Papermill Wastewater Treatment by Indirect aerated Sebmerged Biofilter (간접포기식 침지여상에 의한 제지페수처리)

  • 원찬희
    • Journal of Environmental Science International
    • /
    • v.2 no.2
    • /
    • pp.135-144
    • /
    • 1993
  • The purpose of this experimental research was focused to improve the quality of the effluent and the yielded sludge when the papermill wastewater was treated by the indirect aerated submerged biofilter as a second treatment method of papermill wastewater. Changing the various experimental factors (Nutrient additions or not, HRT, Fh ratio, recirculation ratio, etc) with indirect aerated submerged biofilter, the results are as follows. 1) because of the microbes concentration could be sustained to 9, oho man in submerged biofilter and then the volumetric organic loads could be increased to 2.7 kg-BOD/$m^3$<\TEX>/day, the reactor volume can be reduced. 2) Because of the yield coefficient(Y) and the endogenous decay coefficient(kd) were revealed 0.4 and 0.07/d, the yielded sludge volume was reduced. 3) The concentration of the sloughed sludge in the reactor was 2.62~4.01 %, so the thickener could be omited in the papermill wastewater sludge treatment process. 4) When the operating was conducted at HRT of 4hrs, the treatment efficiencies of BOD and COD were obtained 80% and 70%. 5) The range of the theoretical recirculation ratios of this reactor was 14~26. According to those ratios, at the low loads ( BOD volumetric loads is less than 0.79 kg-BOD/$m^3$<\TEX>/day, FM ratio is less than 2.0/d) the results were fitted to the theoretical recirculation ratios (14 ~26) and at the high loads the efficiency were increased to the rise of recirculation ratios.

  • PDF

A study on the stabilization characteristics of the diffusion flame formed behind a bluff body (Bluff Body 후류에 형성되는 확산화염의 보염특성에 관한 연구)

  • ;;An, Jin-Geun;Song, Kyu-Keun
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.12
    • /
    • pp.3344-3351
    • /
    • 1995
  • The stability of diffusion flame formed behind a bluff body with fuel injection slits was experimentally investigated in various fuel injection angles, fuel injection ratios, grids and extension ducts. The flame stability limits, temperature distributions and length of recirculation zones, direct photographs of flames were measured in order to discuss the stabilization mechanism of the diffusion flame. The results from this study are as follows. The fuel injection angle is an important factor in determining the flame stability. Stability limits can be improved by variety of the fuel injection ratio. When the grid and extension duct are set, stability characteristics are varied with the blockage ratios, grid intervals, and grid numbers. The recirculation zone not only serves as a steady ignition source of combustion stream but also governs the stabilization mechanism.

The Effects of Exhaust Gas Recirculation on Premixed Combustion System (배기가스 재순환 방식이 예혼합 연소시스템에 미치는 영향)

  • Yu, Byeonghun;Lee, Seungro;Kum, Sung-Min;Lee, Chang-Eon
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.1-3
    • /
    • 2013
  • The premixed combustion system applying exhaust gas recirculation was investigated to achieve the low pollutant emission and the high thermal efficiency. In this study, it was studied the effects of EGR on the thermal efficiency, $NO_x$ and CO emissions with various EGR ratios and equivalence ratios. As results, when equivalence ratio was increased, thermal efficiency increased and $NO_x$ and CO concentration increased. When EGR was applied, $NO_x$ and CO concentration decreased and thermal efficiency increased. Especially, in the case of 15% of EGR ratio at 0.85 of equivalence ratio, $NO_x$ and CO concentration will be a smaller than these of a current operating condition of the boiler and thermal efficiency was about 1.7% higher.

  • PDF

The Effects of Obstacle Aspect Ratio on Surrounding Flows (장애물 외관비가 주변 흐름에 미치는 영향)

  • Lee, Jae-Jin
    • Atmosphere
    • /
    • v.17 no.4
    • /
    • pp.381-391
    • /
    • 2007
  • The characteristics of flow around a single obstacle with fixed height and varied length and width are numerically investigated using a computational fluid dynamics (CFD) model. As the obstacle length increases, flow distortion near the upwind side of the obstacle increases and the size of the recirculation zone behind the obstacle also increases. As the obstacle width increases, the size of the recirculation zone decreases, despite almost invariable flow distortion near the upwind side of the obstacle. Flow passing through an obstacle is separated, one part going around the obstacle and the other crossing over the obstacle. The size of the recirculation zone is determined by the distance between the obstacle and the point (reattachment point) at which both the flows converge. When the obstacle width is relatively large, flows are reattached at the obstacle surface and their recoveries occur. Resultant shortening of the paths of flows crossing over and going around decreases the size of the recirculation zone. To support this, the extent of flow distortion defined based on the change in wind direction is analyzed. The result shows that flow distortion is largest near the ground surface and decreases with height. An increase in obstacle length increases the frontal area fraction of flow distortion around the obstacle. In the cases of increasing the width, the frontal area fraction near the upwind side of the obstacle does not change much, but near the downwind side, it becomes larger as the width increases. The frontal area fraction is in a better correlation with the size of the recirculation zone than the building aspect ratios, suggesting that the frontal area fraction is a good indicator for explaining the variation in the size of the recirculation zone with the building aspect ratios.

