• 제목/요약/키워드: reference range

검색결과 1,775건 처리시간 0.031초

CDI시스템의 출력발생향상을 위한 실험적 연구 (Experimental Research to Improve the Output Characteristic of CDI System)

  • 전병실;김종규
    • 대한전기학회논문지
    • /
    • 제31권11호
    • /
    • pp.146-154
    • /
    • 1982
  • This paper proposes a new circuit for the CDI system to have a constant ignition power at the engine speed range of 500 to 7500 rpm and the battery voltage range of 12 to 16 volts in the 4-cylinder automobile. The proposed CDI system has a closed-loop with a PWM DC-DC converter controlled by the error signal between capacitor voltage and reference voltage. In order to decrease the capacitor charging time, the primary winding of ignition coil is made to be shorted during capacitor charging. An experimental suystem is fabricated and the results obtained thereof are found to be satisfactory.

휘도, 색차의 분포도 분석을 이용한 인지적 무기준법 영상 화질 평가방법 (A Novel Perceptual No-Reference Video-Quality Measurement With the Histogram Analysis of Luminance and Chrominance)

  • 김요한;성덕구;한정현;신지태
    • 방송공학회논문지
    • /
    • 제14권2호
    • /
    • pp.127-133
    • /
    • 2009
  • 영상통신기술의 발달로, 영상화질평가는 많은 연구자들에 의해 새로운 알고리즘이 연구되었고, 성능은 점차 개선되었다. 하지만, 사람의 주관적인 시각시스템은 너무나 다양하고, 복잡하기 때문에 이를 수식화하고, 객관화하는데 많은 어려움이 있다. 영상의 화질을 평가하는 방법은 전체 기준법 (Full-Reference), 감소기준법 (Reduced-Reference) 그리고 무기준법 (No-Reference)으로 나눌 수 있다. 이중 무기준법은 수신 영상외의 다른 정보가 필요 없기 때문에, 다양한 영상 스트리밍서비스에 사용될 수 있다. 본 연구에서는, 영상의 양자화로 인한 범위 왜곡을 고려한 새로운 무기준법 영상 화질 평가 방법을 제안한다. 그리고, 성능을 비교하기 위해서, ITU-T P910 문서에 따른 주관적 화질 평가를 수행하고, 이를 363개의 영상을 통해 새로운 방법과 기존의 방법을 비교하였다. 실험 결과 제안된 방법의 실제 주관적 화질과의 상관도는 다른 기존방법보다 높은 것으로 나타났다.

병원자료에 근거한 혈액 및 혈액화학 검사항목의 참고구간 설정 (Reference Intervals from Hospital-Based Data for Hematologic and Serum Chemistry Values in Dogs)

  • 권영욱;박선일
    • 한국임상수의학회지
    • /
    • 제27권1호
    • /
    • pp.66-70
    • /
    • 2010
  • Reference interval is critical for interpreting laboratory results, monitoring response to therapy and predicting the prognosis of the patients in clinical settings. The aim of the present study was to update established reference intervals for routine hematologic and serum chemistry values for a population of clinically healthy dogs (range, 1-8 years) seen in an animal hospital. Blood was obtained by venipuncture while animals were physically restrained, and samples were analyzed for 9 chemistries on MS9-5H (Melot Schloesing Lab, France) and 6 hematology on Vet Test 8008 (IDEXX, USA). Data from 105 dogs (52 males and 53 females) for hematology and 113 dogs (37 males and 76 females) for chemistry were used to determine reference intervals using the parametric, nonparametric and bootstrap methods. Prior to analysis, all parameters were tested for normal distribution using Anderson-Darling criterion. Of the 9 biochemical analytes, alkaline phosphatase, alanine aminotransferase, aspartate aminotransferase, creatinine, total protein, and glucose concentrations did not fit normal distribution for both original and transformed data. All but eosinophil count satisfied normal distribution for either original or transformed data. Parametric method can be used for original cholesterol concentrations, RBC, WBC, and neutrophil counts. This technique can also be used for power-transformed values of blood urea nitrogen concentrations and for logarithm of lymphocyte and monocyte counts. Non-parametric or bootstrap method was the preferred choice for the remaining 7 biochemical parameters and eosinophil count as they did not follow normal distributions. All three statistical techniques performed in similar reference intervals. When establishing reference intervals for clinical laboratory data, it is essential to assess the distribution of the original data to increase the accuracy of the interval, and non-parametric or bootstrap methods are of alternative for the data that do not fit normal distribution.

