• Title/Summary/Keyword: reference level

Search Result 2,463, Processing Time 0.029 seconds

Assessment of Effective Dose for General Radiography of Adults Based on Diagnostic Reference Level(DRL) by Using PCXMC Program (진단참고준위(DRL)를 기준으로 PCXMC 프로그램을 이용한 성인의 일반촬영 부위별 유효선량 평가)

  • Jeong, Hee-Cheol;Lee, SamYol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.807-812
    • /
    • 2018
  • In this study, we investigated the conditions used in setting the recommendation level of general radiography diagnostic reference and tried to evaluate the effective dose and biological evaluation using PCXMC v2.0 program. As a result based on the effective dose of male in ICRP 60, the highest Pelvis AP was 0.794 mSv. The lowest Chest PA was 0.050 mSv. In the case of ICRP 103, the highest T-Spine AP was 0.906 mSv The lowest Chest PA was 0.052 mSv. For 40 years old male and female adults, effective doses of general radiography were evaluated and even if the medical exposures are not subject to the limit of dose, efforts should be made to reduce the medical exposures of the people by keeping the dose below the recommended amount in order to minimize the probable effect of radiation hazard.

A Study on Establishment of the Optimal Target Exposure Index for Skull Radiography Based on Diagnostic Reference Level (진단참고수준 기반 두부 방사선검사의 최적 목표노출지수 설정에 관한 연구)

  • Park, Hye-Min;Yoon, Yong-Su;Kim, Eun-Hye;Jeong, Hoi-Woun;Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.599-605
    • /
    • 2021
  • The International Electrotechnical Commission (IEC) 62494-1 has defined the exposure index (EI) that have a proportional relationship with the dose incident on the image receptor, and target exposure index (EIT), deviation index (DI). In this study, an appropriate EIT for skull radiography was established through the diagnostic reference level (DRL) and changes in DI were confirmed. Entrance surface dose (ESD) and EI were obtained using the computed radiography system displayed the EI as per IEC on console and skull phantom by experiment based on the national average exposure conditions announced in 2012 and 2019. And appropriate EIT was established by applying the DRL in 2012 and 2019. As a results, the EIT is changed according to the change in the DRL, and the exposure condition that becomes the ideal DI according to the change in the EIT also has a difference of about 1.41 times. DRL is recommended to optimize the patient dose, however it is difficult to measure in real time at medical institutions whereas EI and DI are displayed on the console at the same time as exposure. When the EIT is set based on the DRL and the DI is closed to an ideal value, it is useful as a patient dose management tool. Therefore, when the EIT is periodically managed along with the revision of the DRLs, the patient dose can be optimized through the EI, EIT and DI.

Assessment of DRL for Computed Tomography in Local Hospital (지역병원에서의 전산화단층촬영 검사에 대한 DRL 평가)

  • Choi, Seok-Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.619-625
    • /
    • 2022
  • In the field of imaging medicine, computed tomography is one of the most common test methods and one of the most frequently used test methods in hospitals. However, it is accompanied by a very high radiation exposure compared to other test methods. In order to reduce exposure, CT scans should be performed only when absolutely necessary, and even if the tests are performed because they are absolutely necessary, a protocol that serves the purpose of the test and allows the test to be performed in a small dose should be used. In this study, we wanted to learn about the most up-to-date radiation dose usage information used by the region's leading general hospitals and develop a diagnostic reference level (DRL). In the experimental results, the Head CT and Abdomen CT tests showed that DLP was higher than the NRPB (U.K) and Korean DRL. The DLP values used by Chest CT were low for all 3 types of CT devices. The hospital found that efforts to reduce exposure should be made during CT examinations, and in particular, Head CT and Abdomen CT determined that efforts to reduce exposure were necessary.

Method of Generating Information Signals in the System Industrial Internet of Things

