• Title/Summary/Keyword: reference equipment

Search Result 439, Processing Time 0.023 seconds

SYSTEM ARCHITECTURE OF THE TELEMATICS POSITIONING TESTBED

  • Kim, Young-Min;Kim, Bong-Soo;Choi, Wan-Sik
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.349-352
    • /
    • 2005
  • The telematics positioning testbed is an infrastructure to test and verify positioning technology, the sub-component of telernatics system. The positioning testbed provides the environment of performance analysis for acquisition of static and dynamic positioning information using telematics vehicle. This testbed consists of onboard positioning system, positioning reference station and lab positioning server. The onboard positioning system equipped in telematics vehicle, consists of target positioning system, reference positioning system, and analysis tool. A equipment acquiring high precision positioning data obtained from GPS combined with IMU was set as a reference positioning system. Analysis tool compares observed positioning data with high precision positioning information from a reference positioning system, and processes positioning information. Positioning reference station is RTK system used for reducing atmosphere error, and it transmits corrected information to reference positioning system. Positioning server which is located at laboratory manages positioning database and provides monitoring data to integrated testbed operating system. It is expected that the testbed supports commercialization of telernatics technology and services, integrated testing among component technology and verification.

  • PDF

A Study on the Calculation of Reference Impedances in Domestic Low-Voltage Power System (저압설비 플리커 특성평가를 위한 국내 저압계통 기준 임피던스 산정 연구)

  • Kang, Moon-Ho;Song, Yang-Hoe;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1651-1655
    • /
    • 2011
  • The reference impedances which is about 95% supply impedance value of residential consumers' supply impedances was published by IEC in 1980. The reference impedances are the standard values for use in determining the voltage disturbance characteristics of electrical equipment like the flicker. In IEC 60725, the reference impedances for premises having service current capacities less than 100A per phase and for service current capacities more than 100A per phase are recommended. And these reference impedances are targeted for the countries using 50Hz power frequency. Because of the frequency difference, the reactance values of the reference impedances will be increased in 60Hz power system like Korea, And also the reference impedances are different significantly each other according to declared voltage variation, power consumption and service wire length etc. Therefore It is needed to calculate the reference impedances suitable for domestic low-voltage power system. In this paper, the reference impedances for service current capacities less than 100A in 220/380V, 60Hz single-phase two wire and three-phase four wire low-voltage system are calculated, And the equations for service current capacities more than 100A to calculate the modulus value of maximum supply impedances are suggested base on IEC 60725 and the reference impedances for those are calculated on service current of 100A per phase.

Evaluating the Application of Portable Safety Equipment in Nuclear Power Plants using Multi-unit PSA (다수기 PSA 기반 원자력 발전소 이동형 안전 설비 활용성 평가)

  • Jae Young Yoon;Ho-Gon Lim;Jong Woo Park
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.110-120
    • /
    • 2023
  • Following the Fukushima accident, portable equipment employed as accident mitigating systems have been installed and operated to reduce core damage and large early release frequencies. In addition, the establishment of an accident management strategy has gained importance. This study investigated the current status of portable equipment including the international portable equipment FLEX (diverse and flexible coping strategies), and domestic portable equipment multi-barrier accident coping strategy (MACST). Research on optimal utilization of MACST remains insufficient. As a preliminary study for establishing an optimal strategy, sensitivity studies were conducted to facilitate the priority of use on portable equipment, number of portable equipment, and dependency of operator actions based on a multi-unit probabilistic safety assessment model. The results revealed the conditions that reduced the multi-unit and site conditional core damage probabilities, indicating the optimal strategy of MACST. The results of this study can be used as a reference for establishing an optimal strategy that utilizes domestic safety equipment in the future.

A Study on Optimal Equipment Fleet focused on Pusher-loaded Scrapers in Earthmoving Operation (토사운반 공정의 스크레이퍼 중심 최적 장비조합에 관한 연구)

  • Lee, Hyung-Guk;Son, Chang-Baek;Lee, Dong-Eun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.39-42
    • /
    • 2012
  • Pusher-Loaded Scrapers are important construction equipment for large earthmoving operations. Production rates of a Pusher-Loaded Scraper vary greatly in accordance with the temperature or elevation, the equipment performance, haul speed, haul-road conditions, the method of loading, and Number of scrapers per one pusher. Determining of most economical scrapers fleet regarding the size of equipment, model name, and number of scrapers demands time-consuming calculation because it needs to reference of varied performance charts or tables and repeat complicated calculation. In this study, decision-making support system for the Optimal Pusher-loaded Scrapers Fleet is suggested for the purpose of calculating easily and handling effectively variables which are changed depend of the work conditions. The prototype of this program is developed using MATLAB. And the Database of Pusher-loaded Scraper embodies Performance chart & Retarder chart, soil properties, and calculation-support table.

