• Title/Summary/Keyword: reference energy

Search Result 1,629, Processing Time 0.035 seconds

Measurement of Proton Beam Dose-Averaged Linear Energy Transfer Using a Radiochromic Film

  • Seohyeon An;Sang-il Pak;Seonghoon Jeong;Soonki Min;Tae Jeong Kim;Dongho Shin;Youngkyung Lim;Jong Hwi Jeong;Haksoo Kim;Se Byeong Lee
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.80-87
    • /
    • 2022
  • Purpose: Proton therapy has different relative biological effectiveness (RBE) compared with X-ray treatment, which is the standard in radiation therapy, and the fixed RBE value of 1.1 is widely used. However, RBE depends on a charged particle's linear energy transfer (LET); therefore, measuring LET is important. We have developed a LET measurement method using the inefficiency characteristic of an EBT3 film on a proton beam's Bragg peak (BP) region. Methods: A Gafchromic EBT3 film was used to measure the proton beam LET. It measured the dose at a 10-cm pristine BP proton beam in water to determine the quenching factor of the EBT3 film as a reference beam condition. Monte Carlo (MC) calculations of dose-averaged LET (LETd) were used to determine the quenching factor and validation. The dose-averaged LETs at the 12-, 16-, and 20-cm pristine BP proton beam in water were calculated with the quenching factor. Results: Using the passive scattering proton beam nozzle of the National Cancer Center in Korea, the LETd was measured for each beam range. The quenching factor was determined to be 26.15 with 0.3% uncertainty under the reference beam condition. The dose-averaged LETs were measured for each test beam condition. Conclusions: We developed a method for measuring the proton beam LET using an EBT3 film. This study showed that the magnitude of the quenching effect can be estimated using only one beam range, and the quenching factor determined under the reference condition can be applied to any therapeutic proton beam range.

Preliminary Evaluation of the Activity Concentration Limits for Consumer Goods Containing NORM

  • Jang, Mee;Chung, Kun Ho;Ji, Young Yong;Lim, Jong Myung;Kang, Mun Ja;Choi, Guen Sik
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.101-104
    • /
    • 2016
  • Background: To protect the public from natural radioactive materials, the 'Act on safety control of radioactive rays around living environment" was established in Korea. There is an annual effective dose limit of 1 mSv for products, but the activity concentration limit for products is not established yet. Materials and Methods: To suggest the activity concentration limits for consumer goods containing NORM, in this research, we assumed the "small room model" surrounding the ICRP reference phantom to simulate the consumer goods in contact with the human bodies. Using the Monte Carlo code MCNPX, we evaluate the effective dose rate for the ICRP reference phantom in a small room with dimension of phantom size and derived the activity concentration limit for consumer goods. Results and Discussion: The consumer goods have about 1600, 1200 and $19000Bq{\cdot}kg^{-1}$ for $^{226}Ra$, $^{232}Th$ and $^{40}K$, and the activity concentration limits are about six times comparing with the values of building materials. We applied the index to real samples, though we did not consider radioactivity of $^{40}K$, indexes of the some samples are more than 6. However, this index concept using small room model is very conservative, for the consumer goods over than index 6, it is necessary to reevaluate the absorbed dose considering real usage scenario and material characteristics. Conclusion: In this research, we derived activity concentration limits for consumer goods in contact with bodies and the results can be used as preliminary screening tool for consumer goods as index concept.

EXPERIMENTS ON THE PERFORMANCE SENSITIVITY OF THE PASSIVE RESIDUAL HEAT REMOVAL SYSTEM OF AN ADVANCED INTEGRAL TYPE REACTOR

  • Park, Hyun-Sik;Choi, Ki-Yong;Choi, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.53-62
    • /
    • 2009
  • A set of experiments has been conducted on the performance sensitivity of the passive residual heat removal system (PRHRS) for an advanced integral type reactor, SMART, by using a high temperature and high pressure thermal-hydraulic test facility, the VISTA facility. In this paper the effects of the opening delay of the PRHRS bypass valves and the closing delay of the secondary system isolation valves, and the initial water level and the initial pressure of the compensating tank (CT) are investigated. During the reference test a stable flow occurs in a natural circulation loop that is composed of a steam generator secondary side, a secondary system, and a PRHRS; this is ascertained by a repetition test. When the PRHRS bypass valves are operated 10 seconds later than the secondary system isolation valves, the primary system is not properly cooled. When the secondary system isolation valves are operated 10 or 30 seconds later than the PRHRS bypass valves, the primary system is effectively cooled but the inventory of the PRHRS CT is drained earlier. As the initial water level of the CT is lowered to 16% of the full water level, the water is quickly drained and then nitrogen gas is introduced into the PRHRS, resulting in the deterioration of the PRHRS performance. When the initial pressure of the PRHRS is at 0.1MPa, the natural circulation is not performed properly. When the initial pressures of the PRHRS are 2.5 or 3.5 MPa, they show better performance than did the reference test.

