• Title/Summary/Keyword: reference value

Search Result 2,286, Processing Time 0.027 seconds

Determining the Reference Voltage of 345 kV Transmission System Considering Economic Dispatch of Reactive Power (무효전력 경제급전을 고려한 345㎸ 송전계통의 기준 전압 설정 방법)

  • Hwang, In-Kyu;Jin, Young-Gyu;Yoon, Yong-Tae;Choo, Jin-Boo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.5
    • /
    • pp.611-616
    • /
    • 2018
  • In the cost based pool market in Korea, there is no compensation of reactive power because the fuel cost for reactive power is relatively low compared to that of active power. However, the change of energy paradigm in the future, such as widespread integration of distributed renewable energy source, will prevent the system operator from mandating the reactive power supply without any compensation. Thus, in this study, we propose the reference voltage of the 345 kV transmission system that minimizes the reactive power supply. This is closely related to the economic dispatch of reactive power aiming at minimizing the compensation cost for the reactive power service. In order to verify the effectiveness of the proposed reference voltage, the simulations are performed using the IEEE 14 bus system and the KEPCO real networks. The simulation results show that a voltage lower than the current reference value is recommended to reduce the reactive power supply and also suggest that the current voltage specification for the 345 kV system needs to be reviewed.

Development of Dry-type Surface Myoelectric Sensor for the Shape of the Reference Electrode and the Inter-Electrode Distance (기준전극의 형상과 입력전극사이의 간격을 고려한 건식형 표면 근전위 센서 개발)

  • Choi, Gi-Won;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.550-557
    • /
    • 2006
  • This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. In this paper is proposed two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material of the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value(MAV) circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.

A novel reference model for dental scanning system evaluation: analysis of five intraoral scanners

  • Karakas-Stupar, Irina;Zitzmann, Nicola Ursula;Joda, Tim
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.2
    • /
    • pp.63-69
    • /
    • 2022
  • PURPOSE. The aim of this in vitro study was to investigate the accuracy (trueness and precision) of five intraoral scanners (IOS) using a novel reference model for standardized performance evaluation. MATERIALS AND METHODS. Five IOSs (Medit i500, Omnicam, Primescan, Trios 3, Trios 4) were used to digitize the reference model, which represented a simplified full-arch situation with four abutment teeth. Each IOS was used five times by an experienced operator, resulting in 25 STL (Standard Tessellation Language) files. STL data were imported into 3D software (Final Surface®) and examined for inter- and intra-group analyses. Deviations in the parameter matching error were calculated. ANOVA F-test and Kruskal-Wallis test were applied for inter-group comparisons (α = .05); and the coefficient of variation (CV) was calculated for intra-group comparisons (in % ± SD). RESULTS. Primescan (matching error value: 0.015), Trios 3 (0.016), and Trios 4 (0.018) revealed comparable results with significantly higher accuracy compared to Medit i500 (0.035) and Omnicam (0.028) (P < .001). For intra-group comparison, Trios 4 demonstrated the most homogenous results (CV 15.8%). CONCLUSION. The novel reference model investigated in this study can be used to assess the performance of dental scanning technologies in the daily routine setting and in research settings.

Fast Multi-Reference Frame Motion Estimation Algorithm Using a Relation of Motion Vector with Distance of Each Reference Frame (움직임 벡터와 참조 프레임간의 거리를 이용한 고속 다중 참조 프레임 움직임 추정)

  • Byun, Ju-Won;Choi, Jin-Ha;Kim, Jae-Seok
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.2
    • /
    • pp.69-76
    • /
    • 2010
  • This paper proposed a new fast multi-reference frame motion estimation algorithm. The proposed algorithm reduces search areas of motion estimation using a linear relation of motion vector with distance of each reference frame. New algorithm executes full search area motion estimation in reference frame 0 and reference frame 1. After that, search areas in reference frame 2, reference frame 3 and reference frame 4 are minimized by distance of each reference frame and results of motion estimation in reference frame 0 and reference frame 1. The proposed algorithm does not use a threshold value which is obstacle of hardware implementation and processing time schedule. Also, it reduced computation quantity of multi-reference motion estimation. Hardware implementation of multi-reference frame motion estimation is possible by these features. Simulation results show that PSNR drop and bitrate increase of proposed algorithm are lower than those of previous fast multi-reference frame motion estimation algorithm The number of computation of new algorithm is reduced 52.5% and quality of result is negligible when compared with full search area motion estimation which has 5 reference frames.

