• Title/Summary/Keyword: refractive index change

Search Result 187, Processing Time 0.03 seconds

Measurement of Absorption Coefficient for Quantum Confined Stark Effect In GaAsP/In P MQW Na Refractive Index Change

  • Song, Ju-Bin;Killey, R.
    • Journal of the Optical Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.123-130
    • /
    • 2001
  • In this paper, we report measurement of absorption coefficient for various InGaAs MQW QCSE device structures. The absorption spectra over a range of QCSE were obtained from measured photocurrent spectra. The refractive index changes with applied electric field were calculated from the absorption spectra.

A Study on the characteristics of the Double Refractive Index Fiber in the 1.55$mu extrm{m}$ (파장 1.55$mu extrm{m}$에서 이중굴절율 분포를 가진 광섬유의 특성에 관한 연구)

  • 최태일;이주형;최병하
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.14 no.5
    • /
    • pp.571-577
    • /
    • 1989
  • In this paper, the double-refractive index profile, which is generalized a trapezoidal index profile, is proposed to study the characteristics of a optical fiber in the wave length 1.55um. Being compared with a triangle profile, it has many advantages over an optimum core radius, the minimum refractive index difference and the change of chromati dispersion characteristics with wavelength. Though the value of a varies from 2 to infinite, the same results are approximately obtained. Therefore, in fabrication of a fiber, the step part of trapezoidal index profile can replace the profile of a-power refractive index. Because the refractive index presented in this paper varies with a, it can be applied to multiple cladding fiber or segmented core fiber. And it is expected that the characteristics of the fiber are obtained.

  • PDF

The Effect of Front Facet Reflections on the Reflectivity Spectrum of Bragg Reflector structures (단면 반사율이 Bragg Reflector 구조의 전체 반사율 스펙트럼에 미치는 효과)

  • 김부근
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1991.06a
    • /
    • pp.203-208
    • /
    • 1991
  • We present an analytic equation for the reflectivity spectrum of a Bragg reflector in terms of the front mirror reflectivity, due to the refractive index difference between the refractive index of outside medium and the average refractive index of Bragg reflector structures, and the reflectivity of a Bragg reflector calculated by the coupled wave method. We show that even Fresnel reflection causes the reflectivity spectrum of a bragg reflector to be very different from that of Bragg reflectors calculated by the coupled wave method. The reflectivity spectrum of a Bragg reflector is dramatically changed because the interference effect between the reflected wave from the front facet and that from the Bragg reflector is changed due to the difference of a phase change from a Bragg reflector when the sequence of layers in a Bragg reflector is changed.

  • PDF

Study on pH Sensor using Methylene Blue Adsorption and A Long-Period Optical Fiber Grating Pair

  • Jeon Young-Hee;Kwon Jae-Joong;Lee Byoung-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.28-32
    • /
    • 2006
  • We propose a new pH-sensing scheme using a methylene blue adsorption on an optical fiber cladding surface. Interactions between the silica and hydroxyl ions of a base solution induce the surface of the silica negatively charged. The charged surface attracts the positively charged chromophores of methylene blue. As the pH of the solution is reduced, the electrostatic attraction will also be reduced. This electrostatic attraction can change the transmitted light intensity of the cladding mode, since the boundary condition changes. We also carried out a simulation to verify the effect from external refractive index change around a long-period fiber grating. Our results confirm that the wavelength shift by external refractive index change is negligible compared to the transmitted light intensity variation of the cladding mode. By using a long-period grating pair, we can detect the cladding mode transmittance variations. Experimentally, we showed the possibility of pH sensing in the $1.5{\mu}m$ infrared region.

A robust optical security system using polarization and phase masks

  • Kim, Jae-Hyun;Shin, Chang-Mok;Seo, Dong-Hoan;Kim, Jong-Yun;Park, Se-Joon;Kim, Soo-Joong
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.919-922
    • /
    • 2000
  • A robust optical security technique using ortho-gonally polarized lights in the interferometer is proposed. We use orthogonally polarized lights in order to minimize the noise generated by the refractive index change due to vibration, flow of air, change of temperature etc. To make orthogonally polarized lights the first beam splitter in the Mach-Zehnder interferometer is substituted by a polarizing beam splitter(PBS). Because of incoherence of orthogonally polarized lights, the noise generated by the change of refractive index is minimized. To encrypt an image we use the random partition and the diffusing of pixel. Finally we make Phase-only-filters of each image which is randomly partitioned and diffused pixel by pixel. Simulation results show the proposed system has the ability of encryption and decryption of an image.

