• 제목/요약/키워드: reduction procedures

검색결과 565건 처리시간 0.027초

Some Recommended Procedures for Conversion of Carboxylic Acid and Its Derivatives to Aldehydes by Metal Hydride Reductions

  • Cha, Jin Soon
    • 통합자연과학논문집
    • /
    • 제5권2호
    • /
    • pp.84-90
    • /
    • 2012
  • Some recommended procedures for obtaining aldehydes from carboxylic acid itself and its derivatives, which have been developed in relatively recent years, are summarized. Such procedures should provide a new practical methodology to synthesize the desired aldehyde products in high yields.

Efficacy and Safety of Balloon Kyphoplasty in the Treatment of Osteoporotic Vertebral Body Compression Fractures : Compared with Vertebroplasty

  • Yi, Won-Jae;Lee, Jung-Ho;Lee, Hyuk-Gee;Ryu, Kee-Young;Kang, Dong-Gee;Kim, Sang-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권2호
    • /
    • pp.112-117
    • /
    • 2007
  • Objective : Kyphoplasty and vertebroplasty are two minimally invasive procedures for osteoporotic vertebral compression fractures. The purpose of this retrospective study was to compare the radiological findings and clinical outcomes between two procedures. Methods : Osteoporotic vertebral fractures were treated in 76 vertebrae, using kyphoplasty (n=35 vertebrae) and using vertebroplasty (n=41 vertebrae). Fractured vertebral bodies were diagnosed by correlating the clinical symptoms with radiologic study. The responses of pain symptoms were measured by a self-reported Visual Analog Scale (VAS) score. Plain X-rays were checked preoperatively and postoperatively at admission and 6 months. The vertebral body height and kyphotic angle were measured to assess the reduction of the sagittal alignment. Results : The mean pain scores were decreased significantly for both procedures postoperatively, but there were no significant differences between two groups. Kyphoplasty led to a significant reduction of the vertebral body height and improvement of kyphotic angle. There were no neurological deficits after kyphoplasty, but one patient experienced paraparesis after vertebroplasty. During the 6 months follow-up both procedures provided stabilization of the sagittal alignment. Conclusion : Kyphoplasty and vertebroplasty are considered effective minimally invasive techniques for the stabilization of osteoporotic vertebral body fractures, leading to a statistically significant reduction in pain. Kyphoplasty significantly restore sagittal alignment. Also, complications and the incidence of bone cement leakage are significantly lesser than vertebroplasty. Therefore, kyphoplasty seems to be reasonable procedure for osteoporotic vertebral body compression fractures when medical treatment fail.

The Efficacy of Simultaneous Breast Reconstruction and Contralateral Balancing Procedures in Reducing the Need for Second Stage Operations

  • Smith, Mark L.;Clarke-Pearson, Emily M.;Vornovitsky, Michael;Dayan, Joseph H.;Samson, William;Sultan, Mark R.
    • Archives of Plastic Surgery
    • /
    • 제41권5호
    • /
    • pp.535-541
    • /
    • 2014
  • Background Patients having unilateral breast reconstruction often require a second stage procedure on the contralateral breast to improve symmetry. In order to provide immediate symmetry and minimize the frequency and extent of secondary procedures, we began performing simultaneous contralateral balancing operations at the time of initial reconstruction. This study examines the indications, safety, and efficacy of this approach. Methods One-hundred and two consecutive breast reconstructions with simultaneous contralateral balancing procedures were identified. Data included patient age, body mass index (BMI), type of reconstruction and balancing procedure, specimen weight, transfusion requirement, complications and additional surgery under anesthesia. Unpaired t-tests were used to compare BMI, specimen weight and need for non-autologous transfusion. Results Average patient age was 48 years. The majority had autologous tissue-only reconstructions (94%) and the rest prosthesis-based reconstructions (6%). Balancing procedures included reduction mammoplasty (50%), mastopexy (49%), and augmentation mammoplasty (1%). Average BMI was 27 and average reduction specimen was 340 grams. Non-autologous blood transfusion rate was 9%. There was no relationship between BMI or reduction specimen weight and need for transfusion. We performed secondary surgery in 24% of the autologous group and 100% of the prosthesis group. Revision rate for symmetry was 13% in the autologous group and 17% in the prosthesis group. Conclusions Performing balancing at the time of breast reconstruction is safe and most effective in autologous reconstructions, where 87% did not require a second operation for symmetry.