A Study on the Measurement and Determination of External Loop Impedance on TN-C-S System (TN-C-S 접지계통에서 외부 루프 임피던스의 실측 및 기준값 설정에 관한 연구)

  • Yi, Geon-Ho;Jung, Jin-Soo;Moon, Hyun-Wook;Kim, Sun-Gu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1163-1168
    • /
    • 2013
  • The maximum allowable value of loop impedance($Z_s$) to secure the operation of overcurrent protective devices and the safety for indirect contact is a very important in TN-C-S system. The loop impedance is divided into inner loop impedance which consumer can adjust and external loop impedance($Z_e$) which only electric operator can adjust. Thus, an external loop impedance which limits to less than a certain value is a very important factor for human body protection against electric shock in TN-C-S system. The concept of loop impedance($Z_s$) is recently introduced to the domestic, the study about external loop impedance is yet insufficient. However, the study about the reference impedance as specified by the IEC 60725 standard to improve the quality and reliability of the power supply is being made. In this paper, reference value of external loop impedance($Z_e$) to meet domestic environment will be proposed by the nationwide measurement and statistical analysis.

Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method

  • Jeong, Yoo-Geum;Lee, Wan-Sun;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.245-251
    • /
    • 2018
  • PURPOSE. To evaluate the accuracy of a model made using the computer-aided design/computer-aided manufacture (CAD/CAM) milling method and 3D printing method and to confirm its applicability as a work model for dental prosthesis production. MATERIALS AND METHODS. First, a natural tooth model (ANA-4, Frasaco, Germany) was scanned using an oral scanner. The obtained scan data were then used as a CAD reference model (CRM), to produce a total of 10 models each, either using the milling method or the 3D printing method. The 20 models were then scanned using a desktop scanner and the CAD test model was formed. The accuracy of the two groups was compared using dedicated software to calculate the root mean square (RMS) value after superimposing CRM and CAD test model (CTM). RESULTS. The RMS value ($152{\pm}52{\mu}m$) of the model manufactured by the milling method was significantly higher than the RMS value ($52{\pm}9{\mu}m$) of the model produced by the 3D printing method. CONCLUSION. The accuracy of the 3D printing method is superior to that of the milling method, but at present, both methods are limited in their application as a work model for prosthesis manufacture.

Recovery of Ecosystem Service Functions through Ecological Restoration Practice: A Case Study of Coal Mine Spoils, Samcheok, Central Eastern Korea (훼손된 생태계의 복원을 통한 생태계 서비스의 회복: 채탄쓰레기 매립지 복원지의 사례)

  • Oh, Woo Seok;Lee, Chang Seok
    • Korean Journal of Environmental Biology
    • /
    • v.32 no.2
    • /
    • pp.102-111
    • /
    • 2014
  • Ecological restoration is regarded as a major strategy for preventing biodiversity loss and thereby enhancing ecosystem service. This study was performed to evaluate ecosystem service value that the restored ecosystem provides. Ecosystem service was evaluated for provisioning and regulating services. The former service was evaluated by comparing similarities in a viewpoint of floristic composition to the reference site between the restored and the unrestored sites. Species composition of the restored site was found to be more similar to the reference site than that of the unrestored site and thereby restoration practice contributed for enhancing the provisioning service. Regulating service was evaluated based on microclimate control, soil amelioration, and improvement of water holding capacity. The value of ecosystem services in terms of microclimate control, soil amelioration, and improvement of water holding capacity was higher in the restored site than in the unrestored site. In consequence, ecological restoration of coal mine spoils contributed for enhancing the ecosystem service value of the corresponding site and thereby is rewarding the cost invested for restoration.

