• Title/Summary/Keyword: reference range

Search Result 1,775, Processing Time 0.036 seconds

A study of sagittal condylar inclination and occlusal plane inclination of two semiadjustablearticulators with different reference plane (기준면이 다른 반조절성 교합기의 전방시상과로각과 교합평면경사각에 대한 연구)

  • Kim, Hyo-Jung;Lee, Sung-Bok;Choi, Dae-Gyun;Bak, Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.420-430
    • /
    • 2008
  • Statement of problem & Purpose: Articulators are very important for education and overall clinical situation in the field of prosthodontics, however preexisting articulators are designed and built based on maxillofacial structures and mean values of mandibular movement of Western people. Purpose of this research is to find out a adequate basis for applicating these articulators, presently used for clinical education, for Korean. Material and methods: 59 Korean adults (41 males, 18 females), aged between 24 to 41, where selected for this study. Two pairs of both maxillary and mandibular models were made for each examinee. These models where attached to both KaVo PROTARevo 7 and Hanau Modular semiadjustable articulators by using facebow transfer, than sagittal condylar inclination, occlusal plane inclination and position of mandibular on the articulator where measured. Result and conclusion: 1. Mean sagittal condylar inclination for KaVo PROTAR semiadjustable articulator was $33.75^{\circ}$(standard deviation $12.46^{\circ}$) meanwhile Hanau Modular semiadjustable articulator showed $40.72^{\circ}$(standard deviation $12.09^{\circ}$) for mean sagittal condylar inclination. 2. Mean occlusal plane inclination for KaVo PROTAR semiadjustable articulator was $-2.76{\circ}$(standard deviation $3.63^{\circ}$) meanwhile Hanau Modular semiadjustable articulator showed $11.87^{\circ}$ (standard deviation $3.63^{\circ}$) for mean occlusal plane inclination. 3. On the average center of the mandibular dentition were in the range of 5 to 7 mm of the central position of the articulator. Both anterior and posterior dentition were positioned at the center of the articulator vernacularly for KaVo PROTAR semiadjustable articulators, meantime for Hanau Modular semiadjustable articulator, anterior dentition was positioned 5 mm downwards and 3mm upwards for posterior dentition from vertically central position of the articulator.

The Cutoff Value of HbA1c in Predicting Diabetes and Impaired Fasting Glucose (당뇨병 및 공복혈당장애 예측을 위한 당화혈색소 값)

  • Kwon, Seyoung;Na, Youngak
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.2
    • /
    • pp.114-120
    • /
    • 2017
  • There have been many studies to develop methods for predicting diabetes and to prevent diabetes. The validity of glycated hemoglobin (HbA1c), one of the commonly known tools in predicting diabetes, has been verified by many previous studies. In this study, we examined the cutoff value of HbA1c for diabetes and impaired fasting glucose (IFG). Based on this study, we proposed a proper clinical guideline and evaluated the validation of the guideline. Excluding those without blood glucose and HbA1c data, we used the data of 5,161 subjects (2,281 men and 2,880 women) over the age of 20 years from the 2015 Korean National Health and Nutrition Examination Survey. The correlation efficient of fasting plasma glucose (FPG) and HbA1c was 0.79, indicating a strong relationship. Howeve, the correlation efficient of FPG and HbA1c was low, showing 0.27 in non-diabetes, 0.39 in IFG, and 0.66 in diabetes, showing a strong relationship. The cutoff value of HbA1c for predicting diabetes using ROC curve was 6.05% (sensitivity 84.6%, and specificity 92.0%), and AUC was 0.941 (0.937 in men, and 0.946 in women). The cutoff value of HbA1c for predicting IFG using ROC curve was 5.55% (sensitivity 64.5%, and specificity 70.0%), and AUC was 0.733 (0.708 in men, and 0.764 in women). Therefore, it may not be appropriate to apply the guidelines for diagnosing IFG since sensitivity and specificity were below 70%. For future studies retarding the cutoff value of HbA1c in predicting IFG, high sensitivity and specificity are expected if we segment the reference range of IFG.

