• Title/Summary/Keyword: reference sample

Search Result 864, Processing Time 0.024 seconds

Comparative Transcriptome Analysis of Queen, Worker, and Larva of Asian Honeybee, Apis cerana

  • Kim, Woo Jin;Lee, Seok Hee;An, Saes Byeol;Kim, Song Eun;Liu, Qin;Choi, Jae Young;Je, Yeon Ho
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.27 no.2
    • /
    • pp.271-276
    • /
    • 2013
  • The Asian honeybee, Apis cerana, is a native honeybee species in Korea which is important in agriculture for pollination and honey production. For better understanding of the physiology of A. cerana, high-throughput Illumina transcriptome sequencing was performed to analyze the gene expression profiles of queen, worker, and larva. A total of 219,799,682 clean reads corresponding to 22.2 Gb of nucleotide sequences was obtained from the whole body total RNA samples. The Apis mellifera reference mRNA sequence database was used to measure the gene expression level with Bowtie2 and eXpress software, and the Illumina short reads were then mapped to 11,459 out of 11,736 A. mellifera reference genes. Total of 9,221 genes with FPKM value greater than 5 of each sample group were subjected to eggNOG with BLASTX for gene ontology analysis. The differential gene expression between queen and worker, and worker and larva were analyzed to screen the overexpressed genes in each sample group. In the queen and worker sample group, total of 1,766 genes were differentially expressed with 887 and 879 genes overexpressed over two folds in queen and worker, respectively. In the worker and larva sample group, total of 1,410 genes were differentially expressed with 1,009 and 401 genes overexpressed over two folds in worker and larva, respectively.

A PLL with an unipolar charge pump and a loop filter consisting of sample-hold capacitor and 2nd-order RC filter (2차-RC 필터와 Sample-Hold 커패시터로 구성된 루프 필터와 단방향 전하펌프를 가진 PLL)

  • Baek, Seung-Ha;Choi, Young-Shig
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.10
    • /
    • pp.2380-2386
    • /
    • 2013
  • A PLL with an unipolar charge pump and a loop filter consisting of sample-hold capacitor and 2nd-order RC filter has been proposed. The goal of the proposed PLL is the suppression of reference spur which is caused by charge pump mismatch. It also improves phase noise characteristic. It has been designed with a 1.8V $0.18{\mu}m$ CMOS process and proved by HSPICE simulation.

Uncertainty in Determination of Menthol from Mentholated Cigarette (담배 중 멘톨 분석에 대한 불확도 측정)

  • 장기철;이운철;백순옥;한상빈
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.22 no.1
    • /
    • pp.91-98
    • /
    • 2000
  • This study was carried out to evaluate the uncertainty in the analysis of menthol content from the mentholated cigarette. Menthol in the sample cigarette was extracted with methanol containing an anethole as an internal standard, and then analyzed by gas chromatography. As the sources of uncertainty associated with the analysis of menthol, were the following points tested, such as the weighing of sample, the preparation of extracting solution, the pipetting of extracting solution into the sample, the preparation of standard solution, the precision of GC injections for standard & sample solution, the GC response factor of standard solution, the reproducibility of menthol analysis, and the determination of water content in tobacco, etc. For calculating the uncertainties, type A of uncertainty was evaluated by the statistical analysis of a series of observation, and type B by the information based on supplier's catalogue and/or certificated of calibration. Sources of uncertainty were subsequently included and mathematically combined with the uncertainty arising from the assessment of accuracy to provide the overall uncertainty. It was shown that the main source of uncertainty came from the errors in the reproducibility of menthol and water determination, the purity of menthol reference material in the preparation of standard solution, and the precision of GC injections for sample solution. The errors in sample weighing and volume measurement contributed relatively little to the overall uncertainty. The expanded uncertainty in the mentholated cigarettes, Korean and American brand, at 0.95 level of statistical confidence was $\pm$0.06 and $\pm$0.07 mg/g for a menthol content of 1.89 and 2.32 mg/g, respectively.

  • PDF

Influence of GaAs/AlGaAs Superlattice Layers on Optical Properties of InAs Quantum Dots (InAs 양자점의 광학적 성질에 미치는 초격자층의 영향)

  • Jeong Yonkil;Choi Hyonkwang;Park Yumi;Hwang Sukhyon;Yoon Jin-Joo;Lee Jewon;Leem Jae-Young;Jeon Minhyon
    • Korean Journal of Materials Research
    • /
    • v.14 no.2
    • /
    • pp.146-151
    • /
    • 2004
  • We investigated the effects of high potential barriers on the optical characteristics of InAs quantum dots (QDs) by using photoluminescence (PL) and photoreflectance (PR) spectroscopy. A sample with regular InAs quantum dots on GaAs was grown by molecular beam epitaxy (MBE) as a reference. Another InAs QDs sample was embedded in single AlGaAs barriers. On the other hand, a sample with GaAs/AlGaAs superlattice barriers was adopted for comparison with a sample with a single AlGaAs layer. In results, we found that the emission wavelength of QDs was effectively tailored by using high potential barriers. Also, it was found that the optical properties of a sample with QDs embedded in GaAs/AlGaAs superlattices were better than those of a sample with QDs embedded in a single layer of AlGaAs barriers. We believe that GaAs/AlGaAs superlattice could effectively prevent the generation of defects.

Aging Analysis of Catenary Wires in Accordance with Temperature Changes for a Long Period of Time (장기간 온도변화에 따른 전차선로 전선류의 노후도 분석)

  • Cho, Nam-Hee;Oh, Wan-Shik;Kim, Jae-moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1590-1596
    • /
    • 2016
  • In this paper, catenary wires were analyzed aging through the experiment about a new product and a test sample in accordance with temperature changes from long-term use. In case of the contact wire, the maximum load was reduced within 7% and the tensile strength showed a reduced within 6.7% compared with a new reference standard $110mm^2$. 19 Strands of messenger wire have a little more than a standard value, but result data on tensile test were less than the reference value about stranded wire. Also parts among 49 strands of dropper was found to be smaller than the reference value and it appeared greatly increasing intensity as toward the center of the strand.

