• 제목/요약/키워드: reducing radiation of exposure

검색결과 144건 처리시간 0.027초

흉부 왼쪽 엑스선검사 시 위치 잡기의 중요성 (The Importance of Positioning in Left Lateral Chest X-Ray Examination)

  • 조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권4호
    • /
    • pp.287-294
    • /
    • 2023
  • This study was conducted to ultimately reduce unnecessary radiation exposure by emphasizing the need and importance of correct positioning by examining the positioning relationship of anatomical structures in the human body and changes in X-ray images according to changes in patient positioning during the left lateral chest X-ray examination. This study investigated and analyzed previously published papers and books on the left lateral chest X-ray examination to find out the importance of positioning in the left lateral chest X-ray examination. To find out the importance of correct positioning in the left lateral chest X-ray, we compared three images of incorrectly positioned right thorax and left thorax rotated forward and the lower median surface of the body leaning against the image receptor. In the left lateral chest examination, a distorted image was obtained in which the shape of the anatomical structure observed in the image was changed according to the presence or absence of rotation of the patient and the inclination of the median visual surface. X-ray images with the most accurate and large amount of information were obtained from X-ray images with the correct positioning performed during left lateral chest X-ray examination. Therefore, It is believed that the left lateral chest X-ray examination will have beneficial effects such as providing accurate medical information, preventing misdiagnosis, reducing social costs, and ultimately reducing radiation exposure.

유방촬영 시 갑상샘의 피폭선량 경감을 위한 Al Face Block 제작 및 유용성에 관한 연구 (The Usefulness of Al Face Block Fabrication for Reducing Exposure Dose of Thyroid Glands in Mammography)

  • 홍은애;이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권1호
    • /
    • pp.11-17
    • /
    • 2013
  • 최근 환자가 안심하고 진료를 받을 수 있도록 의료 환경의 변화에 따라 의료 피폭 저감화 대책이 국내, 국제적으로 추진되고 있다. 연구자는 유방촬영 시 보다 안전하게 검사를 받을 수 있도록 환자의 방사선 피폭에 대한 방어 및 안전 관리가 절실 하다고 생각되어 본 차폐체를 개발하고, 제작하게 되었다. 임상에서 사용 중인 유방촬영 장치로 SID 65 cm, 조건 28 kVp, 63 mAs, 측정기는 Victoreen 6000-529(Fluke Co.)를 이용하여 제작한 Face Block을 사용하여, 환자 30명을 대상으로 실제 갑상샘 위치에 Chamber를 놓고 CC, MLO를 촬영해 Face Block장착 전, 후 선량을 측정하였다. 그 결과 Face Block 장착 후 CC View에서 평균 65.9%의 선량이 감소되었고, MLO View에서는 평균 60.7%의 선량이 감소되었으며, 영상의 질에는 큰 변화가 없었다. 따라서 유방촬영 시 갑상샘의 피폭을 줄이고, 실용적이고, 유용한 실제 Face Block을 개발한 것에 큰 성과가 있었다고 생각되며, 유방촬영 시 환자들의 피폭에 관한 불안감을 해소시켜, 환자 만족도 증대와 함께 환자 피폭선량 경감에 크게 이바지 할 것으로 기대하며, 피폭선량을 줄일 수 있는 방안을 끊임없이 노력해야 할 것이다.

흉부 및 복부에서 AEC 적용에 따른 MDCT의 선량 감소 효과 (Radiation Dose Reducing Effect during the AEC System in the Chest and Abdomen of the MDCT Scanning)

  • 이종석;권대철;유병규
    • 한국콘텐츠학회논문지
    • /
    • 제9권3호
    • /
    • pp.225-231
    • /
    • 2009
  • CT검사에 따른 방사선 선량의 유해성에 대한 관심이 고조되고 있어, 고정관전류기법과 AEC(automatic exposure control)를 적용하여 선량의 감소 효과를 비교하였다. 64MDCT를 이용하여 인체조직등가물질 팬텀으로 흉부 및 복부 부위를 고정관전류기법과 AEC를 적용하여 CTDIvol과 DLP를 비교하였고, 영상의 평가는 관심영역으로 CT감약계수와 노이즈를 측정하여 비교하였다. 흉부에서 고정관전류기법과 AEC적용에 따른 선량감소 효과는 CTDIvol 35.2%, DLP 49.3%, 복부에서는 CTDIvol 5.9%, DLP 3.2% 감소 효과가 있었다. CT검사에서 자동노출장치인 AEC를 이용하여 선량의 감소효과가 있다. CT 검사에 따른 환자의 피폭선량을 줄이기 위해서는 AEC를 이용하여야 한다.

