• 제목/요약/키워드: reducing radiation of exposure

검색결과 142건 처리시간 0.025초

서울시 환경보건정책 로드맵 수립 (Process and Results of Seoul Metropolitan Government's Environmental Health Policy Road Map)

  • 임지애;권호장;김신범;최영은;구슬기;정회성;김명한;최경호
    • 한국환경보건학회지
    • /
    • 제40권5호
    • /
    • pp.425-434
    • /
    • 2014
  • Objectives: The purpose of this study is to introduce the establishment process and results of the Seoul Metropolitan Government's road map on environmental health policy. Methods: The process consisted of expert group meetings, civic participation, research, and questionnaire survey for priority environmental health policy agenda items in Seoul. Results: The announced vision for the environmental health policy was "a healthy environment, safety in Seoul". This policy was established in order to define environment health policy initiatives for a period of five years with an aim to protect Seoul citizens' health from hazardous environmental factors. The resulting Seoul environmental health policy consisted of four areas and 16 key agenda items. The four areas were "Protection for children against hazardous materials", "Enhancement of health and safety of all", "Carcinogen-free and endocrine-disrupting chemical-free Seoul (reducing environmental exposure to hazardous materials), and "Establish the foundation of environmental health policy". Sixteen key agenda items include the enhancement of management of spaces for children, certification of environmental health status at schools, establishment of a unit responsible for the environmental health of children, strengthening environmental health management for susceptible populations (children, the aged, and the socioeconomically vulnerable), management of hazardous materials, physical hazardous factors (noise, radiation, etc.), indoor air quality, and the enhancement of monitoring, research, and regulation of environment health. Conclusion: The Seoul Metropolitan Government established an environmental health policy road map for a five-year period (2013-2017). To implement this environmental health policy, budget allocation, and detailed execution plans are required.

UVB 1회 조사 후 시간에 따른 BALB/c마우스의 피부 항산화효소 활성도 변화 (Temporal changes of the activity of catalase, superoxide dismutase, and glutathione peroxidase in BALB/c mice skin after a single dose UVB irradiation)

  • 이정희;박경애;이희주;박명숙;전상은;박경찬;최스미
    • Journal of Korean Biological Nursing Science
    • /
    • 제3권1호
    • /
    • pp.53-61
    • /
    • 2001
  • Skin is constantly exposed to air, solar radiation, ozone and other air pollutants formulating free radicals. The reactive oxygen species(ROS), formed under these conditions, are associated with skin cancers, cutaneous photoaging, and cutaneous inflammatory disorders. In this study, we sought to establish an animal model for UVB-induced skin alteration using BALB/c mice. The level of UVB irradiation used in this model was within physiological dose. BALB/c mice were exposed to a single dose of UVB ($200mJ/cm^2$ and were sacrificed at 3, 6, 24, and 48 hours following the irradiation. The effect of a single exposure to UVB irradiation on skin catalase(CAT), superoxide dismutase(SOD), and glutathione peroxidase(GPx) activities were examined. Significant decrease in the activity of all enzymes were observed at 6 hours after irradiation(p<.05). The activity of CAT decreased more sharply than those of SOD and GPx, and then remained depressed until 48 hours after UVB irradiation, whereas the activity of GPx recovered to basal level at 48 h after UVB irradiation. Our results indicate that BALB/c mouse could be an adequate animal model of UVB irradiation experiment. These results will also provide fundamental knowledge for the effective nursing strategies in reducing UV-induced skin disorders.

  • PDF

난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study (Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition)

