• Title/Summary/Keyword: refraction test

Search Result 130, Processing Time 0.021 seconds

A Study on the Spectacles Wearing State of High School Students (고등학생들의 안경착용에 관한 연구)

  • Doo, Ha-Young;Sim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.107-116
    • /
    • 2000
  • This study is of investigation of refraction error, spectacles and contact lenses wearing state, visual acuity test, ophthalmologic common sense and vision care, using questionnaire study for 850 male and female high school students in Kunsan and Chongup City, Cheolla North Province. The results are as follows: 1. Among the 823 answerers, emmetropia is 18%, myopia is 55.1%, and hyperopia is 7%, respectively. 2. Among the 837 answerers, 381 students(45.5%) wear spectacles or contact lenses. Among the 381 students who wear spectacles or contact lenses, 78% wear only spectacles, 4% wear only contact lenses and 18% wears spectacles sometimes or contact lenses sometimes. 3. The places where the answerers had visual acuity test to wear spectacles or contact lenses are optical shop(64.7%), hospital(28.3%), unchecked(4.2%) and the others(2.7%). The places where the answerers had visual acuity test to change their spectacles or contact lenses are optical shop(82%), hospital(28.3%), unchecked(6.6%) and the others(1.9%). 4. As for the period of visual acuity test, from 6 months to one year is 54.1%, within 6 months is 9.2%, from one year to two years is 29.5%, and more than two years is 7.2%. 5. The contact lens wearers purchased their contact lenses at optical shops(94%) and at hospital(6%). 6. The reasons why they like wearing contact lenses are their appearance(51.2%), convenience in physical excercise(23.l%), lighter weight than spectacles(9.8%) and the others(15.7%). 7. As for the spectacles frame they like, plastic frame is 24.4%, gold or silver plated frame is 43.4%, coloured frame is 32.1%. 8. As for the considerations in choosing spectacles frame, their design is 37%, their quality is 36%, their price is 14.7% and their brand is 12.5%. 9. As for the period for changing spectacles, 10.5% is within 6 months, 57.3% is 6months to 1 year, 22.4% is 1 year to 2 months and 9.6% is more than 2 years. 10. There is a false fact, in Korea, that even though one has his poor eyesight, not wearing custom is helpful for the eyesight recovery. As for their conviction of the false fact, 10.5% of the answerers have 100% conviction, 22.5% of them have 22.5% conviction, 49.5% of them have 50% conviction and 17.5% of them don't have any conviction. 11. 48.5% of the answerers are interested in their vision care while 51.5% of them are not interested at all. As for the way of vision care, the vision-care way to keep enough distant when they are watching TV, when they are using computers and when they are reading, is 49% while the vision-care way such as hypogastric breathing or eye massage is 11%. And alimentotherapy is 4% and the rest who are not interested in vision care is 36%. 12. When they come to an age, the students who want vision correction operation are 45.9% while the students who do not want it are 27%. The students who do not have any idea about the operation are 27.1%

  • PDF

Comparative Effect of Spectacles and Orthokeratology Lenses on Axial Elongation in Children with Mild-to-Moderate Myopia (중등도 이하 소아 근시에서 안경과 각막굴절교정렌즈 착용이 안축장 성장에 미치는 영향 비교)

  • Kim, Tae Hee;Kim, Myung Hun;Kwag, Joo Young;Choi, Jin Seok;Pak, Kyu Hong;Lee, Kyeongwook;Park, Taeseong;Chung, Sung Kun;Hyun, Joo
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1009-1016
    • /
    • 2018
  • Purpose: To assess the effect on axial elongation and associated factors between spectacles and of orthokeratology lens (OK) wearing in children with mild to moderate myopia. Methods: A total of one hundred subjects, ranging in age from 6 to 13 years, and with mild to moderate myopia no more than -4.50 diopters in spherical equivalent, visited our clinic from 2013 to 2015. The OK group (75 eyes) and the spectacles group (64 eyes) were compared and analyzed on the axial elongation and associated factors. Results: In the OK group, axial length was elongated in 1 year period with a mean increase of $0.24{\pm}0.29mm$. In spectacles group, axial length was elongated in 1 year period with a mean increase of $0.42{\pm}0.20mm$. The statistically significant suppression of axial elongation was observed in OK group compared to the spectacles group (Mann-Whitney U test, p < 0.05). For OK group, the age of starting OK (Pearson's correlation, r = -0.481, p < 0.05) was the only influencing factor on axial elongation, which had negative correlation with axial elongation. In spectacles group, the age of starting spectacles had negative correlation with axial elongation (Pearson's correlation, r = -0.462, p < 0.05) and baseline spherical equivalent, spherical diopter, cylindrical diopter from manifest refraction had positive correlation with axial elongation. Comparison of axial elongation in orthokeratology lens group and spectacles group by age groups (6 to 9 years [28 eyes], 9 to 13 years [47 eyes]), 9 to 13 years of orthokeratology lens group had the stronger suppression of axial elongation (Mann-Whitney U test, p < 0.05). Conclusions: The OK effectively suppresses axial elongation compared to the spectacles. Although the patients are in age from 9 to 13 years, the axial elongation was effectively suppressed.

