The quality condition of concrete in the hydraulic structures and a plan improving Quality (콘크리트 수리구조물의 품질상태와 개선방향)

  • Park, Kwang-Su;Shin, Su-Kyun;Kim, Kwan-Ho;Lee, Joon-Gu;Kim, Meyong-Won;Jang, Dan-Gum
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.407-410
    • /
    • 2003
  • The actual quality of the concrete in the structure for Irrigation may differ from that represented by the cylinders because the age, consolidation, or curing of the in-place material may not be well represented by the standard test specimens. The objective of this paper is to offer a base data of specification is the best fit the ready-mixed concrete strength to the specified, and to address this deficiency, so that the strength information of the concrete in the structure for Irrigation can be rationally accounted for in the assessment of the quality condition of this. The strength of concrete in the hydraulic structures is checked using strength of core obtained from that, and 28-day-old cylinder strength is analyzed using cylinder data of the ready-mixed concrete.

  • PDF

The Chloride Ion Diffusivity of Ready-Mixed Concrete Depending on Specified Compressive Strength (레디믹스트 콘크리트의 설계기준 압축강도별 염소이온 확산특성)

  • Park, Dong-Cheon;Kim, Yong-Ro
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.6
    • /
    • pp.543-550
    • /
    • 2018
  • The RC buildings which are constructed on the seaside are followed by KBC(2016) to achieve the minimization of durability damage. To control the corrosion of the reinforcing steel bar by salt attack, W/C should be under 0.4 and specified concrete strength is higher than 35MPa in the concrete/building construction standard specification. Even though it has been proved that the concrete mixed with mineral admixture such as blast furnace slag and fly ash etc. have high strength and durability in previous researches, the beneficial informations are not applied to the codes. Ready-mixed concretes which usually include the admixtures in Busan were tested to certify the salt attack durability. In the same specified concrete strength, remarkable salt attack durability was evaluated in comparison to OPC. For economical and reliable durability design, chloride ion diffusivity should be measured before applying to new building construction.

Development of the Proportion Design Program for 40$\sim$60MPa High Strength Concrete (40$\sim$60MPa급 고강도 콘크리트 배합설계 프로그램 개발)

  • Yoo, Seung-Yeup;Choi, Dong-Ho;Lee, Sang-Rae;Koo, Ja-Sul;Kang, Suck-Hwa
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.401-404
    • /
    • 2008
  • This study exploited the design of mixture proportion for the high strength concrete to establish the method of the quality control and high strength ready-mixed concrete for the application to the construction filed systematically how to output the estimated formula which could forecast mixture proportion for the high strength concrete classed 40${\sim}$60MPa through a experiment. It might contribute for systematic establishment of the method of the quality control and high strength ready-mixed concrete because it was possessed of the function of common data though a server, preservation and output of data, and estimation for the design of mixture proportion for the high strength concrete due to the experimental result, and Visual Basic, MS-SQL were used. Simply, it was produced corresponding to the condition of a laboratory, so it could be fundamental data for the design of mixture proportion for the high strength concrete. If upgrade is enforced with mixture proportion data of the each factory after then, it may contribute to the stability on quality and manufacture of high strength ready-mixed concrete to agree with the properties of each factory.

  • PDF

TECHNICAL APPLICATION OF READY MIXED CONCRETE SLUDGE WATER TO CEMENT MATRIX

  • Moon, Han-Young;Shin, Hwa-Cheol
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.555-559
    • /
    • 2001
  • A by-product, waste sludge water produced from ready mixed concrete(remicon) factories may affect our environmental contamination if it is discharged without proper waste disposal. In Korea, all waste sludge water has been recycled in the way of mixing water of remicon, but the quality of the concrete then produced can be deteriorated, so it might cause slump loss or irregular compressive strength. In this study, waste sludge water is divided into two parts, remicon sludge and residual water in order to make it's property more stable. Then, the remicon sludge and high-alkaline residual water were used as admixture and alkali activator respectively. In this paper we research about quality of with remicon sludge and residual water and performed the fundamental properties of cement matrix mixed with remicon sludge and residual water.

  • PDF

A Study on the Investigation of Performance for Evaluation Method of Unit Water Content of Fresh Concrete (굳지 않은 콘크리트 단위수량 추정기법의 성능 검토에 관한 연구)

  • Kim, Yong-Ro;Choi, Il-Ho;Jung, Yang-Hee;Kim, Hyo-Rak;Lee, Do-Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.367-370
    • /
    • 2005
  • In this study, air meter method and capacitance measurement method to apply economically at quality control of ready-mixed concrete among various unit water content measurement technique was selected. Then, it was evaluated estimating performance of unit water content according to the change of water-binder ratio and unit water content. Also, it was examined influence about error occurrence of unit water content by change of properties of used materials. Finally, based on this study, it was proposed fundamental data to utilize measurement technique of unit water content to quality control. of ready-mixed concrete in construction field.

  • PDF

A Fundamental Study on Supply Status and Use Plan of Fine Aggregates (잔골재의 수급현황 및 활용방안에 관한 기초적 연구)

  • Yu Myoung Youl;Lee Sea-Hyun;Lee Hyun-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.101-104
    • /
    • 2005
  • It analyzed the supply status of fine aggregate and find the point of issue related alternative fine aggregate through researches and interviews. The conclusions of the study are as follows. 1. Ready mixed concrete manufacture used crushed fine aggregate (15.5$\%$) and recycled fine aggregate (1.5$\%$) for alternatives aggregate than 1.3$\%$ in 1991. It is not allowed to use a recycled fine aggregate in ready mixed concrete, but they used it. 2. All alternative aggregate are satisfied the Korean Standard, But they showed low properties of mortar compared to when it replaced with natural fine aggregate. So, it is needed to make another special Korean Standard to use alternative aggregate in normal concrete by mixing method to recover the workability and compressive strength.

  • PDF

A Study on the Quality Deviation of High-Strength Concrete from Multiple Ready Mixed Concrete Companies (다수 레미콘사에서 납품된 콘크리트 품질 편차에 관한 연구)

  • Park, Dong-Cheon;Seok, Won-Kyun;Jeon, Hyun-Soo;Kim, Young-Sun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.577-583
    • /
    • 2022
  • On large-scale sites, concrete is often delivered from a number of ready-mixed concrete companies, but even if the same concrete mixture table is used, it is thought that there will be a difference in quality due to differences in materials and manufacturing equipment. Due to a lack of previous research in this area, this study measured the properties of fresh concrete, compressive strength, and chlorine ion diffusion coefficient using the concrete supplied by 12 ready-mixed companies in Busan. The fresh concrete properties met the criteria. The compressive strength increased by 137% for 30MPa, 131% for 45MPa, and 117% for 80MPa by specified compressive strength. For the chlorine ion diffusion coefficient, the average value for each specified compressive strength could be derived without significant variation. The higher the compressive strength, the greater the deviation , and the lower the compressive strength, the greater the deviation in the chlorine ion diffusion coefficient.

A study on ready-mixed-mortar for prestressed concrete grouting material (PC(Prestressed Concrete)그라우트용 레미탈에 관한 연구)

  • 박길수;전진호;김경덕;이학봉;노현승;이완경
    • Cement Symposium
    • /
    • no.27
    • /
    • pp.54-60
    • /
    • 2000
  • As conventional grouting materials for the sheath such as cement slurry or cement-mortar are mixed and pumped in site, those harden with bleeding or shrinkage and meets low compressive strength. Also the materials haven''t always same cements, sand size d

  • PDF