Comparison of the accuracy of domestic dental intra-oral scanner(e-scanner) and model scanner (국산 치과용 구강스캐너(e-scanner)와 모델스캐너의 정확도 비교)

  • Kim, Busob;Kim, Jungho
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.53-61
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the discrepancy of scan process in dental intra oral scanner by comparing model scanner and anticipate possibility to introduce intra oral scan technique. Methods: 3D superimposition test was conducted to compare the scan discrepancy. The scanners used in this study are the e-oral scanner, the D750 model scanner, and the high precision CMM(3D Coordinate Measuring Machine). The standard of accuracy verification is ISO 5725-1; trueness and precision. Master model was manufactured by dental stone and scanned 5 times by intra oral, model scanner. Reference data was scanned 5 times by high accuracy CMM to evaluate the trueness. Results: Trueness of D750 scanner were $7.4{\mu}m$ $5.1{\mu}m$ $6.8{\mu}m$ at an abutment, an occluasal, a specific area. and trueness of e-scanner were $20.2{\mu}m$ $27.4{\mu}m$ $37.8{\mu}m$ at an abutment, an occluasal, a specific area. Precision of D750 scanner was $7.04{\mu}m$, e-scanner was $15.95{\mu}m$. Conclusion: When conducting in vitro test, The mean difference of trueness between e-scanner and D750 were $12.8{\mu}m$ at an abutment area, $22.3{\mu}m$ at an occlusal area, $31.0{\mu}m$ at a specific area and $8.91{\mu}m$ in precision. The scan discrepancies are within the range of clinical acceptance.

Intraoral Scan for Virtual Skull-Dentition Hybrid Images of Young Patients (가상 골격-치열 하이브리드 이미지 생성을 위한 구강 스캐너의 활용)

  • Lee, Joohee;Yang, ByoungEun;Lee, Hyelim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.57-64
    • /
    • 2022
  • Additional dentition images are needed because the dentitions are distorted in cone-beam computed tomography (CBCT) due to streak artifacts and non-uniformity of the x-ray beam. The purpose of this study is to evaluate the feasibility of improving the dentition image of CBCT scan with intraoral scanner instead of plaster models. Maxilla images from plaster models, two intraoral scanners, and CBCT of 20 patients aged 12 to 18 were used in this study. With one of the intraoral scanners, the full arch was scanned by three segments and combined into a complete full arch. Virtual skull-dentition hybrid images from intraoral scanners were superimposed with the images from plaster models to evaluate the coordinate value difference and distance at reference points. The results showed that the coordinate value difference and distance were smallest with segmented intraoral scan, which showed only 2 ㎛ distance. Intraoral scan may provide good dentition images for virtual skull-dentition images.

Computerization of Ultrasonic Scanner (초음파 주사장치의 Computer화)

  • Kim, Young-Hwan;Kim, Young-Gil;Lee, Se-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.4 no.2
    • /
    • pp.15-19
    • /
    • 1985
  • Computerization of ultrasonic scanner is considered to achieve more quantitative and reliable ultrasonic testing. Testech LS-24 ultrasonic scanner is modified, and step motors in this modified ultrasonic scanner are driven by multiprogrammer controlled by computer. Two step motors can be controlled independently and simultaniously. The performance of computerized ultrasonic scanner is examined entloying modified C scan for a flat bottom hole ultrasonic reference block.

  • PDF

A Study on the Ultrnsonic Distance Amplitude Characteristics Curve for Weld Defects Evaluation of Titanium Weld Zone (티타늄 용접부의 용접결함평가를 위한 초음파거리진폭특성곡선에 관한 연구)

  • Yi, Won;Park, Hee-Dong;Yun, In-Sik
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.7-12
    • /
    • 2008
  • This study proposes integrity evaluation method of weld zone in titanium using titanium distance amplitude characteristics curve(TDACC) and ultrasonic signals. For these purposes, the ultrasonic signals for porosity defects of weld zone in titanium are acquired in the type of time series data and echo strength. 4 lines in the DACC indicated damage evaluation standard of weld zone in titanium. The acquired ultrasonic signals agree fairly well with the measured results of reference block and sensitivity block(defect location, bean1 propagation distance, echo strength, etc). The proposed TDACC in this study agree fairy well with the measured results of weld zone in titanium(weld defects as porosity). The proposed TDACC in this study can be used for integrity evaluation of weld zone in titanium.

