• Title/Summary/Keyword: reference range

Search Result 1,775, Processing Time 0.026 seconds

MT surveys near Century Zinc Mine, NW Queensland, Australia (호주 Century 아연 광산에서의 MT 탐사)

  • Lee, Tae-Jong;Lee, Seong-Kon;Song, Yoon-Ho;Cull, James
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.345-352
    • /
    • 2007
  • Two-dimensional (2D) MT surveys near the Century mine in Australia have been performed with very far remote reference in Esashi, Japan (RR_ESS) as well as Gregory Downs (RR_GREG), which are roughly 6,400 km and 80 km apart from the survey area, respectively. Good quality of MT data could be obtained by remote reference processing with RR_GREG, while the coherency of magnetic fields between field sites and RR_ESS was not sufficient to be used as remote data. Both 2D and 3D inversion of 2D profile data represented the general geological structure beneath the survey area. The main target of the survey, Termite Range Fault, appeared as a boundary between a conductive block to the north and a resistive block to the south in the reconstructed resistivity section, and is inclined slightly to the north-east direction.

The Generation of Vacuum Scale Using the Vapour Pressure of Water (물의 증기압을 이용한 진공도눈금의 생성)

  • Seong D. J.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.180-185
    • /
    • 2005
  • The possibility of generation of the vacuum scale using the vapour pressure of water was evaluated. The range of vacuum from 3.3 kPa to 101.3 kPa was corresponds the vapour pressure of water in the temperature range from $25^{\circ}C$ to $100^{\circ}C$ The measured values of the vapour pressure of water were agreed within the deviation of $5\%$ comparing to reference value. This result shows the vapour pressure of water can be used as an secondary reference of the vacuum scale. Moreover it shows the thermo-dynamical properties such as, triple point, temperature-pressure curve of a material have a applicability in the vacuum scale as a reference in corresponding range of vacuum.

Measurement of Proton Beam Dose-Averaged Linear Energy Transfer Using a Radiochromic Film

  • Seohyeon An;Sang-il Pak;Seonghoon Jeong;Soonki Min;Tae Jeong Kim;Dongho Shin;Youngkyung Lim;Jong Hwi Jeong;Haksoo Kim;Se Byeong Lee
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.80-87
    • /
    • 2022
  • Purpose: Proton therapy has different relative biological effectiveness (RBE) compared with X-ray treatment, which is the standard in radiation therapy, and the fixed RBE value of 1.1 is widely used. However, RBE depends on a charged particle's linear energy transfer (LET); therefore, measuring LET is important. We have developed a LET measurement method using the inefficiency characteristic of an EBT3 film on a proton beam's Bragg peak (BP) region. Methods: A Gafchromic EBT3 film was used to measure the proton beam LET. It measured the dose at a 10-cm pristine BP proton beam in water to determine the quenching factor of the EBT3 film as a reference beam condition. Monte Carlo (MC) calculations of dose-averaged LET (LETd) were used to determine the quenching factor and validation. The dose-averaged LETs at the 12-, 16-, and 20-cm pristine BP proton beam in water were calculated with the quenching factor. Results: Using the passive scattering proton beam nozzle of the National Cancer Center in Korea, the LETd was measured for each beam range. The quenching factor was determined to be 26.15 with 0.3% uncertainty under the reference beam condition. The dose-averaged LETs were measured for each test beam condition. Conclusions: We developed a method for measuring the proton beam LET using an EBT3 film. This study showed that the magnitude of the quenching effect can be estimated using only one beam range, and the quenching factor determined under the reference condition can be applied to any therapeutic proton beam range.

GENERATION OF AIRBORNE LIDAR INTENSITY IMAGE BY NORMALIZAING RANGE DIFFERENCES

  • Shin, Jung-Il;Yoon, Jong-Suk;Lee, Kyu-Sung
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.504-507
    • /
    • 2006
  • Airborn Lidar technology has been applied to diverse applications with the advantages of accurate 3D information. Further, Lidar intensity, backscattered signal power, can provid us additional information regarding target's characteristics. Lidar intensity varies by the target reflectance, moisture condition, range, and viewing geometry. This study purposes to generate normalized airborne LiDAR intensity image considering those influential factors such as reflectance, range and geometric/topographic factors (scan angle, ground height, aspect, slope, local incidence angle: LIA). Laser points from one flight line were extracted to simplify the geometric conditions. Laser intensities of sample plots, selected by using a set of reference data and ground survey, werethen statistically analyzed with independent variables. Target reflectance, range between sensor and target, and surface slope were main factors to influence the laser intensity. Intensity of laser points was initially normalized by removing range effect only. However, microsite topographic factor, such as slope angle, was not normalized due to difficulty of automatic calculation.