Predicting Potential Habitat for Hanabusaya Asiatica in the North and South Korean Border Region Using MaxEnt (MaxEnt 모형 분석을 통한 남북한 접경지역의 금강초롱꽃 자생가능지 예측)

  • Sung, Chan Yong;Shin, Hyun-Tak;Choi, Song-Hyun;Song, Hong-Seon
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.5
    • /
    • pp.469-477
    • /
    • 2018
  • Hanabusaya asiatica is an endemic species whose distribution is limited in the mid-eastern part of the Korean peninsula. Due to its narrow range and small population, it is necessary to protect its habitats by identifying it as Key Biodiversity Areas (KBAs) adopted by the International Union for Conservation of Nature (IUCN). In this paper, we estimated potential natural habitats for H. asiatica using maximum entropy model (MaxEnt) and identified candidate sites for KBA based on the model results. MaxEnt is a machine learning algorithm that can predict habitats for species of interest unbiasedly with presence-only data. This property is particularly useful for the study area where data collection via a field survey is unavailable. We trained MaxEnt using 38 locations of H. asiatica and 11 environmental variables that measured climate, topography, and vegetation status of the study area which encompassed all locations of the border region between South and North Korea. Results showed that the potential habitats where the occurrence probabilities of H. asiatica exceeded 0.5 were $778km^2$, and the KBA candidate area identified by taking into account existing protected areas was $1,321km^2$. Of 11 environmental variables, elevation, annual average precipitation, average precipitation in growing seasons, and the average temperature in the coldest month had impacts on habitat selection, indicating that H. asiatica prefers cool regions at a relatively high elevation. These results can be used not only for identifying KBAs but also for the reference to a protection plan for H. asiatica in preparation of Korean reunification and climate change.

Establishment of analytical methods for HPHC list of mainstream cigarette smoke (담배 주류연 중 7개 그룹의 유해성분(HPHC) 분석법 확립 및 유효성 평가)

  • Park, Hyoung-Joon;Lee, Jin-Hee;Cho, So-Hyun;Heo, Seok;Yoon, Chang-yong;Baek, Sun-Young
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.385-397
    • /
    • 2015
  • Harmful and potentially harmful constituents (HPHCs) are chemical compounds in tobacco smoke that cause harm to smokers and non-smokers. This study established and validated methods for the analysis of HPHCs from mainstream cigarette smoke. The analyzed HPHCs were categorized into seven groups: aromatic amines, volatile organic compounds (VOCs), heavy metals, tobacco specific nitrosamines (TSNAs), benzo[a]pyrene (B[a]P), ammonia, and carbonyl compounds. The methods were validated by specificity, linearity, limit of detection (LOD), accuracy, precision, and recovery. These validated methods were then applied to the reference cigarettes (1R5F, 3R4F). The correlation coefficients (r2) for the calibration curves of the seven groups were over 0.995. The LODs showed values of 0.01-0.04 ng/cig cig for aromatic amines, 0.01-0.16 μg/cig for VOCs, 0.01-1.27 ng/cig for heavy metals, 0.06-0.28 ng/cig for TSNAs, 0.04 ng/cig for benzo[a]pyrene, 0.08 μg/cig for ammonia, and 0.78-1.77 μg/cig for carbonyl compounds. The precisions obtained from the intra and inter-day batches were less than 15%. The accuracy and the recovery range were less than 15% and 79.2-117.5%, respectively. The proposed methods can therefore be applied for determining HPHCs in tobacco mainstream smoke.

Contrast-Enhanced Magnetic Resonance Angiography for Evaluation of the Steno-occlusive Disease of the Supraaortic Arteries: Comparison with Computed Tomography Angiography and Digital Subtraction Angiography (조영증강 자기공명 혈관조영술을 이용한 대동맥궁 위 혈관의 협착 및 페쇄 질환 평가: 전산화 단층 혈관조영술 및 디지털 감산혈관조영술과의 비교)

