• Title/Summary/Keyword: readout

Search Result 269, Processing Time 0.027 seconds

Polarization multiplexing of holography memory in photopolymer (포토폴리머에서 편광방식을 이용한 홀로그래픽 메모리의 다중화)

  • Jeong, Hyeon-Seop;Kim, Nam;Sin, Chang-Won;Kim, Eun-Gyeong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.275-276
    • /
    • 2007
  • A multiplex recording and reading technique in photopolymer are presented In order to record the polarization gratings, polarization-sensitive materials, in which linear birefringence is induced by irradiating the polarized light, are necessary. We checked orthogonal and independence of laser. The value of the photoinduced linear polarization had effect on diffraction properties in the holographic gratings. The grating strengths of two polarization are investigated and the relevant parameters for equal diffraction intensity readout are optimized.

  • PDF

Construction of a 40-channel SQUID System and Its Application to Neuromagnetic Measurements

  • Lee, Y.H.;Kim, J.M.;Kwon, H.C.;Park, Y.K.;Park, J.C.;Lee, D.H.;Ahn, C.B.
    • Progress in Superconductivity
    • /
    • v.2 no.1
    • /
    • pp.20-26
    • /
    • 2000
  • A 40-channel superconducting quantum interference device (SQUID) system was constructed for measuring neuromagnetic fields. Main features of the system are the use of double relaxation oscillation SQUIDs (DROSs), and planar gradiometers measuring magnetic field components tangential to the head surface. The DROSs with high flux-to-voltage transfers enabled direct readout of the SQUID output by room-temperature dc preamplifiers and simple flux-locked loop circuits could be used for SQUID operation. The pickup coil is an integrated first-order planar gradiometer with a baseline of 40 mm. Average noise level of the 40 channels is around 1.2 $fT/cm/{\surd}Hz$ at 100 Hz, corresponding to a field noise of 5 $fT/{\surd}Hz$, operated inside a magnetically shielded room. The SQUID insert was designed to have low thermal load, minimizing the loss of liquid helium. The constructed system was applied to measure auditory-evoked neuromagnetic fields.

  • PDF

Real-time Blood Pressure Monitoring in Porcine Tibial Artery Using LC Resonant Pressure Sensor (LC 공진형 압력 센서를 이용한 돼지 경골 동맥의 실시간 혈압 측정)

  • Choi, Won-Seok;Kim, Jin-Tae;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.445-450
    • /
    • 2012
  • We have developed an implantable wireless sensor for real time pressure monitoring of blood circulation system. MEMS (micro-electro-mechanical system) technology was adopted as a sensor development method. The sensor is composed of photolithographically patterned inductors and a distributed capacitor in gap between the inductors. A resulting LC resonant system produces its resonant frequency in range of 269 to 284 MHz at 740 mmHg. To read the resonant frequency changed by blood pressure variation, we developed a custom readout system based on a network analyzer functionality. The bench-top testing of the pressure sensors showed good mechanical and electrical functionality. A sensor was implanted into tibial artery of farm pig, and interrogated wirelessly with accurate readings of blood pressure. After 45 days, the sensor's electrical response and histopathology were studied with good frequency reading and biocompatibility.

A Neutravidin-based Assay for Reverse Transcriptase Suitable for High Throughput Screening of Retroviral Activity