두부규격방사선촬영장치의 두경부 피폭 저감에 대한 연구 (Study on Research for Reducing Radiation Dose of Head and Neck for Cephalometric Radiography System)

  • 오윤진;신재원;이삼열
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.291-298
    • /
    • 2016
  • 최근 국민의 소득수준 증가에 따른 소아의 교정치료 등의 관심이 커지면서 치과방사선 검사의 건수가 증가하고 있어 부정교합 및 악골과 치아의 위치변화 등을 관찰할 수 있는 두부규격방사선촬영이 빈번해지고 있다. 특히 검사 대상자가 방사선에 더욱 민감한 소아 층에 집중되어 있고 촬영 부위인 두경부에는 갑상선, 골수, 안구, 타액선 등의 방사선에 민감한 주요 장기가 위치하고 있어 피폭의 주의가 요구된다. 이에 따라 본 연구에서는 Agfa CP-G Plus 필름과 MagicMax 선량계를 이용하여 두경부규격방사선촬영장치(VATEC Pax-400C)에서 발생되는 X선의 2차원 선량분포를 측정하고 MCNPX 시뮬레이션을 통해 두경부 장기선량을 계산하였으며 피폭저감 장치를 설계하였다. 두부규격방사선촬영의 선량분포는 구강악안면의 검사 목적 부위 이외에도 두경부 전체적인 피폭이 일어나고 두경부 주요 장기 중 갑상선과 식도, 눈에서 높은 피폭선량 값을 확인하였다. 그리고 설계한 피폭저감 장치를 적용에 따라 갑상선과 식도, 눈에서 70~80% 피폭이 저감됨을 확인하였다. 본 연구 결과는 치과방사선에 대한 선량 데이터 확보와 방사선 피폭 저감 연구에 있어 매우 유용하게 이용될 것으로 기대된다.

엉덩관절 정면 검사 시 환자 피폭 감소 (Reducing Radiation Exposure During X-ray Imaging of Both Hip AP)

  • 신성규;이효영
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.313-320
    • /
    • 2016
  • 본 연구는 엉덩관절 정면 검사 시 격자 제거와 관전압, Cu Filter의 조합을 이용하여 환자의 피폭을 감소하고자 시행하였다. 엉덩관절 정면 검사법을 대상으로 격자의 사용과 제거 상태에 따라 각각 관전압을 60~90 kV로 변화시키고 Cu Filter를 0.1~0.3 mm로 추가시켜 입사선량, 유효선량을 측정하고 영상의 진단적 가치를 평가하였다. 격자를 사용하고 관전압 60 kV, none filter에서 입사선량은 4.77 mGy로 가장 높은 측정치를 나타냈고 격자를 사용하지 않고 90 kV, 0.3 mm Cu filter 조건에서의 입사선량은 0.14 mGy로 가장 낮았으며 약 34배의 차이를 나타냈다. ICRP Pub. 60을 기준으로 70 kV에서 고환, 난소의 유효선량은 격자를 사용 했을 경우 0.255 mSv, 격자를 제거하였을 경우에는 0.049 mSv로 약 5.2배의 차이를 나타냈다. ICRP Pub. 103을 기준으로 70 kV에서 고환, 난소의 유효선량은 격자를 사용했을 경우 0.090 mSv 격자를 제거하였을 경우에는 0.020 mSv로 약 4.5배의 차이를 나타냈다. 격자를 사용하였을 경우의 노광지수는 671~782, 격자를 제거하였을 경우에는 513~606 사이로 적정 노출조건이었으며 영상평가결과 모두 진단적 가치가 있는 영상으로 나타났다. 따라서 엉덩관절 정면 검사 시 격자를 제거하고 관전압을 높이고 Cu Filter를 추가시켜 촬영하면 환자의 피폭을 줄일 수 있을 것이다.