  • PDF

Design and Fabrication of an NIR Grism Si Optical Area Sensor Spectrometer with In-band Reference Wavelength (대역 내 기준 파장을 갖는 근적외선 그리즘 실리콘 광 면 센서 분광기 설계 및 제작)

  • Song, Jae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.28-34
    • /
    • 2017
  • An NIR grism Si optical area sensor spectrometer with in-band reference wavelength is designed and fabricated. It is composed of a transmission type diffraction grating (spatial density 300 line/mm), a rectangular N-BK7 prism (apex angle 30 degree), NIR filter(cutoff wavelength 720 nm), an imaging convex lens(focal length 50 mm F1.8) and an IR modified DSLR camera (Canon EOS40D) of Si optical area sensor ($3,888{\times}2,592$ pixels, pixel size $5.710{\mu}m$). "In-band reference wavelength function" is implemented using non-dispersive 0th diffraction order optical beam. The NIR grism spectrometer is tested in a laboratory using a halogen lamp and a Neon lamp. And the spectrometer is used in an astronomy field for obtaining the planet Jupiter NIR spectrum. In-band reference wavelength i.e. un-deviation wavelength is 846 nm, an wavelength resolution is 0.3027 nm/pixel, an wavelength resolving power is 2,794 and an wavelength range is 650~1,000 nm.

A Security Reference Model for the Construction of Mobile Banking Services based on Smart Phones

  • Shin, Yong-Nyuo;Shin, Woo-Chang
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.11 no.4
    • /
    • pp.229-237
    • /
    • 2011
  • As smart phones have become widely adopted, they have brought about changes in individual lifestyles, as well as significant changes in the industry. As the mobile technology of smart phones has become associated with all areas of industry, it is not only accelerating innovation in other industries such as shopping, healthcare service, education, and finance, but is also creating new markets and business opportunities. The preparation of thorough security measures for smart phones is increasing in demand. While offering excellent mobility and convenience, smart phones can be exposed to a range of violation threats. In particular, it is necessary to make efforts to develop a security system that can preemptively cope with potential security threats in the banking service area, which requires a high level of reliability. This paper suggests a security reference model that is considered for the smart phone-based joint mobile banking development project being undertaken by the Bank of Korea in 2010. The purpose of this study is to make a security reference model for a reliable smart phone-based mobile financial service, by recognizing the specific security threats directed toward smart phones, and providing countermeasures to these security threats. The proposed mobile banking security reference model is useful in improving system security by systematically analyzing information security threats to the mobile financial service, and by presenting the guideline for the preparation of countermeasures.

Reference value of serum amyloid P : a systematic review (혈청 아밀로이드 P (SAP)의 정상 참고치 탐색을 위한 문헌 고찰)

  • Park, Sunju;Jung, Jeeyoun;Jang, Soobin
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.23 no.2
    • /
    • pp.91-99
    • /
    • 2019
  • Objectives : The aim of this study was to examine the reference value of biomarker serum amyloid p (SAP) to diagnose blood stasis objectively. Methods : Pubmed-Medline, Cochrane library, EMBASE were searched using the key words 'SAP' and 'serum amyloid p' in June 2018. Original articles of human adults that published in English, studies that recruited from the clinical research settings or well defined population based cohorts were only included. Results : A total of 12 studies were selected to extract the reference value of SAP. It was between 8.5 ng/mL (0.0085 mg/L) to 57.5 mg/L. Although the disease varied, most of them showed elevated SAP levels in the disease group (1.1-1.5 times). Conclusions : This study is meaningful in that it summarizes the results of previous researches of SAP, which has the potential to be diagnostic index of blood stasis.

