• 제목/요약/키워드: reference scan

검색결과 184건 처리시간 0.023초

악골 병소의 감별 진단시 골스캔의 임상적 유용성 (CLINICAL EFFECTIVENESS OF BONE SCAN FOR DIFFERENTIAL DIAGNOSIS OF JAW LESION)

  • 김정모;김철환
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권1호
    • /
    • pp.33-41
    • /
    • 2007
  • Bone scan using radioactive isotope can be more effective than conventional X-ray radiograph for finding jaw lesion because it takes an image of the physiologic change of bone. This study is designed to show how available bone scan is able to diagnose jaw lesion better than simple X-ray and CT, as well as to determine a basis of diagnosis for jaw lesion using bone scan. The 77 patients, visiting the Oral & Maxillofacial Surgery, Department of Dankook University Hospital from January 2002. to August 2005. who were diagnosed histopathologically with postoperative malignant tumor, osteomyelitis, and bone infiltrative benign disease. Preoperative X-ray, CT, bone scan were taken and were compared with histopathologic finding. Also to compare specificty of each lesion in bone scan, bone density was measured to compare. The results were as follows. 1. Among the 25 cases of oral malignant tumor of bony invasion, a positive diagnosis associated with histopathologic evaluation, 22 cases(88%) in bone scan, 14 cases(56%) in CT image, and 10 cases40%) in simple X-ray. 2. Among the 31 cases of osteomyelitis, a positive diagnosis associated with histopathologic evaluation, 30 cases(97%) in bone scan, 23 cases(74%) in CT image, and 19 cases(61%) in simple X-ray. 3. Among the 11cases of bone infiltrative benign disease, a positive diagnosis associated with histopathologic evaluation, 11 cases(100%) in bone scan, 10 cases(91%) in CT image, and 6 cases(55%) in simple X-ray. 4. Measurement of bone density in each group showed no statistical significant difference between malignant tumor and osteomyelitis as well as benign bone disease. But, a statistical significance was seen between osteomyelitis and benign bone disease. From this results, bone scan are more sensitive than simple X-ray and CT image in jaw lesion diagnosis, but specificity shows no significant difference. Therefore, it should be suggested that evaluation of bone scan must be carrying out in reference to final histopathologic diagnosis.

영상 복잡도와 다양한 매칭 스캔을 이용한 고속 전영역 움직임 예측 알고리즘 (A Fast Full-Search Motion Estimation Algorithm using Adaptive Matching Scans based on Image Complexity)

  • 김종남
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제32권10호
    • /
    • pp.949-955
    • /
    • 2005
  • 본 논문에서는 기존의 전영역 탐색 방식의 계산량을 현저히 줄임과 동시에 동일한 예측 화질을 얻기 위해, 기준 블록의 복잡도 순서와 정방형 서브블럭을 가지고 복잡한 영역 세분화를 통한 고속 블록 매칭(block matching) 알고리즘을 제안하였다. 매칭 에러가 기준 블록 기울기 크기에 비례한다는 것을 이용하여 종래의 순차적인 매칭 스캔(matching scan) 과 행/열 기반의 적응 매칭 스캔 대신, 복잡도에 기초한 정방형 서브 블록(sub-block) 적응 매칭 스캔을 가지고 불필요한 계산을 효율적으로 줄였다. 제안된 알고리즘은 예측 화질의 저하 없이 기존의 PDE(partial distortion elimination) 알고리즘을 이용한 전영역 탐색 방법에 비해 $30\%$의 계산량을 줄였으며, MPEG-2 및 MPEG-4 AVC를 이용하는 비디오 압축 응용분야에 유용하게 사용될 수 있을 것이다.

Full-arch accuracy of five intraoral scanners: In vivo analysis of trueness and precision

  • Kwon, Miran;Cho, Youngmok;Kim, Dong-Wook;Kim, MyungSu;Kim, Yoon-Ji;Chang, Minho
    • 대한치과교정학회지
    • /
    • 제51권2호
    • /
    • pp.95-104
    • /
    • 2021
  • Objective: To evaluate the trueness and precision of full-arch scans acquired using five intraoral scanners and investigate the factors associated with the dimensional accuracy of the intraoral scan data. Methods: Nine adult participants (mean age, 34.3 ± 8.3 years) were recruited. Four zirconium spheres (Ø 6 mm) were bonded to the canines and the molars. Following acquisition of reference scans using an industrial-grade scanner, five intraoral scanners, namely i500, CS3600, Trios 3, iTero, and CEREC Omnicam, were used to scan the arches. Linear distances between the four reference spheres were automatically calculated, and linear mixed model analysis was performed to compare the trueness and precision of the intraoral scan data among the different scanners. Results: The absolute mean trueness and precision values for all intraoral scanners were 76.6 ± 79.3 and 56.6 ± 52.4 ㎛, respectively. The type of scanner and the measured linear distances had significant effects on the accuracy of the intraoral scan data. With regard to trueness, errors in the intermolar dimension and the distance from the canine to the contralateral molar were greater with Omnicam than with the other scanners. With regard to precision, the error in the linear distance from the canine to the molar in the same quadrant was greater with Omnicam and CS3600 than with the other scanners. Conclusions: The dimensional accuracy of intraoral scan data may differ significantly according to the type of scanner, with the amount of error in terms of trueness being clinically significant.