영.유아의 배뇨성 방광-요도 조영술 및 방사선 공기 주입 정복술시 피폭선량 경감을 위한 fluorograb의 유용성 (The Efficacy of Fluorograb for Paediatric Patients Dose Reduction during Pneumatic Reduction and Voiding Cystourethrography(VCUG))

  • 김상태;최지원
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.385-390
    • /
    • 2009
  • 공기주입 정복술(pneumatic reduction) 및 방사선 배뇨성 방광요도 조영술(Voiding Cystourethrography: 이하 VCUG)는 일반적으로 영,유아에게서 행해지는데 이들 검사는 투시촬영과 spot 촬영으로 이루어지며 이때 투시촬영으로 인한 방사선 피폭은 불가피한 것이나 spot 촬영으로 인한 피폭은 투시 화면상의 관심영상을 capture하는 기능인 fluorograb을 이용하여 제거할 수 있다. fluorograb은 spot영상과 비슷한 진단가치를 지니고 있으며 최근 사용되고 있는 대부분의 투시촬영장비에서 지원되는 기능이지만 다수의 의사 및 방사선사는 이 기능을 인지하지 못하고 있거나 인지하고는 있으나 습관적으로 spot 촬영을 행하고 있는 실정이다. 이는 방사선에 매우 민감한 연령대에 속한 영.유아에서 적게는 10장 미만에서 많게는 20장 이상을 spot 촬영하게 되는 공기주입 정복술 및 VCUG에서 그 영향이 적지 않다 하겠다. 따라서 공기주입 정복술 및 VCUG 시행시 spot 촬영으로 인한 영.유아의 피폭을 줄이기 위한 방법으로 spot 촬영을 대신한 fluorograb을 제안하며 이로 인한 기존의 공기주입 정복술 및 VCUG 시행 시 영 유아의 피폭선량 경감 효과를 증명하고자 하였다. 공기주입 정복술 및 VCUG 의 진단에 fluorograb은 spot 촬영과 비슷한 수준의 정확도를 보이는 안전하고 유용한 방법이여 공기주입 정복술 및 VCUG 시행 시 spot 촬영을 대체할 수 있을 것으로 생각한다.

영아/유아의 공기 주입 정복술 및 방사선 배뇨성 방광요도 조영술시 피폭 선량 경감을 위한 FluroGrab의 유용성 (The Efficacy of Fluorograb for Paediatric Patients Dose Reduction during Pneumatic Reduction and Voiding Cystourethrography (VCUG))

  • 김상태;최지원;한태종
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.1167-1172
    • /
    • 2009
  • 공기주입 정복술(pneumatic reduction) 및 방사선 배뇨성방광요도 조영술(Voiding Cystourethrography: 이하 VCUG)는 일반적으로 영,유아에게서 행해지는데 이들 검사는 투시 촬영과 spot 촬영으로 이루어지며 이때 투시촬영으로 인한 방사선 피폭은 불가피한 것이나 spot 촬영으로 인한 피폭은 투시 화면상의 관심영상을 capture하는 기능인 fluorograb을 이용하여 제거할 수 있다. fluorograb은 spot영상과 비슷한 진단가치를 지니고 있으며 최근 사용되고 있는 대부분의 투시촬영장비에서 지원되는 기능이지만 다수의 의사 및 방사선사는 이 기능을 인지하지 못하고 있거나 인지하고는 있으나 습관적으로 spot 촬영을 행하고 있는 실정이다. 이는 방사선에 매우 민감한 연령대에 속한 영.유아에서 적게는 10장 미만에서 많게는 20장 이상을 spot 촬영하게 되는 공기주입 정복술 및 VCUG에서 그 영향이 적지 않다 하겠다. 따라서 공기주입 정복술 및 VCUG 시행시 spot 촬영으로 인한 영.유아의 피폭을 제거하기 위한 방법으로 spot 촬영을 대신한 fluorograb을 제안하며 이로 인한 기존의 공기주입 정복술 및 VCUG 시행시 영.유아의 피폭선량 경감 효과를 증명하고자 하였다. 공기주입 정복술 및 VCUG 의 진단에 fluorograb은 spot 촬영과 비슷한 수준의 정확도를 보이는 안전하고 유용한 방법이여 공기주입 정복술 및 VCUG 시행시 spot 촬영을 대체할 수 있을 것으로 생각한다.

