• Title/Summary/Keyword: reference value

Search Result 2,281, Processing Time 0.031 seconds

NO REFERENCE QUALITY ASSESSMENT OVER PACKET VIDEO NETWORK

  • Sung, Duk-Gu;Hong, Seung-Seok;Kim, Yo-Han;Kim, Yong-Gyoo;Park, Tae-Sung;Shin, Ji-Tae
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.250-253
    • /
    • 2009
  • This paper presents NR (No Reference) Quality assessment method for IPTV or mobile IPTV. Because No Reference quality assessment method does not access the original signal so it is suitable for the real-time streaming service. Our proposed method use decoding parameters, such as quantization parameter, motion vector, and packet loss as a major network parameter. To evaluate performance of the proposed algorithm, we carried out subjective test of video quality with the ITU-T P.910 ACR (Absolute Category Rating) method and obtained the mean opinion score (MOS) value for QVGA 180 video sequence coded by H.264/AVC encoder. Experimental results show the proposed quality metric has a high correlation (84%) to subjective quality.

  • PDF

A Variable Speed Control Scheme of a BLDC Motor for the High-Speed Blender Machine (고속 블렌더 머신용 BLDC 모터의 가변속 제어 방법)

  • Bae, Jongnam;Ahn, Jin-Woo;Lee, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.57-59
    • /
    • 2018
  • This paper presents a novel reference variable speed control scheme of a BLDC motor for the high-speed blender machine according to the current limit. Because of a pulsating load variation of a high-speed blender machine, the actual speed is pulsated by the current limit in the high-speed region. The proposed control scheme uses a variable reference speed to reduce the speed variation from the current limit in the constant power region. The pulsated load is occurred at the material crushing, then the pulsated load is reduced after grinding. The reference speed is smoothly reduced at the pulsated load variation, then the enough torque can make a constant speed during crushing. When the pulsating load is reduced, the reference speed is automatically increased to the original speed value. The proposed control scheme is verified by experimental result by practical blender machine.

  • PDF

Characteristics of Point-diffraction Interferometer for certification of high-precision optical system (고정밀 광학계 측정을 위한 점회절 간섭계의 특성 연구)

  • Lee, Kyeong-Hee;Choi, Young-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.138-139
    • /
    • 2007
  • The use of conventional Twyman and Fizeau interferometers inevitably fails in testing high precision optics because of errors always existing in reference elements producing the reference wavefront. Therefore it is necessary to apply to this task the interferometers of a radically new type, which are able to produce perfect reference wavefront with the help of light diffraction by a small obstacle or pinhole. In this paper new theoretical approaches and schematics of point diffraction interferometers are considered in detail with paying attention to constructive reliability. Such interferometers do not use reference optical surfaces and readily provide adequate estimation of errors and aberrations value of 0.01 wavelengths.

  • PDF

Precise Determination of Silicon in Ceramic Reference Materials by Prompt Gamma Activation Analysis at JRR-3

  • Miura, Tsutomu;Matsue, Hideaki
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.299-303
    • /
    • 2016
  • Prompt gamma activation analysis using a thermal neutron-guided beam at Japan Atomic Energy Agency JRR-3M was applied for the precise determination of Si in silicon nitride ceramic reference materials [Japan Ceramic Reference Material (JCRM) R 003]. In this study, the standard addition method coupled with internal standard was used for the nondestructive determination of Si in the sample. Cadmium was used as internal standard to obtain the linear calibration curves and to compensate for the neutron beam variability. The analytical result of determining Si in JCRM R 003 silicon nitride fine powder ceramic reference materials using prompt gamma activation analysis was in good agreement with that obtained by classical gravimetric analysis. The relative expanded measurement uncertainty (k = 2) associated with the determined value was 2.4%.

NURBS Interpolator with Recursive Method (재귀적 방법에 의한 NURBS 보간기)

  • Baek Dae Kyun;Ko Tae Jo;Lee Jeh Won;Kim Hee Sool
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.45-54
    • /
    • 2005
  • The purpose of this research is to find a simple and accurate NURBS interpolator for CNC systems such as robot, CMM and CNC machine tools. This paper presents a new design of NURBS interpolator for CNC system. The proposed algorithm used the recursive characteristics of NURBS equation, the previous incremental value and chord length for the sake of a constant chord length. Simulation study was conducted to see the performance of the proposed interpolator with reference-word and reference-pulse method. Consequently, an accurate and simple NURBS interpolator was possible for modem CNC systems.

Workpiece Horizontality and Reference Positioning of Cutting Tool by Measuring Impedance in Ultra-Precision-Machining (초정밀가공 시 임피던스 측정을 통한 시편 수평맞춤 및 공구의 기준위치 설정)

  • Lee, Ho-Cheol;Kim, Gi-Dae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.12
    • /
    • pp.1366-1371
    • /
    • 2011
  • In ultra precision machining, it is necessary to adjust the horizontality and reference position of a workpiece in a noncontact manner. For this, a simple process by measuring impedance between a tool tip and a workpiece which are connected to impedance analyzer is proposed. As the distance between the tool and the workpiece gets closer, the reduction rate of impedance becomes higher over all frequency ranges. By setting threshold value of impedance reduction rate at specific frequencies through preliminary experiments, the distance between the tool and the workpiece can be predicted and it directly enables us to horizontalize the workpiece and to set the tool to the desired reference position.

