• Title/Summary/Keyword: rebound test hammer

Search Result 55, Processing Time 0.022 seconds

Change in the Concrete Strength of Forest Road Drainage Systems Caused by Forest Fires (산불로 인한 임도 배수시설의 콘크리트 강도 변화)

  • Ye Jun Choe;Jin-Seong Hwang;Young-In Hwang;Hyeon-Jun Jeon;Hyeong-Keun Kweon;Joon-Woo Lee
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.4
    • /
    • pp.451-458
    • /
    • 2023
  • As forest fires continue to increase in scale worldwide, the importance of forest roads in relation to forest fire prevention and suppression has become increasingly evident. To ensure effective functioning during a forest fire disaster, it is crucial to apply appropriate road planning and ensure roads' structural integrity. However, previous studies have predominantly focused on the impact of forest fires on firebreak efficacy and road placement, meaning that insufficient attention has been paid to ensuring the safety of these facilities. Therefore, this study sought to compare the strength of concrete facilities within areas damaged by forest fires over the past three years by using the rebound hammer test to identify signs of thermal degradation. The results revealed that concrete facilities damaged by forest fires exhibited significantly lower strength (15.6 MPa) when compared with undamaged facilities (18.0 MPa) (p<0.001), and this trend was consistent across all the target facilities. Consequently, it is recommended that safety assessment criteria for concrete forest road facilities be established to prevent secondary disasters following forest fire damage. Moreover, continuous monitoring and research involving indoor experiments are imperative in terms of enhancing the stability of forest road structures. It is expected that such research will lead to the development of more effective strategies for forest fire prevention and suppression.

Condition assessment of fire affected reinforced concrete shear wall building - A case study

  • Mistri, Abhijit;Pa, Robin Davis;Sarkar, Pradip
    • Advances in concrete construction
    • /
    • v.4 no.2
    • /
    • pp.89-105
    • /
    • 2016
  • The post - fire investigation is conducted on a fire-affected reinforced concrete shear wall building to ascertain the level of its strength degradation due to the fire incident. Fire incident took place in a three-storey building made of reinforced concrete shear wall and roof with operating floors made of steel beams and chequered plates. The usage of the building is to handle explosives. Elevated temperature during the fire is estimated to be $350^{\circ}C$ based on visual inspection. Destructive (core extraction) and non-destructive (rebound hammer and ultrasonic pulse velocity) tests are conducted to evaluate the concrete strength. X-ray diffraction (XRD) and Field Emission Scanning Electron Microscopy (FESEM) are used for analyzing micro structural changes of the concrete due to fire. Tests are conducted for concrete walls and roof slab on both burnt and unburnt locations. The analysis of test results reveals no significant degradation of the building after the fire which signifies that the structure can be used with full expectancy of performance for the remaining service life. This document can be used as a reference for future forensic investigations of similar fire affected concrete structures.

The prediction of compressive strength and non-destructive tests of sustainable concrete by using artificial neural networks

  • Tahwia, Ahmed M.;Heniegal, Ashraf;Elgamal, Mohamed S.;Tayeh, Bassam A.
    • Computers and Concrete
    • /
    • v.27 no.1
    • /
    • pp.21-28
    • /
    • 2021
  • The Artificial Neural Network (ANN) is a system, which is utilized for solving complicated problems by using nonlinear equations. This study aims to investigate compressive strength, rebound hammer number (RN), and ultrasonic pulse velocity (UPV) of sustainable concrete containing various amounts of fly ash, silica fume, and blast furnace slag (BFS). In this study, the artificial neural network technique connects a nonlinear phenomenon and the intrinsic properties of sustainable concrete, which establishes relationships between them in a model. To this end, a total of 645 data sets were collected for the concrete mixtures from previously published papers at different curing times and test ages at 3, 7, 28, 90, 180 days to propose a model of nine inputs and three outputs. The ANN model's statistical parameter R2 is 0.99 of the training, validation, and test steps, which showed that the proposed model provided good prediction of compressive strength, RN, and UPV of sustainable concrete with the addition of cement.