Effects of Induced Dioptric Blur on Visual Acuity and Contrast Sensitivity (유발된 광학적 흐림이 시력과 대비감도에 미치는 영향)

  • Kim, Chang-Jin;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.261-270
    • /
    • 2014
  • Purpose: To study the effect of an artificially induced dioptric blur on acuity and contrast sensitivity using the $Optec^{(R)}$ 6500. Methods: Healthy 31 subjects aged $22.90{\pm}1.92$ (male 16, female 15) who were recruited from university students with 6/6 (20/20) or better corrected visual acuity and normal binocularity. They were measured objective and subjective refraction for full correction and dioptric blur using 0.00 ~ +3.00 D (+0.50 D steps) trial lenses and trial frame. They were measured binocularly visual acuity and contrast sensitivity with the $Optec^{(R)}$ 6500 (Stereo Optical Co., Inc., Chicago, Illinois, USA) under day conditions (photopic condition, $85cd/m^2$). Results: The higher dioptric blur, the less distance visual acuity and decrease rate of visual acuity. The higher dioptric blur, the less contrast sensitivity at all frequencies, and the peak of contrast sensitivity was shifted from middle frequency (6 cpd) to low frequency (1.5 cpd). When the visual acuity was best visual acuity to 0.77, there was the peak point at 6 cpd which was normal contrast sensitivity peak point. Conclusions: If the low refractive error is uncorrected or the refractive error is inappropriate, the contrast sensitivity is decreased and the peak point of contrast sensitivity frequency is shifted abnormally though small uncorrected refractive error. So it will be considered that regular eye test and decision of refractive error correction is important.

The Effect of Myopic Degree on the Change of Higher-order Aberrations Induced by Aging (근시도가 나이에 따라 유발되는 고위수차의 변화에 미치는 영향)

  • Ryu, Nam-Yul;Park, Kyoung-Hee;Kim, So-Ra;Park, Mi-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.353-362
    • /
    • 2014
  • Purpose: The present study was aimed to investigate the change of higher-order aberrations induced by aging and the effect of myopic degree on the correlation between age and higher-order aberrations. Methods: The higher-order aberrations in 931 eyes aged from 20 to 60 were measured by using a LADARWave device employing Hartmann-Shack system to analyze the effect of myopic degree measured by manifest refraction test on higher-order aberrations. Results: Coma and vertical coma aberrations were significantly decreased by the increase of myopic degree while vertical astigmatic aberration was significantly increased. The correlations of age and coma, vertical coma, spherical, vertical trefoil, horizontal trefoil, vertical astigmatic, horizontal astigmatic and vertical tetrafoil aberrations depended on the myopic degree, except for horizontal coma and horizontal tetrafoil aberrations. Conclusions: It is suggested to consider the myopic degree for the refractive correction including the laser surgery based on the present result that higher-order aberrations are affected by the myopic degree.

