• Title/Summary/Keyword: reference range

Search Result 1,777, Processing Time 0.022 seconds

Acute Variation of Hematological Parameters during 622 km Ultra-Marathon

  • Shin, Kyung-A;Kim, Young-Joo
    • Biomedical Science Letters
    • /
    • v.23 no.3
    • /
    • pp.208-214
    • /
    • 2017
  • To investigate the effects of strenuous physical exercise on commonly used hematological markers in subjects the intensive long running. Blood samples were obtained from nineteen participants in a 622 km ultra-marathon race before, 300 km and immediately after completion of the 622 km ultra-marathon. Samples were analyzed for total white cell count (WBC) and differential, total red cell count (RBC), hemoglobin, hematocrit, mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), red cell distribution width (RDW), platelets, mean platelets volume (MPV), platelets distribution width (PDW). Significant increases were found in WBC, neutrophil and platelets at 622 km compared to the pre-race. RBC, hemoglobin and hematocrit decreased statistically significantly the race at 300 km and 622 km compared to pre-race. A wide range of hematological perturbations occur during 622 km ultra-marathon running but it was physiological changes within a reference range. The 622 km ultra-marathon is less likely to cause clinically significant hematologic changes in athletes.

Reliability Estimation Using Kriging Metamodel (크리깅 메타모델을 이용한 신뢰도 계산)

  • Cho Tae-Min;Ju Byeong-Hyeon;Jung Do-Hyun;Lee Byung-Chai
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.8 s.251
    • /
    • pp.941-948
    • /
    • 2006
  • In this study, the new method for reliability estimation is proposed using kriging metamodel. Kriging metamodel can be determined by appropriate sampling range and sampling numbers because there are no random errors in the Design and Analysis of Computer Experiments(DACE) model. The first kriging metamodel is made based on widely ranged sampling points. The Advanced First Order Reliability Method(AFORM) is applied to the first kriging metamodel to estimate the reliability approximately. Then, the second kriging metamodel is constructed using additional sampling points with updated sampling range. The Monte-Carlo Simulation(MCS) is applied to the second kriging metamodel to evaluate the reliability. The proposed method is applied to numerical examples and the results are almost equal to the reference reliability.

Sensorless control of PMSM in low speed range using high frequency voltage injection (전압주입 방식을 이용한 PMSM 센서리스 제어에 관한 연구)

  • Yoon Seok-chae;Kim Jang-mok
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.119-122
    • /
    • 2003
  • This paper describes the sensorless technique for the surface-mounted permanent-magent synchronous motor(SPMSM or PMSM) drive based on magnetic saliency. The control technique is a sensorless control algorithm that injects the high frequency voltage to the stator terminal in order to estimate the rotor position and speed. The rotor position and speed for sensorless vector control is achieved by appropriate signal processing to extract the position information from the stator current in the low speed range including zero speed. Proposed sensorless algorithm using the double-band hysteresis controller and initial rotor position detection exhibits excellent reference tracking and increased robustness. Experimental results are presented to verify the feasibility of the proposed control schemes.

  • PDF

Performance Testing of Integrated Strapdwon INS and GPS

  • Lee, Sang-Joog;Yoo, Chang-Sun;Shim, Yo-Han;Kim, Jong-Chul
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.2 no.1
    • /
    • pp.67-77
    • /
    • 2001
  • In recent navigation system, the profitable solution is to integrate the GPS and Stapdwon INS (SDINS) system and its integration allows compensation for shortcomings of each system. This paper describes the hardware preparation and presents the test results obtained from the automobile test of the developed system. The automobile tests was conducted with two kinds of inertial sensors and GPS receivers : short range and middle range test, to verify and evaluate the performance of the integrated navigation system. The reference of position is given by the Differential GPS(DGPS) which has cm-level accuracy to compare the accuracy of system. Kalman filtering is used for integrating GPS and SDINS and this filter effectively allows the long-term stability of GPS to correct and decrease the time deviation error of SDINS.

  • PDF

Practical Ultraprecision Positioning of a Ball Screw Mechanism

  • Sato, Kaiji;Maeda, Guilherme Jorge
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.44-49
    • /
    • 2008
  • This paper describes the problem of ultraprecision positioning with a ball screw mechanism in the microdynamic range, along with its solution. We compared the characteristics of two ball screw mechanisms with different table masses. The experimental results showed that the vibration resulting from the low stiffness of the ball screw degraded the positioning performance in the microdynamic range for the heavyweight mechanism. The proposed nominal characteristic trajectory following (NCTF) controller was designed for ultra precision positioning of the ball screw mechanism. The basic NCTF control system achieved ultra precision positioning performance with the lightweight mechanism, but not with the heavyweight mechanism. A conditional notch filter was added to the NCTF controller to overcome this problem. Despite the differences in payload and friction, both mechanisms then showed similar positioning performance, demonstrating the high robustness and effectiveness of the improved NCTF controller with the conditional notch filter. The experimental results demonstrated that the improved NCTF control system with the conditional notch filter achieved ultra precision positioning with a positioning accuracy of better than 10 nm, independent of the reference step input height.