Anticancer and Radiosensitization Efficacy of Nanocomposite Withania somnifera Extract in Mice Bearing Tumor Cells

  • Abdallah, Nadia M;Noaman, Eman;Eltahawy, Noaman A;Badawi, Abdelfattah M;Kandil, Eman;Mansour, NA;Mohamed, Hebatallah E
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권9호
    • /
    • pp.4367-4375
    • /
    • 2016
  • The objective of the present study was to evaluate the anticancer and radio-sensitizing efficacy of a Withania somnifera extract/Gadolinium III oxide nanocomposite (WSGNC) in mice. WSGNC was injected to solid Ehrlich carcinoma-bearing mice via i.p. (227 mg/kg body weight) 3 times/week during 3 weeks. Irradiation was performed by whole body fractionated exposure to 6Gy, applied in 3 doses of 2 Gy/week over 3 weeks. Biochemical analyses as well as DNA fragmentation were performed. Treatment of solid Ehrlich carcinoma bearing mice with WSGNC combined with ${\gamma}$-radiation led to a significant decrease in the tumor size and weight associated with a significant decrease in mitochondrial enzyme activities, GSH content and SOD activity as well as a significant increase in caspase-3 activity, MDA concentration and DNA fragmentation in cancer tissues. Combined treatment of WSGNC and low dose of ${\gamma}$-radiation showed great amelioration in lipid peroxidation and antioxidant status (GSH content and SOD activity) in liver tissues in animals bearing tumors. It is concluded that WSGNC can be considered as a radio-sensitizer and anticancer modulator, suggesting a possible role in reducing the radiation exposure dose during radiotherapy.

X선 촬영실에서 방호복 유무에 따른 공간산란선량의 측정 비교 (Measurement of Comparison to Scattering Dose Space According to the Presence or Absence of Protective Clothing in the X-ray Room)

  • 허예지;김교태;조창훈;강수만;박지군;강상식;노시철;정봉재
    • 한국방사선학회논문지
    • /
    • 제6권4호
    • /
    • pp.313-320
    • /
    • 2012
  • 현재 의료기관은 의학 기술의 발전과 더불어 건강에 대한 관심이 고조됨에 따라 방사선 발생장치의 이용이 급증하고 있다. 방사선으로 인해 환자가 받는 직접적인 피폭을 가능한한 줄이는 목적도 중요하지만 촬영시 공간 내에서 받을 수 있는 간접적인 피폭을 줄여 의료업에 종사하는 의료인, 방사선 작업종사자 및 보호자의 피폭을 줄여야 한다. 엑스선 촬영실에서는 방사선작업종사자 및 보호자에게 방호복의 착용을 권고하고 있으나 불가피하게 방사선작업종사자 및 보호자가 환자의 촬영 보조를 할 경우, 방호복 착용에 의한 중량감 및 불편함 때문에 방호복 착용이 등한시 되고 있다. 이에 본 연구에서는 방호복 유무에 따라 공간산란선량을 측정하고 거리, 가로면 각도 및 높이에 따라 측정함으로써 방호복 착용의 중요성을 알아보고자 하였다.