CTIA 바이어스 상쇄회로를 갖는 초점면 배열에서 마이크로 볼로미터의 온도변화 해석 (Analyses of temperature change of a u-bolometer in Focal Plane Array with CTIA bias cancellation circuit)

  • 박승만
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2311-2317
    • /
    • 2011
  • In this paper, we study the temperature change of a ${\mu}$-bolometer focal plane array with a capacitive transimpedance amplifier bias cancellation circuit. Thermal analysis is essential to understand the performance of a ${\mu}$-bolometer focal plane array, and to improve the temperature stability of a focal plane array characteristics. In this study, the thermal analyses of a ${\mu}$-bolometer and its two reference detectors are carried out as a function of time. The analyses are done with the $30{\mu}m$ pitch $320{\times}240$ focal plane array operating of 60 Hz frame rate and having a columnwise readout. From the results, the temperature increase of a ${\mu}$-bolometer in FPA by an incident IR is estimated as $0.689^{\circ}C$, while the temperature increase by a pulsed bias as $7.1^{\circ}C$, which is about 10 times larger than by IR. The temperature increase of a reference detector by a train of bias pulses may be increased much higher than that of an active ${\mu}$-bolometer. The suppression of temperature increase in a reference bolometer can be done by increasing the thermal conductivity of the reference bolometer, in which the selection of thermal conductivity also determines the range of CTIA output voltage.

엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석 (Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test)

  • 양인영
    • 한국유체기계학회 논문집
    • /
    • 제14권1호
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.

Parameters affecting the seismic response of buildings under bi-directional excitation

  • Fontara, Ioanna-Kleoniki M.;Kostinakis, Konstantinos G.;Manoukas, Grigorios E.;Athanatopoulou, Asimina M.
    • Structural Engineering and Mechanics
    • /
    • 제53권5호
    • /
    • pp.957-979
    • /
    • 2015
  • The present paper investigates the influence of the orientation of the ground-motion reference axes, the seismic incident angle and the seismic intensity level on the inelastic response of asymmetric reinforced concrete buildings. A single storey asymmetric building is analyzed by nonlinear dynamic analyses under twenty bi-directional ground motions. The analyses are performed for many angles of incidence and four seismic intensity levels. Moreover three different pairs of the horizontal accelerograms corresponding to the input seismic motion are considered: a) the recorded accelerograms, b) the corresponding uncorrelated accelerograms, and c) the completely correlated accelerograms. The nonlinear response is evaluated by the overall structural damage index. The results of this study demonstrate that the inelastic seismic response depends on the orientation of the ground-motion reference axes, since the three individual pairs of accelerograms corresponding to the same ground motion (recorded, uncorrelated and completely correlated) can cause different structural damage level for the same incident angle. Furthermore, the use of the recorded accelerograms as seismic input does not always lead to the critical case of study. It is also shown that there is not a particular seismic incident angle or range of angles that leads to the maximum values of damage index regardless of the seismic intensity level or the ground-motion reference axes.

Feasibility Analysis of Alternative Electricity Systems by 2030 in the Post-Fukushima Era