A New Reference Range of Serum Anion Gap (혈청 Anion gap의 새로운 범위에 관한 연구)

  • Shin Young-Ju;Cheon Hae-Won;Choi Byung-Min;Yoo Kee-Hwan;Hong Young-Sook;Lee Joo-Won;Kim Soon-Kyum
    • Childhood Kidney Diseases
    • /
    • v.2 no.1
    • /
    • pp.9-13
    • /
    • 1998
  • Purpose: The old reference range of serum anion gap(AG) may be excessive compared with value measured by new electrolyte analyzers. Therefore, we studied to establish a new reference range of AG using an autoanalyzer. Methods: With the use of analyzer(Hitachi 747 by enzymatic methods), serum Na and Cl were measured, and with the use of analyzer(CX-3 by differental rage pH), serum $TCO_2$ was measured. We measured AG(=Na-($Cl+HCO_3$)) in 395 stable patients with normal serum albumin and creatinine levels of the pediatric in-patients and out-patients for preoperative examination from march 1997 to July 1997. Results: The normal serum$ AG(mean{\pm}SD)$ were neonate, $11.2{\pm}3.2$ mEq/L; infancy, $11.8{\pm}2.7$ mEq/L; early childhood, $12{\pm}2.7$ mEq/L; late childhood, $11.7{\pm}3.2$ mEq/L; adolescence, $9.6{\pm}2.7$ mEq/L; adult, $9.0{\pm}2.7$ mEq/L. Normal serum AG in more than 10 years of age was significantly lower than the previous normal value and also the difference of AG between more than 10 years and less than 10 years was statistically significant(P<0.05). Conclusions: We suggest to measure serum AG according to each type of analyzers.

  • PDF

A 3.2Gb/s Clock and Data Recovery Circuit without Reference Clock for Serial Data Communication (시리얼 데이터 통신을 위한 기준 클록이 없는 3.2Gb/s 클록 데이터 복원회로)

  • Kim, Kang-Jik;Jung, Ki-Sang;Cho, Seong-Ik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.72-77
    • /
    • 2009
  • In this paper, a 3.2Gb/s clock and data recovery (CDR) circuit for a high-speed serial data communication without the reference clock is described This CDR circuit consists of 5 parts as Phase and frequency detector(PD and FD), multi-phase Voltage Controlled-Oscillator(VCO), Charge-pumps (CP) and external Loop-Filter(KF). It is adapted the PD and FD, which incorporates a half-rate bang-bang type oversampling PD and a half-rate FD that can improve pull-in range. The VCO consists of four fully differential delay cells with rail-to-rail current bias scheme that can increase the tuning range and tuning linearity. Each delay cell has output buffers as a full-swing generator and a duty-cycle mismatch compensation. This materialized CDR can achieve wide pull-in range without an extra reference clock and it can be also reduced chip area and power consumption effectively because there is no additional Phase Locked- Loop(PLL) for generating reference clock. The CDR circuit was designed for fabrication using 0.18um 1P6M CMOS process and total chip area excepted LF is $1{\times}1mm^2$. The pk-pk jitter of recovered clock is 26ps at 3.2Gb/s input data rate and total power consumes 63mW from 1.8V supply voltage according to simulation results. According to test result, the pk-pk jitter of recovered clock is 55ps at the same input data-rate and the reliable range of input data-rate is about from 2.4Gb/s to 3.4Gb/s.

DATUM PROBLEM OF NETWORK-BASED RTK-GPS POSITIONING IN TAIWAN

  • Yeh, Ta-Kang;Hu, Yu-Sheng;Chang, Ming-Han;Lee, Zu-Yu;Liou, Yuei-An
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.90-94
    • /
    • 2007
  • The conventional single-reference station positioning is affected by systematic errors such as ionospheric and tropospheric delay, so that the rover must be located within 10 km from the reference station in order to acquire centimeter-level accuracy. The medium-range real-time kinematic has been proven feasible and can be used for high precision applications. However, the longer of the baseline, the more of the time for resolving the integral ambiguity is required. This is due to the fact that systematic errors can not be eliminated effectively by double-differencing. Recently, network approaches have been proposed to overcome the limitation of the single-reference station positioning. The real-time systematic error modeling can be achieved with the use of GPS network. For expanding the effective range and decreasing the density of the reference stations, Land Survey Bureau, Ministry of the Interior in Taiwan set up a national GPS network. In order to obtain the high precision positioning and provide the multi-goals services, a GPS network including 66 stations already been constructed in Taiwan. The users can download the corrections from the data center via the wireless internet and obtain the centimeter-level accuracy positioning. The service is very useful for surveyors and the high precision coordinates can be obtained real time.

  • PDF