  • 이성재;신충훈;최소영;이동형;유순미;송흥권;윤인하
    • 대한방사선치료학회지
    • /
    • 제34권
    • /
    • pp.73-82
    • /
    • 2022
  • 목 적: 본 연구는 난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 HalcyonTM Fast kV CBCT를 사용하였을 때 난소에 미치는 흡수선량과 영상의 품질을 분석하여 유용성을 평가하고자 한다. 대상 및 방법: 인체모형 팬텀(Alderson Rando Phantom, USA)의 전산화단층촬영 영상에 측정에 필요한 자궁경부와 난소의 윤곽묘사(contouring)를 하였고, 해당 장기 단면에 광자극발광선량계(Optically Stimulated Luminescence Dosimeter, OSLD, InLight system, Landauer, USA)를 각각 3개씩 부착하였다. TruebeamTM의 Pelvis mode(이하 TP)와 HalcyonTM의 Pelvis mode(이하 HP) 그리고 HalcyonTM의 Pelvis Fast mode(이하 HPF)에서 자궁경부와 난소에 들어가는 흡수선량을 측정하기 위해 촬영 범위를 17.5 cm와 12.5 cm로 촬영 범위를 축소한 영상을 촬영하였다. 총 10회의 누적선량을 합산하였고, 자궁경부암 치료 횟수인 23회의 값으로 치환하여 비교하였다. 또한 영상 장비 간의 CBCT 영상 품질을 비교하기 위해 Catphan 504 팬텀(The Phantom Laboratory, USA)을 이용하여 균일도(Uniformity), 저 대조도 가시(Low contrast visibility, LCV), 공간분해능(Spatial resolution), 기하학적 왜곡(Geometric Distortion)을 비교 분석하였다. 각각 3회 반복 측정하여 Doselab (Versions: 6.8, Mobius Medical Systems) 프로그램으로 분석 후 평균값을 구하였다. 결 과: CBCT에 의한 흡수선량을 OSLD로 측정한 결과 동일한 조건일 시 TP와 HP는 유의미한 결과를 얻지 못하였다. 가장 큰 감소 값을 보인 모드는 TP 대비 HPF였다. HPF는 17.5 cm의 촬영 범위에서 흡수선량이 TP보다 자궁경부가 약 39.82%, 난소에서 약 19.8% 감소 하였고, 12.5 cm 으로 촬영 범위를 축소할 경우 자궁경부는 34.2%, 난소 50.5%로 감소 시킬 수 있었다. 또한 위 실험에서 사용된 영상의 품질을 평가한 결과 Geometric Distortion 1mm 이내(SBRT 기준), Uniformity HU, LCV 2.0% 이내 Spatial Resolution 3 lp/mm 이상으로 장비사의 기준치를 준수하였다. 결 론: 본 실혐 결과에 따라 난소전위술을 시행한 가임기 여성의 방사선치료 시 CBCT로 인한 피폭선량을 낮추기 위해서는 TruebeamTM 보다 다양한 조건을 선택 할 수 있는 HalcyonTM이 유용할 것으로 평가 되며, 특히 낮은 mAs로도 영상의 품질을 유지하는 HalcyonTM의 Fast kV CBCT를 권장한다. 다만 다른 치료 장비에서도 난소전위를 시행한 환자는 촬영 범위를 조정하는 것으로 저선량에 대한 추가적인 피폭 감소시킬 수 있을 것으로 사료된다.

Synthesis and Spectroscopic Characterization of Manganese(II), Iron(III) and Cobalt(III) Complexes of Macrocyclic Ligand. Potential of Cobalt(III) Complex in Biological Activity

  • El-Tabl, Abdou S.;Shakdofa, Mohamad M.E.;El-Seidy, Ahmed M.A.
    • 대한화학회지
    • /
    • 제55권6호
    • /
    • pp.919-925
    • /
    • 2011
  • A new series of manganese(II), iron(III) and cobalt(III) complexes of 14-membered macrocyclic ligand, (3,6,10,13,16,19-hexaazabicyclo[6.6.6]icosane-1,8-diamine) have been prepared and characterized by elemental analyses, IR, UV-VIS, $^1H$- and $^{13}C$- NMR spectra, magnetic susceptibilities, conductivities, and ESR measurements. Molar conductance measurements in DMF solution indicate that the complexes are electrolytes. The ESR spectrum for cobalt(III) complex in $CD_3OD+10%D_2O$ after exposure to $^{60}Co-{\gamma}$-rays at 77 K using a 0.2217 M rad $h^{-1}$ vicrad source showed $g_{\perp}$ > $g_{\parallel}$ > $g_e$, indicating that, the unpaired electron site is mainly present in the $d_z2$ orbital with covalent bond character. In this case, the ligand hyperfine tensors are nearly collinear with ${\gamma}$-tensors, so there is no major tendency to bend. Therefore, little extra delocalization via the ring lobe of the $dz^2$ orbital occurs. However, the ESR spectrum in solid state after exposure to $^{60}Co-{\gamma}$-rays at 77 K showed $g_{\parallel}$ > $g_{\perp}$ > $g_e$, indicating that, the unpaired electron site is mainly present in the $d_x2_{-y}2$ ground state as the resulting spectrum contains a large number of randomly oriented molecules provided that, the principle directions of g and A tensors. Manganese (II) complex 2, $[H_{12}LMn]Cl_4.2H_2O$, showed six isotropic lines characteristic to an unpaired electron interacting with a nucleus of spin 5/2, however, iron(III) complex 3, $[H_{12}LFe]Cl_5.H_2O$, showed spectrum of a high spin $^{57}Fe$ (I=1/2), $d^5$ configuration. The geometry of these complexes was supported by elemental analyses, IR, electronic and ESR spectral studies. Complex 1 showed exploitation in reducing the amount of electron adducts formed in DNA during irradiation with low radiation products.

