• 제목/요약/키워드: refrigerant

검색결과 1,222건 처리시간 0.022초

전기 자동차용 폴리올 에스테르계 냉동기유의 R-1234yf 냉매와의 적합성 연구 (Study on Chemical Stabilities with R-1234yf Refrigerant of Polyol Ester Refrigerant Oil for Electric Vehicles)

  • 홍지수;정근우;김남균;신지훈;김영운;이은호;고봉성;황승용
    • Tribology and Lubricants
    • /
    • 제36권3호
    • /
    • pp.139-146
    • /
    • 2020
  • Global warming has led to an increase in demand of eco-friendly vehicles, such as electric cars, for reducing greenhouse gas emissions, and especially, regulating carbon dioxide generation. In addition, electric vehicles are equipped with an electric drive-type hermetic scroll compressor and a refrigerant, which exhibit current and future trends of using environmentally friendly refrigerants, including R-1234yf. In this study, polyol ester-based refrigeration oils are prepared via condensation esterification of polyol and fatty acids. The oils can be combined with R-1234yf refrigerant for applications in air conditioning and cooling systems of electric vehicles. The structure of synthetic polyol esters is confirmed via 1H-NMR and FT-IR spectrum analysis, and the composition of the polyol ester is analyzed via gas chromatogram analysis. Furthermore, kinematic viscosity, viscosity index, total acid value, pour point, and color are analyzed as fundamental physical properties of the synthetic polyol esters. The compatibility and chemical stability of the synthetic polyol ester combined with the R-1234yf refrigerant are obtained via high temperature and high pressure oil-resistant refrigerant tests. The changes in the oil color and catalyst activity are observed before and after the experiment to determine whether it is suitable as a refrigerator oil.

팽창밸브 개폐용 감온통 혼합가스의 첨가제 연구 (A Study on the Additives of mixed Gas charged in Thermostatic Bulb for Expansion Valve)

  • 김시영;주창식;구수진
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.126-132
    • /
    • 2014
  • The P-T characteristics of mixed refrigerant in thermostatic expansion valve sensing bulb were studied using R-134a and R-410A refrigerant. The characteristics of mixed refrigerant were investigated according to pressure variation and the variation of composition ratio of R-134A and R-410A in the temperature range of $-15^{\circ}C{\sim}15^{\circ}C$. The Thermodynamic characteristic values of the mixed refrigerants were identified using the characteristic value analysis program of mixed refrigerant(Refrop v9.0, NIST). The P-T characteristics in the case of the mixing ratio of 90:10 for R-410A and R-134A were the same result as R-22. And the physical properties showed similar results with R-22. The Maximum operating pressure(MOP) of mixed refrigerant showed a tendency to decrease with decreasing the mixing ratio of additive gases($N_2$ or He) gases. The characteristics in the case of the mixing ratio of 80:1 for mixed refrigerant and additive gases were the similar result as Reference refrigerant.(R-22 MOP, Sporlan company) In addition $N_2$ and He, both showed the same results. It was able to confirm that a MOP on the thermostatic expansion valve sensing bulb can be maintained by adjusting the mixing ratio of mixed refrigerant gases and additive gases.

R12 냉매를 이용한 냉동압축기 임펠러 유동해석 (Numerical analysis on the impeller of chiller compressor using refrigerant R12)

  • 음학진;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.696-701
    • /
    • 2001
  • The performance and the internal flow of the impeller of the centrifugal chiller compressor with refrigerant R12 as working fluid were studied numerically, using CFD code, CFX-Tascflow, which is commercially available. In this numerical study, the thermodynamic and transport properties of the refrigerant gas were generated by the property program of NIST and linked with main program to extend the capability of the code to refrigerant gases. Numerical study was applied to several mass flow rates near the design mass flow rate at constant rotating speed. Overall performance and flow characteristics of the impeller at impeller exit were investigated. The results were physically reasonable and showed good agreement with experimental measurement at the design flow rate.

  • PDF

냉장고 냉매소음 저감을 위한 단열 발포재의 진동 전달특성 분석 (Analysis of the Vibration Transmitting Characteristics of the Insulation-foam for Reducing Refrigerant-induced Noise of a Refrigerator)

  • 한형석;김민성;정의봉;서민영;이수영
    • 한국소음진동공학회논문집
    • /
    • 제20권1호
    • /
    • pp.45-50
    • /
    • 2010
  • In the refrigerator, the two-phase refrigerant-induced noise of the capillary tube in an evaporator-inlet pipe has been a great concern. The capillary tube is usually covered with insulation-foam packed in the space between inner and outer cabinets without any vibration isolation. Therefore, the refrigerant-induced vibration of the capillary tube can be easily transferred to the outer cabinet, which may increase the radiated noise. In this paper, the characteristics of transferred vibration through the insulation-foam are investigated experimentally by using the refrigerantsupplying equipment. The frequency characteristics, such as dynamic Young's modulus and loss factor, of the insulation-foam are also discussed.

