• 제목/요약/키워드: rectum

검색결과 415건 처리시간 0.023초

가축에서 간이 체온측정 비접촉성 체온계 개발을 위한 임상적 연구 (Clinical Studies for the Development of Non-contact Thermometer to Take Easily the Body Temperature of Domestic Animals)

  • 김용준;이대영;한경호
    • 한국임상수의학회지
    • /
    • 제20권3호
    • /
    • pp.357-363
    • /
    • 2003
  • These studies were carried out to develop non-contact thermometer to take easily the body temperature of domestic animals instead of taking rectal temperature. For the studies, 86 cattle, 57 horses, 72 pigs, 43 goats, and 42 dogs were used and body parts as neck, flank, axilla, lateral abdomen, gluteus, inguinal region, or jugular groove were chosen for taking temperature according to different species. Two types of commercial non-contact thermometers were used to take the temperature of certain body part and at the same time the rectal temperature using digital thermo-meter was taken to compare the difference of temperature between rectum and certain body part. The difference of mean temperature in cattle between rectum and axilla and flank were 0.52 and $2.41^{\circ}C$, respectively, using non-contact thermometer I, whereas $3.02^{\circ}C$ between rectum and flank using thermometer II. The difference of mean temperature in horses between rectum and axilla, gluteus, and jugular groove were 0.52, 1.49, and $0.26^{\circ}C$, respectively, using thermometer I, whereas 2.28 ane $0.92^{\circ}C$ between rectum and gluteus or jugular groove using thermometer II. The difference of mean temperature in swine between rectum and flank, inguinal region, and neck were 1.23, 0.21, and $0.8^{\circ}C$, respectively, using thermometer I, whereas 1.42, 0.711, and $1.25^{\circ}C$ using thermometer II The difference of mean temperature in goats between rectum and lateral abdomen and inguinal region were 1.02 and $0.12^{\circ}C$, respectively, using thermometer I, whereas 1.96 and $1.01^{\circ}C$ using thermometer II. The difference of mean temperature in dogs between rectum and lateral abdomen, inguinal region, and neck were 3.26, 0.24, and $2.37^{\circ}C$, respectively, using thermometer I, whereas 3.45, 0.56, and $2.61^{\circ}C$ using thermometer II.

저장온도에 따른 돼지 막창의 품질 (Quality Characteristics of Pork Rectum according to Storage Temperature)

  • 오남궁;정재현;최웅규
    • 한국식품영양학회지
    • /
    • 제26권3호
    • /
    • pp.339-344
    • /
    • 2013
  • 신선한 암퇘지 막창부위의 지방을 제거하고, 분쇄기로 잘게 파쇄하여 가열하지 않은 것과 $100^{\circ}C$의 autoclave에서 10분간 가열한 것으로 나누어 polyethylene film으로 1차 포장한 후 알루미늄 호일로 2차 포장한 다음, 각각 $1^{\circ}C$, $5^{\circ}C$$10^{\circ}C$에서 보관하면서 품질 변화를 관찰하였다. 저장 온도를 달리한 파쇄막창의 pH는 6.5~7.0의 범위를 나타내었으며 생막창에 비해 가열막창에서 다소 높게 나타났다. 저장 중 TBA가는 가열막창이 생막창보다 높은 값을 나타내었으며, $10^{\circ}C$ 저장에서는 4일 이후 급격히 증가하였다. $5^{\circ}C$ 저장에서는 생막창의 경우 8일 이후, 가열막창은 6일 이후에 급격한 상승을 보인 것으로 확인되었다. VBN값을 기준으로 볼 때 생막창의 경우 $10^{\circ}C$에서 저장할 경우 8일, $5^{\circ}C$에서 저장할 경우 12일, $1^{\circ}C$에서 저장할 경우 16일까지는 저장이 가능한 것으로 나타났으며, 가열한 막창의 경우 $10^{\circ}C$에서 8일, $5^{\circ}C$에서 14일, $1^{\circ}C$에서 16일까지 저장이 가능한 것으로 나타났다. 위의 결과를 바탕으로 막창을 $10^{\circ}C$에서 냉장 유통할 경우 6일 이내의 유통기간 설정이 바람직할 것으로 판단된다. 또한, 대장균군의 사멸과 중온균과 호냉성 균의 효율적인 억제를 위해서는 막창을 $100^{\circ}C$에서 20분 동안 가열하는 것이 바람직할 것으로 판단된다.