자동 노출 조절장치를 사용한 흉부 후·전 방향 방사선 검사 시 격자 유·무에 따른 환자 선량과 영상품질 비교 연구 (A Comparative Study of Patient Dose and Image Quality according to the Presence or Absence of Grid During Chest PA Radiography using an Auto Exposure Control System)

  • 이소민;김한용;김동환;주영철
    • 한국방사선학회논문지
    • /
    • 제17권4호
    • /
    • pp.573-579
    • /
    • 2023
  • 본 연구는 자동노출조절장치를 사용하는 흉부 후·전 방향 방사선검사(Chest PA) 시 격자 사용 유·무 및 가상격자 사용에 따른 선량과 영상 품질의 차이 비교를 통해, Chest PA 시 임상적으로 새로운 격자 조합을 제안하고자 한다. 본 연구는 인체모형팬텀을 대상으로 Chest PA 자세에서 진행했다. 선량계는 흉추 6번 높이에 위치하였고, 조사 조건은 110 kVp, 320 mA, 1.6 mAs, SID는 180 cm, 조사야 크기는 17" × 17"로 동일하게 적용하였다. 물리적 격자를 적용한 상태와 미적용 상태에서 각각 30개의 영상을 얻었고, 물리적 격자 미적용 영상에 가상격자를 적용한 영상 30개를 추가로 획득하였다. 선량은 입사표면선량(ESD)을 측정하였고, 화질은 신호대잡음비(SNR)와 대조도대잡음비(CNR)를 측정하여 비교 분석하였다. 본 연구 결과 ESD는 물리적 격자를 사용하지 않을 경우 약 48%의 감소 효과가 있었다. SNR은 물리적 격자 미사용 시가 사용 시보다 약 32% 증가하였고, 가상격자를 사용한 경우에는 격자 사용 시 보다 약 18% 증가하였다. CNR은 물리적 격자 미사용 시가 사용 시보다 약 30% 증가하였고, 가상격자를 사용한 경우에는 격자 사용 시보다 약 16% 증가하였다. 본 연구의 결과, 물리적인 격자 대신 가상격자 사용 시 영상의 품질은 유지하되, 환자 선량은 감소시킬 수 있을 것으로 생각된다.

두개골-선조체 팬텀을 이용한 선량 저감화 방안 연구 (The Study of Radiation Exposure Reduction by Developing Corpus Striatum Phantom)

  • 김정수;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.595-603
    • /
    • 2017
  • 본 연구는 파킨슨질환의 진행 정도를 평가할 수 있는 선조체를 모사한 brain 팬텀을 직접 제작하여, PET-CT검사 시 최적의 영상의 질을 유지하면서 CT 스캔에 의한 brain 선량 저감을 위한 가능성을 평가하였다. 팬텀의 hot sphere와 background (radi oacti vi ty rati o 3:1)에 $^{18}F$ FP-CIT를 주입하고, 관전압(100, 120 kVp)과 관전류(80, 140, 200 mAs)의 조건을 변화시키며 CT 스캔을 실험하였다(기준조건; 120 kVp, 140 mAs). 각 조건에 따라 예상유효선량을 conversion factor를 적용해 계산하였고, SNR과 CRChot의 영상평가 인자를 설정하여 영상의 질을 평가하였다. 실험결과 CT 촬영 기준조건 이하에서의 예상유효선량은 최소 10%에서 최고 60% 정도 감소하였고, 기준조건 이상에서의 예상유효선량은 40% 증가하였다. 또한 PET 영상의 SNR과 CRChot의 유의한 차이는 없었으므로, 관전압과 관전류의 감소에 따라 brain 선량이 감소함을 확인하였다. 이와 동시에 스캔 조건의 변화에도 불구하고 SNR과 CRChot 측면에서의 영상의 질에는 유의한 변화가 없었다. 이러한 사실은 낮은 선량 조건으로도 기존의 선량 조건으로 획득한 영상의 질 수준을 얻을 수 있었으므로, 추후 brain PET-CT 스캔의 선량감소와 동시에 영상의 질 향상에 관한 연구의 기초자료로 활용이 가능할 것으로 사료된다.

