• Title/Summary/Keyword: reduced system method

Search Result 2,896, Processing Time 0.033 seconds

Design of reduced-order controllers in two-degree-of-freedom control systems

  • Nakamura, T.;Obinata, G.;Inooka, H.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.753-758
    • /
    • 1988
  • In this paper, we propose a new method of designing a reduced-order controller for a linear discrete-time system. Firstly, we study a design problem for a two-degree-of-freedom control system with a feedforward controller. Secondly, in order to obtain a reduced-order controller, frequency-weighted least squares approximation problems are considered. Thirdly, we propose a synthesis procedure of a reduced-order controller. Finally, an example is given to illustrate the effectiveness of this proposed method.

  • PDF

Decentralized H$\infty$Controller Design-reduced order observers approach

  • Jo, Cheol H.;Lee, Sang-Hyek;Seo, Jin H.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.52-55
    • /
    • 1996
  • In this paper, we consider the decentralized reduced-order H$_{\infty}$ controller for the general plant. Simplifying method is suggested for the general plant with the decentralized controller structure. When the controller is reconstructed for the original system, the decentralizability of the controller for the transformed system is generally destroyed with the older method. We solve this problem. For the simplified system, the structure of the decentralized controller is suggested..

  • PDF

A Reduced Equivalent 5 conductors Modeling of the Catenary System (전차선로 시스템의 5 도체 등가 축약 모델링)

  • 이한민;오광해;이장무;창상훈;장길수;권세혁
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.12
    • /
    • pp.684-690
    • /
    • 2003
  • This paper estimates line constants of equivalent five-conductors model using the reduced equivalent method. Actually, the catenary system is considered by the equivalent five-conductors model in the electrical aspect. Therefore, we should compose the catenary system of the equivalent five-conductors model, then the line constants of this equivalent five-conductors model are calculated. This paper shows the reducing process about the real system of the field by using the proposed theory. Also the line constants of reduced system are provided in this paper.

Study on the Structural System Condensation using Multi-level Sub-structuring Scheme in Large-scale Problems (대형 시스템에서의 다단계 부분구조 기법을 이용한 시스템 축소기법에 관한 연구)

  • Baek, Sung-Min;Kim, Hyun-Gi;Cho, Meang-Hyo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.356-361
    • /
    • 2008
  • Eigenvalue reduction schemes approximate the lower eigenmodes that represent the global behavior of the structures. In the previous study, we proposed a two-level condensation scheme (TLCS) for the construction of a reduced system. And we have improved previous TLCS with combination of the iterated improved reduced system method (IIRS) to increase accuracy of the higher modes intermediate range. In this study, we apply previous improved TLCS to multi-level sub-structuring scheme. In the first step, the global system is recursively partitioned into a hierarchy of sub-domain. In second step, each uncoupled sub-domain is condensed by the improved TLCS. After assembly process of each reduced sub-eigenvalue problem, eigen-solution is calculated by Lanczos method (ARPACK). Finally, Numerical examples demonstrate performance of proposed method.

  • PDF

NONLINEAR FLUTTER ANALYSIS USING INVISCID REDUCED ORDER MODELING TECHNIQUE (비점성 저차모델링 기법을 활용한 비선형 플러터 해석)

  • Kim, Y.H.;Kim, D.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.458-464
    • /
    • 2011
  • A new method identifies coupled fluid-structure system with a reduced set of state variables is presented. Assuming that the structural model is known a priori either from an analysis or a test and using linear transformations between structural and aeroelastic states, it is possible to deduce aerodynamic information from sampled time histories of the aeroelastic system. More specifically given a finite set of structural modes the method extracts generalized aerodynamic force matrix corresponding to these mode shapes. Once the aerodynamic forces are known, an aeroelastic reduced-order model can be constructed in discrete-time, state-space format by coupling the structural model and the aerodynamic system. The resulting reduced-order model is suitable for constant Mach, varying density analysis.