매실의 첨가가 돼지 막창의 저장특성에 미치는 영향 (Changes in Quality Characteristics of Pork Rectum by Addition of Maesil (Prunus mume Sieb. et Zucc.))

  • 오남궁;정재현;최웅규
    • 한국식품영양학회지
    • /
    • 제26권3호
    • /
    • pp.453-458
    • /
    • 2013
  • 본 연구에서는 매실의 첨가에 따른 돼지막창의 품질특성 변화를 확인하였다. 가열하지 않은 막창(생막창)과 $100^{\circ}C$에서 10분 동안 가열한 막창(가열막창)의 pH는 매실의 첨가에 따라 낮아졌다. L값과 a값은 생막창과 가열막창 모두 저장기간에 따른 변화는 미미한 것으로 확인되었다. 생막창의 b값은 저장 초기에는 매실의 첨가에 따른 상승이 확연하였으나, 저장기간이 지속됨에 따라 그 차이가 점점 줄어들었다. 가열막창의 b값은 매실의 첨가에 따른 b값이 약간 낮아졌으며, 저장기간에 따라 약간 감소하는 경향을 나타내었다. ${\delta}T$ 값은 생막창과 가열막창 모두 L값과 거의 유사한 패턴을 보였다. 생막창과 가열막창 모두에서 TBA가는 매실의 첨가농도에 비례하여 유의적으로 낮아졌으며, 매실 5% 첨가구와 10% 첨가구는 거의 TBA가에서 차이가 없었다는 것으로 확인되었다. VBN가는 매실을 첨가할 경우 생막창과 가열막창 모두에서 VBN의 증가속도는 대조구에 비해서 낮은 것으로 확인되었다. 저장 6일째부터 매실의 첨가농도에 비례하여 VBN가가 낮아졌으며, 매실을 5% 첨가할 경우 저장을 4일 이상 지연시킬 수 있는 것으로 확인되었다.

Sodium-5-Methoxy Salicylate의 흡수촉진 효과에 관한 연구 (A Study on the Absorption-Enhancing Effect of Sodium-5-methoxysalicylate)

  • 김기헌
    • 약학회지
    • /
    • 제29권3호
    • /
    • pp.111-116
    • /
    • 1985
  • Effect of sodium-5-methoxysalicyclate (5MSA-Na) on the absorption of cefmetazol (CMZ) was studied in rectum and duodenum of rats via in situ loop method. Effect of 5MSA-Na on the absorption of CMZ showed markedly different results in rectum and duodenu. Penetration of 5MSA-Na was greater in rectum than in duodenum and water-transfer was markedly increased in duodenum.

  • PDF

CT Based 3-Dimensional Treatment Planning of Intracavitary Brachytherapy for Cancer of the Cervix : Comparison between Dose-Volume Histograms and ICRU Point Doses to the Rectum and Bladder