냉매가열식 열펌프시스템의 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance of a Heat Pump with a Refrigerant Heating Device)

  • 김상혁;박윤철
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.707-713
    • /
    • 2006
  • To improve heating performance of the heat pump in winter season, refrigerant heating device was applied to conventional heat pump. The refrigerant heating device operates at the heating capacity does not enough to the heating load requirement of the conditioning space. When the discharge air temperature of the indoor heat exchanger goes down to below $40^{\circ}C$ which is criterion for comfort of the occupants in the conditioning space, the system also starts. The refrigerant heating system has new concept of auxiliary heating device for heat pump in winter. In this study, the system performance was analyzed through experiments and parametric study was conducted to improve the COP and control strategies.

자동차용 에어컨 성능실험과 액서지 해석 (Performance Experiment and Exergy Analysis of an Automotive Air-conditioning System)

  • 오상한;윤종갑;원성필
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.363-370
    • /
    • 2000
  • Experiments have been peformed, using pure refrigerant R134a and a zeotropic refrigerant mixture R290/R600a(60%/40%) and their performances have been analyzed by the first and second laws(exergy method) of thermodynamics. From the experimental results, variations of compressor speed and air temperature have a great effect on the performance of the system. The sum of exergy losses in compressor and evaporator is about 60% of total exergy loss, using refrigerant R134a, so it is necessary to improve the performance of compressor and evaporator. According to the experimental results using refrigerant mixture of R290/R600a(60%/40%), the exergy losses in heat exchange processes are decreased but the exergy loss in throttling process is increased. The performance of the system has been improved by 20∼30% compared with that of R134a and exergy losses have been also reduced.

  • PDF

수평평활관내의 비공비 혼합냉매의 응축에 대한 예측모델 (A Prediction Model for Condensation of Zeotropic Refrigerant Mixtures Inside a Horizontal Smooth Tube)

  • 이상무;박병덕
    • 설비공학논문집
    • /
    • 제13권4호
    • /
    • pp.262-270
    • /
    • 2001
  • This paper deals with a prediction method for the condensation of ternary refrigerant mixture inside a horizontal smooth tube. Based on some reliable assumptions, the governing equations for the local heat and mass transfer characteristics are derived, and the prediction for the condensation of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a, including R407C, is carried out. The local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, mass flux etc. are obtained for a constant wall temperature and a constant wall heat flux conditions, and the effects of the composition of HFC32/HFC125/HFC134a on heat transfer characteristics are examined. The prediction result is also compared with experimental data for condensation of ternary refrigerant mixtures. The predicted wall temperature distribution has a similar trend with experimental data but the predicted local heat transfer coefficients are 20-30% higher than the experimental data.

  • PDF

대체냉매 적용에 따른 밀폐형 압축기 저널베어링의 최적설계 (Optimum Design of Hermetic Compressor Joumal Bearing with Alternative Refrigerant Application)

  • 이규한;김정우;이장희
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제27회 춘계학술대회
    • /
    • pp.218-227
    • /
    • 1998
  • Present study is undertaken to optimize the lubrication reliability and frictional loss of the dynamically-loaded journal bearing in hermetic reciprocating compressor with alternative refrigerant R600a application. Thermodynamic and dynamic analysis has been conducted to investigate cylinder pressure variations by substitution alternative refrigerant R600a for R12. The modeling of the dynamics of the compressor mechanism has been performed with lumped mass method. A mathematical model is developed for analyzing the dynamics of the journal bearing system with the mobility method. It takes into account the effects of the refrigerant species, aspect ratio, clearance ratio and surface roughness. A corresponding computer program is described which enables to obtain the minimum film thickness and frictional loss. Design optimization is graphically performed by parametric studies of the aspect ratio and clearance ratio.

  • PDF

가열기가 내장된 냉매오일 분리기의 성능 고찰 (Performance Analysis of the Refrigerant oil separator with a build-in heater)

  • 김종열
    • 동력기계공학회지
    • /
    • 제15권6호
    • /
    • pp.41-46
    • /
    • 2011
  • Refrigerant oil reduces friction between piston and cylinder of compressor and is normally hard to mix or dissolve in refrigerant. Oil separator deprives refrigerating oil from mixed solution of refrigerant and refrigerant oil. Sometimes much machine oil is carried into an evaporator and is applied to surface of the evaporator, and then disturbs heat transfer through it. Well-made oil separator helps refrigerating system stable and evaporator sustain full capacity. In this paper, new oil separate with different way to structure is suggested and tested. As result the new separates is 13% higher at 0C with 10% mixture and 6% higher at 0C with 20% mixture.

R410A 냉매를 사용한 열펌프용 열교환기의 형상에 따른 성능특성 연구 (A Study on Performance Characteristics of Heat Exchanger for Heat Pump with R410A Refrigerant)

  • 정규하;박윤철;오상경
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.340-348
    • /
    • 2004
  • The air and refrigerant side heat transfer performances are key parameters to improve heat transfer efficiency of the heat exchanger including the fan performance. Design of the fins, treatment of the tube inside, tube diameter and tube array effect heat transfer performance of the heat exchanger. The heat exchanger is used as a condenser at cooling mode and used as an evaporator at heating mode in the heat pump system. The heat pump system uses R410A as the refrigerant. The heat exchangers are consisted with 7 mm diameter tubes with slit-type fins. The study was conducted with variation of arrangement of the refrigerant path and air flow rate and refrigerant pressure drop and heat transfer rate were measured with a code tester. The capacity of the 3 path heat exchanger is more efficient than 2 or 4 path heat exchangers in heating or cooling modes.