Survey on the Refractive Errors Status in the First Wearing Glasses (최초 안경착용시의 굴절이상 상태 조사)

  • Kim, Hye-Ran;Jang, Seong-Ju;Shim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.113-117
    • /
    • 2008
  • Purpose: This study is to survey that uncomfortable feeling of visual acuity in the first wearing glasses, the number of visiting in age, above vision ranging and refractive errors, astigmatism, and anisometropia. Methods: Automatic refraction and naked visual acuity test executed to receive prescription glasses that the man 509 and women's 499 people visited for the first time, among 3~15 years old who visited an ophthalmoiogical hospital, from January to December, 2003. Results: The first wearing glasses started 3 years old and the most cases was 8~9 years old when they were visited visual acuity 0.5 to 0.7 in most cases. Refractive errors appeared 8 years old and its most plentifully with 20.4%, 92.2% was myopia and 5.2% was hyperopia for the man. Also cases of women was 91.9% for myopia and 5.1% for the hyperopia. Spherical equivalent power was S-1.50${\pm}$1.10D and appeared 62.3% for the low myopia. Astigmatism was appeared 44.6% for the with the rule astigmatism and 75% was cylinder power lower than 1.00D. Cases of simple astigmatism need to glass when was cylinder power C-1.37${\pm}$1.01D, and C-0.50D appeared most distribution. More than 2.00D anisometropia appeared 2.3% for the whole subjective. Conclusions: Of the first wearing glasses visual acuity is 0.5~0.7, spherical equivalent power is S-1.50${\pm}$1.10D, cylinder power of simple astigmatism is C-1.37${\pm}$1.01D.

  • PDF

A Study on the Measures for Detection Error from the Displacement Distortion of the RADAR Waveform (레이더 전파의 왜곡현상에서 오는 탐지 오류 저감 방안 연구)

  • Kim, Jin Hieu;Kim, ChangEun;Lee, Yong-Soo
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.2 no.1
    • /
    • pp.36-44
    • /
    • 2019
  • $21^{st}$ century is digitally civilized era. Technologies such as AI, Iot, Big Data, Mobile and etc makes this era digitally advanced. These advancement of the technology greatly impacted detection range of the radar. Human's eye sight can see about 20Km and hear 20 ~ 20000 Hz. These limitations can be overcome using radar. This radar technology is used in military, aircraft, ship, vehicle and etc. to replace human eye. However, radar technology is capable of making False Alarm Rate. This document will propose the fix of these problems. Radar's distortion includes beam refraction, diffraction and reflection. These inaccurate data result in deterioration of human judgements and my cause various casualties and damages. Radar goes through annual testing to test how many false alarm is being produced. Normal radar usually makes 10 to 20 False alarms. In emergency situation, if operator were to follow this false alarm, this might result in following false object or take 12 more seconds to follow the right object. This problem can be overcome by using different radar data from different places and angles. This helps reduces False Alarm rate and track the object twice as fast.

Crossplot Interpretation of Electrical Resistivity and Seismic Velocity Values for Mapping Weak Zones in Levees (제방의 취약구간 파악을 위한 전기비저항과 탄성파속도의 교차출력 해석)

  • Cho, Kyoung-Seo;Kim, Jeong-In;Kim, Jong-Woo;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.31 no.4
    • /
    • pp.507-522
    • /
    • 2021
  • Specific survey objectives often cannot be met using only one geophysical method, as each method's results are influenced by the specific physical properties of subsurface materials. In particular, areas susceptible to geological hazards require investigation using more than one method in order to reduce risks to life and property. Instead of analyzing the results from each method separately, this work develops a four-quadrant criterion for classifying areas of levees as safe or weak. The assessment is based on statistically determined thresholds of seismic velocity (P-wave velocity from seismic refraction and S-wave velocity from multichannel analysis of surface waves) and electrical resistivity. Thresholds are determined by subtracting the standard deviation from the mean during performance testing of this correlation technique applied to model data of four horizontal and inclined fracture zones. Compared with results from the crossplot of resistivity and P-wave velocity, crossplot analysis using resistivity and S-wave velocity data provides more reliable information on the soil type, ground stiffness, and lithological characteristics of the levee system. A loose and sandy zone (represented by low S-wave velocity and high resistivity) falling within the second quadrant is interpreted to be a weak zone. This interpretation is well supported by the N values from standard penetrating test for the central core.