  • Aleksandr Serkov;Nina Kuchuk;Bogdan Lazurenko;Alla Horiuskina
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.4
    • /
    • pp.206-210
    • /
    • 2024
  • Industrial facilities that use modern IT technologies require the ensured reliability and security of information in automated enterprise management. Concurrently, so as to ensure a high quality of communication, it is necessary to expand the bandwidth of communication channels, which are limited by the physical parameters of the radio frequency spectrum. In order to overcome this contradiction, we propose the application of technology fundamental to ultra-wideband signals, in which the ratio between the bandwidth and its central part is greater than "one". For this reason, the information signal is emitted without a carrier frequency - simultaneously within the entire frequency band - provided that the signal level is lower than the noise level. For the transmission of information content, the method of positional-time coding is used, in which each information bit is encoded by hundreds of ultrashort pulses that arrive within a certain sequence. Mathematical models of signals and values observed in wireless communication systems with autocorrelation reception of modulated ultra-wideband signals are furthermore recommended. These assist in identifying features of the dependence of the error probability on the normalized signal-to-noise ratio and the signal base. Comparative analysis has shown that the best noise immunity of the systems considered in this paper is the communication system, which uses the time separation of the reference and information signals. During the first half of the bit interval, the switch closes the output of the transmitter directly to the generator of the ultra-wideband signal - forming a reference signal. In the middle of the bit interval, the switch alternates the output to one of two possible positions depending on the encoding signal - "zero" or "one", forming the information part of the ultra-wideband signal. It should also be noted that systems with autocorrelation reception and separate transmission of reference and information signals, provide a high level of structural signal secrecy. Furthermore, they provide the reliable transmission of digital information, especially in interference conditions.

An Analysis on Reference Information Service of Teacher Librarians to Instruction in Korea (정보전문가의 교수활동지원을 위한 참고정보서비스 실태 분석 - 사서교사의 참고정보서비스를 중심으로 -)

  • Jung, Jong-Kee
    • Journal of Korean Library and Information Science Society
    • /
    • v.38 no.1
    • /
    • pp.211-230
    • /
    • 2007
  • The purpose of this study is to survey the reference information service participation to school library human resources, to compare the independent variables with reference information service participation, and to discern what the important impacts on the differences of reference information service participation are. The 254 questionaries used were collected from December 1, 2006 to December 31, 2006 to the 327 school library employees. In this study, it is proved that there are differences between the Reference Information Service Participation of school library human resources and independent variables: gender, the level of school library, length of service, employment style. Tips for the reference information service participation of school library human resources were provided based on inadequacies and other findings revealed through this study.

  • PDF

An analysis of the Digital Reference Services of Teaching & Learning Aid Centers under the Metropolitan City and Provincial Offices of Education in Korea (국내 광역시.도 교육청 교수학습지원센터의 디지털참고봉사 제공과 이용 현황 분석)

  • Jung Jong-Kee
    • Journal of Korean Library and Information Science Society
    • /
    • v.37 no.3
    • /
    • pp.173-191
    • /
    • 2006
  • Examinations and analysis were done to understand the digital reference services of the Teaching & Learning Aid Centers under 16 metropolitan city and provincial offices of education. The data used were collected from July 3. 2006 to July 15. 2006 by the direct contacts on their main homepages and recording the question and answer transcripts. It was proven that 13 of the 16 Teaching & Learning Aid Centers have done the reference services. In this study, several characteristics-whether the digital reference service was done or not, interface access level, its title, its communication tool, reference question number, reference question style, answer rate, etc-were analyzed. Tips for the future development were provided on the basis of the inadequacies and other findings revealed through this study.

  • PDF

A Study of Analytical Sensitivity on TDM Test Kit in Clinical Chemistry (약물검사 키트의 분석 민감도에 대한 연구)

  • Chang, Sang Wu;Kim, Nam Yong;Lee, Hee Gyung;Kim, Hyun Jung;Lee, Yun Jung;Jin, Ok Bae;Kim, Mi Gyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.127-130
    • /
    • 2004
  • Analytical sensitivity on TDM test is the lowest concentration that can be distinguished from background noise. The aim of study was to evaluate analytical sensitivity that is also referred to as the lower limit of detection(LLD) about difference between zero calibrator and isotonic saline sample. We tested for 10 days with zero calibrators and 0.85% saline samples while running trilevel control samples under control. Raw data divided by two groups calculated mean and standard deviation from two sample populations and analytical sensitivity by ${\bar{X}}+2SD$. In comparison with isotonic saline samples and zero calibrators, there were significant differences in phenytoin, phenobarbital and vancomycin, etc. Especially analytical sensitivity on phenytoin is at the same level as the upper limit of analytical measurement range with $40{\mu}g/mL$. We think the cause of this is matrix interference. In conclusion, we were sure that standard protocol for analytical sensitivity as lower limit of analytical measurement range on TDM test must be measured with zero standard rather than an isotonic saline sample and type 1 reagent DW for reducing matrix effects within interactions between different materials in a mixture.