  • Jeh, Su-Kyung;Kim, Bum-Soo;Jung, So-Lyung;Ahn, Kook-Jin;Shin, Yong-Sam;Lee, Kwan-Sung;Kim, Young-In;Lee, Kwang-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.152-160
    • /
    • 2009
  • Purpose : To intra-individually compare diagnostic accuracy of high-resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with computed tomography angiography (CTA) and digital subtraction angiography (DSA) for the assessment of supraaortic steno-occlusive disease. Materials and Methods : Twenty-eight patients (20 men, 8 women, 53-79 years of age) underwent supraaortic CE-MRA, CTA and DSA. CE-MRA was performed on two 1.5T MR scanners (voxel dimension: $0.66{\times}0.66{\times}1.1$ or $1.2\;mm^3$), and CTA on 64-slice CT scanners (voxel dimension: $0.42{\times}0.42{\times}0.63\;mm^3$). All the three examinations were completed within 40 days (median 19 days; range 1-40 days). Retrospective evaluation and measurement of diameter of 6 extracranial and 9 intracranial arterial segments was done by 2 experienced radiologists. Results: A total of 420 arterial segments were examined by CE-MRA, CTA and DSA. On DSA, 34 stenoocclusive lesions were noted at extracranial (n= 19) and intracranial (n = 15) vessels. For extracranial stenosis greater than 70%, sensitivity, specificity, positive predictive value (PPV) and negative predictive values (NPV) were 94.7%, 98.7%, 90.0% and 99.3% on CE-MRA, and 94.7%, 99.3%, 94.7% and 99.3% on CTA. For intracranial stenosis greater than 50%, sensitivity; specificity, PPV and NPV were 93.3%, 98.3%, 77.8%and 99.6% on CE-MRA, and 86.7%, 97.9%, 72.2% and 99.1 % on CTA, with DSA as the standard of reference. Conclusion : Supraaortic CE-MRA is as reliable as CTA in depicting the arterial stenosis, and is effective in screening of significant stenosis of both extracranial and intracranial arterial stenosis.

  • PDF

Development of Work-related Musculoskeletal Disorder Questionnaire Using Receiver Operating Characteristic Analysis (Receiver Operating Characteristic 분석법을 이용한 업무관련성 근골격계질환 설문지 개발)

  • Kwon, Ho-Jang;Ju, Yeong-Su;Cho, Soo-Hun;Kang, Dae-Hee;Sung, Joo-Hon;Choi, Seong-Woo;Choi, Jae-Wook;Kim, Jae-Young;Kim, Don-Gyu;Kim, Jai-Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.3
    • /
    • pp.361-373
    • /
    • 1999
  • Objectives: Receive Operating Characteristic(ROC) curve with the area under the ROC curve(AUC) is one of the most popular indicator to evaluate the criterion validity of the measurement tool. This study was conducted to develop a standardized questionnaire to discriminate workers at high-risk of work-related musculoskeletal disorders using ROC analysis. Methods: The diagnostic results determined by rehabilitation medicine specialists in 370 persons(89 shipyard CAD workers, 113 telephone directory assistant operators, 79 women with occupation, and 89 housewives) were compared with participant's own replies to 'the questionnair on the worker's subjective physical symptoms'(Kwon, 1996). The AUC's from four models with different methods in item selection and weighting were compared with each other. These 4 models were applied to 225 persons, working in an assembly line of motor vehicle, for the purpose of AUC reliability test. Results: In a weighted model with 11 items, the AUC was 0.8155 in the primary study population, and 0.8026 in the secondary study population(p=0.3780). It was superior in the aspects of discriminability, reliability and convenience. A new questionnaire of musculoskeletal disorder could be constructed by this model. Conclusion: A more valid questionnaire with a small number of items and the quantitative weight scores useful for the relative comparisons are the main results of this study. While the absolute reference value applicable to the wide range of populations was not estimated, the basic intent of this study, developing a surveillance fool through quantitative validation of the measures, would serve for the systematic disease prevention activities.