  • Hashim, Natasha;Jamalludin, Zulaikha;Ung, Ngie Min;Ho, Gwo Fuang;Malik, Rozita Abdul;Ee Phua, Vincent Chee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권13호
    • /
    • pp.5259-5264
    • /
    • 2014
  • Background: CT based brachytherapy allows 3-dimensional (3D) assessment of organs at risk (OAR) doses with dose volume histograms (DVHs). The purpose of this study was to compare computed tomography (CT) based volumetric calculations and International Commission on Radiation Units and Measurements (ICRU) reference-point estimates of radiation doses to the bladder and rectum in patients with carcinoma of the cervix treated with high-dose-rate (HDR) intracavitary brachytherapy (ICBT). Materials and Methods: Between March 2011 and May 2012, 20 patients were treated with 55 fractions of brachytherapy using tandem and ovoids and underwent post-implant CT scans. The external beam radiotherapy (EBRT) dose was 48.6Gy in 27 fractions. HDR brachytherapy was delivered to a dose of 21 Gy in three fractions. The ICRU bladder and rectum point doses along with 4 additional rectal points were recorded. The maximum dose ($D_{Max}$) to rectum was the highest recorded dose at one of these five points. Using the HDRplus 2.6 brachyhtherapy treatment planning system, the bladder and rectum were retrospectively contoured on the 55 CT datasets. The DVHs for rectum and bladder were calculated and the minimum doses to the highest irradiated 2cc area of rectum and bladder were recorded ($D_{2cc}$) for all individual fractions. The mean $D_{2cc}$ of rectum was compared to the means of ICRU rectal point and rectal $D_{Max}$ using the Student's t-test. The mean $D_{2cc}$ of bladder was compared with the mean ICRU bladder point using the same statistical test. The total dose, combining EBRT and HDR brachytherapy, were biologically normalized to the conventional 2 Gy/fraction using the linear-quadratic model. (${\alpha}/{\beta}$ value of 10 Gy for target, 3 Gy for organs at risk). Results: The total prescribed dose was $77.5Gy{\alpha}/{\beta}10$. The mean dose to the rectum was $4.58{\pm}1.22Gy$ for $D_{2cc}$, $3.76{\pm}0.65Gy$ at $D_{ICRU}$ and $4.75{\pm}1.01Gy$ at $D_{Max}$. The mean rectal $D_{2cc}$ dose differed significantly from the mean dose calculated at the ICRU reference point (p<0.005); the mean difference was 0.82 Gy (0.48-1.19Gy). The mean EQD2 was $68.52{\pm}7.24Gy_{{\alpha}/{\beta}3}$ for $D_{2cc}$, $61.71{\pm}2.77Gy_{{\alpha}/{\beta}3}$ at $D_{ICRU}$ and $69.24{\pm}6.02Gy_{{\alpha}/{\beta}3}$ at $D_{Max}$. The mean ratio of $D_{2cc}$ rectum to $D_{ICRU}$ rectum was 1.25 and the mean ratio of $D_{2cc}$ rectum to $D_{Max}$ rectum was 0.98 for all individual fractions. The mean dose to the bladder was $6.00{\pm}1.90Gy$ for $D_{2cc}$ and $5.10{\pm}2.03Gy$ at $D_{ICRU}$. However, the mean $D_{2cc}$ dose did not differ significantly from the mean dose calculated at the ICRU reference point (p=0.307); the mean difference was 0.90 Gy (0.49-1.25Gy). The mean EQD2 was $81.85{\pm}13.03Gy_{{\alpha}/{\beta}3}$ for $D_{2cc}$ and $74.11{\pm}19.39Gy_{{\alpha}/{\beta}3}$ at $D_{ICRU}$. The mean ratio of $D_{2cc}$ bladder to $D_{ICRU}$ bladder was 1.24. In the majority of applications, the maximum dose point was not the ICRU point. On average, the rectum received 77% and bladder received 92% of the prescribed dose. Conclusions: OARs doses assessed by DVH criteria were higher than ICRU point doses. Our data suggest that the estimated dose to the ICRU bladder point may be a reasonable surrogate for the $D_{2cc}$ and rectal $D_{Max}$ for $D_{2cc}$. However, the dose to the ICRU rectal point does not appear to be a reasonable surrogate for the $D_{2cc}$.

생강의 첨가가 분쇄막창의 저장특성에 미치는 영향 (Changes in Storage Characteristics of Pork Rectum by Addition of Ginger (Zingiber officinale Roscoe))

  • 최원석;최웅규
    • 한국식품영양학회지
    • /
    • 제27권5호
    • /
    • pp.956-961
    • /
    • 2014
  • 신선한 암퇘지의 막창부위에 지방을 제거하고 파쇄기로 잘게 부수어 가열하지 않은 것과 $100^{\circ}C$의 autoclave에서 10분간 가열한 것에 분쇄한 생강을 1, 5 및 10%가 되게 첨가하여 polyethylene film으로 1차 포장한 후 알루미늄 호일로 2차 포장한 다음 $5^{\circ}C$에서 보관하면서 품질의 변화를 관찰하였다. 저장 중 pH는 첨가구 사이의 유의적인 차이를 나타내지 않았으나, 가열한 막창이 다소 낮은 값을 나타내었다. TBA가는 각각 0.1 mg/kg과 0.25 mg/kg으로 가열 막창이 생막창보다 높은 값을 나타내었으며, 두 처리구에서 모두 생강의 첨가가 TBA-value의 상승을 억제시켜 저장성을 연장시키는 것을 확인할 수 있었다. 휘발성 염기질소의 함량은 생강의 첨가로 감소하였으며, 30~40 mg%의 초기부패 판정기준을 고려할 때 생막창은 $5^{\circ}C$에서 4일, 가열막창은 6일 이내에 소비하는 것이 바람직할 것으로 판단되었다. VBN 함량을 기준으로 10% 생강의 첨가는 가열막창의 저장기간을 4일 가량 연장시킬 수 있는 것으로 확인되었다.

