• 제목/요약/키워드: real power control

검색결과 1,429건 처리시간 0.03초

실시간 계통제어를 위한 동기위상측정장치 개발 (The development of synchronized phasor measurement device for real time power system control)

  • 전진홍;김학만;전영환;국경수;김지원;오태규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.85-87
    • /
    • 2000
  • In real-time power system control, it is essential to measure the power system variables which are voltage. current, real and reactive power, power factor, system frequency and etc. this variables can be estimated or calculated by the synchronized phasor informations of voltage and current. Therefore, the synchronized phasor measurement of voltage and current is very important to real-time power system control. So, we develop SPMD(Synchronized Phasor Measurement Device) for synchronized phasor measurement of voltage and current. In this paper, we present the design and implementation of SPMD for real-time phasor measurement and prove its performance by the test results.

  • PDF

계통전압.무효전력 제어에 관한 연구 (A study for the system voltage and reactive power control)

  • 송길영
    • 전기의세계
    • /
    • 제14권3호
    • /
    • pp.10-17
    • /
    • 1965
  • This paper presents a method of the voltage-reactive power control in the long and short range operations and introduces a conception, "optimum control pattern." The optimum control pattern, aiming at the over-all system control, is defined as the optimum voltage distribution which minimizes the system operating cost under the conditions that the specified power be supplied and the system voltage be kept within the specified bounds. The following procedure was adopted to obtain this optimum pattern. In the first place, a power system was divided into three blocks, namely, load, substation and generator. Lagrange's, multiplier method is applied to each block in turn, paying attention only at the operating voltage distribution. Phase angles at each bus are then modified so that the continuity of active power is maintained. This procedure may be called "block relaxation method with Lagrange's multipliers." In a long range operation, this control pattern determines the optimum installation capacity of reactive power sources. In a short range operation, it also gives the reference state of real time control and the optimum switching capacity of reactive power souces. The real time control problem is also studied from the standpoint of cooperation of control devices such as generators, shunt capacitors, shunt reactors and ratio load controllers. A proposal for the real time control will contribute to the automation of power system operation in the near future. in the near future.

  • PDF

Comparison of Capacitor Voltage Balancing Methods for 1GW MMC-HVDC Based on Real-Time Digital Simulator and Physical Control Systems

  • Lee, Jun-Min;Park, Jung-Woo;Kang, Dae-Wook;Lee, Jong-Pil;Yoo, Dong-Wook;Lee, Jang-Myung
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1171-1181
    • /
    • 2019
  • Modular Multilevel Converter (MMC)-based HVDC power transmission using a real-time simulator is one of the key technologies in power electronics research. This paper introduces the design methodology of a physical MMC-HVDC control system based on a Field-Programmable Gate Array (FPGA), which has the advantage of high-speed parallel operation, and validates the accuracy of MMC-HVDC control when operated with a Real-Time Digital Simulator (RTDS). Finally, this paper compares and analyzes the characteristics of capacitor voltage balancing methods such as Nearest Level Control (NLC), NLC with a reduced switching frequency, and tolerance band modulation implemented on physical control system.

Transient stability improvement using quasi-multi pulse BTB-STATCOM

  • Vural, Ahmel M.;Bayindi, Kamil C.
    • Advances in Energy Research
    • /
    • 제2권1호
    • /
    • pp.47-59
    • /
    • 2014
  • Back-to-back STATCOM configuration is an extension of STATCOM in which the reactive power at two-sides and the real power flow through the DC link can be controlled concurrently and independently. This flexible operation brings many advantages to the micro-grids, distributed generation based systems, and deregulated power systems. In this paper, the dynamic control characteristics of the back-to-back STATCOM is investigated by simulating the detailed converter-level model of the converters in PSCAD. Various case studies in a single-machine test system are studied to present that the real power control feature of the BtB-STATCOM, even with a simple controller design, can enhance the transient stability of the machine under different fault scenarios.

실제 풍속을 이용한 DFIG 풍력발전시스템 구현에 관한 연구 (A Study on DFIG Wind Power Generation System Modelling using Real-Wind Speed)

  • 변길성;박인권;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.494_495
    • /
    • 2009
  • This paper presents a study of DFIG wind power generation system for real-time simulation. For real-time simulation, the real-time digital simulator (RTDS) and its user friendly interface simulation software (RSCAD) are used. 2.2MW grid-connected variable speed DFIG wind power generation system is modeled and analyzed in this study. Stator-flux oriented vector control scheme is applied to stator, rotor side converter control, and back-to-back PWM converters are implemented for the decoupled control. The real-wind speed signal extracted by an anemometer is used for realistic and accurate simulation analysis. Block diagrams for DFIG and control scheme of stator, rotor-side are introduced. Real-time simulation cases are carried out and analyzed for the validity of this work.

