• Title/Summary/Keyword: reference series

Search Result 516, Processing Time 0.024 seconds

The use of linear stochastic estimation for the reduction of data in the NIST aerodynamic database

  • Chen, Y.;Kopp, G.A.;Surry, D.
    • Wind and Structures
    • /
    • v.6 no.2
    • /
    • pp.107-126
    • /
    • 2003
  • This paper describes a simple and practical approach through the application of Linear Stochastic Estimation (LSE) to reconstruct wind-induced pressure time series from the covariance matrix for structural load analyses on a low building roof. The main application of this work would be the reduction of the data storage requirements for the NIST aerodynamic database. The approach is based on the assumption that a random pressure field can be estimated as a linear combination of some other known pressure time series by truncating nonlinear terms of a Taylor series expansion. Covariances between pressure time series to be simulated and reference time series are used to calculate the estimation coefficients. The performance using different LSE schemes with selected reference time series is demonstrated by the reconstruction of structural load time series in a corner bay for three typical wind directions. It is shown that LSE can simulate structural load time series accurately, given a handful of reference pressure taps (or even a single tap). The performance of LSE depends on the choice of the reference time series, which should be determined by considering the balance between the accuracy, data-storage requirements and the complexity of the approach. The approach should only be used for the determination of structural loads, since individual reconstructed pressure time series (for local load analyses) will have larger errors associated with them.

Time-series Analysis of Geodetic Reference Frame Aligned to International Terrestrial Reference Frame

  • Bae, Tae-Suk;Hong, Chang-Ki;Lee, Jisun;Altamimi, Zuheir;Sillard, Patrick;Boucher, Claude
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.5
    • /
    • pp.313-319
    • /
    • 2021
  • The national geodetic reference frame of Korea was adopted in 2003, which is referenced to ITRF (International Terrestrial Reference Frame) 2000 at the epoch of January 1, 2002. For precise positioning based on the satellites, it should be thoroughly maintained to the newest global reference frame. Other than plate tectonic motion, there are significant events or changes such as earthquakes, antenna replacement, PSD (Post-Seismic Deformation), seasonal variation etc. We processed three years of GNSS (Global Navigation Satellite System) data(60 NGII CORS stations, 51 IGS core stations) to produce daily solutions minimally constrained to ITRF. From the time series of daily solutions, the sites with unexpected discontinuity were identified to set up an event(mostly antenna replacement). The combined solution with minimum constraints was estimated along with the velocity, the offsets, and the periodic signals. The residuals show that the surrounding environment also affects the time series to a certain degree, thus it should be improved eventually. The transformation parameters to ITRF2014 were calculated with stability and consistency, which means the national geodetic reference frame is properly aligned to the global reference frame.

Simplified Control Scheme of Unified Power Quality Conditioner based on Three-phase Three-level (NPC) inverter to Mitigate Current Source Harmonics and Compensate All Voltage Disturbances

  • Salim, Chennai;Toufik, Benchouia Mohamed
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.544-558
    • /
    • 2013
  • This paper proposes a simplified and efficient control scheme for Unified Power Quality Conditioner (UPQC) based on three-level (NPC) inverter capable to mitigate source current harmonics and compensate all voltage disturbances perturbations such us, voltage sags, swells, unbalances and harmonics. The UPQC is designed by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The dc voltage is maintained constant using proportional integral voltage controller. The shunt and series AF are designed using a three-phase three-level (NPC) inverter. The synchronous reference frame (SRF) theory is used to get the reference signals for shunt and the power reactive theory (PQ) for a series APFs. The reference signals for the shunt and series APF are derived from the control algorithm and sensed signals are injected in tow controllers to generate switching signals for series and shunt APFs. The performance of proposed UPQC system is evaluated in terms of power factor correction and mitigation of voltage, current harmonics and all voltage disturbances compensation in three-phase, three-wire power system using MATLAB-Simulink software and SimPowerSystem Toolbox. The simulation results demonstrate that the proposed UPQC system can improve the power quality at the common connection point of the non-linear load.

Hybrid-Type Active Power Filters for Compensating Harmonic Current and Unbalanced Source Voltages (고조파 전류와 불평형 전원전압 보상을 위한 복합형 능동전력 필터)

  • Lee, Ji-Myeong;Lee, Dong-Chun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.5
    • /
    • pp.249-257
    • /
    • 2002
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for the combined system of series active and shunt passive power filter is proposed, where no low/high-pass filters are used in deriving the reference voltage for compensation. The phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. In order to remove the phase delay in generating the reference voltage for compensation, the reference of 5th and 7th harmonic components is predicted one-sampling ahead. The validity of the proposed scheme has been verified for 3[kVA] proto-type active power filter system.

A Study on the Over-Current Protection Method of A Series Active Compensator (직렬 능동 보상기의 과전류 보호방법에 관한 연구)

  • Chae, Beom-Seok;Lee, U-Cheol;Lee, Taek-Gi;Hyeon, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.321-329
    • /
    • 2002
  • A protection scheme for series active compensator is presented and analyzed in this paper. The proposed series active compensator operated as a high impedance K($\Omega$) to the fundamentals when short-circuit faults occur in the power distribution system, and two control strategies are proposed in this paper The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame(SRF). When the short-circuit faults occur in the power distribution system, the proposed scheme can protect the series active compensator without additional protection circuits. The validity of the Proposed Protection scheme was investigated through experimental results.