골반 림프선을 포함한 전립선암 치료 시 Split VMAT plan의 유용성 평가 (Evaluating efficiency of Split VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes)

  • 문준기;손상준;김대호;서석진
    • 대한방사선치료학회지
    • /
    • 제27권2호
    • /
    • pp.145-156
    • /
    • 2015
  • 목 적 : 골반 림프선을 포함한 전립선암 치료 시 기존 치료방법인 직장 전체를 윤곽 그리기한 2회전 치료계획(이하 Conventional VMAT plan)과 직장의 선량을 낮추기 위하여 상부와 하부로 나누어 윤곽 그리기한 2회전 치료계획(이하 Split VMAT plan)의 유용성을 비교, 평가하고자 한다. 대상 및 방법 : 본원에서 TrueBeam STX(Varian Medical Systems, USA)를 이용하여, Split VMAT plan으로 방사선치료를 받은 전립선암 환자 9명을 대상으로 하였다. 전산화치료계획은 Eclipse(Ver 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver 10.0.28) 알고리즘을 사용하였다. 전립선 PTV의 Superior 방향으로 1 cm부터 Inferior방향으로 1 cm까지를 하부 직장으로, 전체 직장에서 직장 하부를 제외한 부분을 상부 직장으로 윤곽 그리기(Contouring) 하였다. 치료계획은 콜리메이터 각도 $30^{\circ}$, $330^{\circ}$, 겐트리 회전반경이 각각 $360^{\circ}$인 두 개의 ARC, 10MV를 이용하였다. 처방 선량은 28회에 걸쳐 동시 추가 분할 선량법(Simultaneous Integrated Boost, SIB)으로 전립선에 총 선량이 각각 63~70 Gy, 골반 림프선에 총 선량이 50.4 Gy가 되도록 하였다. Split VMAT plan을 통해 도출된 전체 직장의 $D_{mean}$를 Conventional VMAT plan에서 전체 직장의 선량용적제한 값으로 설정하여 Conventional VMAT plan을 수립하였고, 그 외에 모든 조건은 동일하게 설정하였다. 모든 치료계획은 최적화 과정에서 나타나는 선량 차이의 무작위성을 최소화하기 위하여 각각 2회의 최적화와 선량 계산 과정을 거쳤으며 전립선 PTV100% = 90% 또는 95%로 Normalize 하였다. 전체 상부 하부 직장의 평균선량, 방광의 평균선량, 상부 직장의 $V_{50%}$, 각 치료 계획의 Total MU, 그리고 PTV의 H.I.(Homogeneity Index), C.I.(Conformity Index)를 평가 지표로 설정하였고, 전자영상유도장치를 이용하여 임상 적용 가능 여부 확인을 위한 IMRT verification QA(Gamma test)를 실시하였다. 결 과 : 두 치료계획의 평균선량을 비교한 결과 전체 직장은 최대 134.4 cGy, 최소 43.5 cGy, 평균 75.6 cGy로, 하부 직장은 최대 100.5 cGy, 최소 -34.6 cGy, 평균 34.3 cGy로, 상부 직장 은 최대 1113.5 cGy, 최소 87.2 cGy, 평균 550.5 cGy로, 방광은 최대 271 cGy, 최소 -55.5 cGy, 평균 117.8 cGy로 모두 Split VMAT plan이 낮은 값을 보였다. 상부 직장의 V50%도 최대 63.4%, 최소 3.2%, 평균 23.2%로 Split VMAT plan이 낮은 것으로 나타났다. Total MU는 Split VMAT plan이 최대 148, 최소 7로, 평균 77 더 많이 사용하는 것으로 나타났다. PTV에 대한 H.I.와 C.I.는 두 치료계획 모두 서로 비슷한 결과를 나타냈다. Split VMAT plan에 대한 IMRT verification QA 결과 2 mm / 2%, Gamma pass rate 90.0% 기준을 모두 통과하였다. 결 론 : 골반 림프선을 포함한 전립선암 치료 시 Split VMAT plan은 Conventional VMAT plan과 비교하여 대부분의 평가지표에서 유리한 것으로 나타냈으며 치료효율을 높이면서 특히 상부 직장 선량을 감소시켜 전체 직장 선량을 낮추는데 탁월한 효과를 나타냈기 때문에 이를 적용시켜 방사선 치료효과를 높이는 것이 중요할 것이라 사료된다.

