• Title/Summary/Keyword: receiver function

Search Result 437, Processing Time 0.03 seconds

Camera and Receiver Development for 3D HDTV Broadcasting (3차원 고화질TV 방송용 카메라 및 수신기 개발)

  • 이광순;허남호;안충현
    • Journal of Broadcast Engineering
    • /
    • v.7 no.3
    • /
    • pp.211-218
    • /
    • 2002
  • This paper introduces the HD 3DTV camera and 3DTV receiver that are compatible with the ATSC HDTV broadcasting system. The developed 3DTV camera is based on stereoscopic techniques, and it has control function to control both left and right zoom lens simultaneously and to control the vergence. Moreover, in order to control the vergence manually and to eliminate the synchronization problem of the both images, the 3DTV camera has the 3DTV video multiplexing function to combine the left and right images into the single image. The developed 3DTV signal, and it has the various analog/digital interfaces. The performance of the developed system is confirmed by shooting the selected soccer game in 2002 FIFA KOREA/JAPANTM World Cup and by broadcasting the match. The HD 3DTV camera and receiver will be applied to the 3DTV industries such as 3D movie, 3D game, 3D image processing, 3DTV broadcasting system, and so on.

Reducing PAPR of OFDM Signals Using Modified Partial Transmit Sequences Technique Based on Erasure Decoding (소실 복호 기반의 수정된 PTS 기법을 이용한 OFDM 신호의 PAPR 감소)

  • Kong, Min-Han;Song, Moon-Kyou
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.8C
    • /
    • pp.775-781
    • /
    • 2007
  • In this paper, a modified PTS(Partial Transmit Sequences) technique that uses erasure decoding of RS (Reed-Solomon) codes is presented. At the transmitter, some check symbols in a RS codeword partitioned into subblocks are phase-rotated by phase factors. The receiver decodes received codewords by regarding the phase-rotated check symbols as erasures. Hence, this technique does not need to transmit the side information about the phase factors chosen at the transmitter. The complexity of the receiver is also reduced since the estimation process for the phase factors is not required in the receiver. There is no performance degradation due to the transmission error of the side information or the estimation error of the phase factors. To evaluate the performance of the proposed PTS technique, the CCDF(Complementary Cumulative Distribution Function) of PAPR and the BER(Bit Error Rate) are compared with those of the conventional PTS techniques.

Comparison of the Pediatric Balance Scale and Fullerton Advanced Balance Scale for Predicting Falls in Children With Cerebral Palsy

  • Kim, Gyoung-mo
    • Physical Therapy Korea
    • /
    • v.23 no.4
    • /
    • pp.63-70
    • /
    • 2016
  • Background: The Pediatric Balance Scale (PBS) and the Fullerton Advanced Balance (FAB) scale were used to assess balance function in patients with balance problem. These multidimensional clinical balance scales provide information about potential risk factors for falls. Objects: The purpose of this study was to investigate and compare the predictive properties of the PBS and FAB scales relative to fall risk in children with cerebral palsy (CP) using a receiver operating characteristic analysis. Methods: In total, 49 children with CP (boy=21, girl=28) who were diagnosed with level 1 or 2 according to the Gross Motor Function Classification System participated in this study. The PBS and FAB were performed, and verified cut-off score, sensitivity, specificity, and the area of under the curve (AUC). Results: In this study, the PBS scale was as a predictive measure of fall risk, but the FAB was not significant in children with CP. A cut-off score of 45.5 points provided optimal sensitivity of .90 and specificity of .69 on the PBS, and a cut-off score of 21.5 points provided optimal sensitivity of .90 and specificity of .62 on the FAB. Both scales showed moderately accurate of AUC with .79 and .76, respectively. Conclusion: The PBS is a useful screening tool for predicting fall risk in children with cerebral palsy, and those who score 45.5 or lower indicate a high risk for falls and are in need of balance intervention.