Low Power SAR ADC with Series Capacitor DAC (직렬 커패시터 D/A 변환기를 갖는 저전력 축차 비교형 A/D 변환기)

  • Lee, Jeong-Hyeon;Jin, Yu-Rin;Cho, Seong-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.90-97
    • /
    • 2019
  • The charge redistribution digital-to-analog converter(CR-DAC) is often used for successive approximation register analog-to-digital converter(SAR ADC) that requiring low power consumption and small circuit area. However, CR-DAC is required 2 to the power of N unit capacitors to generate reference voltage for successive approximation of the N-bit SAR ADC, and many unit capacitors occupy large circuit area and consume more power. In order to improve this problem, this paper proposes SAR ADC using series capacitor DAC. The series capacitor DAC is required 2(1+N) unit capacitors to generate reference voltage for successive approximation and charges only two capacitors of the reference generation block. Because of these structural characteristics, the SAR ADC using series capacitor DAC can reduce the power consumption and circuit area. Proposed SAR ADC was designed in CMOS 180nm process, and at 1.8V supply voltage and 500kS/s sampling rate, proposed 6-bit SAR ADC have signal-to-noise and distortion ratio(SNDR) of 36.49dB, effective number of bits(ENOB) of 5.77-bit, power consumption of 294uW.

Linearization and harmonic analysis of output voltages in overmodulation range of space vector PWM (공간벡터 PWM에서 과변조시 출력전압의 선형화 및 고조파 분석)

  • 이지명;이동춘
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.118-124
    • /
    • 1998
  • This paper describes a relationship of a space vector PWM and a sinusoidal PWM and presents that the space vector PWM can produce linearly the output voltage to the unity MI(modulation index). At first, reference angles and holding angles are derived from expanding a Fourier series of the reference voltage waveform and then the angles are used for the inverter switching to linearize transfer characteristics of the inverter. In addition, the harmonic components of the output voltage are analyzed and on-line control is shown to be feasible by approximating in piecewise-linearization the reference and holding angles versus the MI. In V/f control of the induction motor, it is verified by the experiment that the motor current is changed smoothly for the variation of the inverter input voltage and the change of the reference voltage.

Interactive Judgemental Adjustment of Initial Forecasts with forecasting Support Systems (예측지원시스템에 의한 직관적 예측의 행태에 관한 연구)

  • Lim, Joa-Sang;Park, Hung-Kook
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.24 no.1
    • /
    • pp.79-98
    • /
    • 1999
  • There have been a number of empirical studios on the effectiveness of Judgmental adjustment to statistical forecasts Generally the results have been mixed. This study examined the impact of the reliability and the source of the additionally presented reference forecast upon the revision process in a longitudinal time series forecasting task with forecast support systems. A 2-between(reliability & source). 2-within(seasonality & block) factorial experiment was conducted with post-graduate students using real time series. Judgmental adjustment was found to improve the accuracy of initial eyeballing irrespective of the reliability of an additionally presented forecast. But it did not outperform the dampened reference forecast. No effect was found of the way the source of the reference forecast was framed. Overall the subjects anchored heavily on their Initial forecast and relied too little on the reference forecast irrespective of its reliability. Moreover they did not improve at the task over time, despite immediate outcome feedback.

  • PDF

DQ Synchronous Reference Frame Model of a Series-Parallel Tuned Inductive Power Transfer System (직렬-병렬 공진 무선전력전송 시스템의 동기 좌표계 모델)

  • Noh, Eun-Chong;Lee, Sang-Min;Lee, Seung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.6
    • /
    • pp.477-483
    • /
    • 2020
  • This study proposes a DQ synchronous reference frame model of a series-parallel tuned inductive power transfer (SP-IPT) system. The wireless power transmission system experiences control difficulty because the transmitter-side controller cannot directly measure the receiver-side load voltages and currents. Therefore, a control-oriented circuit model that shows the dynamics of the IPT system is required to achieve a well-behaved controller. In this study, an equivalent circuit model of the SP-IPT system in a synchronously rotating reference frame is proposed using the single-phase DQ transformation technique. The proposed circuit model is helpful in modeling the dynamics of the voltages and currents of the transmitter- and receiver-side resonant tanks and loads. The proposed circuit model is evaluated using frequency- and time-domain simulation results.

NOTES ON FORMAL MANIPULATIONS OF DOUBLE SERIES

  • Choi, June-Sang
    • Communications of the Korean Mathematical Society
    • /
    • v.18 no.4
    • /
    • pp.781-789
    • /
    • 2003
  • Formal manipulations of double series are useful in getting some other identities from given ones and evaluating certain summations, involving double series. The main object of this note is to summarize rather useful double series manipulations scattered in the literature and give their generalized formulas, for convenience and easier reference in their future use. An application of such manipulations to an evaluation for Euler sums (in itself, interesting), among other things, will also be presented to show usefulness of such manipulative techniques.