두부 CT 검사에서 선량감소를 위한 알고리즘 변환방법의 유용성 평가 (Usefulness Evaluation of Algorithm Conversion Method for Dose Reduction in Brain CT Examination)

  • 김현주
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.481-487
    • /
    • 2019
  • 두부 CT 검사 시 일반적으로 검사 시 적용하는 스캔조건 및 알고리즘을 기준으로 선정 후 알고리즘 변경 적용을 통한 선량감소효과를 실험을 통해 알아보고자 하였다. 그 결과 선량감소효과는 관전압 보다 관전류 변화 시 의미가 있었으며, 인체 팬텀을 이용한 화질 평가는 Smooth 알고리즘적용 후 선량을 감소 시 Bone 알고리즘적용 후 선량을 감소 시 보다 상대적으로 화질 감소가 적었으며, 특히 Bone 알고리즘적용 시에는 평균 CT Number 또는 Pixel value의 편차가 상대적으로 크게 측정되었다. 즉 선량은 감소되고 화질은 유지하여 환자의 피폭 선량을 감소시키고 동일한 화질의 영상을 얻을 수 있는 조건은 Smooth 알고리즘 적용과 120 kVp, 160 mA라는 결과 값을 얻을 수 있었다. 이 때 선량은 약 28% 감소되며 평균 CT Number 또는 Pixel value도 오차가 상대적으로 적게 측정 되었다. 향 후 스캔조건 및 다양한 알고리즘 적용 후 그 결과를 검진 또는 추적검사 등으로 내원한 환자에게 적용하여 검사 한다면 환자 피폭선량 감소에 있어 매우 유용할 것으로 사료된다.

퇴행성 관절염 환자를 대상으로 새로운 진통제 평가를 위한 임상시험자료의 GEE 분석 (Analysis of Repeated Measured VAS in a Clinical Trial for Evaluating a New NSAID with GEE Method)

  • 임회정;김윤이;정영복;성상철;안진환;노권재;김정만;박병주
    • Journal of Preventive Medicine and Public Health
    • /
    • 제37권4호
    • /
    • pp.381-389
    • /
    • 2004
  • Objective : To compare the efficacy between SKI306X and Diclofenac by using generalized estimating equations (GEE) methodology in the analysis of correlated bivariate binary outcome data in Osteoarthritis (OA) diseases. Methods : A randomized, double-blind, active comparator-controlled, non-inferiority clinical trial was conducted at 5 institutions in Korea with the random assignment of 248 patients aged 35 to 75 years old with OA of the knee and clinical evidence of OA. Patients were enrolled in this study if they had at least moderate pain in the affected knee joint and a score larger than 35mm as assessed by VAS (Visual Analog Scale). The main exposure variable was treatment (SKI 306X vs. Diclofenac) and other covariates were age, sex, BMI, baseline VAS, center, operation history (Yes/No), NSAIDS (Y/N), acupuncture (Y/N), herbal medicine (Y/N), past history of musculoskeletal disease (Y/N), and previous therapy related with OA (Y/N). The main study outcome was the change of VAS pain scores from baseline to the 2nd and 4th weeks after treatment. Pain scores were obtained as baseline, 2nd and 4th weeks after treatment. We applied GEE approach with empirical covariance matrix and independent(or exchangeable) working correlation matrix to evaluate the relation of several risk factors to the change of VAS pain scores with correlated binary bivariate outcomes. Results : While baseline VAS, age, and acupuncture variables had protective effects for reducing the OA pain, its treatment (Joins/Diclofenac) was not statistically significant through GEE methodology (ITT:aOR=1.37, 95% CI=(0.8200, 2.26), PP:aOR=1.47, 95% CI=(0.73, 2.95)). The goodness-of-fit statistic for GEE (6.55, p=0.68) was computed to assess the adequacy of the fitted final model. Conclusions : Both ANCOVA and GEE methods yielded non statistical significance in the evaluation of non-inferiority of the efficacy between SKI306X and Diclofenac. While VAS outcome for each visit was applied in GEE, only VAS outcome for the fourth visit was applied in ANCOVA. So the GEE methodology is more accurate for the analysis of correlated outcomes.

