• Title/Summary/Keyword: rectangular beams

Search Result 213, Processing Time 0.025 seconds

An Experimental Study on Reinforcing Efficiency of H-Shaped Steel Beams with a Rectangular Web Opening (유공 H 형강보의 보강효율에 관한 실험적 연구)

  • Kim, Jin-Mu;Cho, Chul-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.1
    • /
    • pp.171-178
    • /
    • 1999
  • Despite of decrease in shear and moment strengths, most steel structural designers use web openings in beams because of economical benefit and requirement. The purpose of this study is to suggest the method of reinforcement of H-shape steel beams with a rectangular web opening. If shear predominates over bending, it is necessary to consider all possible combinations of shear force and bending moment acting at the opening. In this paper, the ultimate strength and behavior of perforated beams have been investigated according to parameters (ratio of M/V, opening width within opening height ratio D/h, various reinforcing types A/B/C/D/M/N/W). The results of this study are as follows ; 1. Deformation of H-shape steel beams with a rectangular web opening was greatly affected by not only bending but also shear. 2. SB1-2/3 series have little difference in the reinforced efficiency, but SB1-2E/3E series have difference in the reinforced efficiency according to the reinforcement type. 3. Efficiency of SB1-2E/3E series is determined by reinforcing types, which RB1-2E-B/M/C and RB1-3E-M/D/C specimens have good efficient. Reinforcing type of perforated beams chooses efficient method according to ratio of M/V and D/h.

  • PDF

Comparison on the Behaviors of Inverted Tee and Rectangular Precast Prestressed Concrete Beams Under Combined Bending and Torsion (휨과 비틀림을 받는 프리캐스트 PSC 역T형 보와 직사각형 보의 거동 비교)

  • Seol Dong-Jae;Park Sang-Yeol;Yu Sung-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.6 s.84
    • /
    • pp.733-740
    • /
    • 2004
  • This study presents the behaviors of the typical architectural precast prestressed concrete beams, inverted tee and rectangular beams, subjected to combined flexural and torsional loads. For this purpose, two inverted-tee beams were designed with a parking live load, $5 kN/m^2$, and a market load $12 kN/m^2$ according to the currently used typical shape in the domestic building site. Also, two rectangular beams were also designed as the same bottom dimension and area, and reinforced for similar strength as in the cases of inverted tee beams. Total of four beams were tested, under combined bending and torsion, analysed and compared. Test results showed that the cracking and ultimate flexural strength of the beams decreased under torsional loading. However, two different shaped-beams had roughly the same load resisting capacity in service and ultimate states.

Cyclic Vehavior of composite Beams with Double-Circular Web Openings (쌍원형 개구부를 가진 합성보의 이력거동)

  • 김원기
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.162-169
    • /
    • 1999
  • Intentionally weakened girders near the beam-to-colum connection lead ductile failures at the weakened points prior to potential brittle failure at the connection points subjected to strong earthquake. Recent research investigated cyclic behavior of composite beams with a rectangular web opening and find out ductile failure of such beams due to plastic hinge formation of T-section at the four corners of the rectangular opening. But eventual failures of T-sections are resulted from local buckling of T-section having a narrow stem and a narrow bound of plastic hinge formation. This continuing research proposes double-circular opening instead of rectangular one in ofter to improve energy dissipation capacity as well as composite beam strength, Experimental test of two specimens was carried out and its results are compared with those of nonlinear finite element analyses

  • PDF

On Shear Capacity of Reinforced Concrete Deep Beams with Rectangular Web Openings

  • Eun, Hee Chang;Yang, Keun Hyeok;Lee, Young Ho;Chung, Heon Soo
    • Architectural research
    • /
    • v.7 no.2
    • /
    • pp.55-60
    • /
    • 2005
  • Based on an experimental study, this study provides an equation to describe the shear strength of high-strength concrete deep beams with rectangular openings and without web reinforcements. Twenty-four concrete deep beams were tested with the variables of concrete strength, size of web opening, and shear span-to-depth ratio. The proposed equation is expressed as the sum of the shear strength provided by longitudinal bars and concrete. It is illustrated that the proposed equation predicts the load-carrying capacity of the deep beams more properly than the experimental equations proposed by other researchers.

An initial investigation of the inverted trussed beam formed by wooden rectangular cross section enlaced with wire rope

  • Gesualdo, F.A.R.;Lima, M.C.V.
    • Structural Engineering and Mechanics
    • /
    • v.44 no.2
    • /
    • pp.239-255
    • /
    • 2012
  • This work presents a contribution to understand the inverted trussed beams behavior. The system has a main beam and struts with rectangular cross section associated to a wire rope enlaced to the main beam. It is an unpublished system with the advantage of easy positioning of the wire rope, once it is a continuous and connected by turnbuckles. It is a system that can be used as support for concrete formworks or for rehabilitation wooden beams proposal. The enlacement of the cable demands a small notch at the top of the cross section and a cross pin at the bottom. Six inverted trussed beams were tested, with spans of 180 cm with cables diameter of 1/4". Additionally, four simple beams without any external steel cable were also tested with material from the same lot of wood, allowing a comparison in rupture. The results showed capacity gain of around 60% compared to a simple beam. Once the wire rope characteristics and anchoring are very important for structure response, some improvement suggestions for the efficiency of the cables are also presented.