A Study on the Rotating Biological Contactors for the Nitrification of Sewage (회전원판공정을 이용한 하수의 질산화에 관한 연구)

  • Jung, Kun-jin;Lee, Sang-Soo;Kim, Si-Hyeon;Park, Kyoo-hong
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.2
    • /
    • pp.189-199
    • /
    • 2002
  • Nitrogen, in its various forms, can deplete dissolved oxygen levels in receiving waters, stimulate aquatic growth, exhibit toxicity toward aquatic life and affect the suitability of sewage for reuse. Pilot-scale Rotating Biological Contactor(RBC) experiments were conducted to examine biological nitrification, respectively, of municipal sewage with five different internal recirculation ratios of 0, 1, 2, 3, and 4 using the constant hydraulic loading of $205L/m^2{\cdot}day$. The use of internal recirculation improved nitrification on account of the dilution of biodegradable organic carbon in influent sewage down to 15 mg/L of $SBOD_5$ or less. Ammonium nitrogen of $14.3{\pm}2.4%$ was consumed by cellular assimilation without the occurrence of denitrification. The thickness of biofilm didn't seem effect significantly the nitrification and denitrification. Nitrification with internal recirculation was found to occur using hydraulic loading rate of as high as $205L/m^2{\cdot}day$, which was beyond the generally known values of it.

Stability of premixed double concentric jets flame with a recirculation zone (재순환역을 수반하는 동축분류예혼합화염에 관한 연구)

  • 이등헌일;송규근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.1
    • /
    • pp.145-153
    • /
    • 1987
  • Stability limits of a double concentric jets flame and the structure of recirculation zone formed behind a thick burner rim were investigated. To control the flame stability, swirled secondary air flow ranging 0.13-0.71 of swirl number, and air, fuel, and mixture gas injection from an injection coaxial slit set on burner rim were examined. Flame stability limits, flame shapes, lengths of recirculation zone, temperature distributions, residence times, air ratios in the recirculation zone were measured. The following results were obtained. (1) Lean limits were considerably widened by a strong swirl because the recirculation zone was enlarged. (2) At fuel injection as well as mixture injection, lean limits were also extended. But, air injection had no effect on stability limits. (3) Injected gas seems to diffuse into the recirculation zone through its outer boundary surrounded the secondary air. Therefore, chemical structure in the recirculation zone with air injection coincides with that without injection. (4) Injection position had no effect on flame stability limits.

Simultaneous Carbon and Nitrogen Removal Using an Integrated System of High-Rate Anaerobic Reactor and Aerobic Biofilter (고효율 혐기성반응조 및 호기성여상 조합시스템에 의한 질소·유기물 동시 제거)

  • Sung, Moon Sung;Chang, Duk;Seo, Seong Cheol;Chung, Bo Rim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.2
    • /
    • pp.55-65
    • /
    • 1999
  • AF(anaerobic filter)/BAF(biological aerated filter) system and UASB(upflow anaerobic sludge blanket)/BAF system, of which system effluents were recirculated to the anaerobic reactors in each system, were operated in order to investigate the performance in simultaneous removal of organics and nitrogen in high-strength dairy wastewater. Advanced anaerobic treatment processes of AF and UASB were evaluated on applicability as pre-denitrification reactors, and BAF was also evaluated on the performance in oxidizing the remaining organics and ammonia nitrogen. At system HRTs of 4.0 to 4.5 days and recirculation ratios of one to three, the AF/BAF system could achieve more than 99% of organics removals and 64 to 78% of total nitrogen removals depending upon the recirculation ratio. Although the UASB/BAF system also showed more than 99% of organics removals, total nitrogen removals in the UASB/BAF system were 53 to 66% which are lower than those in the AF/BAF system at the corresponding recirculation ratios. Optimum recirculation ratios considering simultaneous removal of organics and nitrogen and cost-effectiveness, were in the range of two to three. The upflow AF packed with crossflow module media, as a primary treatment of the anaerobic reactor/BAF system, showed better performances in denitrification, SS removals, and gas production than the UASB. Higher loading rate of suspended solids from the UASB increased the backwashing times in the following BAF. Especially, at a recirculation ratio of three in the UASB/BAF system, the increase in head loss due to clogging in the BAF caused frequent backwashing, at least once d day. The BAF showed the high nitrification efficiency of average 99.2% and organics removals more than 90% at organics loading rate less than $1.4KgCOD/m^3/d$ and $COD/NH_3-N$ ratio less than 6.4. It was proved that the simplified anaerobic reactor/BAF system could maximize the organics removal and achieve high nitrogen removal efficiencies through recirculation of system effluents to the anaerobic reactor. The AF/BAF system can, especially, be a cost effective and competitive alternative for the simultaneous removal of organics ana nitrogen from wastewaters.

