• Title/Summary/Keyword: reduction agent

Search Result 1,054, Processing Time 0.026 seconds

An Experimental Study on the Properties Analysis of Concrete Using Bleeding Reduction Agent (블리딩 저감제를 사용한 콘크리트의 성능분석에 관한 실험적 연구)

  • 전충근;김경민;황인성;신병철;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.669-674
    • /
    • 2002
  • This paper describes the properties analysis of concrete using bleeding reduction agent. According to the results, the fluidity and the air content of fresh concrete with increase of bleeding reduction agent show little difference in compare with plain concrete which does not use bleeding reduction agent. The efficiency of bleeding reduction agent is confirmed because in variation of W/C and slump, the increase of bleeding reduction agent dosage reduces bleeding remarkably. And the compressive strength of hardened concrete does not show any differences with increase the dosage of bleeding reduction agent. Bleeding reduction agent does not have bad effect on the quality of concrete such as fluidity, air content and the strength of hardened concrete and so on, the dosage of it can reduce bleeding effectively.

  • PDF

Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for Reduction of Bleeding (블리딩저감용 AE감수제를 사용한 콘크리트의 블리딩 저감 특성)

  • Kim, Ki-Hoon;Hwang, Yin-Seong;La, Woon;Im, Ju Hyeuk;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.69-72
    • /
    • 2003
  • This study is intended to investigate the fundamental properties of concrete which AE water reducing agent for reduction of bleeding is used, and the properties of bleeding reduction. According to the results, when the adding ratio of AE water reducing agent for reduction of bleeding increases, a range of normal fluidity and aimed air content arc satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 60 min. When, AE water reducing agent for reduction of bleeding is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for reduction of bleeding. Synthetically, it proves that AE water reducing agent for reduction of bleeding satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

  • PDF

Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for Reduction of Bleeding (블리딩저감용 AE감수제를 사용한 콘크리트의 블리딩 저감 특성)

  • Kim, Ki-Hoon;Hwang, Yin-Seong;La, Woon;Im, Ju-Hyeuk;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.69-72
    • /
    • 2003
  • This study is intended to investigate the fundamental properties of concrete which AE water reducing agent for reduction of bleeding is used, and the properties of bleeding reduction. According to the results, when the adding ratio of AE water reducing agent for reduction of bleeding increases, a range of normal fluidity and aimed air content are satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 60 min. When. AE water reducing agent for reduction of bleeding is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for reduction of bleeding. Synthetically, it proves that AE water reducing agent for reduction of bleeding satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

  • PDF

Engineering Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for the Type of Bleeding Reduction (블리딩저감형 AE감수제를 사용한 콘크리트의 공학적 특성)

  • Han, Cheon-Goo;Hwang, Yin-Seong;Lee, Seung-Hoon;Kim, Gyu-Dong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.133-140
    • /
    • 2004
  • This study is intended to investigate the properties of bleeding reduction of concrete using AE water reducing agent for the type of bleeding reduction with the replacement admixture. According to the results, when the adding ratio of AE water reducing agent for the type of bleeding reduction increases, a range of normal fluidity and aimed air content are satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 50 min. When AE oater reducing agent for the type of bleeding reduction is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for the type of bleeding reduction. Synthetically, it proves that AE water reducing agent for the type of bleeding reduction satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

An Experimental Study on the Development of Soft Ground Firming Agent Using EAF Reduction Slag (전기로 환원 슬래그를 이용한 연약지반 고화재 개발에 관한 실험적 연구)

  • Lee, Kang-Seok;Lee, Yoon-Kyu;Choi, Jae-Seok;Han, Man-Hae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.998-1001
    • /
    • 2010
  • Most firming agent used in Korea is cement-firming agent. Cement-firming agent absorb water for combination, and then it makes ettringite. Through this chemical process, soft ground is firmed by cement-firming agent. Although most cement-firming agent used in Korea made from CSA, it relies on imports. Therefore, the development of soft ground firming agent using new materials is required. In this study, we suggested that EAF reduction slag not used for anything in the steel industry is available for material of soft ground firming agent. If EAF reduction slag is used in soft ground firming agent, it will be possible to solve the problem with treatment of slag and improvement of soft ground.

  • PDF

A Study on the Physical Characteristics of Concrete using Multi-Component Blended Binder According to Warter Reduction Efficiency of Warter Reduction Agent (감수제의 감수 효율에 따른 다성분계 결합재를 사용한 콘크리트의 물리적 특성에 관한 기초적 연구)

  • Kim, Kyung-Hwan;Oh, Sung-Rok;Choi, Byung-Keol;Choi, Yun-Wang
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.5
    • /
    • pp.559-568
    • /
    • 2015
  • In this study, multi-component blended concrete mix with fly ash and ground granulated blast furnace slag according to 3 level of type of warter reduction agent (type of 0%, 8% and 16%) and 3 level of water-binder ratio (40%, 45% and 50%) was prepared for evaluation of effect of physical characteristics of concrete using multi-component blended binder according to warter reduction efficiency of warter reduction agent. In addition, concrete mix was carried out repetition test of three times in order to secure the reliability. As a result, compressive strength according to type of warter reduction agent was found that difference of strength was about 20% occurred, warter reduction efficiency of warter reduction agent was showed that a great influence on qualities of concrete. Therefore, reflected the effect of warter reduction efficiency of warter reduction agent, prediction model equations of compressive strength for multi-component blended concrete was proposed, it was found that more than 90% of the high correlation.

