• 제목/요약/키워드: rectal pressure catheter

검색결과 3건 처리시간 0.017초

휴대용 디지털 요역동학검사장비의 설계와 Calibration (Calibration and Design of amulatory digital urodynamic study system)

  • 윤대영;김거식;서정환;김경섭;송철규;양영광;이상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.313-315
    • /
    • 2004
  • Urodynamic study system is widely used for neurogenic bladder patients in various clinical setting. Generally they include 2 pressure sensors from bladder and rectum, and 1 EMG sensor. The rectal pressure catheter is often the source of data error because of gas passage and the fall out of the catheter from anus, and source of discomfort in ambulatory urodynamic system. This study is to design and calibrate the ambulatory digital urodynamic study system that can discard the rectal pressure catheter, which can make patients more comfortable and doctors can get more physiologic data. As a first step, we compared our new system with Dantec $Duet^{(r)}$ urodynamic system (Dantec, Denmark) and wanted to see the possibility of our new system.

  • PDF

유비쿼터스 기반 휴대용 방광기능 검사 장치 (Portable urodynamics monitoring system based on ubiquitous technology)

  • 김거식;안양수;송철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.43-45
    • /
    • 2007
  • We developed a portable urodynamics monitoring system using personal digital assistance (PDA) and proposed a new method for measuring the abdominal pressure in non invasive mode using surface EMG signals. This system is consisted of a signal conditioning and control module and could measure the vesical, abdominal and detrusor pressure. The result showed a high correlation coefficient between the practical abdominal pressure, using a conventional rectal catheter and the estimated values, by our proposed algorithm (r=0.81). This system should prove a useful tool in the future evaluations of ambulatory urodynamics monitoring study.

  • PDF

휴대용 요역동학 검사 시 근전도 신호를 이용한 복압측정 방법 (A Non-invasive Measurement of Abdominal Pressure on Ambulatory Urodynamics Study Using Surface Electromyography)

  • 김거식;송철규;서정환
    • 전자공학회논문지SC
    • /
    • 제45권6호
    • /
    • pp.132-140
    • /
    • 2008
  • 복압 측정을 위한 기존의 카데터 방법은 배뇨압에 영향을 줄 수 있는 많은 오차를 유발할 수 있으며 환자에게 불편함을 야기한다. 이러한 문제점을 해결하기 위해, 본 연구에서는 표면 근전도를 이용하여 비침습적으로 복압을 측정할 수 있는 새로운 방법을 개발하였다. 연구 결과, 기존 직장 카테터를 이용하여 측정된 복압과 복압측정 알고리즘을 이용하여 추정된 복압 간의 상관계수는 $0.79{\pm}0.06$이었으며, 두 신호간의 오차는 $0.10{\pm}0.07$이었다. 본 연구에서 개발된 복압추정 알고리즘을 이용하면 휴대용 요역동학 검사 시 편리하게 간접적으로 복압을 측정할 수 있을 것으로 생각된다.