A New RF Range Measurement Algorithm Using the Code Comparison (코드비교에 의한 새로운 전파형 거리측정 알고리즘)

  • Kang, Byoung-Moo;Kim, Ung-Sik;Kim, Wan-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.462-464
    • /
    • 1997
  • In this paper we propose a new RF range measurement method. Using two codes which have different chip rate, we transmit one code toward the direction of targets and calculate the distance by comparing it with the other untransmitted reference code. Because the measuring process is fully digitalized, the stability, resolution, flexibility, and compactness of the system are good. Some experimental results are provided to show the validity and the performance of the proposed method.

  • PDF

Complex Conjugate Resolved Retinal Imaging by One-micrometer Spectral Domain Optical Coherence Tomography Using an Electro-optical Phase Modulator

  • Fabritius, Tapio E.J.;Makita, Shuichi;Yamanari, Masahiro;Myllyla, Risto A.;Yasuno, Yoshiaki
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.111-117
    • /
    • 2011
  • Full-range spectral domain optical coherence tomography (SD-OCT) with a 1-${\mu}m$ band light source is shown here. The phase of the reference beam is continuously stepped while the probing beam scans the sample laterally (B-scan). The two dimensional spectral interferogram obtained is processed by a Fourier transform method to obtain a complex spectrum leading to a full-range OCT image. A detailed mathematical explanation of the complex conjugate resolving method utilized is provided. The system's measurement speed was 7.96 kHz, the measured axial resolution was $9.6{\mu}m$ in air and the maximum sensitivity 99.4 dB. To demonstrate the effect of mirror image elimination, In vivo human eye pathology was measured.

CARS에서 배경신호의 제거에 의한 분광선회복

  • 이은성
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.457-463
    • /
    • 1993
  • We investigated that the CARS signals generated from resonant or nonresonant contributions can be selectively suppressed by phase-controlled nonlinear interferometry. To control the phase of the CARS signal over a broad spectral range, a home-made phase shifting unit was used, whose thickness was automatically controlled as the wavelength of Stokes beam scaned. Using this technique, we recovered the Q-branch resonance lines of carbon monoxide and HC1 which had been distorted and buried by the nonresonant and resonant signal of propane respectively. All the spectrum measured have been normalized by reference signal which had no resonance lines over the spectral range of interest.

  • PDF

Wide Speed Direct Torque and Flux Controlled IPM Synchronous Motor Drive Using a Combined Adaptive Sliding Mode Observer and HF Signal Injection

  • Foo, Gilbert;Rahman, M.F.
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.582-592
    • /
    • 2009
  • This paper proposes a new speed sensorless direct torque and flux controlled interior permanent magnet synchronous motor (IPMSM) drive. Closed-loop control of both the torque and stator flux linkage are achieved by using two proportional-integral (PI) controllers. The reference voltage vectors are generated by a SVM unit. The drive uses an adaptive sliding mode observer for joint stator flux and rotor speed estimation. Global asymptotic stability of the observer is achieved via Lyapunov analysis. At low speeds, the observer is combined with the high frequency signal injection technique for stable operation down to standstill. Hence, the sensorless drive is capable of exhibiting high dynamic and steady-state performances over a wide speed range. The operating range of the direct torque and flux controlled (DTFC) drive is extended into the high speed region by incorporating field weakening. Experimental results confirm the effectiveness of the proposed method.

Voltage Control Strategy for Maximum Torque Operation of Field Oriented Induction Machine in the Field Weakening Region (전압 궤환 제어를 위한 약계자 영역에서의 벡터 제어 유도전동기의 최대 토오크 운전)

  • 김상훈;설승기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1084-1092
    • /
    • 1994
  • An induction machine can be operated in the constant power region over an extended high speed range by means of field weakening. A conventional field weakening method is to set the flux reference inversely proportional to the rotor speed. With this method, however, the machines can't yield the maximum torque over the entire high speed range. In this paper, a new field weakening method for the field oriented induction machine drive by the voltage control strategy is presented. The proposed scheme ensures not only producting the maximum torque over the entire field weakening region but also the robust control independent on machine parameters. Also the smooth transition into the field weakening operation and fast dynamic response during transient operation can be obtained. Simulation and experimental results from a 3hp laboratory induction motor drive system are done to confirm the proposed control algorithm.