Prediction of Hybrid fibre-added concrete strength using artificial neural networks

  • Demir, Ali
    • Computers and Concrete
    • /
    • v.15 no.4
    • /
    • pp.503-514
    • /
    • 2015
  • Fibre-added concretes are frequently used in large site applications such as slab and airports as well as in bearing system elements or prefabricated elements. It is very difficult to determine the mechanical properties of the fibre-added concretes by experimental methods in situ. The purpose of this study is to develop an artificial neural network (ANN) model in order to predict the compressive and bending strengths of hybrid fibre-added and non-added concretes. The strengths have been predicted by means of the data that has been obtained from destructive (DT) and non-destructive tests (NDT) on the samples. NDTs are ultrasonic pulse velocity (UPV) and Rebound Hammer Tests (RH). 105 pieces of cylinder samples with a dimension of $150{\times}300mm$, 105 pieces of bending samples with a dimension of $100{\times}100{\times}400mm$ have been manufactured. The first set has been manufactured without fibre addition, the second set with the addition of %0.5 polypropylene and %0.5 steel fibre in terms of volume, and the third set with the addition of %0.5 polypropylene, %1 steel fibre. The water/cement (w/c) ratio of samples parametrically varies between 0.3-0.9. The experimentally measured compressive and bending strengths have been compared with predicted results by use of ANN method.

A Study on the Compressive Strength Prediction of Crushed Sand Concrete by Non-Destructive Method (부순모래 콘크리트의 비파괴 시험에 의한 압축강도 추정에 관한 연구)

  • Kim, Myung-Sik;Baek, Dong-Il;Kim, Kang-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.75-81
    • /
    • 2007
  • Percentage that aggregate of materials that concrete composed about $70{\sim}80%$ of whole volume, therefore influence that quality of aggregate gets in concrete characteristics are very important. Schmidt hammer and ultra-sonic velocity method are commonly used for crushed sand concrete compressive strength test in a construction field. At present, various equations for prediction of strength are present, which have been used in a construction field. The purpose of this study is to evaluate the correlation between prediction strength by present equations and destructive strength to test specimen, and find out which is a suitable equation for the construction site, a strength test was carried out destructive test by means of core sampling and traditional test. The experimental parameters were concrete age, curing condition, and strength level. It is demonstrated that the correlation behavior of crushed sand concrete strength in this study good due to the perform analysis of correlation between core, destructive strength and non-destructive strength.

Calculation of Aging Effects of Ultrasonic Pulse Velocity in Concrete by Non-Destructive Test (비파괴시험에 의한 콘크리트 초음파속도의 재령계수 산정)

  • Cho, Chang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.173-179
    • /
    • 2008
  • This paper aims to calculate age coefficient of ultrasonic pulse velocity by non-destructive test. When concrete compressive strength is measured by non-destructive test, rebound test hammer method is applied to estimate age coefficient depending on the course of time after concrete casting, but ultrasonic pulse velocity method is not applied in the process. Although it is necessary to consider age coefficient with change of ultrasonic pulse velocity of concrete depending on aging, there have been little attempts to apply that method. The experiments were conducted to calculate aging effects which will be applied to establish the formula of measuring concrete strength. As a result of experiments, it was found that ultrasonic pulse velocity showed radical changes depending on concrete hardening in comparison with initial standard values. So, it was concluded that age coefficient must be applied to calculate strength. In conclusion, age coefficient of ultrasonic pulse velocity of concrete was suggested on the basis of experimental results.

Evaluation of Freeze-Thaw Damage on Concrete Using Nonlinear Ultrasound (초음파의 비선형 특성을 이용한 콘크리트 동결융해 손상 평가)

  • Choi, Ha-Jin;Kim, Ryul-Ri;Lee, Jong-Suk;Min, Ji-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.56-64
    • /
    • 2021
  • Leakage due to deterioration and damage is one of the major causes of volume change by freezing and thawing, and it leads micro-cracking and surface scaling in concrete structures. The deterioration of damaged concrete accelerates with the chloride attack. Thus, in the detailed guidelines for facility performance evaluation (2020), the quality of cover concrete and the freeze-thaw (FT) repetition cycle were newly suggested for concrete durability assessment. The quality of cover concrete should be evaluated by the rebound hammer test and the FT repetition cycle should be also considered in the deterioration environmental assessment. This study suggested the application of fast dynamic based nonlinear ultrasound method to monitor initial micro-scale damage under freezing and thawing environment. Concrete specimens were fabricated with different water-cement ratios (40%, 60%) and air contents (1.5% and 3.0%). The compressive strength, rebound number, relative dynamic modulus, and nonlinear ultrasound were measured with different FT cycles. The scanning electron microscopy was also performed to investigate the micro-scale FT damage. As a result, both the rebound number and the relative dynamic modulus had difficulty to detect early damage but the proposed method showed a potential to detect initial micro-scale damage and predict the FT resistance performance of concrete.

