• Title/Summary/Keyword: reduction procedures

Search Result 577, Processing Time 0.03 seconds

Estimation of Gauge R&R by Variance Components of Measurement ANOVA (측정 ANOVA의 분산성분에 의한 게이지 R&R 추정)

  • Choi, Sung-woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.1
    • /
    • pp.199-205
    • /
    • 2010
  • The research proposes the three-factor random measurement models for estimating the precision about operator, part, tool, and various measurement environments. The combined model with crossed and nested factors is developed to analyze the approximate F test by degrees of freedom given by Satterthwaite and point estimation of precisions from expected mean square. The model developed in this paper can be extended to the three useful models according to the type of nested designs. The study also provides the three-step procedures to evaluate the measurement precisions using three indexes such as SNR(Signal-To-Noise Ratio), R&R TR(Reproducibility&Repeatability-To-Total Precision Ratio), and PTR(Precision-To-Tolerance Ratio), The procedures include the identification of resolution, the improvement of R&R reduction, and the evaluation of precision effect.

A Wrist-Type Fall Detector with Statistical Classifier for the Elderly Care

  • Park, Chan-Kyu;Kim, Jae-Hong;Sohn, Joo-Chan;Choi, Ho-Jin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.10
    • /
    • pp.1751-1768
    • /
    • 2011
  • Falls are one of the most concerned accidents for elderly people and often result in serious physical and psychological consequences. Many researchers have studied fall detection techniques in various domain, however none released to a commercial product satisfying user requirements. We present a systematic modeling and evaluating procedure for best classification performance and then do experiments for comparing the performance of six procedures to get a statistical classifier based wrist-type fall detector to prevent dangerous consequences from falls. Even though the wrist may be the most difficult measurement location on the body to discern a fall event, the proposed feature deduction process and fall classification procedures shows positive results by using data sets of fall and general activity as two classes.

Experimental validation of dynamic based damage locating indices in RC structures

  • Fayyadh, Moatasem M.;Razak, Hashim Abdul
    • Structural Engineering and Mechanics
    • /
    • v.84 no.2
    • /
    • pp.181-206
    • /
    • 2022
  • This paper presents experimental modal analysis and static load testing results to validate the accuracy of dynamic parameters-based damage locating indices in RC structures. The study investigates the accuracy of different dynamic-based damage locating indices compared to observed crack patterns from static load tests and how different damage levels and scenarios impact them. The damage locating indices based on mode shape curvature and mode shape fourth derivate in their original forms were found to show anomalies along the beam length and at the supports. The modified forms of these indices show higher sensitivity in locating single and multi-cracks at different damage scenarios. The proposed stiffness reduction index shows good sensitivity in detecting single and multi-cracks. The proposed anomalies elimination procedure helps to remove the anomalies along the beam length. Also, the adoption of the proposed weighting method averaging procedure and normalization procedure help to draw the overall crack pattern based on the adopted set of modes.

Reduction of Chronic Temporomandibular Joint Dislocation by Surgical Traction: Two Cases Report

  • Lim, Hye-Youn;Park, Sang-Jun;Jung, Tae-Young
    • Journal of Oral Medicine and Pain
    • /
    • v.42 no.2
    • /
    • pp.44-48
    • /
    • 2017
  • Chronic temporomandibular joint dislocation is defined as an acute dislocation that cannot be reduced or that recurs for more than one month. The management of dislocation depends on patient status and the duration of dislocation and ranges from conservative reduction to a surgical approach. In the present cases, a 64-year-old male was referred to our department for treatment of chronic dislocation for 6 weeks. The dislocation might be occurred by endotracheal intubation. A 70-year-old female was referred to our department with repeat right condyle dislocation after reduction of dislocation at a local clinic. When she visited for later treatment of new dentures, her condyle had been dislocated again for several weeks. In both cases, we tried to treat the dislocation with several manipulations, which were unsuccessful. Finally, chronic dislocation was successfully treated by surgical traction under general anesthesia without relapse. Surgical traction is a simple, effective option with the lowest morbidity of surgical procedures for chronic dislocation when conservative reduction is unsuccessful.

Treatment of Nasal Bone Fracture without Nasal Packing (비강 충전 없는 비골골절의 치료)

  • Lee, Dong Chan;Eun, Seok Chan;Heo, Chan Yeong;Baek, Rong Min;Minn, Kyung Won
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.1
    • /
    • pp.8-11
    • /
    • 2008
  • Purpose: The majority of nasal bone fractures have been managed by routine procedure of closed reduction, intranasal packing or intranasal Kirschner wire (K-wire) splinting. But it leaves rooms for many complaints from patients such as pain, rhinorrhea and nasal obstructioon. Another option is, of course, no packing at all. The study was initiated to assess the necessity to pack or splint the nasal bone after routine closed reduction. Methods: We analysed the medical records of 35 patients with nasal bone fracture who were operated by closed reduction in the last 2 years. We evaluated the postoperative CT scan scores and external deviation criterias 1 month after the operation. Results: The postoperative deviation criteria and postoperative CT scan score were favorable and there were no serious complications using this technique. Conclusion: The present study demonstrates that the use of packing or splinting need not be routine in the majority of cases. The risks and discomforts associated with these procedures can often be avoided.