  • PDF

EMS data 분석 및 최적화 기법을 적용한 제어지역별 목표운전전압 제안 (Target Operation Voltage Guidelines Considering Voltage Level in Each Voltage Control area by Applying Optimization Technique Through EMS Data Observation)

  • 성웅;김재원;김태균;이병준;정응수;조종만
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.671-678
    • /
    • 2009
  • This paper presents target operation voltage guidelines of each voltage control area considering both voltage stability and economical efficiency in real power system. EMS(Energy Management System) data, Real-time simulator, shows not only voltage level but lots of information about real power system. Also this paper performs optimal power flow calculation of three objective functions to propose the best target operation voltage. objective function of interchange power flow maximum and active power loss minimization stand for economical efficiency index and reactive power reserve maximum objective unction represents stability index. Then through simulation result using optimazation technique, the most effective objective function is chosen. To sum up, this paper divides voltage control area into twelve considering electric distance characteristics and estimate or voltage level by the passage of time of EMS peak data. And through optimization technique target operation voltage of each voltage control area is estimated and compare heir result. Then it is proposed that the best scenario to keep up voltage stability and maximize economical efficiency in real power system.

Hybrid Fuzzy PI-Control Scheme for Quasi Multi-Pulse Interline Power Flow Controllers Including the P-Q Decoupling Feature

  • Vural, Ahmet Mete;Bayindir, Kamil Cagatay
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.787-799
    • /
    • 2012
  • Real and reactive power flows on a transmission line interact inherently. This situation degrades power flow controller performance when independent real and reactive power flow regulation is required. In this study, a quasi multi-pulse interline power flow controller (IPFC), consisting of eight six-pulse voltage source converters (VSC) switched at the fundamental frequency is proposed to control real and reactive power flows dynamically on a transmission line in response to a sequence of set-point changes formed by unit-step reference values. It is shown that the proposed hybrid fuzzy-PI commanded IPFC shows better decoupling performance than the parameter optimized PI controllers with analytically calculated feed-forward gains for decoupling. Comparative simulation studies are carried out on a 4-machine 4-bus test power system through a number of case studies. While only the fuzzy inference of the proposed control scheme has been modeled in MATLAB, the power system, converter power circuit, control and calculation blocks have been simulated in PSCAD/EMTDC by interfacing these two packages on-line.

분산제어를 위한 필드제어시스템의 실시간 데이터 연계 (a Study on the Real-time Data Linkage of Field Control System for Distributed Control)

  • 김석곤;송성일;오응세;이성우;곽귀일;이은웅;박태림
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.777-779
    • /
    • 2003
  • This paper describes the real-time data linkage of the field control system for distributed control in nuclear power plant environment. The most important keys of digital control system in nuclear power plant are the reliability and stability of system, and real-time control ability. This Paper brought up the hardware construction using a new method about the design of each station located upon control transmission network to improve real-time ability of field control system, and measured the station binding time between devices connected to field control module. And it was confirmed performance improvement of overall system for real-time data linkage between control devices.

  • PDF

FUZZY 이론을 이용한 전압.무효전력의 순서제어에 관한 연구 (STUDY ON THE REAL TIME VOLTAGE-REACTIVE POWER CONTROL USING THE FUZZY THEORY)

  • 송길영;김세영;조준우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.231-234
    • /
    • 1990
  • This paper shows real-time control technique of voltage-reactive power using the fuzzy theory. Here, major benefits of applying the fuzzy set theory as follow. First, heuristic knowledge of operator has been used in the operation and control of power system. Second, difficulties in traditional multi-objective numerical solution methods have been solved. Also, to achieve optimizing process on the voltage-reactive power control conventional search method have been used.

  • PDF

FACTS기기의 유효전력 제어특성을 고려한 모선간 송전용량 평가 알고리즘 (An Algorithm for BITC Evaluation considering the Power Control Characteristics of FACTS Devices)

  • 윤용범;추진부
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권2호
    • /
    • pp.113-118
    • /
    • 1999
  • In this, sensitivity based approach to estimate BITC(bilateral interchange transfer capacity) considering the real power flow control function of FACTS devices is presented. The real power flow setting of the FACTS devices is adjusted so that it transfers the power flow from the first violation point of transmission capacity to other transmission lines in the power system, thus allowing more power to be transferred from the specified generator bus to the specified load bus. The transfer between the two bus locations is increased from this new operating condition until a violation of transmission capacity limits occurs or until the setting of the FACTS devices can no longer be adjusted. The proposed algorithm is illustrated using examples of small and real life power system.

  • PDF