월면토를 이용한 달 유인 우주기지 보호층의 기술적 요구조건에 관한 연구 (Investigation of Technical Requirements for a Protective Shield with Lunar Regolith for Human Habitat)

  • 이장근;공정;진현우;유병현;김영재
    • 한국지반공학회논문집
    • /
    • 제39권10호
    • /
    • pp.49-55
    • /
    • 2023
  • 달 극지방에 얼음이 존재한다는 사실을 발견하고 달 현지자원활용과 유인기지 건설에 국제적 관심이 증대되고 있다. 대기가 없는 달은 지구환경과 다르게 운석충돌, 우주방사선, 극한 온도편차의 위험에 노출되고 있다. 이러한 3대 위협요소로부터 유인 우주기지를 보호하기 위해 보호층 시공이 반드시 요구된다. 월면토를 보호층 시공 재료로 사용하는 것은 지구-달 운송에 필요한 비용 절감과 대량의 원자재 확보라는 관점에서 상당히 매력적이다. 또한, 별도의 제작 및 통합 일정을 위한 추가적인 시간이 필요치 않고 지구에서 재보급 없이 쉽게 수리 및 개조가 가능하다. 환경이 변하는 경우에도 유인 우주기지의 구조적 한계 내에서 보호층 두께 조절이 가능하다. 월면토를 이용한 보호층과 관련한 다양한 연구들이 진행되어 왔으나, 보호층의 요구조건에 대해서는 다양한 의견들이 제시되어 왔다. 본 논문에서 달 지상 3대 위협요소별로 상세히 살펴본 결과를 토대로 장기 유인거주를 위해서는 2m 이상의 보호층 시공이 필요한 것으로 판단하였다. 이를 기반으로 보호층 시공에 필요한 기술과 달 지상에서 급속으로 시공이 가능한 방안을 제시하고자 한다.

An Efficient CT Image Denoising using WT-GAN Model

  • Hae Chan Jeong;Dong Hoon Lim
    • 한국컴퓨터정보학회논문지
    • /
    • 제29권5호
    • /
    • pp.21-29
    • /
    • 2024
  • CT 촬영 시 방사선량을 줄이면 피폭 위험성을 낮출 수 있으나, 영상 해상도가 크게 저하 될 뿐아니라 잡음(noise) 발생으로 인해 진단의 효용성이 떨어진다. 따라서, CT 영상에서의 잡음제거는 영상복원 분야에 있어 매우 중요하고 필수적인 처리 과정이다. 영상 영역에서 잡음과 원래 신호를 분리하여 잡음만을 제거하는 것은 한계가 있다. 본 논문에서는 웨이블릿 변환 기반 GAN 모델 즉, WT-GAN(wavelet transform-based GAN) 모델을 이용하여 CT 영상에서 효과적으로 잡음 제거하고자 한다. 여기서 사용된 GAN 모델은 U-Net 구조의 생성자와 PatchGAN 구조의 판별자를 통해 잡음제거 영상을 생성한다. 본 논문에서 제안된 WT-GAN 모델의 성능 평가를 위해 다양한 잡음, 즉, 가우시안 잡음(Gaussian noise), 포아송 잡음 (Poisson noise) 그리고 스펙클 잡음 (speckle noise)에 의해 훼손된 CT 영상을 대상으로 실험하였다. 성능 실험 결과, WT-GAN 모델은 전통적인 필터 즉, BM3D 필터뿐만 아니라 기존의 딥러닝 모델인 DnCNN, CDAE 모형 그리고 U-Net GAN 모형보다 정성적이고, 정량적인 척도 즉, PSNR (Peak Signal-to-Noise Ratio) 그리고 SSIM (Structural Similarity Index Measure) 면에서 우수한 결과를 보였다.