A Study on the Anthropometric Measurement, Health Condition and Nutritional Status of Female College Students in Kyunggido Area (경기지역, 일부 여대생의 신체계측치와 건강 및 영양섭취상태에 관한 연구)

  • 이정윤
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.10 no.5
    • /
    • pp.372-386
    • /
    • 2000
  • This study was conducted to assess anthropemrtric, health status, nutritional status, and their correlations in 120 female college students in Kyunggido area. The questionnaires on general living habits, food habits and energy expenditure were used, and nutrient intakes were estimated by Convenience Method. Anthropometric measurement, blood pressure, hemoglobin(Hb), hematocrit(Hct) were also determined. The mean values for BMI, RBW, and blood pressure of the subjects were 20.4$\pm$2.4, 92.9$\pm$16.0% and 108.9/69.6mmHg, respectively. Estimation of body fat from two sites of skinfolds thickness(20.6$\pm$6.0%) and four sites of skinfolds thickness(20.1 $\pm$8.6%) was similar, but different from BIA method(23.9$\pm$3.9%). The subjects of 36.9% considered themselves healthy, and 15.4% of them considered themselves not healthy. The mean values for Hb and Hct were 13.4$\pm$ 1.6g/dl, and 41.5$\pm$0.4%, respectively. The prevalence rates of iron deficiency assessed by Hb and Hct were found to be 19.8% and 6.3%, accordingly. The mean energy intake of subjects was 1,841 kcal. The proportion of energy derived from carbohydrates, protein and fat was 64.9%, 14.7%, and 20.4%, respectively As nutrient intake was compared to RDA for Koreans, intakes of energy, calcium, iron, and vitamin A fell short of recommendations. Intakes of energy, fat, iron, vitamin B$_2$, and niacin were positively correlated with total energy expenditure. These results suggest that appropriate reference data are important to maintain the health of female college students.

  • PDF

An Experimental Comparison Study of PVT Water and PVT Air Modules for Heat and Power Co-Generation (태양 열 전기 복합생산 PVT Water and PVT Air 모듈의 실험적 성능비교 연구)

  • Lee, Kwang-Seob;Putrayudha S., Andrew;Kang, Eun-Chul;Lee, Euy-Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.559-564
    • /
    • 2014
  • The development of photovoltaic-thermal (PVT) technology has been introduced in recent years specifically to increase PV efficiency. One of the characteristics of PV systems is that the electricity generation increases as the solar radiation increases whereas the efficiency decreases because of high surface temperatures. Using a photovoltaic-thermal system, the surface temperature can be decreased by capturing the excess heat and the efficiency can be increased due to these characteristics. In this paper, three cases are introduced : 1) PV_r as the reference case, 2) PVT_a, which uses air as a heat source, and 3) PVT_w, which uses water as a heat source. Experiments were performed, analyzed, and compared to examine the effect of the PVT type on the efficiency of the system. The results showed that ETC($%/^{\circ}C$) efficiency of the PVT cases was increased versus the reference case due to decreasing surface temperature. Total efficiencies, which are electrical efficiency and thermal efficiency, for each PVT are tested and found to be 12.22% for PV_r, 29.50% for PVT_a, and 68.74% for PVT_w.

Validity of the dietary reference intakes for determining energy requirements in older adults

  • Ndahimana, Didace;Go, Na-Young;Ishikawa-Takata, Kazuko;Park, Jonghoon;Kim, Eun-Kyung
    • Nutrition Research and Practice
    • /
    • v.13 no.3
    • /
    • pp.256-262
    • /
    • 2019
  • BACKGROUND/OBJECTIVES: The objectives of this study were to evaluate the accuracy of the Dietary Reference Intakes (DRI) for estimating the energy requirements of older adults, and to develop and validate new equations for predicting the energy requirements of this population group. MATERIALS/METHODS: The study subjects were 25 men and 23 women with a mean age of $72.2{\pm}3.9\;years$ and $70.0{\pm}3.3\;years$, and mean BMI of $24.0{\pm}2.1$ and $23.9{\pm}2.7$, respectively. The total energy expenditure (TEE) was measured by using the doubly labeled water (DLW) method, and used to validate the DRI predictive equations for estimated energy requirements (EER) and to develop new EER predictive equations. These developed equations were cross-validated by using the leave-one-out technique. RESULTS: In men, the DRI equation had a -7.2% bias and accurately predicted the EER (meaning EER values within ${\pm}10%$ of the measured TEE) for 64% of the subjects, whereas our developed equation had a bias of -0.1% and an accuracy rate of 84%. In women, the bias was -6.6% for the DRI equation and 0.2% for our developed equation, and the accuracy rate was 74% and 83%, respectively. The predicted EER was strongly correlated with the measured TEE, for both the DRI equations and our developed equations (Pearson's r = 0.915 and 0.908, respectively). CONCLUSIONS: The DRI equations provided an acceptable prediction of EER in older adults and these study results therefore support the use of these equations in this population group. Our developed equations had a better predictive accuracy than the DRI equations, but more studies need to be performed to assess the performance of these new equations when applied to an independent sample of older adults.