Investigation of the Environment and Working Scope of Optometric Personnel in Ophthalmology (안과검안인력의 근무 환경 및 업무 범위에 관한 조사)

  • Han, Minho;Park, Junbeom;Jeon, Okhwan;Hwang, Eul Sung;Park, Hyun Jin;Lee, Min Woo;Kim, Gibong;Koo, Bon-Kyeong;An, Younghoi
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.3
    • /
    • pp.224-238
    • /
    • 2022
  • The environment and scope of work of optometric personnel in ophthalmology are unknown. We aimed to investigate these topics using an online survey. Based on the results obtained, we also make policy proposals from the perspective of clinical laboratory technologists to the University-Association-Academy. The age distribution of the study subjects was as follows; 20s (40.7%), 30s (28.4%), 40s (23.5%), and 50s (7.4%). Women constituted 56.0% of the cohort, and careers were evenly distributed from <1 to ≥15 years. We found optometric personnel had high levels of work-related stress, frequent occupational diseases, and that their duties were wide in scope. More manpower is needed to reduce work stress and improve work satisfaction. Clinical laboratory technologists held more senior positions at 48% compared to others and the occupational distribution was closely related to the senior occupation (P<0.001). Clinical laboratory technologists were responsible for about 30 types of eye examinations, and the most frequently performed examination was the refraction test; anomaloscopic examinations took the most time (27 minutes). Taken together, clinical laboratory technologists perform various eye exams. Given the importance of clinical laboratory technologists in optometry, a multifaceted effort is required at the University-Association-Academy.

Correlations between Higher-order Aberrations and Myopic Degree (근시도와 고위수차와의 상관관계)

  • Ryu, Nam-Yul;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.199-206
    • /
    • 2014
  • Purpose: The present study was aimed to investigate the correlation between higher-order aberration and myopic degree by the analysis of fluctuation of high-order aberration according to the change of myopic degree in certain ranges of myopia and astigmatism. Methods: The high-order aberration in a total of 992 eyes was analyzed by using a LADARWave device employing Hartmann-Shack system, and the relation between high-order aberration and myopia by the change of myopic degree through manifest refraction test. Results: In all subjects, spherical aberration and total coma aberration were significantly increased by the increase of myopic degree, however, trefoil aberration and astigmatic aberration and tetrafoil aberration were decreased. With the group of lower myopic degree, the change of coma aberration was greater by myopic degree and its change was significantly different. The change of spherical aberration by myopic degree was greatly large in the a group of -3.00 D or more and the group of -6.00 D or more where as its change was not large in the group of lower than -3.00 D. The significant decrease of coma aberration was observed only in the group of astigmatic degree of -1.00 D or less when analyzing the correlation between the higher-order aberrations and myopia in the certain groups of astigmatic degree. In the case of spherical aberration, the significant change was shown in all astigmatic groups, however, its increase was larger with the increase of myopic degree in lower degree of astigmatism. The consistent relationship in variations of horizontal and vertical coma aberration in certain myopic and astigmatic groups was neither established nor statistically significant. Conclusions: It is concluded that the correlation between the higher-order aberration and low-order aberration obtained from the results of the present study can help the understanding related to vision quality and the improvement of vision quality.

Comparison and Analysis for the Effects of Functional Progressive Addition Lenses on Binocular Vision of University Students (기능성 누진가입도렌즈가 대학생들의 양안시기능에 미치는 영향 비교 분석)

  • Kim, Chang Jin;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.105-116
    • /
    • 2010
  • Purpose: To analyze and compare differences between single vision lenses and functional progressive addition lenses and improvement to binocular visual function wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses (EYE-T, Chemilens Co., Korea, ADD 0.750) for 2 months. Objective refraction, corrected visual acuity at distance and near, near point of convergence, near point of accommodation, accommodative facility, phoria at distance and near were measured. And subjective satisfaction was investigated by using a questionnaire designed to fatigue, comfort, discomfort, overall satisfaction and preference. Results: Functional progressive addition lenses were better than single vision lenses at near point of convergence and accommodation, accommodative facility. Exo phoria measured at distance with single vision and functional progressive addition lenses. Exo phoria measured at near with functional progressive addition lenses was higher than that with single vision lenses. As a survey, the satisfaction was increased in questions related near work. However, single vision lenses were preferred in distance test of overall satisfaction, easy 10 adapt, lime to adapt. A survey showed thai preference of functional progressive addition lenses were increased 75.00% to 81.26% for near work, 50.00% to 65.63% for visual fatigue, 47.75% to 50.00% for visual comfort and 31.25% to 46.88% for overall comfort. Conclusions: Comparing between single vision lenses and functional progressive addition lenses, binocular visual function related near work, subjective satisfaction and preference was improved after wearing functional progressive addition lenses. This study suggested that functional progressive addition lenses were useful for long time near work.