3차원 인체형상 스캔데이터를 이용한 남자 바지패턴 설계 (Development of Men Slacks Pattern Using 3D Scan Data)

  • 손부현
    • 대한가정학회지
    • /
    • 제46권9호
    • /
    • pp.137-146
    • /
    • 2008
  • This study was conducted in order to spread out lower body 3D scan data of men in their twenties. The aim was to achieve slacks pattern with ease allowance through comparison with existing flat patterns. For conversion of 3D scan data into 20 pattern, reference lines were established by using Rapid Foam in 3D shape analysis software. 2C-AN program and Yuka CAD were used to convert 20 pattern earned with straight posture of 3D scan data into slacks pattern by using Triangle Simplification & Runge-Kutta Method. In order to achieve this we needed to set a line 9cm below the hip line, to array vertex of each block to crease line while maintaining the horizontal line. And then we needed to set ease allowance in back crotch and to set waist circumference or hip circumference ease allowance in side seam of slacks. Results showed that long front crotch length can be achieved if 3D scan data is compared with 20 existing flat pattern. Slacks pattern that raise front crotch by about 1.5cm compared to back crotch and also possess ease allowance in back crotch area are great in appearance evaluation.

전영역 탐색의 고속 움직임 예측에서 기울기 크기와 부 블록을 이용한 적응 매칭 스캔 알고리즘 (Adaptive Matching Scan Algorithm Based on Gradient Magnitude and Sub-blocks in Fast Motion Estimation of Full Search)

  • 김종남;최태선
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.1097-1100
    • /
    • 1999
  • Due to the significant computation of full search in motion estimation, extensive research in fast motion estimation algorithms has been carried out. However, most of the algorithms have the degradation in predicted images compared with the full search algorithm. To reduce an amount of significant computation while keeping the same prediction quality of the full search, we propose a fast block-matching algorithm based on gradient magnitude of reference block without any degradation of predicted image. By using Taylor series expansion, we show that the block matching errors between reference block and candidate block are proportional to the gradient magnitude of matching block. With the derived result, we propose fast full search algorithm with adaptively determined scan direction in the block matching. Experimentally, our proposed algorithm is very efficient in terms of computational speedup and has the smallest computation among all the conventional full search algorithms. Therefore, our algorithm is useful in VLSI implementation of video encoder requiring real-time application.

  • PDF

전자급수기에 관한 연구 (System Design of an Electronic Watering Device)

  • 박규태
    • 대한전자공학회논문지
    • /
    • 제10권5호
    • /
    • pp.1-6
    • /
    • 1973
  • 본논문은 자동급수기의 설계 및 제작연구를 한 것으로 digital scanning circuits를 이용하여 10개의 probe를 차례로 scanning하여 지표의 습도를 검출하여 reference level과 비교하여 필요한곳에 자동적으로 급수하도록 설계하였다. 이 system의 control을 위하여 main clock oscillator와 controloscillator를 사용하였고 control circuit로는 programmable unijunction transistor를 이용하여 reference level을 조절하게하여 임의의 원하는 습도에 급수하도록 하였다. 제작된 급수재는 모래의 습도가 6%에서 51%로 변화시키면서 실험하여 언제나 input level이 reference level보다 약 0.6V보다 높을때 완전동작하였으며 reference level은 임의로 조절할 수 있었다.

  • PDF

Displacement of scan body during screw tightening: A comparative in vitro study

  • Kim, JungHan;Son, KeunBaDa;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.307-315
    • /
    • 2020
  • PURPOSE. The purpose of this study was to evaluate the occurrence of displacement while tightening the screw of scan bodies, which were compared according to the material type. MATERIALS AND METHODS. Three types of scan bodies whose base regions were made up of polyether ether ketone (PEEK) material [Straumann Group, Dentium Group, and Myfit (PEEK) Group] and another scan body whose base region was made up of titanium material [Myfit (Metal) Group] were used (15 per group). The reference model was fabricated by aligning the scan body library on the central axis of the implant, and moving this position by the resin model. The screws of the scan bodies were tightened to the implant fixture with torques of 5 Ncm, 10 Ncm, and a hand tightening torque. After the application of the torque, the scan bodies were scanned using a laboratory scanner. To evaluate the vertical, horizontal, and 3-dimensional (3D) displacements, a 3D inspection software program was used. To examine the difference among groups, one-way analysis of variance and Tukey's HSD post hoc test were used (α=.05). RESULTS. There were significant differences in 3D, vertical, and horizontal displacements among the different types of scan bodies (P<.001). There was a significantly lower displacement in the Straumann group than in the Myfit (PEEK) and Dentium groups (P<.05). CONCLUSION. The horizontal displacement in all groups was less than 10 ㎛. With the hand tightening torque, a high vertical displacement of over 100 ㎛ occurred in PEEK scan bodies (Myfit and Dentium). Therefore, it is recommended to apply a tightening torque of 5 Ncm instead of a hand tightening torque.

