Development of a Fault Diagnosis Algorithm on a High Current Cable of Arc Furnace (전기로 대전류 케이블 고장진단 알고리즘 개발)

  • Kim, Sang-Woo;Jang, Yu-Jin
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.3
    • /
    • pp.115-118
    • /
    • 2006
  • In the steel industry, a steel melting electric arc furnace is used to produce both carbon and alloy steels. Steel scrap which is charged into the furnace is heated by means of electric arc between graphite electrodes and the scrap. In this melting process, current is supplied to the furnace through HCC(high current cable) which connect the furnace and transformer. Four HCCs are assigned to each phase in our system to divide the current. Since a sudden cable breaking result in the shutdown of melting process, an aging detection of HCC is very important for both an improvement of productivity and cost reduction. In this paper, the aging of the HCC is estimated by using the current ratio between four HCCs.

Determination of BTB HVDC Operating Point in Metropolitan area (대도시 내 BTB HVDC 투입 시 운전점 결정 방안)

  • Lee, Jae Hyeong;Yoon, Minhan;Han, Changhee;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.331-332
    • /
    • 2015
  • Since $20^{th}$ century, along with the rapid industrial advancement, the concentrated urban development in specific large cities have made people migrate to those cities, thus causing problems in the power system stability. In case of Korea, more than 40% of the power system demand comes from the consumers in Seoul Metropolitan area and the rate is expected to increase. With the continuous increase of power demand, in order to meet the demand for system reliability improvement, the power system was multi-looped for reliability enhancement, the problem of fault current happened. In this situation, there are several methods for fault current reduction likes current limiting reactor, replacing circuit breaker, splitting busses, etc. But these methods reached its limit, power system needs more fundamental solutions such as grid segmentation. In this paper, we assume grid segmentation already has been progressed using VSC BTB HVDC. Then, this paper discusses operating point of HVDC in metropolitan area considering loss minimization and handy flow control. The simulation is proceeded on 2027 KEPCO system.

  • PDF

Inspection of General Use Electric Installation Using Leakage Current Measuring (누설전류측정을 이용한 일반용전기설비의 점검)

  • Lim, Young-Bae;Jung, Jong-Wook;Jung, Jin-Soo;Bae, Seok-Myung;Cho, Seong-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.63-65
    • /
    • 2006
  • A electrical fault is defined as any abnormal condition caused by a reduction in the insulation strength. To define the potential risk of the electric installation, measurement of leakage current has been getting considered, but because the measured leakage current value also contained leakage current by capacitance, the measured value could not be adapted to absolute reference to the installation. Therefore, in this paper, the correlation between the condition of electric installation and leakage current were analyzed. The result focuses on to detect them in a cost efficient way.

  • PDF

Transient Overloads Control Mechanism for Virtual Memory System (가상 메모리 시스템의 일시적인 과부하 완화 기법)

  • Go, Young-Woong;Lee, Jae-Yong;Hong, Cheol-Ho;Yu, Hyukc
    • The KIPS Transactions:PartA
    • /
    • v.8A no.4
    • /
    • pp.319-330
    • /
    • 2001
  • In virtual memory system, when a process attempts to access a page that is not resident in memory, the system generates and handles a page fault that causes unpredictable delay. So virtual memory system is not appropriate for the real-time system, because it can increase the deadline miss ratio of real-time task. In multimedia system, virtual memory system may degrade the QoS(quality of service) of multimedia application. Furthermore, in general-purpose operating system, whenever a new task is dynamically loaded, virtual memory system suffers from extensive page fault that cause transient overloading state. In this paper, we present efficient overloading control mechanism called RBPFH (Rate-Based Page Fault Handling). A significant feature of the RBPFH algorithm is page fault dispersion that keeps page fault ratio from exceeding available bound by monitoring current system resources. Furthermore, whenever the amount of available system resource is changed, the RBPFH algorithm dynamically adjusts the page fault handling rate. The RBPFH algorithm is implemented in the Linux operating system and its performance measured. The results demonstrate RBPFH\`s superior performance in supporting multimedia applications. Experiment result shows that RBPFH could achieve 10%∼20% reduction in deadline miss ratio and 50%∼60% reduction in average delay.

  • PDF

Performance Analysis of Hybrid Type HVDC Circuit Breakers in Voltage Source Converter based HVDC System (전압형 HVDC 시스템 적용을 고려한 Hybrid Type HVDC 차단기의 동작 특성 분석)

  • Khan, Umer Amir;Lee, Jong-Gun;Lim, Sung-Woo;Lee, Ho-Yun;Lee, Bang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.153-154
    • /
    • 2015
  • Voltage Source Converter HVDC (VSC-HVDC) are a better alternative than conventional thyristor based HVDC systems. Unfortunately, VSC-HVDC's full potential cannot be utilized up till now due to absence of suitable HVDC protection. Recently, hybrid HVDC circuit breakers (HDCCB) have been developed and successfully lab tested. However, their application and feasibility in VSC-HVDC needs to be investigated. In this research paper we have modelled an existing HDCCB and evaluated its impact on fault reduction and interruption in VSC-HVDC systems. The HDCCB was applied in Korean Jeju-Haenam VSC-HVDC system model and its impact was analyzed for HVDC line-to-ground and line-to-line faults. HDCCB successfully interrupted the fault current and prevented the damages to costly IGBTs and converter transformers.