  • PDF

고선량률 강내 근접치료시 열형광량계를 이용한 선량측정법 (TLD Dosimetry in HDR Intracavitary Brachytherapy)

  • Kim, Chang-Seon;Yang, Dae-Sik;Kim, Chul-Yong;Park, Myung-Sun
    • 한국의학물리학회지:의학물리
    • /
    • 제11권2호
    • /
    • pp.109-116
    • /
    • 2000
  • 자궁경부암 환자의 방사선 조사시 고려하여야 할 사항 중 한가지는 결정 장기인 방광 및 직장의 부작용이다. 강내 고선량률 근접 치료시 방광과 직장의 흡수선량을 열형광량계 선량측정법을 이용하여 간접적으로 측정하였다 방광 및 직장의 부작용을 줄일 수 있는 방법이 제안되었다. 방사선 치료 후 예후관찰 중인 200명의 자궁경부암 환자의 자기공명 영상에서 자궁경부의 중심축에서 방광 및 직장 그리고 자궁벽의 두께를 측정하였다. 밀봉시킨 열형광량계를 오보이드의 팩킹거즈 위에 놓고 씨물레이션 필름 상에서 오보이드의 중심에서부터의 거리를 측정한 후 실제의 방광과 직장의 흡수선량을 계산하였다. 발표된 연구결과들에서 방광 및 직장의 최대 견딤선량을 계산하였고 고선량률 근접치료 1회당의 허용선량을 토대로 양방향의 팩킹두께를 알아냈다 방광과 직장방향의 최소의 팩킹두께는 각각 0.43 과 0.92 cm 이었다. 이 결과를 마이스버거 다항식을 이용한 계산결과와 비교하였다. 본 연구에서 제시한 방법이 임상에서 고선량률 근접 치료시 방광과 직장 같은 결정장기의 흡수선량을 평가하는 방법으로 사용되기를 바란다.

  • PDF

RALS시행시 선원의 거리 이동및 직장선량에 관한 계산치와 측정치의 비교연구 (Dose Distribution of Rectum in the treatment of Uterine Cervical Cancer using Remote Afterloading System)

  • 김성규;신세원;김명세
    • 한국의학물리학회지:의학물리
    • /
    • 제5권1호
    • /
    • pp.67-74
    • /
    • 1994
  • 선량분포특성은 거리의 제곱에 반비례하기 때문에 근접조사에서 선원의 조그마한 오차는 선량계산에서 큰 차이를 초래할 수 있어서 선원의 정확한 거리 이동과 그에 따른 critical organ에 조사되는 선량의 정확도는 자궁경부암 환자의 치료성적에 결정적인 역할을 할 수가 있다. 특히 High Dose Rate의 RALS(Remote After Loading System)에서 선원의 정확한 calibration은 자궁경부암 환자의 치료에서 선량분포에 지대한 영향을 미치며 나아가 이 선량분포는 치료후 나타나는 재발 및 합병증이나 휴유증의 발생에도 큰 영향을 미치게 된다. 본 연구에서는 실제 RALS시 선원의 거리 이동을 측정하여 치료계획용 computer에서 계산된 선원간의 거리 이동과 비교 검토하였으며 Rectum 위치에 chamber를 삽입하여 실제 Rectum에 조사되는 선량과 computer에서 계산된 값들을 비교검토하였다. Tandem Source을 1cm 간격으로 거리를 이동하면서 실험을 되풀이 한 결과 처음 monitor로 1cm을 이동할 때 측정치가 0.8cm 이동한 것으로 나타났으며, 2번째부터 5번째까지의 거리 이동에서는 monitor의 값과 측정치의 값이 정확하게 일치하였다. 또한 12명의 환자를 대상으로 실시한 Rectum dose의 측정치는 computer계산치보다 평균 8%로 낮게 나타났다.

  • PDF

Sodium 5-Methoxy Salicylate의 흡수촉진 효과에 관한 연구 (II). 흡수촉진제에 대한 반응성 (A Study on the Absorption Enhancing Effect of Sodium 5-Methoxysalicylate(II))

  • 김기헌
    • 약학회지
    • /
    • 제30권2호
    • /
    • pp.96-99
    • /
    • 1986
  • Absorption enhancing effect of 5 MSA-Na at the mucous memberanes of the rectum and duodenum was studied via in vitro sac test. There were no significant differences between two membranes. Effect of 5MSA-Na on the transfer of CMZ to the tissue was also studied via in situ loop method. There was no significant difference at the duodenum, compared to the control when CMZ was administered intravenously. Transfer of CMZ to the loop of the rectum was increased in the presence of 5MSA-Na compared to the control, which might be attributed to the enhanced permeability of the mucous memberane of the rectum.

  • PDF