  • PDF

Metabolic Responses of Activated Sludge to Pentachlorophenol in SBR Systems

  • ;Larry D. Benefield
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.273-284
    • /
    • 1994
  • The primary objective of this study was to examine the toxic effects of PCP on activated sludge and to analyze its metabolic responses while treating wastewater containing pentachlorophenol (PCP) in a sequencing batch reactor (SBR) system operating under different control strategies. This study was conducted in two phases 1 and 2 (8-hr and 12-hr cycles). Each phase was operated with two control strategies I and II. Strategy I (reactor 1) involved rapid addition (5 minutes to complete) of substrate to the reactor with continuous mixing but no aeration for 2 hours. Strategy ll (reactor 2) involved adding the feed continuously during the first 2 hours of the cycle when the system was mixed but not aerated. During both phases each reactor was operated at a sludge age of 15 days. The synthetic wastewater was used as a feed. The COD of the feed solution was about 380 mg/l. After the reference response for both reactors was established, the steady state response of each system was established for PCP feed concentrations of 0.1 mg/l, 1.0 mg/l, and 5.0 mg/l in SBR systems operating on both 8-hr and 12-hr cycles. Soluble COD removal was not inhibited at any feed PCP concentrations used. At 5.0 mg/l fined PCP concentration and in SBR systems operating on phase 2, the concentrations of MLVSS were decreased; selective pressure on the mixed biomass might be increased, narrowing the range of possible ecological responses; the settleability of activated sludge was poor; the SOURS were increased, showing that the systems were shocked. Nitrification was made to some extent at all concentrations of feed PCP in SBR systems operating on phase 2 whereas in SBR systems operating on phase 1 little nitrification was observed. Then, nitrification will be delayed as much as soluble COD removal is retarded due to PCP inhibition effects. Enhanced biological phosphorus removal occurring in the system operating with control strategy I during phase 1 of this work and in the presence of low concentrations of PCP was unreliable and might cease at anytime, whereas enhanced biological phosphorus removal occurring in the system operating with either control strategy I or II during phase 2 of this work and in the Presence of feed PCP concentrations up to 1.0 mg/l was reliable. When, however, such processes were exposed to 5.0 mg/l PCP dose, enhanced phosphorus removal ceased and never returned.

  • PDF

The Comparison of Quantitative Accuracy Between Energy Window-Based and CT-Based Scatter Correction Method in SPECT/CT Images (SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.93-101
    • /
    • 2015
  • Purpose In SPECT image, scatter count is the cause of quantitative count error and image quality degradation. Thus, a wide range of scatter correction(SC) methods have been studied and this study is to evaluate the accuracy of CT based SC(CTSC) used in SPECT/CT as the comparison with existing energy window based SC(EWSC). Materials and Methods SPECT/CT images were obtained after filling air in order to acquire a reference image without the influence of scatter count inside the Triple line insert phantom setting hot rod(74.0 MBq) in the middle and each SPECT/CT image was obtained each separately after filling water instead of air in order to derive the influence of scatter count under the same conditions. In both conditions, Astonish(iterative : 4 subset : 16) reconstruction method and CT attenuation correction were commonly applied and three types of SC methods such as non-scatter correction(NSC), EWSC, CTSC were used in images filled with image. For EWSC, 9 sub-energy windows were set additionally in addition to main(=peak) energy window(140 keV, 20%) and then, images were acquired at the same time and five types of EWSC including DPW(dual photo-peak window)10%, DEW(dual energy window)20%, TEW(triple energy window)10%, TEW5.0%, TEW2.5% were used. Under the condition without fluctuations in primary count, total count was measured by drawing volume of interest (VOI) in the images of the two conditions and then, the ratio of scatter count of total counts was calculated as percent scatter fraction(%SF) and the count error with image filled with water was evaluated with percent normalized mean-square error(%NMSE) based on the image filled with air. Results Based on the image filled with air, %SF of images filled with water to which each SC method was applied is NSC 37.44, DPW 27.41, DEW 21.84, TEW10% 19.60, TEW5% 17.02, TEW2.5% 14.68, CTSC 5.57 and the most scattering counts were removed in CTSC and %NMSE is NSC 35.80, DPW 14.28, DEW 7.81, TEW10% 5.94, TEW5% 4.21, TEW2.5% 2.96, CTSC 0.35 and the error in CTSC was found to be the lowest. Conclusion In SPECT/CT images, the application of each scatter correction method used in the experiment could improve the quantitative count error caused by the influence of scatter count. In particular, CTSC showed the lowest %NMSE(=0.35) compared to existing EWSC methods, enabling relatively accurate scatter correction.