두부 CT에서 차폐기법과 새로운 관전류변조기법에 따른 눈의 선량과 화질평가 (The Evaluation of Eye Dose and Image Quality According to The New Tube Current Modulation and Shielding Techniques in Brain CT)

  • 권순무;김정수
    • 한국방사선학회논문지
    • /
    • 제9권5호
    • /
    • pp.279-285
    • /
    • 2015
  • 두부 CT 검사에서 눈의 수정체는 높은 방사선 감수성으로 보호되어야 할 장기 중에 하나이다. 두부 CT 검사에서 눈의 피폭선량감소 목적으로 사용되는 비스무스 차폐체는 현저한 선량 감소 효과가 있지만 화질저하의 문제점이 있다. 본 연구는 인체팬텀을 이용한 두부 CT 검사에서 피폭 선량을 줄이기 위해 사용되는 관전류변조기법인 new organ based-tube current modulation, longitudinal-TCM, angular-TCM과 차폐기법인 비스무스, 납 안경을 사용하여 눈의 선량과 화질의 변화 정도를 평가하였다. 연구결과, new OB-TCM에서 눈의 선량은 25.88% 감소되었으며 비스무스를 사용한 검사와 비교하여 CT number, 노이즈, SNR의 변화가 작은 것을 확인하였다. 따라서 new OB-TCM을 임상의 두부 CT 검사에 적용할 경우, 눈의 피폭선량을 감소시키면서 영상의 화질 저하를 방지할 수 있을 것으로 기대된다.

소아 두부 전산화단층촬영 선량지표 분석을 통한 피폭선량 모니터링: 일개병원 사례 중심으로 (Analyzed the Computed Tomography Dose Index (CTDI) to the Pediatric Brain CT by Reason of the Observation for the Exposure Dose: Base on a Hospital)

  • 이재승;김현진;임인철
    • 한국콘텐츠학회논문지
    • /
    • 제15권6호
    • /
    • pp.290-296
    • /
    • 2015
  • 본 연구는 일개병원에서 시행된 년간 소아 두부 CT 검사에 대한 CT 선량지표(CTDI)를 국내 진단참고 준위와 비교하여 분석함으로써 제안점을 도출하고 피폭 방사선량 저감화 방안을 제시하고자 하였다. 이를 위하여 2014년 1월부터 12월까지 두부 손상으로 소아 두부 CT 검사를 의뢰 받은 10세 미만의 소아 231명을 후향적으로 조사하였다. 조사 방법은 선량 보고서와 의료전자차트를 참조하여 일반적 특성, 관전압(kVp), 관전류(mA), 검사 범위, $CTDI_{vol}$, DLP를 조사하여 분석하였다. 결과적으로 $CTDI_{vol}$은 전체 연구대상자의 7.4%(17명)가 국내 진단참고준위를 초과한 것으로 나타났으며 DLP의 경우 41.6%(96명)가 초과 되어 $CTDI_{vol}$ 보다 비교적 높게 나타났다. DLP는 한국식품의약품안전처에서 제시한 CT 선량 지표보다 대부분 약 60% 이상 초과되었으며 건강보험심사평가원에서 제시한 기준 검사 범위보다 약 30%이상 증가된 검사 범위가 DLP가 높게 나타난 원인으로 분석되었다. 결론적으로 임상에서 CT 검사 시 건강보험심사 평가원에서 제시하는 소아 두부 CT 검사의 기준 검사 범위를 준수하여 검사하고 프로토콜을 적절히 조절한다면 피폭선량을 상당히 낮출 수 있을 것으로 판단된다.

다층 후판 복합재 패널의 결함 검출을 위한 C-Scan 이미지 보정기법 (Enhancement of Ultrasonic C-scan Images for Inspection of Multi-layered Composite Panels)

  • 조현;송성진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제26회 춘계학술대회논문집
    • /
    • pp.264-267
    • /
    • 2006
  • 초음파를 이용한 다층 후판 복합재 패널의 비파괴 검사에서 상층부의 신호간섭효과는 결함판정을 보다 어렵게 만드는 중대한 요인으로 작용한다. 이러한 문제를 해결하기 위해, 본 연구에서 초음파 C-Scan 이미지에 영향을 미치는 복합재 상층 패널의 신호간섭을 제거할 수 있는 이미지 향상기법을 제안하였다. 이는 수집된 초음파 수신신호를 보정신호를 이용해 정규화하고 그 결과 신호를 C-Scan 이미지로 재구성하는 기법으로 본 논문에서는 이미지 향상기법의 제안과 그 실험적 성능검증에 대하여 논하였다. 복합재 상층 패널의 계면효과를 제거하기 위해 인공결함을 내재시킨 세 개의 결함시험편을 제작하고, 이들 시험편에서 C-Scan 이미지를 실험적으로 획득하였다. 그리고, 개발된 이미지 보정기법을 적용하였는데, 제안된 기법이 이미지 개선알고리즘으로 실용적 적용성이 충분함을 입증하는 결과를 얻었다.

  • PDF