Y-90 microsphere 로부터 생성되는 제동복사선의 차폐를 위한 차폐체 개발 연구 (Development of shielding device for bremsstrahlung radiation from Y-90 microspheres)

  • 박준영
    • 핵의학기술
    • /
    • 제23권1호
    • /
    • pp.50-53
    • /
    • 2019
  • 본 연구는 고에너지의 베타선을 방출하는 Y-90 미세구의 경동맥방사선색전술 시 발생되는 제동복사선에 의한 불필요한 외부피폭을 줄이고자 텅스텐 차폐체를 개발하였다. 본 연구에서는 다양한 용량(1 GBq, 2 GBq, 4 GBq)의 $SIR-Spheres^{(R)}$ Y-90 미세구를 사용하여, 텅스텐 차폐체 표면으로부터 10 cm, 50 cm, 100 cm인 곳에서 GM tube식 디지털 서베이미터로 선량률을 측정하였다. 텅스텐 차폐체 표면 10 cm 위치에서 차폐율을 분석한 결과 4 GBq의 $SIR-Spheres^{(R)}$ Y-90 미세구의 경우 90.9%, 2 GBq의 경우 88.9%, 1 GBq의 경우 88.8%의 차폐율을 보였고, 표면 50 cm 위치에서 차폐율은 4 GBq의 $SIR-Spheres^{(R)}$ Y-90 미세구의 경우 89.2%, 2 GBq의 경우 87.5%, 1GBq의 경우 86.3%로 나타났다. 텅스텐 차폐체 표면 100 cm 위치에서 텅스텐 차폐체는 평균 75.1%의 차폐율을 보이는 것으로 확인할 수 있었다. 높은 용량이 함유된 $SIR-Spheres^{(R)}$ Y-90 미세구의 경동맥방사선색전술시 방사선 작업종사자와 선원간의 거리가 짧고, 작업시간이 길기 때문에 제동복사선에 의한 피폭에 노출될 수 있다. 본 연구를 통해 개발된 텅스텐 차폐체는 향후 임상에서 경동맥방사선색전술 시 제동복사선에 의한 외부피폭을 줄이는데 활용될 수 있을 것이라 기대 된다.

방사선 방어의 최적화 절차론 개발에 관한 연구 (A Study on the Development of Optimization Procedure for Radiological Protection)

  • 송종순
    • Journal of Radiation Protection and Research
    • /
    • 제19권1호
    • /
    • pp.1-11
    • /
    • 1994
  • 방사선 방어의 최적화 수행에는 적용의 다양함 등을 고려할 때, 절차론이 반드시 필요하게 된다. 본 연구에서는 발전소 설계 단계에서의 최적화 절차론을 제시하고, 이를 피폭 저감대안의 선정 문제에 적용하였다. 의사결정 보조기법으로는 다기준 기법을 사용하였으며, 그 결과 대안의 우선순위를 결정하고, 최적화의 결과를 실제 적용하는 문제를 분석하였다. 이러한 최적화 절차론은 발전소 이외에 방사성 폐기물 관리나 방사선의 의학적 이용 둥의 분야에도 적용될 수 있다.

  • PDF

Study on Dual-Energy Signal and Noise of Double-Exposure X-Ray Imaging for High Conspicuity

  • Song, Boram;Kim, Changsoo;Kim, Junwoo
    • Journal of Radiation Protection and Research
    • /
    • 제46권4호
    • /
    • pp.160-169
    • /
    • 2021
  • Background: Dual-energy X-ray images (DEI) can distinguish or improve materials of interest in a two-dimensional radiographic image, by combining two images obtained from separate low and high energies. The concepts of DEI performance describing the performance of double-exposure DEI systems in the Fourier domain been previously introduced, however, the performance of double-exposure DEI itself in terms of various parameters, has not been reported. Materials and Methods: To investigate the DEI performance, signal-difference-to-noise ratio, modulation transfer function, noise power spectrum, and noise equivalent quanta were used. Low- and high-energy were 60 and 130 kVp with 0.01-0.09 mGy, respectively. The energy-separation filter material and its thicknesses were tin (Sn) and 0.0-1.0 mm, respectively. Noise-reduction (NR) filtering used the Gaussian-filter NR, median-filter NR, and anti-correlated NR. Results and Discussion: DEI performance was affected by Sn-filter thickness, weighting factor, and dose allocation. All NR filtering successfully reduced noise, when compared with the dual-energy (DE) images without any NR filtering. Conclusion: The results indicated the significance of investigating, and evaluating suitable DEI performance, for DE images in chest radiography applications. Additionally, all the NR filtering methods were effective at reducing noise in the resultant DE images.