  • PDF

Generation of Business Process Reference Model Considering Multiple Objectives

  • Yahya, Bernardo Nugroho;Wu, Jei-Zheng;Bae, Hye-Rim
    • Industrial Engineering and Management Systems
    • /
    • v.11 no.3
    • /
    • pp.233-240
    • /
    • 2012
  • The implementation of business process management (BPM) systems in large number of business organizations transforms BPM system into such a level of maturity and tends to collect large repositories of business process (BP) models. This issue encourages BP flexibility that leads to a large number of process variants derived from the same model, but differing in structure, to be stored in the large repositories of BP models. Therefore, the repositories may include thousands of activities and related business objects with variation of requirements and quality of service. It is a common practice to customize processes from reference processes or templates in order to reduce the time and effort required to design and deploy processes on all levels. In order to address redundancy and underutilization problems, a generic process model, called as reference BP, is absolutely necessary to cover the best of process variants. This study aims to develop multiple-objective business process genetic algorithm (MOBPGA) to find a set of non-dominated (Pareto) solutions of business reference model to enhance conventional approach which considered only a single objective on creating BP reference model by using proximity score measurement. A mixed-integer linear program is constructed to evaluate performance of the proposed MOBPGA on small-scale problems by using standard measures for multiple-objective techniques. The results will show the viability of applying MOBPGA in terms of simultaneously maximizing proximity score measurement, minimizing total duration, and total costs of the selected reference model.

The effects of performance, legitimacy, and reference group on strategic positional change - Evidence from North American Crude Petroleum and Natural Gas Industry - (성과 피드백, 정당성, 그리고 준거집단 성과가 리포지셔닝에 미치는 영향 - 북미 원유 및 천연가스 산업 분석을 중심으로 -)

  • Choi, Sung-Ho
    • Management & Information Systems Review
    • /
    • v.36 no.3
    • /
    • pp.17-35
    • /
    • 2017
  • This study investigates the determinants of strategic positional change. Specifically, the study suggests performance feedback affects to a firm's strategic repositioning. Performance feedback is a concept that a firm decides whether success or not by comparing its performance relative to its aspiration level. Prior studies successively discover diverse behaviors. The study suggests three unexplored relationships between performance gaps and strategic positioning. First, when a firm's performance is below relative to its aspiration level, that firm's strategic position will be deviate from the industry norm. Second, as the degree of industrial density increases, the tendency that a firm's strategic position becomes deviate from the industry norm decreases. Third, when the degree of reference group's performance decreases, the tendency that a firm's strategic position becomes deviate from the industry norm decreases. For empirical analysis, this study examines data of 538 firms that in North America crude petroleum and natural gas industry. The result reveals that the direction of a firm's strategic change is shaped when firms' performance is below relative to aspiration level. Also, this relationship is moderated as industrial density changes or when reference groups' performance decreases. This study contributes to the current literature by explaining how a firms' strategic position is decided. Also, this study reveals that reference groups' performance could affect to organizational choice.

  • PDF

The Reciprocal Causal Relationship between Social Activities and Health with Reference to the Cognitive Function Level among Community-dwelling Older Adults: A Cross-Lagged Panel Analysis

  • Kim, Da Eun;Yoon, Ju Young
    • Research in Community and Public Health Nursing
    • /
    • v.28 no.1
    • /
    • pp.13-22
    • /
    • 2017
  • Purpose: The aim of this study is to examine the reciprocal causal relationship between social activities and health with reference to the cognitive function level among community-dwelling older adults. Methods: We conducted a longitudinal data analysis using the $4^{th}$ (Time 1) and $5^{th}$ (Time 2) waves from the Korean Longitudinal Study of Ageing adopting cross-lagged panel analysis (CLPA). Results: A total of 3,473 community-dwelling older adults were included in the analysis: 2,053 in the normal cognitive function group, 912 in the mild cognitive impairment group, and 508 in the moderate to severe cognitive impairment group. The CLPA revealed that higher levels of social activities at Time 1 significantly influenced better subjective health perception at Time 2 in all three groups. In addition, better subjective health perception at Time 1 significantly influenced higher levels of social activities at time 2 only in the normal cognitive function group. Conclusion: This study demonstrates that participating in social activities has positive effects on health regardless of the cognitive function level in community-dwelling older adults. This finding suggests that there is a need to develop strategies that can be used to encourage older adults with cognitive decline to maintain participation in social activities.