  • PDF

Impact of the Coronavirus Disease 2019 Pandemic on Pediatric Gastrointestinal Endoscopy: A Questionnaire-based Internet Survey of 162 Institutional Experiences in Asia Pacific

  • Andy Darma;Katsuhiro Arai;Jia-feng Wu;Nuthapong Ukarapol;Shin-ichiro Hagiwara;Seak Hee Oh;Suporn Treepongkaruna;Endoscopy Subcommittee of the Scientific Committee Asian Pan-Pacific Society of Pediatric Gastroenterology and Hepatology and Nutrition (APPSPGHAN)
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제26권6호
    • /
    • pp.291-300
    • /
    • 2023
  • Purpose: The impact of coronavirus 2019 (COVID-19) on gastrointestinal (GI) endoscopy procedures in adults has been reported, with a drastic reduction in the number of procedures. However, there are no sufficient data regarding the impact on pediatric GI endoscopy. Here, we aimed to report that impact in the Asia-Pacific region. Methods: A questionnaire-based internet survey was conducted from June to November 2021 among pediatric endoscopy institutions in the Asia-Pacific region, with each institution providing a single response. Overall, 25 questions focused on the impact of the number of procedures conducted, the usage of personal protective equipment (PPE), and endoscopy training programs during the pandemic. Results: A total of 162 institutions across 13 countries in the Asia-Pacific region participated in the study, and 133 (82.1%) institutions underwent procedure changes since the emergence of COVID-19. The number of esophagogastroduodenoscopy and ileocolonoscopy procedures decreased in 118/133 (88.7%) and 112/133 (84.2%) institutions, respectively. Endoscopy for patient with positive COVID-19 in an emergency or urgent cases still carried out in 102/162 (62.9%) institutions. Screening of COVID-19 for all patients before endoscopy was done across 110/162 (67.9%) institutions. PPE recommendations varied among institutions. Pediatric gastrointestinal endoscopy training programs were discontinued in 127/162 (78.4%) institutions. Conclusion: This study reports the impact of the COVID-19 pandemic on pediatric gastrointestinal endoscopy in the Asia-Pacific region. There has been a significant reduction in the number of endoscopic procedures and relevant training programs.

사내 공급자와 연계된 재해경감활동관리체계 구축방법 개선 연구 (Research on Improving the Method of Establishing a Disaster Reduction Activity Management System linked with In-house Suppliers)

  • 김상덕;김창수
    • 한국재난정보학회 논문집
    • /
    • 제17권2호
    • /
    • pp.365-374
    • /
    • 2021
  • 연구목적: 본 연구는 발주기관과 사내 공급자의 재해경감활동관리체계 연계성 강화에 대하여 연구하고자 한다. 연구방법: 기업재난관리표준에 정하고 있는 공급자 전략에 대한 요구사항을 파악하고, A기관과 공급자B의 적용사례를 검토 분석하여 재해경감활동관리체계의 연계성 강화를 위한 절차를 도출하였다. 연구결과: 기업재난관리표준의 요구사항인 공급자 전략에 대하여 명확히 정의하고, 연계성 강화를 위해서 발주기관과 공급자가 적용하는 절차와 그 절차에 의하여 산출된 결과물을 공유하는 표준화된 절차가 필요한 것으로 연구되었다. 결론: 사내에 상주하는 공급자의 재해경감활동관리체계 수립 절차중 중요한 절차의 연계성 강화를 위한 개선안을 제안하였으며, 제안된 내용과 절차를 기업재난관리표준과 관련 규범에 반영할 것을 제시하였다.