  • PDF

A Plan to Ensure Safety of Electrical Installation in Empty Houses by Measuring Zero Phase Current (영상전류 측정을 이용한 부재수용가의 전기설비에 대한 안전확보 방안)

  • Lim, Young-Bae;Bae, Seok-Myung;Kim, Young-Seok;Park, Chee-Huyn;Kim, Gi-Hyun;Cho, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.196-201
    • /
    • 2006
  • A electrical fault that may generate an electrical disaster is defined as any abnormal condition caused by reduction in the insulation strength. To find out the abnormal condition, periodical inspections have being performed every 3 years. Recently, the number of empty houses during normal working hours is rising by dramatic increase in the number of nuclear families and double income families. To define the potential risk of the electric installation, measurement of zero phase current has been being considered. But the measured value could not be adapted to an absolute reference to the installation because the measured zero phase current value also contained capacitive leakage current. Therefore, in this paper, the correlation between the condition of the electrical installation and the zero phase current was analyzed. The result focuses on to detect them in a cost efficient way.

A Study on Service Restoration Guide by Network Reduction in Distribution Systems (배전계통에서의 계통 축약에 의한 정전 복구방안 수립에 관한 연구)

  • Kim, S.H.;Choi, B.Y.;Lee, S.M.;Cho, S.H.;Lee, J.K.;Moon, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.500-502
    • /
    • 1995
  • Whenever faults(a fault) occur(s) in a particular section of a distribution system, some of loads get disconnected and are left unsupplied. Service should be restored to these affected load points as quickly as possible through network reconfiguration. An efficient technique is presented in this paper for this purpose. Network reduction and strategy testing the voltage and current constraints are the main contributions of this paper.

  • PDF

A Test Input Sequence for Test Time Reduction of $I_{DDQ}$ Testing

  • Ohnishi, Takahiro;Yotsuyanagi, Hiroyuki;Hashizume, Masaki;Tamesada, Takeomi
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.367-370
    • /
    • 2000
  • It is shown that $I_{DDQ}$ testing is very useful for shipping fault-free CMOS ICs. However, test time of $I_{DDQ}$ testing is extremely larger than one of logic testing. In this paper, a new test input sequence generation methodology is proposed to reduce the test time of $I_{DDQ}$ testing. At first, it is Shown that $I_{DDQ}$ test time Will be denominated by charge supply current for load capacitance of gates whose output logic values are changed by test input vector application and the charge current depends on input sequence of test vectors. After that, a test input sequence generation methodology is proposed. The feasibility is checked by some experiments.riments.

  • PDF

Performance Improvement of Protective Relaying for Large Transformer by Using Voltage-Current Trend and Flux-Differential Current Slope Characteristic (전압-전류 추이와 자속-차전류 기울기 특성을 이용한 변압기 보호계전기법의 성능 개선)

  • Park, Chul-Won;Park, Jae-Sae;Jung, Yun-Man;Ha, Kyung-Jae;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.43-50
    • /
    • 2004
  • Percentage differential characteristic relaying(PDR) has been recognized as the principal basis for power transformer protection. Second harmonic restraint PDR has been widely used for magnetizing inrush in practice. Nowadays, relaying signals can contain 2nd harmonic component to a large extent even in a normal state, and 2nd harmonic ratio indicates a tendency of relative reduction because of the advancement of material. Further, as the power system voltage becomes higher and more underground cables are used, larger 2nd harmonic component in the differential current under internal fault is observed. And then, conventional 2nd harmonic restraint PDR exposes some doubt in reliability. It is, therefore, necessary to develop a new algorithm for performance improvement of conventional protective relaying. This paper proposes an advanced protective relaying algorithm by using voltage-current trend and flux-differential current slope characteristic. To evaluate the performance of the proposed algorithm, we have made comparative studies of PDR, fuzzy relaying and DWT relaying. The paper is constructed power system model including power transformer, utilizing the WatATP, and data collection is made through simulation of various internal faults and inrush. As the results of test, the new proposed algorithm was proven to be faster and more reliable.

Models of Social Relief Schemes for Medical Malpractice (의료사고피해 구제제도의 제 모형)

  • 문옥륜;이기효
    • Health Policy and Management
    • /
    • v.2 no.1
    • /
    • pp.80-114
    • /
    • 1992
  • Current compensation schemes for medical malpractice based on negligence is absolutely malfunctioning in Korea. Focussing on the reform of present tort systems for resolving medical malpractice disputes, this paper discusses the alternative models of the Social Relief Schemes for Medical Malpractice (SRSMM). Alternative models of SRSMM should fundamentally be based on either negligence or nofalult compensation principle. On the foundation of the previous relief principle, the SRSMM should be equupped with three major components-the preventio/reduction of the sharp increasing medical malpractice, the effective and efficient resolving process for malpractice disputes and the proper social financing scheme for compensation. The paper deals with pros and cons of the possible alternative models for reform centering on the three major components of the scheme. As conclusions, administrative arbitration machinaries and a compulsory fund for compensating the injured under the negligence principle are proposed to resolve the current problems Korea has faced.