high temperature of driving heat-source and large quantity of solution.

  • PDF

Magnetic refrigerator for hydrogen liquefaction

  • Numazawa, T.;Kamiya, K.;Utaki, T.;Matsumoto, K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.1-8
    • /
    • 2013
  • This paper reviews the development status of magnetic refrigeration system for hydrogen liquefaction. There is no doubt that hydrogen is one of most important energy sources in the near future. In particular, liquid hydrogen can be utilized for infrastructure construction consisting of storage and transportation. Liquid hydrogen is in cryogenic temperatures and therefore high efficient liquefaction method must be studied. Magnetic refrigeration which uses the magneto-caloric effect has potential to realize not only the higher liquefaction efficiency > 50 %, but also to be environmentally friendly and cost effective. Our hydrogen magnetic refrigeration system consists of Carnot cycle for liquefaction stage and AMR (active magnetic regenerator) cycle for precooling stages. For the Carnot cycle, we develop the high efficient system > 80 % liquefaction efficiency by using the heat pipe. For the AMR cycle, we studied two kinds of displacer systems, which transferred the working fluid. We confirmed the AMR effect with the cooling temperature span of 12 K for 1.8 T of the magnetic field and 6 second of the cycle. By using the simulation, we estimate the total efficiency of the hydrogen liquefaction plant for 10 kg/day. A FOM of 0.47 is obtained in the magnetic refrigeration system operation temperature between 20 K and 77 K including LN2 work input.

Characteristic Analysis of Double Effect Absorption Refrigeration Machine using $H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$ ($H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$를 이용한 2중 효용 흡수식 냉동기 특성해석)

  • 문춘근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.792-799
    • /
    • 1998
  • Further improvement of existing $H_{2}O/LiBr$ absorption refrigeration machine is absolutely neces-sary to promote the utilization of gas-cooling system Among various methods to improve the per-formance of the absorption refrigeration machine this research has focused on the use of a new working fluid that has better properties than the existing $H_{2}O/LiBr$ working fluid. In the series of the research, $H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$ system was selected as the most promisable candidate. The absorption refrigeration machine is water-cooled double-effect, $H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$ sys-tem with series flow type. In this study we found out the characteristic of new working solution through the cycle simulation and compared the result with that of LiBr solution to evaluate. Theoptimum designs and operating conditions were determined based on the operating constraints and the coefficient of performance. Results demonstrate that new working fluid subsrantially increases COP by as much as 10% and has a wider working range with 8% higher crystallization limits compared to the conventional $H_{2}O/LiBr$.

  • PDF

Performance Characteristics of Refrigerant R170(Ethane) Refrigeration System Using Liquid-gas Heat Exchanger (액-가스 열교환기를 이용한 R170(에탄)용 냉동시스템의 성능 특성)

  • Ku, Hak-Keun
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.78-85
    • /
    • 2016
  • This paper considers the influence of internal heat exchangers to the efficiency of a refrigerating system using R170. These liquid-gas heat exchangers(internal or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as the mass flowrate of R170, inner diameter tube and length of internal heat exchanger, to optimal dimensions of the heat exchanger is also analyzed in the paper. The main results were summarized as follows : the mass flowrate of R170, inner diameter tube and length of internal heat exchanger, and effectiveness have an effect on the cooling capacity, compressor work and RCI(Relative Capacity Index) of this system. Exception for the effect of inner diameter, the RCI of R170 with respect to refrigerant mass flowrate, the length and effectiveness of internal heat exchanger is about 2.1~3.3% higher than that of R13 at the same experimental conditions. With a thorough grasp of these effect, it is necessary to design the R170 compression refrigeration cycle using internal heat exchanger.