Development of a Inspection System for the Metal Mask Using a Vision System

  • Choi, Kyung-jin;Park, Chong-Kug;Lee, Yong-Hyun;Park, Se-Seung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.140.2-140
    • /
    • 2001
  • In this paper, we develop the system which inspects the metal mask using area scan camera and belu type xy-table and introduce its inspection algorithm. Thes whole area of the metal mask is divides into several inspection block and the sixe of a inspection block is decided by FOV(Field of View). To compare with the camera image of each block, the reference image is made by gerber file. The ratation angle of the metal mask is calculated through the linear equation that is substituted two end points of horizontal boundary of a specific hole in a camera image for. To calculate the position error caused by belt type xy-table, hough-transform using the distances among the holes in two images os used. The center of the reference image is moved as much as the calculated position error to be coincide with the camera image ...

  • PDF

Three-dimensional analysis of the outcome of different scanning strategies in virtual interocclusal registration

  • Jiansong, Mei;Liya, Ma;Jiarui, Chao;Fei, Liu;Jiefei, Shen
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.369-378
    • /
    • 2022
  • PURPOSE. The purpose of this in vitro study was to assess whether scanning strategies of virtual interocclusal record (VIR) affect the accuracy of VIR during intraoral scanning. MATERIALS AND METHODS. Five pairs of reference cubes were added to the digital upper and lower dentitions of a volunteer, which were printed into resin casts. Subsequently, the resin casts were articulated in the maximal intercuspal position in a mechanical articulator and scanned with an industrial computed tomography system, of which the VIR was served as a reference VIR. The investigated VIR of the upper and lower jaws of the resin master cast were recorded with an intraoral scanner according to 9 designed scanning strategies. Then, the deviation between the investigated VIRs and reference VIR were analyzed, which were measured by the deviation of the distances of six selected reference points on the upper reference cubes in each digital cast to the XY-plane between the investigated VIRs and reference VIR. RESULTS. For the deviation in the right posterior dentitions, RP group (only scanning of right posterior dentitions) showed the smallest deviation. Besides, BP group (scanning of bilateral posterior dentitions) showed the smallest deviation in the left posterior dentitions. Moreover, LP group (scanning of left posterior dentitions) showed the smallest deviation in the anterior dentitions. For the deviation of full dental arches, BP group showed the smallest deviation. CONCLUSION. Different scanning strategies of VIR can influence the accuracy of alignment of virtual dental casts. Appropriate scanning strategies of VIR should be selected for different regions of interest and edentulous situations.

Ultrasonic Test Criterion for the Explosively Welded Fe-Naval Brass Bonding Quality (초음파법에 의한 폭발접합 이종금속 접합품질 판정레벨 설정에 관한 연구)

  • 장영권;백영남
    • Journal of Welding and Joining
    • /
    • v.19 no.1
    • /
    • pp.40-48
    • /
    • 2001
  • An ultrasonic test method, as a nondestructive test is applied to ensure the clad interface quality assessment. According to the reference codes and standards, not only korea Industrial Standard(KS) but also American Society for Testing and Materials (ASTM) Standard, ultrasonic examination procedures use the pulse-echo, A-scan, back reflection signal drop method and/or side drilled reference hole used to establish the acceptance criteria of clad material test. But the variety of bonding materials and sizes makes it difficult to produce the reference blocks, or thus the criteria. In order to overcome these practical difficulties, new ultrasonic testing criterion is suggested. In this new method, the theoretical interface reflection signal amplitude level is calculated and suggested as an acceptance criteria with the back reflection signal set to 100% FSH(Full Screen Height) which is based on acoustic impedance mismatch at the clad interface for the explosive clad ultrasonic inspection. Applicability of suggested criterion, for the explosive clad Fe-Naval Brass with different bonding quality is confirmed to the pre-existed KS and ASTM specifications and verified by using SEM (Seanning Electron Microscope) micrograph. The results obtained by the suggested method is more conservative than the results according to the KS B 0234 and ASTM A 578 specifications The suggested method could be applicable to any other combination of explosive clad ultrasonic inspection.