  • PDF

Properties of Indium Tin Oxide Multilayer Fabricated by Glancing Angle Deposition Method

  • Oh, Gyujin;Lee, Kyoung Su;Kim, Eun Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.367-367
    • /
    • 2013
  • Commercial applications of indium tin oxide (ITO) can be separated into two useful areas. As it is perceived to bear electrical properties and optical transparency at once, its chance to apply to promising fields, usually for an optical device, gets greater in the passing time. ITO is one of the transparent conducting oxides (TCO), and required to carry the relative resistance less than $10^{-3}{\Omega}$/cm and transmittances over 80 % in the visible wavelength of light. Because ITO has considerable refractive index, there exist applications for anti-reflection coatings. Anti-reflection properties require gradual change in refractive index from films to air. Such changes are obtained from film density or nano-clustered fractional void. Glancing angle deposition (GLAD) method is a well known process for adjusting nanostructure of the films. From its shadowing effects, GLAD helps to deposit well-controlled porous films effectively. In this study, we are comparing the reference sample to samples coated with controlled ITO multilayer accumulated by an e-beam evaporation system. At first, the single ITO layer samples are prepared to decide refractive index with ellipsometry. Afterwards, ITO multilayer samples are fabricated and fitted by multilayer ellipsometric model based on single layer data. The structural properties were measured by using atomic force microscopy (AFM), and by scanning X-ray diffraction (XRD) measurements. The ellipsometry was used to determine refractive indices and extinction coefficient. The optical transmittance of the film was investigated by using an ultraviolet-visible (UV-Vis) spectrophotometer.

  • PDF

Preparation of Hard Coating Solutions with High Refractive Index for Polycarbonate Sheet by the Sol-Gel Method (Sol-Gel 법에 의한 Polycarbonate 시트에 적용 가능한 고굴절률을 보이는 하드코팅 용액의 제조)

  • Cheong, Il Yeop;Cho, Kyung In;Cheong, Sang Hyuk;Park, Hyo Nam;Song, Ki Chang
    • Korean Chemical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.335-339
    • /
    • 2007
  • In order to overcome the problem of poor hardness of transparent polycarbonate (PC) sheets, organic-inorganic hybrid hard coating solutions, which show a high refractive index above 1.58, were made by the sol-gel method. These hybrid coating solutions were obtained from mixture of titanium tetraisopropoxide (TTIP), and (3-glycidoxypropyl)trimethoxysilane (GPTMS). The PC sheets were spin-coated, and cured at $120^{\circ}C$ for 2 hr. Change of refractive index in the range of 1.53-1.61 was obtained by varying the GPTMS content. The refractive index of the coated film decreased with increasing the GPTMS content, while the pencil hardness of the coated film was found to increase with increasing the GPTMS content.

Optimization of Thermo-Optic Parameters for Temperature-Insensitive LPWG Refractometers

  • Lee, Dong-Seok;Kim, Kyong-Hon;Hwang, Seok-Hyun;Lee, Min-Hee;Lee, El-Hang
    • ETRI Journal
    • /
    • v.28 no.6
    • /
    • pp.739-744
    • /
    • 2006
  • In this paper, we report numerically calculated results of testing a temperature-insensitive refractive sensor based on a planar-type long-period waveguide grating (LPWG). The LPWG consists of properly chosen polymer materials with an optimized thermo-optic coefficient for the core layer in a four-layer waveguide structure. The resonant wavelength shift below the spectral resolution of the conventional optical spectrum analyzer is obtained accurately over a temperature change of ${\pm}7.5^{\circ}C$ even without any temperature control. The refractive index sensitivity of the proposed grating scheme is about 0.004 per resonant wavelength shift of 0.1 nm for an optimized thermo-optic coefficient.

  • PDF

Change of Refractive Index and Residual Stresses of Ta2O5 Thin Film Prepared by Dual Ion Beam Sputtering Deposition as the Substrate Temperature and Assist ion Beam Energy (이중 이온빔으로 제작한 Ta2O5 박막의 기판 온도 및 보조 이온빔 에너지에 따른 굴절률과 판류응력의 변화)

  • Yeon, Seok-Gyu;Kim, Yong-Tak;Kim, Hwek-Yung;Kim, Myoung-Jin;Lee, Hyung-Man;Yoon, Dae-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.1
    • /
    • pp.28-32
    • /
    • 2005
  • The optical properties and intrinsic stress of $Ta_{2}O_{5}$ thin films deposited by Dual ion-Beam Sputtering: (DIBS) and Single ion-Beam Sputtering (SIBS) were studied as a function of the substrate temperature and assist ion beam voltage. The refractive index showed the maximum value (n = 2.144) at $150^{circ}C$ in the SIBS process. When the substrate temperature has above $150^{circ}C$ in the SIBS process the refractive index decreased. In the DIBS process, the increase of the substrate temperature affected the increase of the refractive index at a maximum value (n = 2.1117, at $200^{circ}C$). The low temperature process $(<100^{circ}C)$ can greatly reduce residual stress with the assist ion gun, but the high temperature process was unaffected. As the assist ion beam voltage increase from 250 to 350 V the refractive index increased to 2.185. However, the refractive index was decreased at the range of 350-650 V, As the assist ion beam voltage increased, the stress of the deposited film decreased to 0.1834 GPa at 650 V.

A Study on the Thermal Characteristics of Tunable Filter Using Fiber Bragg Grating (광 파이버 브래그 격자를 이용한 파장가변형 필터의 온도 특성에 관한 연구)

  • Son, Yong-Hwan;Lee, Jong-Youn;Heo, Ju-Ok;Jung, Jin-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.635-638
    • /
    • 2005
  • In this paper, we present thermal characteristics of a fiber Bragg grating(FBG) filter, including peak reflectivity, FWHM bandwidth, and wavelength shift by various refractive index change. The reflection spectrum of a FBG filter with refractive index change is affected by its thermal stability.

  • PDF