  • Park, Nyun-Bae;Lee, Sanghoon;Han, Jin-Yi;Jeon, Eui Chan
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권1호
    • /
    • pp.59-68
    • /
    • 2014
  • The Fukushima nuclear accident in 2011 had an extensive impact on the national electricity plans. This paper outlines alternative electricity scenarios that meet the goals of nuclear phase-out and greenhouse gas (GHG) emission reduction. This paper also analyzes the results of each scenario in respect to the electricity mix, GHG emissions, costs and employment effects. The Long-range Energy Alternatives Planning system (LEAP) model was used to simulate the annual electricity demand and supply system from 2011 to 2030. The reference year was 2009. Scenarios are reference (where existing plans are continued), A1, A2, B1, B2, and C2 (where the levels of demand management and nuclear phase-out are different). The share of renewable energy in the electricity mix in 2030 for each scenario will be increased from about 1% in 2009 to 8% in the reference scenario and from 11% to 31% in five alternative scenarios. Total cumulative cost increases up to 14% more than the reference scenario by replacing nuclear power plants with renewable energy in alternative scenarios could be affordable. Deploying enough renewable energy to meet such targets requires a roadmap for electricity price realization, expansion of research, development and deployment for renewable energy technologies, establishment of an organization dedicated to renewable energy, and ambitious targets for renewable energy.

Measurements of the rheological properties of standard reference material 2490 using an in-line micro-Fourier rheometer

  • Smith R. S.;Glasscock J. A.
    • Korea-Australia Rheology Journal
    • /
    • 제16권4호
    • /
    • pp.169-173
    • /
    • 2004
  • The control of the rheological properties of a fluid during processing is important and can determine the efficiency of the production in addition to the performance of the final product. The vast majority of process fluids are viscoelastic, hence an instrument that measures both the viscous and elastic properties of the material during processing would be of great practical use. However, most in-line instruments commercially available to date are only capable of measuring viscosity at a single shear rate. An in-line rheometer that measures both the viscous and elastic properties of fluids over a wide range of shear rates simultaneously has been described in a previous publication (Glasscock et at., 2003) in which the results of measurements on flowing sunflower oil were presented. Before this instrument can be used in an industrial situation, it must be demonstrated that the generated results are the same as, or bear some fixed relationship to, the results obtained by conventional off-line rheometers. To this end, the present investigation describes the measurements of a standard reference fluid, polyisobutylene dissolved in 2,6,10,14-tetramethylpentadecane, labelled SRM2490 by the National Institute of Standards and Technology (NIST) in the USA. The results obtained using the in-line rheometer show remarkably good correlation for viscosity, using a modified Cox­Merz rule, with the results supplied with the reference material from NIST.

백금저항온도센서를 이용한 국가교정기관의 교정능력 평가 및 실험방법 (Experimental method and evaluation of the calibration capability for the national calibration centers using the platinum resistance temperature sensors)

  • 감기술;유성호;김성민;이인식
    • 센서학회지
    • /
    • 제14권4호
    • /
    • pp.231-236
    • /
    • 2005
  • Calibration capability was evaluated using the reference-grade platinum resistance thermometer (PRT) in the temperature range of $-50^{\circ}C$ to $250^{\circ}C$ for the national calibration centers. The reference-grade PRT was calibrated at the several fixed points, which was composed by the freezing points of Sn, In, the melting point of Ga and the triple point of water and Hg, before and after the round-robin test (RRT) experiments. The temperature scale of reference-grade PRT was compared to the local standard PRT's using the system of the national calibration centers. $E_{n}$ values was calculated by the temperature difference between the reference-grade PRT and the local standard PRT, and the best measurement capability. Finally, the capability of the national calibration centers was evaluated by the $E_{n}$ values.

신경망을 이용한 PID 제어기의 자동동조 및 기준모델 적응제어 (Auto-tuning of PID controller using Neural Networks and Model Reference Adaptive control)

  • 김순태;김종석;서양오;박세진;홍연찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2299-2301
    • /
    • 2000
  • In this paper, the design of PID controller using Neural networks for the control of non-linear system is presented. First, non-linear system is identified using BPN(Backpropagation Network) algorithm. This identified model is connected to the PID controller and the parameters of PID controller are updated to the direction of reducing the difference between the identified model output and model reference output in arbitrary input signal. Therefore, identified model output tracks the model reference output in an acceptable error range and the parameters of controller are updated adaptively. The output of the system has a good performance in case of both noisy and noiseless model reference and we can control the system stable in off-line when the dynamics of the system is changed.

  • PDF