Zigbee based 1-ch ECG device with activity monitoring function (지그비를 기반으로 한 운동감시 기능을 가진 1채널 ECG장치 개발)

  • Hong, Joo-Hyun;Kim, Nam-Jin;Cha, Eun-Jong;Lee, Tae-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.41-43
    • /
    • 2005
  • PDA-based monitoring is used to acquire continuously the patient's vital signs, including electrocardiography, activity, heart rate and $SpO_2$. In this paper, A biomedical signal acquisition device was designed using 3-axial MEMS accelerometer and 1-ch ECG amplifier, to have the function of monitoring activity and electrocardiography. The proposed system is composed of transmitter and receiver. Through the Zigbee communication, subject's biosignals can be transmitted in real-time to receiver, and transmitted data confirmed using PDA. The packet size used in this device was set not to exceed a maximum payload size of 116 byte. One packet consists of two segments. The transmission speed was 21 packet per second, 420 ECG samples per second, and 42 acceleration samples per second. The proposed method can be used to develop Activities of Daily Living(ADL} monitoring devices for the elderly or movement impaired people and enables patients to be monitored without any constraints. Also, this method will reduce medical costs in the aged society.

  • PDF

Performance Analysis of UWB System using S-Function Builder (S-Function Builder를 이용한 UWB 시스템의 성능해석)

  • Lee Sung-Sin;Byon Kun-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.516-521
    • /
    • 2005
  • The application of UWB not only complies with the requirements of remote sensors system(ECG), it also contributes to the effectiveness of the implementations through its unique qualities such as ultra low transmission power - an important factor when dealing with biomedical equipment. In this paper, the aim is to replace the wired ECG sensors with a wireless link and design wireless UWB communication system. The various pulse shapes are presented that satisfies the FCC spectral mask and FCC part 15 rule. It is shown that UWB can be a high rate transmission over short ranges using Rake receiver, with the capability for reliably transmitting 100Mbps over distance at about 10 meters.

Optimal Number of Users in Zero-Forcing Based Multiuser MIMO Systems with Large Number of Antennas

  • Jung, Minchae;Kim, Younsun;Lee, Juho;Choi, Sooyong
    • Journal of Communications and Networks
    • /
    • v.15 no.4
    • /
    • pp.362-369
    • /
    • 2013
  • The optimal number of users achieving the maximum sum throughput is analyzed in zero-forcing (ZF) based multiuser multiple-input multiple-output (MIMO) systems with a large number of base station (BS) antennas. By utilizing deterministic ergodic sum rates for the ZF-beam forming (ZF-BF) and ZF-receiver (ZF-R) with a large number of BS antennas [1], [2], we can obtain the ergodic sum throughputs for the ZF-BF and ZF-R for the uplink and downlink frame structures, respectively. Then, we can also formulate and solve the optimization problems maximizing the ergodic sum throughputs with respect to the number of users. This paper shows that the approximate downlink sum throughput for the ZF-BF is a concave function and the approximate uplink sum throughput for the ZF-R is also a concave function in a feasible range with respect to the number of users. The simulation results verify the analyses and show that the derived numbers of users provide the maximum sum throughputs for the ZF-BF as well as ZF-R in multiuser MIMO systems with a large number of BS antennas.

Crustal Structure under the Taejon(TJN) Station by Receiver Function Methods

  • Yu, Hyeon-Je;Lee, Gi-Hwa
    • Journal of the Korean Geophysical Society
    • /
    • v.4 no.1
    • /
    • pp.35-46
    • /
    • 2001
  • 한반도 중부에 위치한 대전 지진관측소(TJN) 하부의 세부 지각구조를 밝혀내기 위하여 수신함수를 이용한 선형화된 역산(linearized inversion) 방법을 적용하였다. 본 방법의 비단일해(nonuniqueness)와 초기 모델 의존성의 문제를 해결하기 위해 근사 초기 속도 모델로부터 72개의 서로 다른 초기 모델을 구하여 역산을 수행한 후 결과모델들의 평균 속도 모델을 제시하는 방법을 사용하였다. 역산 결과 총 72개의 모델 중 뚜렷한 지각-맨틀 경계를 보이는 43개의 모델만이 조건에 만족하는 결과를 나타내었다. 모든 모델에서 속도 구조는 전체적으로 깊이에 따라 속도의 불연속면이나 급격한 증가없이 연속적인 변화를 하며, 모호면의 깊이는 30~32.5 km의 범위로 나타났다. 평균적인 하부 지각의 속도는 6.5 km/s, 상부 맨틀의 속도는 7.8 km/s로 뚜렷한 속도 변화를 보였다. 결과 모델 군은 중부지각(mid-crust)에서의 속도를 기준으로 약한 저속도층을 나타내는 군과 상대적으로 일정한 속도를 가지는 군으로 구분되었다. 단지 지진파형의 비교만으로 두 모델군 중 합당한 모델군의 선택은 불가능하였다. 따라서 수신 함수를 이용하여 연구 지역의 신뢰할 만한 지각 구조를 구하기 위해서는 그 지역에 대한 지질학적, 지구물리학적 추가정보와의 동반 해석이 요구된다.