  • PDF

Design and Simulation of analog controller for 3 Phase PWM Converter Based on Stationary Reference Frame (3상 PWM Converter를 위한 정지 좌표계법 Analog 제어기 설계 및 시뮬레이션)

  • 이영국;노철원;최종률
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.14-20
    • /
    • 1997
  • Due to several advantages of Pulse Width Modulated(PWM) Converter, such as unity power factor with low-harmonics and energy regeneration, PWM converter has been widely used in industrial application. In every application of energy conversion equipment, the design and implementation must be carried out considering performance and cost. High quality with low cost is the best choice for energy conversion equipment. High dc link voltage can reduce inverter and motor side losses and system dimension compare to low dc link voltage. Analog controller can make PWM converter cheaper without considerable degradation of the performance than digital controller. This paper shows the simplified analog controller-for 600V dc link voltage using stationary reference frame control and the simulation results.

  • PDF

Representation of Process Plant Equipment Using Ontology and ISO 15926 (온톨로지와 ISO 15926을 이용한 공정 플랜트 기자재의 표현)

  • Mun, Du-Hwan;Kim, Byung-Chul;Han, Soon-Hung
    • Korean Journal of Computational Design and Engineering
    • /
    • v.14 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • ISO 15926 is an international standard for the representation of process plant lifecycle data. However, it is not easy to implement the part 2-data model and the part 4-initial reference data because of their complexity in terms of data structure and shortages of related development toolkits. To overcome this problem, ISO 15926-7(part 7) is under development. ISO 15926-7 specifies implementation methods for sharing and exchange of process plant lifecycle data, which is based on semantic web technologies such as OWL, Web Services, and SPARQL. For the application of ISO 15926-7, this paper discusses how to represent technical specifications of process plant equipment by defining user-defined reference data and object information model with an example of reactor coolant pumps located in the reactor coolant system of an APR 1400 nuclear power plant.

An Experimental Study on IMP-based and DOB-based Controllers for Position Control of a BLDC Motor System

  • Dong Cheol Song;Seung Tae Hwang;Nebiyeleul Daniel Amare;Young Ik Son
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.2
    • /
    • pp.92-99
    • /
    • 2024
  • As semiconductor processes require several nanometers precision, the importance of motor control is increasing in semiconductor equipment. Due to unpredictable uncertainties such as friction and mechanical vibrations achieving precise position control in semiconductor processes is challenging. The internal model principle-based controller is a control technique that ensures robust steady-state performance by incorporating a model of the reference and disturbance. The disturbance observer-based controller is a prominent robust control technique implemented to cope with various nonlinearities and uncertainties. Provided that the two controllers can be designed to exhibit equivalent performance under certain conditions, this paper demonstrates through experiments that they yield identical results for the case of a BLDC position control problem. The experimental results also indicate that they can offer enhanced robustness compared with the conventional PID controller in the presence of a time-varying disturbance.

  • PDF

Finite element analysis of high-density polyethylene pipe in pipe gallery of nuclear power plants

  • Shi, Jianfeng;Hu, Anqi;Yu, Fa;Cui, Ying;Yang, Ruobing;Zheng, Jinyang
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.1004-1012
    • /
    • 2021
  • High density polyethylene (HDPE) pipe has many advantages over metallic pipe, and has been used in non-safety related application for years in some nuclear power plants (NPPs). Recently, HDPE pipe was introduced into safety related applications. The main difference between safety-related and non-safety-related pipes in NPPs is the design method of extra loadings such as gravity, temperature, and earthquake. In this paper, the mechanical behavior of HDPE pipe under various loads in pipe gallery was studied by finite element analysis (FEA). Stress concentrations were found at the fusion regions on inner surface of mitered elbows of HDPE pipe system. The effects of various factors were analyzed, and the influence of various loads on the damage of HDPE pipe system were evaluated. The results of this paper provide a reference for the design of nuclear safety-related Class 3 HDPE pipe. In addition, as the HDPE pipes analyzed in this paper were suspended in pipe gallery, it can also serve as a supplementary reference for current ASME standard on Class 3 HDPE pipe, which only covers the application for buried pipe application.

Development of the ISO 15926-based Classification Structure for Nuclear Plant Equipment (ISO 15926 국제 표준을 이용한 원자력 플랜트 기자재 분류체계)

  • Yun, J.;Mun, D.;Han, S.;Cho, K.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.12 no.3
    • /
    • pp.191-199
    • /
    • 2007
  • In order to construct a data warehouse of process plant equipment, a classification structure should be defined first, identifying not only the equipment categories but also attributes of an each equipment to represent the specifications of equipment. ISO 15926 Process Plants is an international standard dealing with the life-cycle data of process plant facilities. From the viewpoints of defining classification structure, Part 2 data model and Reference Data Library (RDL) of ISO 15926 are seen to respectively provide standard syntactic structure and semantic vocabulary, facilitating the exchange and sharing of plant equipment's life-cycle data. Therefore, the equipment data warehouse with an ISO 15926-based classification structure has the advantage of easy integration among different engineering systems. This paper introduces ISO 15926 and then discusses how to define a classification structure with ISO 15926 Part 2 data model and RDL. Finally, we describe the development result of an ISO 15926-based classification structure for a variety of equipment consisting in the reactor coolant system (RCS) of APR 1400 nuclear plant.

A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings (건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구)

  • Jeong, Young-Sun;Jung, Hae-Kwon;Jang, Hee-Kyung;Yu, Ki-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.