Precision of Digital Photogrammetry for the Roughness Measurement of Rock Surfaces

  • Lee, Hyo-Sung;Ahn, Ki-Won;Park, Byung-Uk;Kim, Yong-Il
    • Korean Journal of Geomatics
    • /
    • v.3 no.1
    • /
    • pp.43-51
    • /
    • 2003
  • This paper presents the benefits of using close-range digital photogrammetric techniques for measuring the roughness of rock surfaces, using digital stereo images obtained from a Rolleiflex 6006 metric camera. To precisely measure surface roughness, we researched on how to use the flat and curved reference surface obtained from geometrically corrected digital images of the rock surface by using the least squares method. To test the precision of the proposed technique, the surface roughness has been measured between the reference surface and sample areas of very smooth-surfaced rock. Then the results were compared with the measurements obtained from a laser sensor profilometer.

  • PDF

The Effect of Ethnic Identification and Social Group Affiliation on Body Image Satisfaction among Asian-American College Students

  • Lee, Yoon-Jung
    • International Journal of Human Ecology
    • /
    • v.8 no.1
    • /
    • pp.9-18
    • /
    • 2007
  • This study focuses on the relationship between ethnic identity of Asian-Americans and their appreciation of their ethnic body features, based on reference group theory. A convenience sample of 60 male and 52 female students from various Asian ethnicities attending a mid-western university was used for the study. A 2 (gender) by 2 (ethnic identification) by 2 (socializing group) analysis of covariance (ANCOVA) on body image satisfaction as dependent variable and Body Mass Index score as a covariate was conducted. A significant main effect of ethnic identification was found, which indicates the more respondents identified with their ethnic group, the more likely they were to be satisfied with their appearance. The social group affiliation main effect was not significant. The impact of ethnic identification was significant only for those respondents who socialize more with Americans than with Asians. The results support the idea that one's ethnic group functions as a reference group, which influences body image appraisals.

Noninformative Priors for Fieller-Creasy Problem using Unbalanced Data

  • Kim, Dal-Ho;Lee, Woo-Dong;Kang, Sang-Gil
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.71-84
    • /
    • 2005
  • The Fieller-Creasy problem involves statistical inference about the ratio of two independent normal means. It is difficult problem from either a frequentist or a likelihood perspective. As an alternatives, a Bayesian analysis with noninformative priors may provide a solution to this problem. In this paper, we extend the results of Yin and Ghosh (2001) to unbalanced sample case. We find various noninformative priors such as first and second order matching priors, reference and Jeffreys' priors. The posterior propriety under the proposed noninformative priors will be given. Using real data, we provide illustrative examples. Through simulation study, we compute the frequentist coverage probabilities for probability matching and reference priors. Some simulation results will be given.

  • PDF

Bioequivalence Study of Loxoprofen Sodium in healthy Volunteers (Loxoprofen sodium 제제(레녹스정)의 생물학적 동등성시험)

  • 최주영;유내춘;박민수;김경환
    • Biomolecules & Therapeutics
    • /
    • v.6 no.4
    • /
    • pp.417-422
    • /
    • 1998
  • Loxoprofen sodium (sodium 2-[4-(2-oxocyclopentylmethyl)phenyl] propionate dehydrate) is a nonsteroidal antiinflammatory drug of $\alpha$-phenyl propionic acid derivative. To test the bioequivalence of loxoprofen, the pharmacokinetic parameters of new preparation of loxoprofen, LENOX was compared with LOXONIN as a reference drug. Fourteen healthy volunteers were entered to the stydy (Yonsei University College of Medicine, Severance Hospital IRB approval No. 9608). They were administered 60 mg of loxoprofen in 2$\times$2 cross-over design. There was one week of drug-free interval between doses. The blood sample was taken on schedule up to 8 hours, and the plasma concentration loxoprofen was measured by reverse phase high-performance liquid chromatography (HPLC) with UV-detector. There were no significant difference between two preparations when AUC, Cmax, and Tmax were compared by ANOVA. The mean differences of AUC, Cmax, and Tmax were within 20% of the reference drug: the values were 2.22,5.61, and 12.50%, respectively. The confidence limits of AUC and Cmax but not Tmax satisfied the bioequivalence criteria. These results suggest that the tested LENOX is bioequivalent to the reference drug.

  • PDF

Reference Feature Based Cell Decomposition and Form Feature Recognition (기준 특징형상에 기반한 셀 분해 및 특징형상 인식에 관한 연구)

  • Kim, Jae-Hyun;Park, Jung-Whan
    • Korean Journal of Computational Design and Engineering
    • /
    • v.12 no.4
    • /
    • pp.245-254
    • /
    • 2007
  • This research proposed feature extraction algorithms as an input of STEP Ap214 data, and feature parameterization process to simplify further design change and maintenance. The procedure starts with suppression of blend faces of an input solid model to generate its simplified model, where both constant and variable-radius blends are considered. Most existing cell decomposition algorithms utilize concave edges, and they usually require complex procedures and computing time in recomposing the cells. The proposed algorithm using reference features, however, was found to be more efficient through testing with a few sample cases. In addition, the algorithm is able to recognize depression features, which is another strong point compared to the existing cell decomposition approaches. The proposed algorithm was implemented on a commercial CAD system and tested with selected industrial product models, along with parameterization of recognized features for further design change.