  • PDF

Channel Transfer Function estimation based on Delay and Doppler Profiler for 5G System Receiver targeting 500km/h linear motor car

  • Suguru Kuniyoshi;Shiho Oshiro;Gennan Hayashi;Tomohisa Wada
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.5
    • /
    • pp.121-127
    • /
    • 2023
  • A 500 km/h linear motor high speed terrestrial transportation service is planned to launch 2027 in Japan. In order to support 5G service in the train, the Sub-carrier spacing frequency of 30 kHz is planned to be used instead of common 15 kHz sub-carrier spacing to mitigate Doppler effect in such high-speed transportation. In addition, to increase the cell size of 5G mobile system, plural Base Station antenna will transmit the identical Down Link (DL) signal to form the expanded cell size along the train rail. In this situation, forward and backward antenna signals will be Doppler shifted by reverse direction respectively and the receiver in the train might suffer to estimate accurate Channel Transfer Function (CTF) for its demodulation. In this paper, Delay and Doppler Profiler (DDP) based Channel Estimator is proposed and it is successfully implemented in signal processing simulation system. Then the simulated performances are compared with the conventional Time domain linear interpolated estimator. According to the simulation results, QPSK modulation can be used even under severe channel condition such as 500 km/h, 2 path reverse Doppler Shift condition, although QPSK modulation can be used less than 200 km/h with conventional Channel estimator.

Corona generated Radio Interference of the 750 kV AC Bundle Conductors in Sandy and Dusty Weather Condition in the High Altitude Area

  • Liu, Yun-Peng;Zhu, Lei;Lv, Fang-Cheng;Wan, Bao-Quan;Pei, Chun-Ming
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1704-1711
    • /
    • 2014
  • Sandy and dusty weather condition often occurs in the high altitude areas of China, which may greatly influence the corona generated radio interference (RI) characteristics of the bundle conductors of 750 kV AC power transmission lines. Corona generated RI of the conductors of the 750 kV AC power transmission lines used in practice is measured by EMI receiver with a coupling circuit and a coupling capacitor connected between the high voltage side and the earth side in fine and sandy and dusty condition. The measuring frequency is 0.5 MHz, and the quasi-peak detection is used. RI excitation function is calculated based on the corona RI current measured by the EMI receiver. Corona generated RI characteristics were analyzed from sand concentration and sand particle size. The test result shows that the corona generated RI excitation function is influenced by the sandy and dusty condition. Corona discharge of the conductors is more serious in sandy and dusty condition with an ultraviolet (UV) detector. Corona generated RI excitation function increases with the increase of sand concentration and also increases with the increase of particle size.

Realtime Wireless Monitoring of Abnormal ST in ECG Using PC Based System

  • Jeong, Gu-Young;Yu, Kee-Ho;Kim, Nam-Gyun;Inooka, Hikaru
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.176-180
    • /
    • 2004
  • The ST-segment that the beginning part of T wave is the important diagnostic parameter to finding myocardial ischemia. Abnormal ST appears in two types. One is the level change, and the other is the pattern change. In this paper, we describe the monitoring of abnormal ST using PC based system. Hardware of this system consists of transmitter, receiver and PC. The function of transmitter is measuring ECG in three channels which are selected manually and transmitting the data to receiver by digital radio way. Connection with receiver and PC is by RS232C, and the data received on the PC is analyzed automatically by ECG analysis algorithm and saved to file. In the algorithm part for detecting abnormal ST, ST-segments are approximated by a polynomial. This method can detect all of the deviation and pattern change of ST-segment regardless the change in the heart rate or sampling rate. To gain algorithm reliability, the method rejects distorted polynomial approximation by calculation the difference between the approximated ST-segment and original ST-segment. In pre-signal processing, the wavelet transformation separates high frequency bands including QRS complex from the original ECG. Consequently, the process improves the performance of detecting each feature points.

  • PDF