A Study of Critical Items and Related Standards on Designing for Passive Apartments (패시브 공동주택 계획을 위한 설계 중점항목 및 관련 기준 연구)

  • Lee, Myoung-Ju
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.7
    • /
    • pp.21-29
    • /
    • 2018
  • This study aimed to find and suggest the purpose of future plans, critical items on designing and Related standards to amend construction standards for domestic energy saving and environmentally friendly housings. It would also activate and increase the supplies of passive house minimizing the problems on current apartment housings in winter and reducing heating energy which brings fine dust pollution. After defining the standard model of Korean apartment housings(reference model), this study calculated the amount of heating energy demand per unit area annually as applying the yearly changed standards from 2008 to 2017 to existing standard model. It turned out that applying 2017 construction standards of energy saving and eco-friendly housings to reference model has saved up to 75% of heating energy demand comparing to the one applied 2008's. However, it still could not solve the fundamental problems such as winter fungus, condensation, freezing, freeze and burst, and insulation weakness space, and could not be free from fine dust particles. To solve them, this study suggested improved standards adding critical items on design related to outside insulation, cut off the heat-bridge, enforce air-tightness and heat change efficiency on heat recovery ventilator. As a result, it has reduced more than 10% of heat demand from 2017. It would be more than 90% of savings from 2008 if we make the amount of heat loss be zero on heat bridge on designing stage in the future.

A Prediction of Turbulent Characteristics in a Complex Terrain by Linear Theory (선형이론에 의한 복잡지형 내 난류 특성의 예측)

  • Yoon, J.E.;Kyong, N.H.;Kim, S.W.
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.79-86
    • /
    • 2005
  • The external conditions for estimating dynamic wind loads of wind turbines, such as the turbulence, the extreme wind, the mean velocity gradients and the flow angles, are simulated over GangWon Wind Energy Test Field placed in one of the most complex terrain in Korea. Reference meteorological data has been gathered at a height of 30m from 2003 to 2004 with a ultrasonic anemometer. The absolute value of the spectral energy are simulated and the verification of this prediction has been carried out with comparing to the experimental data. The most desirable place for constructing new wind turbine are resulted as Point 2 and Point 3 due to the lower value of Turbulence Intensity and the higher value of wind resource relatively.

Analysis on driving pattern of railway electric train for the energy efficiency (철도 전기차의 에너지효율화를 위한 패턴 분석)

  • Kim, Kang-Wheo;Han, Moon-Seob;Chang, Sang-Hoon;Jeong, Woo-Sung;Kang, Moon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1165_1166
    • /
    • 2009
  • In recent years, energy prices have soared, which of course have increased costs for railway operators. Simultaneously, the energy market has considerably changed that in most developed countries, it is deregulated, giving railway operators an opportunity to define new ways of using energy. Efficient operation of the railway system is considered as an essential way to energy saving while an efficient management of power level helps to lower the reference subscribed power, giving access to better energy rates. It is studied on the relation between time and force for the energy efficient driving of train in railway when the train is braking according to several slips.

  • PDF

A Study on the Validation Methodology of Network Analysis Applications in Energy Management Systems (계통운영시스템 계통해석 프로그램 검증 방안에 관한 연구)

  • Cho, Yoon-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.27-36
    • /
    • 2014
  • Network analysis applications in energy management systems play a key role in the economic and reliable operation of power systems. In order to provide operators with useful network information, the accurate results of topology processing, state estimation, power flow, and contingency analysis must be simulated. This paper proposes a validation methodology of network analysis applications in energy management systems. The energy management systems was checked to ensure that it meets the originally specified functions based on the proposed methodology. In addition, the performance of state estimation is evaluated with the reference of the proposed methodology. The proposed methodology is being conducted by energy management systems and the Korean power systems have been utilized for the test systems.