Development and Analysing the Practical Use of Bleeding Reduction Agent for Concrete (콘크리트용 블리딩저감제의 개발 및 실용성 검토)

  • Han, Cheon-Goo;Hwang, Yin-Seong;Shin, Dong-In
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.217-224
    • /
    • 2003
  • It is necessary to reduce bleeding, which is a kind of segregation of fresh concrete, for improvement of quality of concrete structure. But, besides using high qualify material and adjusting mixture ratio, there is no easy solution to reduce bleeding by now. For that reason, this study is intended to develop bleeding reduction agent and to investigate its application. The test results are following. At first, recommended mixture ratio of bleeding reduction agent is proven to be MC viscosity agent : defoaming agent : superplasticyzer of 1 : 0.004 : 0.2. It goes to prove that bleeding reduction agent does not have bad effect on the quality of concrete such as fluidity, air content and the strength of hardened concrete etc, and can reduce bleeding effectively. Therefore it is thought that bleeding reduction agent can be applied to construction field effectively.

A Study on Radon Emission Reduction of Construction Materials using Radon-reducing Agent (라돈 저감제를 이용한 건축자재의 라돈 방출 저감 연구)

  • Park, Kyung-Buk;Lee, Sang-Houck
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.6
    • /
    • pp.484-491
    • /
    • 2014
  • Objectives: A radon emission reducing agent was prepared using charcoal and zeolite, and the amount was measured after coating construction materials with the agent. The availability of the radon emission reducing agent was evaluated. Methods: Construction materials (red brick, cement brick, and gypsum board) coated with reducing agent were placed in a chamber to measure radon emissions. The construction materials were coated one through three times. The spread volume for brick and gypsum board was 50 mL and 75 mL per application, respectively. The amount of radon emitted was measured by RAD-7 after 48 hours. Results: The reduction ratio increased with the number of coatings, and the reduction ratios for red brick, cement brick, and gypsum board were 63.3, 73.6, and 58%, respectively, in the case of three coatings of RA-1. The reduction ratios for red brick, cement brick, and gypsum board were 42.8, 58.1, and 26.2%, respectively in the case of three coatings with RA-2. RA-1 was slightly better than RA-2 in radon emission reduction. Conclusions: Radon emissions from construction materials decreased according to the concentration of reducing agent coating, and it was more effective than existing methods.

A Fundamental Study on the Development of AE Water Reducing Agent for Reduction of Bleeding (블리딩 저감용 AE감수제 개발에 관한 기초적 연구)

  • 문학용;김한준;김규용;신동인;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.75-78
    • /
    • 2003
  • This study is to investigate the probability to develop the AE Water-reducing agent which can decrease the bleeding by mixing melamine type super-plasticizer(SP) and methyl cellulose(MC) viscosity agent. According to the result, as the mixing ratio of melamine type SP and MC viscosity agent increases, the bleeding is reduced due to a increase of the air content. When the mixing ratio of melamine type SP and MC viscosity agent is 1:2 and 1;3 at the water content of 165kg/$m^3$ and 175kg/$m^3$ respectively, slump and air content are satisfied and bleeding is reduced to some extent, so this is determined as the mixing ratio of AE water reducing agent for reduction of bleeding. It is prove that the developed AE water reducing agent for reduction of bleeding can reduce the amount of bleeding and prohibit the plastic shrinkage crack by slowing down the bleeding speed. Compressive strength of hardened concrete does not make any difference in comparison with plain concrete.

  • PDF

Effects of Blowing and Nucleating Agents on the Foaming Properties of Nylon 6

  • Jung-soo Kim;Sung Yeol Kim
    • Elastomers and Composites
    • /
    • v.58 no.2
    • /
    • pp.65-69
    • /
    • 2023
  • To reduce the weight of the engineering plastic Nylon 6 resin, two high-temperature foaming agents, p-toluenesulfonyl semicarbazide (PTSS) and 5-phenyltetrazole (5-PT) (0-10 phr), were added and foamed without other additives. We investigated the effects of the foaming agent type and content on the foam density (g/cm3) and percent weight reduction rate of the Nylon 6 foam, and 5-PT exhibited better foaming performance than PTSS. In the case of 5-PT, the weight reduction rate was above 36% when the blowing agent content was 1.5 phr or higher, indicating that 5-PT is an effective blowing agent for reducing the Nylon 6 foam weight. Additionally, we studied the effect of the nucleating agent Talc content (0-0.4 phr) on Nylon 6 foaming, and the nucleating agent Talc considerably reduced foaming.