  • PDF

Flow comparison between Stenosed Coronary and Abdominal Arteries (협착된 관상동맥과 복부 대동맥의 유동 특성 비교)

  • Kim, M.C.;Lee, C.S.;Kim, C.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.585-590
    • /
    • 2001
  • The hemodynamic characteristics were compared using commercial CFD code for the stenosed coronary and abdominal arteries. Numerical calculations were carried out in the axisymmetric arteries over the stenotic diameter ratios ranging from 0.25 to 0.875 (6 cases) employing the typical physiological flow conditions. In case of the coronary artery, there was only one recirculation zone observed distal to the stenosis throat during the major portion of the period. However, in case of the abdominal aorta, there were complex recirculation regions found proximal and distal to stenosis throat. For both models, the wall shear stresses(WSS) increased sharply in the converging stenosis, reaching a peak just upstream of the throat, and became negative or low values in the post-stenotic recirculation region. As the results, the oscillatory shear index(OSI) was abruptly increased at the stenosis throat. For the coronary stenosis model, the second peak in the OSI was observed distal to the stenosis. The distance between the first peak and the second peak was increased as the degree of the stenosis was raised. On the orther hand, the abdominal stenosis model showed a complex oscillatory behavior in the OSI index and did not showed such a strong second peak. As the degree of stenosis was increased, recirculation regions of the both arteries were extended much longer and flow pattern became more complex.

  • PDF

The Pollutant Emission Characteristics of Lean-Rich Combustion System with Exhaust Gas Recirculation (배기가스 재순환을 적용한 희박-과농 연소시스템의 공해물질 배출특성 연구)

  • Oh, Wheesung;Lee, Chang-Eon;Yu, Byeonghun
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.2
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, the CH4/air lean-rich combustion system with exhaust gas recirculation (EGR) was investigated to explore the potential for lowering pollutant emissions. To achieve this purpose, experiments of lean-rich combustion system with EGR were conducted to measure the changes in the characteristics of the pollutant emission and flame shape with various equivalence ratios and EGR rates. Here, this study was applied to the fuel distribution ratio of 3:1 for the formation of the lean and rich flames. Additionally, the results were compared with $CH_4$/air lean premixed combustion system. The results show that flame shape of lean-rich combustion system was determined by lean and rich equivalence ratios (${\Phi}_L$ and ${\Phi}_R$) and stratified flame was formed with increasing ${\Phi}_R$. According to the pollutant emission characteristics based on experimental results, the NOx and CO emission index (EINOx and EICO) decreased with increasing EGR rate. Especially, in the range needed to form a stable flame, the reduction rates of EINOx and EICO were approximately 47% and 48% for an EGR rate of 25%, global equivalence ratio of 0.85 and ${\Phi}_L$ of 0.80 compared with lean premixed combustion system (${\Phi}$ = 0.78).

An Experimental Study on Flame Structure and Combustion Instability Characteristics in Model Gas Turbine Combustor (모형 가스터빈 연소기에서 화염구조와 연소불안정 특성에 대한 실험적 연구)

  • Park, Sung-Soon;Kim, Min-Ki;Yoon, Ji-Su;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.4
    • /
    • pp.26-34
    • /
    • 2011
  • The present work addresses structural characteristics of natural gas flames in a lean premixed swirl-stabilized combustor with an attention focused on the effect of the formation of recirculation zones on the combustion instability. It is known that the recirculation zone plays an important role in stabilizing a turbulent, premixed natural gas flames by providing a source of heat or radicals to the incoming premixed fuel and air. To improve our understanding of the role of recirculation zones, the flame structure was investigated for various mixture velocities, equivalence ratios and swirl numbers. The optically accessible combustor allowed for the application of laser diagnostics, and Particle Image Velocimetry(PIV) measurements was used to characterize the flame structure under both cold flow conditions and hot flow conditions. Dynamic pressures were also measured to investigate characteristics of combustion at the same time. The results indicates that the formation of recirculation zone is strongly related to the occurrence of thermo-acoustic instabilities.