Estimation of R-value and Uniaxial Compressive Strength of Rocks around the King Sejong Station, Barton Peninsula, Antarctica from SilverSchmidt Q-value (실버슈미트 Q값으로부터 남극 바톤반도 세종과학기지 주변 암석의 R값 및 일축압축강도 추정)

  • Lim, Hyoun-Soo;Jang, Bo-An;Kim, Jung-Han;Kang, Seong-Seung
    • Tunnel and Underground Space
    • /
    • v.25 no.2
    • /
    • pp.199-209
    • /
    • 2015
  • The rebound hardness test using the SilverSchmidt hammer was performed for diorite, granodiorite, and andesite exposed around the King Sejong Station, Barton peninsula. Then, the R-value and uniaxial compressive strength (UCS) of these rocks were estimated from the Q-values which were obtained from the SilverSchmidt hammer. The Q-value of diorite was distributed in the range from 67.0 to 89.5, granodiorite of the range from 57.5 to 89.0, and andesite of the range from 58.0 to 76.5. The average Q-values of diorite, granodiorite, and andesite were 76.0, 72.0, and 67.0, respectively. The converted UCS of diorite was distributed in the range from 118 to 195 MPa, granodiorite of the range from 91 to 193 MPa, and andesite of the range from 92 to 148 MPa. The average UCS of diorite, granodiorite, and andesite were 147, 136, and 117 MPa, respectively. The converted R-value of diorite was distributed in the range from 53.0 to 72.2, granodiorite of the range from 45.4 to 71.8, and andesite of the range from 45.8 to 60.9. The average Q-values of diorite, granodiorite, and andesite were 60.0, 58.0, and 53.0, respectively. The R-value was represented approximately 20% lower than the Q-value. In conclusion, it will be possibile that the R-value and UCS of rocks under the extreme area from the SilverSchmidt Q-value are evaluated.

Characteristics of Excess Water Dewatered Concrete Using Permeable Liner (투수시트를 적용하여 잉여수를 탈수한 콘크리트의 강도 특성)

  • Jeon, Kyu-Nam;An, Gi-Hong;Lee, Jong-Suk
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.6
    • /
    • pp.675-682
    • /
    • 2013
  • In this study, to enhance the quality of concrete surface by removing the surplus water, permeable liner attached the euroform was applied for manufacturing concrete specimens. Various kinds of concrete mixtures with different water to binder ratios were applied and the strength properties of the hardened concrete surfaces were evaluated at different heights. Experimental results showed that the rebound values by schmidt hammer test and the compressive strengths on the surfaces of concrete specimens were increased as proportion to the amount of mixture water which is dependent on the water to binder ratio of each concrete mixture, and more enhancements were observed on the middle and lower specimen surfaces than the upper region. SEM analysis also showed that much denser hydrate structures were observed on the specimen surfaces by the application of the permeable liner while similar hydrate formations were occurred regardless of surface treatment conditions. From the MIP test results of the concrete surfaces, it was observed that, by the application of permeable liner, the pore volume below $0.01{\mu}m$ was decreased with a maximum of 50% resulting in the densification of pore structures.

Study on the Physical Properties according to the Anisotropy of Granite (화강암의 이방성에 따른 물리적 특성 연구)

  • 박윤석;강추원
    • Explosives and Blasting
    • /
    • v.21 no.4
    • /
    • pp.23-35
    • /
    • 2003
  • This study is to clarify the comparative relationship and a mechanical anisotropy of rock on the subject of granite distributed in the Namwon area Uniaxial compressive and Brazilian strengths with respect to the horizontal and vertical axes of granite are shown the linear relation. In the case of the result of the p-wave velocity measurement. it is represented that the velocity of vortical direction is faster about 10 to 15% than other two horizontal directions. The difference between velocities is caused by a developmental pattern of microcracks distributed in rock. Moreover, this result is very consistent with the result investigated through thin sections. The proportion of uniaxial compression strength to Index of point load strength ($Is_{(50)}$) is 18~20 times in case of granite. Uniaxial compressive strength is relatively good relationship with point load strength, Schmidt hammer rebound value, and tensile strength point load strength of them is the best comparative relationship. It is indicated that point load test is the most useful tool to estimate uniaxial compressive strength, comparing with other experimental methods.