Comparison of Wind Pressure Coefficient and Wind Load Standard for Cladding in a Retractable Dome Roof by Wind Tunnel Test (풍동 실험을 통한 개폐식 돔 지붕의 외장재용 풍압 계수와 풍하중 기준 비교)

  • Cheon, Dong-jin;Kim, Yong-Chul;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.125-132
    • /
    • 2018
  • The biggest impact on the cladding design of buildings is wind loads. Wind tunnel tests were conducted to examine the applicability of current wind load standards about membrane retractable roof spatial structure. A dome model with a circular shape that is retractable to the center of the dome was made (Opening ratio = 0, 10, 30, 50). In addition, height adjustable turntables were made and tested with five patterns with H/D = 0.1, 0.2, 0.3, 0.4 and 0.5. The maximum wind pressure coefficient and the minimum wind pressure coefficient for the cladding were analyzed and the experimental wind pressure coefficient were compared with the current wind load standards, KBC2016 and AIJ-RLB(2015). The experimental value and the reference value of the enclosed roof were very similar and showed possibility of application, but opened roof case was found that the reference value was underestimated.

A study on the stage image of "rebound lute behind the back" in Dunhuang, China

  • Xueliang Zong;Ziwei Li;Qingfeng Zhang
    • International Journal of Advanced Culture Technology
    • /
    • v.12 no.2
    • /
    • pp.16-29
    • /
    • 2024
  • Mogao Grottoes in Dunhuang, China is one of the world cultural heritage, is the largest ancient grottoes art group in the world, and is a natural and cultural place with outstanding universal value for mankind all over the world. Dunhuang music and dance derived from the murals of Mogao Grottoes is an artistic representation of its thousand-year-old glorious history and an indispensable historical material for research. As one of the iconic images of Dunhuang music and dance, the "rebound lute behind the back" dance posture has unique charm value both in the original mural composition and the stage image. This paper analyzes the characters holding pipa in Dunhuang murals by case analysis, comparative research and other relevant research methods, then studies the stage image and posture of "rebound lute behind the back", and finally analyzes the stage works of "rebound lute behind the back". It is concluded that the dance image of "rebound lute behind the back" is a dynamic stage art work gradually formed by artists from the static Dunhuang murals through refining, developing, processing and transforming. This is to revive the image of Dunhuang music and dance murals, to provide reference and reference for the inheritance and development of Dunhuang culture, and then to enhance and enrich the artistic value of excellent traditional Chinese culture and world cultural heritage.

Error Rate Analysis according to Setting of the Reference Point for Calculating the Flood Runoff that using Surface Image Velocimeter (SIV) (표면영상유속계(SIV)를 활용한 홍수유출량 산정 시 참조점 설정에 따른 오차율 분석)

  • Kim, Yong-Seok;Yang, Sung-Kee
    • Journal of Environmental Science International
    • /
    • v.25 no.6
    • /
    • pp.799-815
    • /
    • 2016
  • In this study, according to the reference setting based on the runoff video of 9:00 where the highest water level of 3.94 m has been recorded during the runoff of Cheon-mi Stream in Jeju Island by the attack of Typhoon no. 16 Sanba on September $17^{th}$, 2012, the error rate of long-distance and short-distance velocimetry and real-distance change rate by input error have been calculated and the input range value of reference point by stream has been suggested. In the reference setting process, if a long-distance reference point input error occurs, the real-distance change rate of 0.35 m in the x-axis direction and 1.35 m in y-axis direction is incurred by the subtle input error of 2~11 pixels, and if a short-distance reference point input error occurs, the real-distance change rate of 0.02 m in the x-axis direction and 0.81 m in y-axis direction is incurred by the subtle input error of 1~11 pixels. According to the long-distance reference point setting variable, the velocity error rate showed the range of fluctuation of at least 14.36% to at most 76.06%, and when calculating flux, it showed a great range of fluctuation of at least 20.48% to at most 78.81%.