Shear strengthening of reinforced concrete beams with rectangular web openings by FRP Composites

  • Abdel-Kareem, Ahmed H.
    • Advances in concrete construction
    • /
    • v.2 no.4
    • /
    • pp.281-300
    • /
    • 2014
  • This study presents the experimental results of twenty three reinforced concrete beams with rectangular web openings externally strengthened with Fiber Reinforced Polymers (FRP) composites bonded around openings. All tested beams had the same geometry and reinforcement details. At openings locations, the stirrups intercepted the openings were cut during fabrication of reinforcement cage to simulate the condition of inclusion of an opening in an existing beam. Several design parameters are considered including the opening dimensions and location in the shear zone, the wrapping configurations, and the amount and the type of the FRP composites in the vicinity of the openings. The wrapping configurations of FRP included: sheets, strips, U-shape strips, and U-shape strips with bundles of FRP strands placed at the top and sides of the beam forming a fan under the strips to achieve closed wrapping. The effect of these parameters on the failure modes, the ultimate load, and the beam stiffness were investigated. The shear contribution of FRP on the shear capacity of tested beams with web openings was estimated according to ACI Committee 440-08, Canadian Standards S6-06, and Khalifa et al. model and examined against the test results. A modification factor to account for the dimensions of opening chords was applied to the predicted gain in the shear capacity according to ACI 440-08 and CSA S6-06 for bonded Glass Fiber Reinforced Polymers (GFRP) around openings. The analytical results after incorporating the modification factor into the codes guidelines showed good agreement with the test results.

Shape optimization of steel reinforced concrete beams

  • Babu Narayan, K.S.;Venkataramana, Katta
    • Computers and Concrete
    • /
    • v.4 no.4
    • /
    • pp.317-330
    • /
    • 2007
  • Steel reinforced concrete is perhaps the most versatile and widely used construction material. The versatility is attributed to mouldability of concrete to any conceivable shape. The inherent property of cracking of concrete is the reason for its low tensile strength and hence the design approach of RCC sections in flexure adopts the cracked section theory where in concrete in tension zone is ignored. Means, modes and methods of exploitation of concrete strength by conceiving shapes other than rectangular whereby ineffective concrete in tension zone is reduced and incorporated in compression zone where it is effective needs consideration. Shape optimization of beams is attempted in this analytical investigation employing Sequential Unconstrained Minimization Technique (SUMT). The results clearly show that trapezoidal beams happen to be less costlier than their rectangular counterparts, their usage needs serious reconsideration by the designers.

An Influence of Rectangular Openings on the Structural Behavior in Reinforced Concrete Deep Beams (철근콘크리트 깊은 보의 구조적 거동에 대한 장방형 개구부의 영향)

  • Yang Keun-Hyeok;Chung Heon-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.395-398
    • /
    • 2005
  • To understand an influence of rectangular openings on the structural behavior in reinforced concrete deep beams, results of 52 specimens were analyzed. The structural behavior such as load-deflection relationship, load-maximum crack width relationship, and maximum strength was significantly affected by inclination of concrete strut beneath opening.

  • PDF

Flexural Strength of cold-formed steel built-up composite beams with rectangular compression flanges

  • Dar, M. Adil;Subramanian, N.;Dar, Dawood A.;Dar, A.R.;Anbarasu, M.;Lim, James B.P.;Mahjoubi, Soroush
    • Steel and Composite Structures
    • /
    • v.34 no.2
    • /
    • pp.171-188
    • /
    • 2020
  • The past research on cold-formed steel (CFS) flexural members have proved that rectangular hollow flanged sections perform better than conventional I-sections due to their higher torsional rigidity over the later ones. However, CFS members are vulnerable to local buckling, substantially due to their thin-walled features. The use of packing, such as firmly connected timber planks, to the flanges of conventional CFS lipped I-sections can drastically improve their flexural performance as well as structural efficiency. Whilst several CFS composites have been developed so far, only limited packing materials have been tried. This paper presents a series of tests carried out on different rectangular hollow compression flanged sections with innovative packing materials. Four-point flexural tests were carried out to assess the flexural capacity, failure modes and deformed shapes of the CFS composite beam specimens. The geometric imperfections were measured and reported. The North American Specifications and Indian Standard for cold-formed steel structures were used to compare the design strengths of the experimental specimen. The test results indicate clearly that CFS rectangular 'compression' flanged composite beams perform significantly better than the conventional rectangular hollow flanged CFS sections.

Development of a Six-Axis Force/Moment Sensor with Rectangular Taper Beams for an Intelligent Robot

  • Kim, Gab-Soon
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.4
    • /
    • pp.419-428
    • /
    • 2007
  • This paper describes the development of a six-axis force/moment sensor with rectangular taper beams for an intelligent robot's wrist and ankle. In order to accurately push and pull an object with an intelligent robot's hand, and in order to safely walk with an intelligent robot's foot, the robot's wrist and ankle should measure three forces Fx, Fy, and Fz, and three moments Mx, My, and Mz simultaneously from the mounted six-axis force/moment sensor to the intelligent robot's wrist and ankle. Unfortunately, the developed six-axis force/moment sensor utilized in other industrial fields is not proper for an intelligent robot's wrist and ankle in the size and the rated output of the six-axis force/moment sensor. In this paper, the structure of a six-axis force/moment sensor with rectangular taper beams was newly modeled for an intelligent robot's wrist and ankle, and the sensing elements were designed by using the derived equations, following which the six-axis force/moment sensor was fabricated by attaching strain-gages on the sensing elements. Moreover, the characteristic test of the developed sensor was carried out by using the six-component force/moment sensor testing machine. The rated outputs from the derived equations agree well with those from the experiments. The interference error of the sensor is less than 2.87%.