The Effect of Half Day Nasal Packing in Results of Closed Reduction of Nasal Bone Fracture (반나절 비강충전이 비골 골절 수술결과에 미치는 영향)

  • Han, Dong Gil;Kim, Tae Seob
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.2
    • /
    • pp.119-124
    • /
    • 2012
  • Purpose: Closed reduction and nasal packings for 3-7 days is usual procedures in managing nasal bone fracture. Most patients experience several discomfort owing to lack of nasal breathing. There are many reports concerning how to reduce patient's discomforts or complications. But it is obvious that the duration of nasal packing is 3-7 days. The aim of this study is evaluate the effect of half day nasal packing in results of nasal bone fracture. Methods: The study was performed on 97 nasal bone fracture patients who had simple nasal bone fractures from January to June 2012. The incidence, cause, patient's discomfort and satisfaction with half day nasal packing are analyzed according to patient's medical records and questionnaire at each nasal packing removal, postoperative 4 weeks. Results: Young male patients, especially the teenagers and the twenties were the common age group, and physical violence was most common cause of injury. A total of 78 out of 97 patients were male. In 92 cases, closed reduction were applied. Approximately, 87% of the patients were satisfied with the outcomes. Conclusion: Half day nasal packing is considered as an effective method to minimize patient's discomfort owing to prolonged absence of nasal breathing with maintenance of stability.

Adaptive Noise Reduction Algorithm for Image Based on Block Approach (블럭 방법에 근거한 영상의 적응적 잡음제거 알고리즘)

  • Kim, Yeong-Hwa
    • Communications for Statistical Applications and Methods
    • /
    • v.19 no.2
    • /
    • pp.225-235
    • /
    • 2012
  • Noise reduction is an important issue in the field of image processing because image noise worsens the quality of the input image. The basic difficulty is that the noise and the signal are not easy to distinguish. Simple moothing is one of the most basic and important procedures to remove the noise, however, it does not consider the level of noise. This method effectively reduces the noise but the feature area is simultaneously blurred. This paper considers the block approach to detect noise and image features of the input image so that noise reduction could be adaptively applied. Simulation results show that the proposed algorithm improves the overall quality of the image by removing the noise according to the noise level.

Greenhouse Gas Emission Analysis by LNG Fuel Tank Size through Life Cycle

  • Park, Eunyoung;Choi, Jungho
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.393-402
    • /
    • 2021
  • As greenhouse gas emissions from maritime transport are increasing, the International Maritime Organization is continuously working to strengthen emission regulations. Liquefied natural gas (LNG) fuel is less advantageous as a point of CO2 reduction due to the methane leakage that occurs during the bunkering and operation of marine engines. In this study, greenhouse gas emissions from an LNG-fueled ship were analyzed from the perspective of the life cycle. The amount ofmethane emission during the bunkering and operation procedures with various boil-off gas (BOG) treatment methods and gas engine specifications was analyzed by dynamic simulation. The results were also compared with those of other liquid fuel engines. As a result, small LNG-fueled ships without a BOG treatment facility emitted 32% more greenhouse gas than ships utilizing marine gas oil or heavy fuel oil. To achieve a greenhouse gas reduction via a BOG treatment method, a gas combustion unit or re-liquefaction system must be mounted, which results in a greenhouse gas reduction effect of about 25% and 30%. As a result of comparing the amount of greenhouse gas generated according to the BOG treatment method used with each tank size from the perspective of the operating cycle with the amounts from using existing marine fuels, the BOG treatment method showed superior effects of greenhouse gas reduction.

Aeromonas hydrophila Infection following Leech Therapy for the Treatment of Nipple-Areola Complex Congestion after Breast Reduction: A Case Report

  • Matteo Torresetti;Benedetta Peltristo;Francesco Mauro Junior Taddei;Giovanni Di Benedetto
    • Archives of Plastic Surgery
    • /
    • v.51 no.3
    • /
    • pp.317-320
    • /
    • 2024
  • Several strategies for the management of venous congestion of the nipple-areola complex (NAC) after reduction mammaplasty have been proposed. Among these, hirudotherapy represents an ancient but still effective method, even though the risk of infections related to leeches should be considered. We report a peculiar case of breast infection and sepsis after leech therapy in a patient who underwent a reduction mammaplasty. A prompt surgical debridement of the wounds and necrotic tissues associated with targeted antibiotic therapy led to a fast improvement of clinical conditions, and partial preservation of the NAC was obtained. Accurate knowledge of the clinical presentation of soft tissue infections related to leeching allows for an early diagnosis and would serve as a warning for surgeons who approach such breast cosmetic procedures.

Measurement of Spatial Dose Distribution for evaluation operator dose during Neuro-interventional Procedures (두경부 질환의 인터벤션 시술 시 시술자의 피폭선량평가를 위한 공간선량측정에 관한 연구)

  • Han, Su-Chul;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.323-328
    • /
    • 2016
  • The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in $18.1{\pm}10.5%$, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.