The Role of Bone Cement Augmentation in the Treatment of Chronic Symptomatic Osteoporotic Compression Fracture

  • Kim, Hyeun-Sung;Kim, Sung-Hoon;Ju, Chang-Il;Kim, Seok-Won;Lee, Sung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권6호
    • /
    • pp.490-495
    • /
    • 2010
  • Objective : Bone cement augmentation procedures such as percutaneous vertebroplasty and balloon kyphoplasty have been shown to be effective treatment for acute or subacute osteoporotic vertebral compression fractures. The purpose of this study was to determine the efficacy of bone cement augmentation procedures for long standing osteoporotic vertebral compression fracture with late vertebral collapse and persistent back pain. Methods : Among 278 single level osteoporotic vertebral compression fractures that were treated by vertebral augmentation procedures at our institute, 18 consecutive patients were included in this study. Study inclusion was limited to initially, minimal compression fractures, but showing a poor prognosis due to late vertebral collapse, intravertebral vacuum clefts and continuous back pain despite conservative treatment for more than one year. The subjects included three men and 15 women. The mean age was 70.7 with a range from 64 to 85 years of age. After postural reduction for two days, bone cement augmentation procedures following intraoperative pressure reduction were performed. Imaging and clinical findings, including the level of the vertebra involved, vertebral height restoration, injected cement volume, local kyphosis, clinical outcome and complications were analyzed. Results : The mean follow-up period after bone cement augmentation procedures was 14.3 months (range 12-27 months). The mean injected cement volume was 4.1 mL (range 2.4-5.9 mL). The unipedicular approach was possible in 15 patients. The mean pain score (visual analogue scale) prior to surgery was 7.1, which decreased to 3.1 at 7 days after the procedure. The pain relief was maintained at the final follow up. The kyphotic angle improved significantly from $21.2{\pm}4.9^{\circ}$ before surgery to $10.4{\pm}3.8^{\circ}$ after surgery. The fraction of vertebral height increased from 30% to 60% after bone cement augmentation, and the restored vertebral height was maintained at the final follow up. There were no serious complications related to cement leakage. Conclusion : In the management of even long-standing osteoporotic vertebral compression fracture for over one year, bone cement augmentation procedures following postural reduction were considered safe and effective treatment in cases of non-healing evidence.

Effects of various prophylactic procedures on titanium surfaces and biofilm formation

  • Di Salle, Anna;Spagnuolo, Gianrico;Conte, Raffaele;Procino, Alfredo;Peluso, Gianfranco;Rengo, Carlo
    • Journal of Periodontal and Implant Science
    • /
    • 제48권6호
    • /
    • pp.373-382
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the effects of various prophylactic treatments of titanium implants on bacterial biofilm formation, correlating surface modifications with the biofilms produced by Pseudomonas aeruginosa PAO1, Staphylococcus aureus, and bacteria isolated from saliva. Methods: Pure titanium disks were treated with various prophylactic procedures, and atomic force microscopy (AFM) was used to determine the degree to which surface roughness was modified. To evaluate antibiofilm activity, we used P. aeruginosa PAO1, S. aureus, and saliva-isolated Streptococcus spp., Bacteroides fragilis, and Staphylococcus epidermidis. Results: AFM showed that the surface roughness increased after using the air-polishing device and ultrasonic scaler, while a significant reduction was observed after using a curette or polishing with Detartrine ZTM (DZ) abrasive paste. In addition, we only observed a significant (P<0.01) reduction in biofilm formation on the DZ-treated implant surfaces. Conclusion: In this study, both AFM and antibiofilm analyses indicated that using DZ abrasive paste could be considered as the prophylactic procedure of choice for managing peri-implant lesions and for therapy-resistant cases of periodontitis.

A Differential Data Replicator in Distributed Environments

  • Lee, Wookey;Park, Jooseok;Sukho Kang
    • 정보기술과데이타베이스저널
    • /
    • 제3권2호
    • /
    • pp.3-24
    • /
    • 1996
  • In this paper a data replicator scheme with a distributed join architecture is suggested with its cost functions and the performance results. The contribution of this scheme is not only minimizing the number of base relation locks in distributed database tables but also reducing the remote transmission amount remarkably, which will be able to embellish the distributed databse system practical. The differential files that are derived from the active log of the DBMS are mainly forcing the scheme to reduce the number of base relation locks. The amount of transportation between relevant sites could be curtailed by the tuple reduction procedures. Then we prescribe an algorithm of data replicator with its cost function and show the performance results compared with the semi-join scheme in their distributed environments.

  • PDF