  • PDF

An Accelerated Inverse Perturbation Method for Structural Damage Identification

  • Park, Young-Jae;Lee, Usik
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.637-646
    • /
    • 2003
  • In the previous study, the inverse perturbation method was used to identify structural damages. Because all unmeasured DOFs were considered as unknown variables, considerable computational effort was required to obtain reliable results. Thus, in the present study, a system condensation method is used to transform the unmeasured DOFs into the measured DOFs, which eliminates the remaining unmeasured DOFs to improve computational efficiency. However, there may still arise a numerically ill-conditioned problem, if the system condensation is not adequate for numerical Programming or if the system condensation is not recalibrated with respect to the structural changes. This numerical problem is resolved in the present study by adopting more accurate accelerated improved reduced system (AIRS) as well as by updating the transformation matrix at every step. The criterion on the required accuracy of the condensation method is also proposed. Finally, numerical verification results of the present accelerated inverse perturbation method (AIPM) are presented.

The High Power Factor Control of a Single Phase PWM Converter using a Reduced-Order Luenberger Observer (축소차원 Luenberger 관측기를 이용한 단상 PWM 컨버터의 고역률 제어)

  • Yang, Lee-U;Kim, Yeong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.529-535
    • /
    • 2000
  • In this paper, a current control system of a single phase PWM AC/DC converter using a reduced-order Luenberger observer without source voltage sensors is proposed. The sinusoidal input current and unity input power factor are realised based on the estimated source voltage performed by the reduced-order Luenberger observer using actual currents and DC link voltage. The poles of the reduced-order Luenberger observer are placed in the left half plane of s-plane by the pole-placement method in order to acquire the stability of the observer. The magnitude and the phase of the estimated source voltage are used to accomplish the unity power factor. The proposed method is implemented by DSP(Digital Signal Processor). Experimental Results verify that the reduced-order observer estimates the source voltage without the estimation error and the control system accomplishes the unity power factor, and constant DC link voltage.

  • PDF

Reduction Method based on Sub-domain Structure using Reduced Pseudo Inverse Method (축소 의사역행렬과 영역분할 기반 축소모델 구축 기법 연구)

  • Kim, Hyun-Gi;Cho, Meang-Hyo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.139-145
    • /
    • 2009
  • Reduction scheme is remarkably useful in the case requiring the repeated calculation procedure. Recently, the efficiency of the reduction scheme has been improved by combining scheme of sub-domain method. But, when the global domain is partitioned into a few sub-domains, sub-domains without constraints can be produced. it is needed to extract the ritz vector from each sub-domain to construct the reduced system of each sub-domain. it is easy to extract the ritz vector from sub-domain with constraint. on the other hand, pseudo inverse method should be employed to extract the ritz vector from sub-domain without constraint. generally, the pseudo inverse takes a large number of computing time to obtain a reduced system of a sub-domain without boundary condition. This trouble can be overcome by the reduced pseudo inverse scheme which proposed in this study. This scheme is based on the static condensation that is not related with selection of the primary degrees of freedom. Numerical examples demonstrate that present method saves computational cost effectively and predicts the accurate eigenvalues.

  • PDF

A MODEL-ORDER REDUCTION METHOD BASED ON KRYLOV SUBSPACES FOR MIMO BILINEAR DYNAMICAL SYSTEMS

  • Lin, Yiqin;Bao, Liang;Wei, Yimin
    • Journal of applied mathematics & informatics
    • /
    • v.25 no.1_2
    • /
    • pp.293-304
    • /
    • 2007
  • In this paper, we present a Krylov subspace based projection method for reduced-order modeling of large scale bilinear multi-input multi-output (MIMO) systems. The reduced-order bilinear system is constructed in such a way that it can match a desired number of moments of multi-variable transfer functions corresponding to the kernels of Volterra series representation of the original system. Numerical examples report the effectiveness of this method.

Approximation of the State Variables of the Original System from the Balanced Reduced Model (발란싱축소화로 구한 축소모델로부터 원 시스템 상태변수를 구하는 방법)

  • 정광영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.333-333
    • /
    • 2000
  • When the generalized singular perturbation method is used for model reduction, the state variables of the original system is reconstructed from the reduced order model. The state reduction error is defined, which shows how well the reconstructed state variables approximate the state variables of the original system equation.

  • PDF