  • PDF

Bioconcentration Factor(BCF) of Perchlorate from Agricultural Products and Soils (농산물과 토양에 대한 퍼클로레이트 함량 평가 및 생물농축계수 산출)

  • Kim, Ji-Young;Kim, Min-Ji;Lee, Jeong-Mi;Kim, Doo-Ho;Park, Ki-Moon;Kim, Won-Il
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.3
    • /
    • pp.224-230
    • /
    • 2013
  • BACKGROUND: Perchlorate(${ClO_4}^-$) is an anion that is extremely water-soluble and environmentally stable. It mostly exists in the form of sodium perchlorate, ammonium perchlorate and potassium perchlorate which are used in rocket fuels, propellants, ignitable sources, air bag inflation systems and explosives. Perchlorate can be taken into the thyroid glands and interfere with iodide uptake. The determination of perchlorate in agricultural products is important due to its potential health impact on humans. The objective of this study was to determine the perchlorate concentrations in the samples of various agricultural products and soils. METHODS AND RESULTS: In this study, samples of cereal(Rice, Barley, Corn, Bean), vegetable(Spinach, Lettuce, Sesame, Chives, Chili, Pumpkin, Tomato), fruit(Apple, Pear, Tangerine, Grape) were analyzed for perchlorate contents. Perchlorate concentrations were analyzed by liquid chromatography-tandem mass spectrometry. The results showed that agricultural products respectively contained perchlorate concentrations in the range of : cereals N.D.~$7.46{\mu}g/kg$, vegetables $0.52{\sim}23.06{\mu}g/kg$, fruits $0.19{\sim}2.66{\mu}g/kg$. Bioconcentration factor was in the order of : vegetables > cereals > fruits. Bioconcentration factor was highest follwed by Sesame 37.88, Corn 21.51, Spinach 10.57, Tangerine 4.39, Chives 2.89 and Lettuce 1.90. The recoveries of perchlorate from spiked agricultural products and soils ranged from 87.72~111.26% and 102.09~111.23%. CONCLUSION(S): The health risk assessment results obtained in this study are lower than the RfD(Reference Dose, 0.0007 mg/kg/body weight/day) value as suggested by the Integrated Risk Information System(US IRIS). Our results indicate that, people currently exposed to perchlorate from agricultural products consumption are considered as safe.

Quantifying Uncertainty of Vitamin C Determination in Infant Formula by Indophenol Titration Method (인도페놀 적정법에 의한 성장기용조제식 중 비타민 C 함량분석의 측정불확도 산정)

  • Jun, Jang-Young;Kwak, Byung-Man;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.352-359
    • /
    • 2005
  • Uncertainty involved during determination of vitamin C content in infant formula was quantified by indophenol titration method. Uncertainty sources in measurand, such as purity, weight, final volume of standard, volume of standard solution used for titration, sample weight, final volume of sample, extraction solution used for titration, titration of extraction solution and standard solution by indophenol solution were identified and used as parameters for combined standard uncertainty based on Guide to the expression of uncertainty in measurement (GUM) and Draft EURACHEM/CITAC Guide. Uncertainty parameters of each source in measurand were identified as resolution, reproducibility and stability of chemical balance, standard material purity, repeatability, reproducibility, end point of titration, 1 mL pipet, 5 mL autopipet, and 100 mL mass flask. Each uncertainty component was evaluated by types A and B and included to calculate combined uncertainty. Analytical test result for traceability under laboratorial conditions using Certified Reference Material (CRM) test was certified as $108.4{\pm}1.7mg/100g$, which was within CRM certification range of $114.6{\pm}6.6mg/100g$. Uncertainty test result of vitamin C content of 5 g sampling was $56.7{\pm}2.44mg/100g$. Uncertainty could be reduced by identification of uncertainty sources and components related with vitamin C determination by indophenol titration method and by decreasing uncertainty sources and components.