HSPICE Macro-Model and Midpoint-Reference Generation Circuits for MRAM (MRAM용 HSPICE 마크로 모델과 midpoint reference 발생 회로에 관한 연구)

  • 이승연;이승준;신형순
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.8
    • /
    • pp.105-113
    • /
    • 2004
  • MRAM uses magneto-resistance material as a storage element, which stores cell data as a polarization of spin in a free magnetic layer. This magneto-resistance material has hysteresis, asteroid curve at the thermal variation, and R-V characteristics for switching the data. Therefore, a macro-model which can reproduce these characteristics is required for MRAM simulation. We propose a macro-model of TMR (Tunneling Magneto Resistance) that can reproduce all of these characteristics on HSPICE. Also we propose a novel sensing scheme, which generates reference resistance having the medium value, ( $R_{H}$+ $R_{L}$)/2, for a wide range of applied voltage and present simulation results based on the HSPICE macro-model of MTJ that we have developed.d.d.

Chloride Diffusion Coefficient Model Considering the Initiation Time of Exposure to Chloride Environment (염소이온 노출개시시기를 고려한 기존 확산계수 모델 수정제안)

  • Kim, Ki-Hyun;Cha, Soo-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.377-386
    • /
    • 2009
  • A reference diffusion coefficient model from ACI life-365 is drawn from test results by NT build 443. This test method gives a time-averaged diffusion coefficient during immersion period, thus the ACI model uses the time-averaged diffusion coefficient as a reference value. ACI model needs to be revised, considering the difference between the time-average value and reference value at specified time. In this study, firstly the analytic solutions of diffusion equation are derived considering the initiation time and period of exposure to chloride, and secondly the time-averaged diffusion coefficient from NT build 443 is converted into the diffusion coefficient at reference time. From this study, the reference diffusion coefficient of ACI model should be modified to be about 10% larger values than those of present ACI model. For convenient design of service life, previous relationship between the chloride diffusion coefficient from NT build 443 and that from NT build 492 is also modified. To compare the chloride diffusion coefficients of ACI and JCI models, the reference chloride diffusion coefficient with respect to the JCI model is drawn in the similar form of ACI model's, and service life prediction by ACI life-365 method is confirmed to give a conservative result.

Establishment of Total Sugar Reference Value for Koreans (한국인 총당류 섭취기준 설정)

  • Cho, Sung-Hee;Chung, Chin-Eun;Kim, Sun-Hee;Chung, Hye-Kyung
    • Journal of Nutrition and Health
    • /
    • v.40 no.sup
    • /
    • pp.3-8
    • /
    • 2007
  • Sugars are a ubiquitous component of our food supply and are consumed as a naturally occurring component of many foods and as additions to foods during processing, preparation, or at the table. Most fruits and dairy products are high in sugars and thus naturally occurring sugars are consumed as part of a healthy diet. Some countries developed recommended daily intake figures(daily values : DVs or guideline daily amounts: GDA) for nutrients, and some countries, but not most have developed DV/GDA for total sugars. Dietary Reference Intakes for Koreans established by the Korean Nutrition Society in 2005, did not include the reference values for total sugar or added sugar. The committee on Dietary Reference Intakes for sugar was constituted in 2006 and discussed whether to special added sugars or total sugar. Although added sugars are not chemically or physiologically different from naturally occurring sugars, many foods and beverages that are major sources of added sugars have lower micronutrient densities compared with foods and beverages that are major sources of naturally occuring sugars. But it was so hard to calculate a dietary intake of added sugar for Korean people, because there was insufficient information about contents of added sugar during processing or preparation of Korean food. Currently Korean or US food labels contain information on total sugars per serving but do not distinguish between sugars naturally present in food and added sugars. Therefore the committee decided to set the reference value for total sugar for Koreans. According to the recommended diet pattern for Koreans suggested by the Korean Nutrition Society, estimated sugar intake from the sugar containing food based on 2,000 kilocalories is 67 g or 13% of total energy. Based on the data available on risk of obesity, hypertension, hyperlipidemia, insulin resistance, and metabolic syndrome from the analysis of Korean NHANES, it was insufficient evidence to set a UL for total sugar, but tended to increase serum LDL cholesterol and obesity at over 20-25% of energy from total sugar when consumed with high carbohydrates. Therefore the committee on Dietary Reference Intakes for sugar set the Acceptable Macronutrient Distribution Range for total sugar as 10-20% of total energy intake.

Validity of Weight and Height as a Nutritional Status Measurement for Adults in Kuri City

  • Kim, Youngok;Lee, Soon-Young
    • Journal of Community Nutrition
    • /
    • v.1 no.1
    • /
    • pp.39-43
    • /
    • 1999
  • Anthropometric measurements, particularly weight and height, are the most commonly employed measures of nutritional status in epidemiologic studies because of their simplicity and ease of collection. However, the usefulness of the anthropometric indicator is controversial. The aim of this study was to evaluate the usefulness of the anthropometric indicator to represent the nutritional status of individual adult in epidemiologic studies. In order to evaluate the usefulness of the anthropometric indicator to represent the nutritional status of individual, the validity in terms of sensitivity and specificity of anthropometric indicators was estimated by comparing the biochemical indicators to the reference indicators. The relative validity of dietary intake indicators was also measured for comparison between the three indicators of biochemistry, anthropometry and dietary assessment. The results showed that sensitivity of weight and height and dietary indicators were 16.7 an 50.5, respectively comparing the reference value of 100 as biochemical indicator in identifying anemic adults. Whereas the sensitivity of weight and height and dietary indicators were 63.6 and 36.4, respectively comparing reference value of 100 in identifying hyperlipidemic individuals(obesity). In conclusion, the validity of weight and height is much lower than that of biochemical indicator, burt weight and height still has some usefulness in identifying anemic individuals. Especially, it is more useful in identifying hyperlipidemic individual adults thant in identifying anemic individuals.

  • PDF