DOI QR코드

DOI QR Code

Characteristics of Excess Water Dewatered Concrete Using Permeable Liner

투수시트를 적용하여 잉여수를 탈수한 콘크리트의 강도 특성

  • Jeon, Kyu-Nam (Structural Engineering Research Division, Korea Institute of Construction Technology) ;
  • An, Gi-Hong (Structural Engineering Research Division, Korea Institute of Construction Technology) ;
  • Lee, Jong-Suk (Structural Engineering Research Division, Korea Institute of Construction Technology)
  • 전규남 (한국건설기술연구원 인프라구조연구실) ;
  • 안기홍 (한국건설기술연구원 인프라구조연구실) ;
  • 이종석 (한국건설기술연구원 인프라구조연구실)
  • Received : 2013.09.12
  • Accepted : 2013.10.16
  • Published : 2013.12.31

Abstract

In this study, to enhance the quality of concrete surface by removing the surplus water, permeable liner attached the euroform was applied for manufacturing concrete specimens. Various kinds of concrete mixtures with different water to binder ratios were applied and the strength properties of the hardened concrete surfaces were evaluated at different heights. Experimental results showed that the rebound values by schmidt hammer test and the compressive strengths on the surfaces of concrete specimens were increased as proportion to the amount of mixture water which is dependent on the water to binder ratio of each concrete mixture, and more enhancements were observed on the middle and lower specimen surfaces than the upper region. SEM analysis also showed that much denser hydrate structures were observed on the specimen surfaces by the application of the permeable liner while similar hydrate formations were occurred regardless of surface treatment conditions. From the MIP test results of the concrete surfaces, it was observed that, by the application of permeable liner, the pore volume below $0.01{\mu}m$ was decreased with a maximum of 50% resulting in the densification of pore structures.

이 연구에서는 콘크리트 타설 시 발생하는 잉여수를 제거하여 피복 콘크리트의 성능을 향상 시키고자 거푸집에 구멍을 뚫지 않은 일반 유로폼에 투수시트를 부착하여 타설한 콘크리트의 물-결합재비 종류 및 시험체 높이에 따른 강도 특성을 분석하였다. 슈미트해머 반발경도 및 압축강도의 경우 투수시트면이 물-결합재비가 높은 배합일수록 크게 나타났으며, 시험체의 높이에 따라서는 상부보다는 중부 및 하부에서 크게 나타남을 알 수 있었다. SEM 분석 결과의 경우 수화물의 생성형태는 유사하였으나 투수시트면이 일반면에 비해 공극이 확연히 감소되고 밀실해 지는 것으로 나타났으며, MIP 분석 결과 투수시트를 사용하였을 경우 $0.01{\mu}m$ 이하 공극량이 최대 50%까지 감소되어 공극이 치밀해지는 것으로 나타났다.

Keywords

References

  1. JSCE, Recommendation for Concrete Repair and Surface Protection of Concrete Structures, 2005.
  2. Han, C. G., Kim, S. W., Koh, K. T., and Han, M. C., "Property of Low Shrinkage High Performance Concrete depending on Mixture Proportions and Material Characteristics," Journal of the Korea Concrete Institute, Vol. 116, No. 6, 2004, pp. 805-811.
  3. Jaung, J. D., "An Experimental Study on the Strength Increase of Concrete Surface by the Holed Molds (2)," Journal of the Architectural Institute of Korea, Vol. 19, No. 7, 2003, pp. 71-78.
  4. Jaung, J. D., An Experimental Study on the Effect of Carbonation to the Concrete Properties, Tohoku University, 1989.
  5. Fukuchi, T. and Tateyama, S., "A Study on Prediction of Concrete Quality from Earlier Strengths," Architectural Institute of Japan, Vol. 57, 1982, pp. 175-176.
  6. Mamoru, K., "A Measuring Method for Water Cement Ratio in Fresh Concrete," Japan Society of Civil Engineers, No. 193, 1971, pp. 115-123.
  7. Architectural Institute of Japan, Guides on Plan and Quality Control of Concrete, 1979.
  8. Schubel, P. J., Warrior, N. A., Elliott, K. S., and Jones, M., "An Investigation into the Critical Factors Affecting the Performance of Composite Controlled Permeable Formwork Liners: Part I-Drainage medium Original Research Article," Construction and Building Materials, Vol. 22, Issue 7, 2008, pp. 1551-1559. (doi: http://dx.doi.org/10.1016/j.conbuildmat.2007.03.030)
  9. Lee, J. S., "Properties of Permeable Formwork Using Permeable Liner," Journal of the Korea Society of Civil Engineers, Vol. 32, No. 6A, 2012, pp. 419-426. https://doi.org/10.12652/Ksce.2012.32.6A.419
  10. Basheer, L., Nanukuttan, S. V., and Basheer, P. A. M., "The Influence of Reusing 'Formtex' Controlled Permeability Formwork on Strength and Durability of Concrete," Materials and Structures, Vol. 41, 2008, pp. 1363-1375. https://doi.org/10.1617/s11527-007-9335-9
  11. Mehta, P. K., Concrete, Structure Properties and Materials, Prentice Hall, 1973.
  12. Tatematsu, K. and Ishihara, S., "Changes in Pore Structure and Enhanced Durability of Concrete by the Use of Permeable Forms," Japan Concrete Institute, Vol. 8, No. 1, 1997, pp. 171-178.
  13. Matsuda, T., Maeda, T., Mishima, N., and Hatanaka S., "Effect of Revibration on Strength Properties of Concrete Cast into Water Permeability Form," Japan Concrete Institute, Vol. 24, No. 1, 2002, pp. 345-350.
  14. Architectural Institute of Korea, Architectural Standard Specification, 2013.
  15. Arslan, M., "Effects of Drainer Formworks on Concrete Lateral Pressure," Construction and Building Materials, Vol. 16, Issue 5, 2002, pp. 253-259. (doi: http://dx.doi.org/ 10.1016/S0950-0618(02)00025-9)