  • PDF

Nondestructive Evaluation of Adhesive Bonding Quality by Measurements of Peak Amplitude of Simulated Stress Wave (모의 음향 방출 신호의 Peak Amplitude측정을 통한 복합 재료 접합부의 비파괴평가)

  • Son, Y.H.;Lee, J.O.;Lee, S.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.357-363
    • /
    • 1995
  • Disbond size of adhesively bonded single lap and double lap joints CFRP composite specimens has been evaluated using acousto-ultrasonic(AU) technique. Frequency spectra for all specimens were obtained by measuring peak amplitude of the stress wave propagated through the bond-lines. By analyzing these frequency spectra, peak amplitude was found to be proportional to fractional bonding area and to be maxima at the fundamental and the third order higher harmonic frequencies of specimen thickness mode. The disbond size can be evaluated quantitatively and this technique can be applied to real structures if the reference specimens are prepared in advancve.

  • PDF

Restoration of Landsat ETM+ SLC-off Gaps Using SPOT Image (SPOT 영상을 이용한 Landsat-7의 SLC-off 영상 복원)

  • Kim Hye-Jin;Yu Ki-Yun;Kim Yong-Il
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.229-234
    • /
    • 2006
  • On May 31, 2003. Landsat 7 experienced an anomaly causing the Scan Line Corrector(SLC) to stop functioning normally. The SLC-off causes individual scan lines to alternately overlap and then leave large gaps at the edge of the Image. A many scientists with ongoing experience using ETM+ data evaluated the scientific usability and validity of Landsat 7 products containing the SLC anomaly The best reference scene for gap-filling is the other SLC-on Landsat scene that provide same resolution, few changes, and similar data acquisition. But receiving of Landsat imagery is not stable in Korea. So SPOT image can be another alternative solution because it is a steady-state multispectral satellite image as Landsat image. In this study, we filled the SLC-off gap s of 2, 3, 4 bands using SPOT image by a local regression technique, and assigned the optimum spectral value to gaps of 1, 5, 7 bands based on a spectral adjacency. Through this process, we could restore Landsat SLC-off image and evaluated the accuracy of the results.

  • PDF

Occlusion and articulation in digital dentistry: A review (디지털 치의학 시대의 교합)

  • Lee, Jae-Hyun
    • The Journal of the Korean dental association
    • /
    • v.58 no.8
    • /
    • pp.505-512
    • /
    • 2020
  • With the fourth industrial revolution, digitization is accelerating in all healthcare areas. In the field of dentistry, active discussions on digital dental technologies are ongoing, with increasing interest from clinicians daily. Thus far, accuracy and efficiency have primarily been emphasized in digital dentistry, and interest in occlusion has been relatively low. This is because digital dentistry has been predominantly used to restore small numbers of teeth rather than extensive prosthetic reconstruction. However, in the future, most dental treatments will undergo a digital transformation that will require the application of digital technology to more extensive prosthetic rehabilitation, for which discussion of occlusion is essential. In extensive prosthetic reconstruction, occlusion and articulation involve determining the position of the dental arch in relation to the reference plane of the skull or the long axis of the face and the position of the transverse horizontal axis. It also includes determining an occlusal surface with a shape that allows the mandible to move in an eccentric path and masticate most efficiently without any occlusal interference. To better understand how digitization will impact dentistry, this review article summarizes and discusses occlusion and articulation using digital dental technologies. This discussion is divided into several aspects, including facial scan, virtual articulation, augmented reality, and virtual reality.