  • Brennan, Lyndall E.;Sune, Carlos;Klimkait, Thomas
    • BMB Reports
    • /
    • v.35 no.3
    • /
    • pp.262-266
    • /
    • 2002
  • A non-isotopic neutravidin-based reverse transcriptase (RT) assay adapted for high throughput screening of HIV activity is described. Using a 96-well microtitre plate, HIV particles are lysed and the RT enzyme released into a reaction mixture containing poly(A) RNA, biotinylated oligo d(T) and fluorescein-labelled dUTP (FI-dUTP). With poly(A) as a template and oligo d(T) as primer, the viron RT incorporates FI-dUTP into an elongating DNA strand. The resulting product is captured on a neutravidin-coated 96-well plate and the unincorporated nucleotides removed by a series of washing steps. A simple ELISA is subsequently performed using a monoclonal antifluorescein antibody conjugated to alkaline phosphatase. Quantification of RT activity is facilitated by a colorimetric readout. The assay was validated in the context of a diagnostic HIV-1 phenotyping assay. Using supernatants from HIV-1 infected lymphocyte cultures the assay was shown to be as sensitive as a radioactive assay and the RT activity correlated well with levels of cell-asociated HIV-p24. Importantly, even minor reductions of RT activity by virus variants with reduced fitness could be distinguished.

Clinical Usefulness of MR FLAIR Image in Mild Head Injuries (경증 두부외상 환자에서 MR FLAIR 영상의 임상적 유용성)

  • Kim, Sei-Yoon;Whang, Kum;Kim, Hun-Joo;Lee, Myoung-Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1182-1186
    • /
    • 2001
  • Objectives : MR fluid-attenuated inversion recovery(FLAIR) image uses paired long inversion time and relaxation time that nulls the signal from CSF. With nulling of the CSF long echo time readout could be used to increase T2-weighting, hence improving the conspicuousness of most tissue lesions without the deleterious effects of CSF artifact seen on T2 weighted sequence. We examed the usefulness of FALIR image in the diagnosis of mild head injury. Methods : A total of 38 patients with mild head injury were examined by FLAIR image. We compared those images with CT scan and T1, T2-weighted images. Careful observation of MR images were done by two well-trained neuroradiologists. Each image was compared for conspicuousness and detectability of traumatic lesions might have shown abnormal signal intensities. The Wilcoxon signed ranks test was used for statistical evaluation. Results : The FLAIR image was significantly more sensitive than those of other images(p<0.001). T2 FFE(Fast Field Echo) image was more useful for detection of small petechial hemorrhages. Conclusion : FLAIR image is considered to be more sensitive than those of conventional MR images in the evaluation of mild head injuries.

  • PDF

Silent Magnetic Resonance Imaging Using Rotating and Projection Reconstruction (회전 경사자계와 사상 재구성을 이용한 무소음 자기 공명 영상법)

  • Chung, S.T.;Park, S.H.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.555-558
    • /
    • 1997
  • A new approach to silent MR imaging using a rotating DC gradient has been explored and experimentally studied. As is known, acoustic or sound noise has been one of the major problems in handling patients, mainly due to the fast gradient pulsings in interaction with the main magnetic field. The sound noise is also proportionally louder as the magnetic field strength becomes larger. In this article, we have described a new imaging technique using a mechanically rotating DC gradient coil as an approach toward silent MR imaging, i.e., a mechanically rotated DC gradient effectively replaces both the phase encoding as well as the readout gradient pulsings and data obtained in this manner provides a set of project ion data which later can be used or the projection reconstructionorwithsomeinterpolation techniques one can also perform conventional 2-D FFT (Fast Fourier Transform) image reconstruction. We found, with this new technique, that the sound noise intensity compared with the conventional imaging technique, such as spin echo sequence, is reduced down to -20.7 dB or about 117.5 times. The experimental pulse sequence and its principle are described and images obtained by the new silent MR imaging technique are reported.

  • PDF

Bolometer-Type Uncooled Infrared Image Sensor Using Pixel Current Calibration Technique (화소 전류 보상 기법을 이용한 볼로미터 형의 비냉각형 적외선 이미지 센서)

  • Kim, Sang-Hwan;Choi, Byoung-Soo;Lee, Jimin;Oh, Chang-woo;Shin, Jang-Kyoo;Park, Jae-Hyoun;Lee, Kyoung-Il
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.349-353
    • /
    • 2016
  • Recently, research on bolometer-type uncooled infrared image sensor which is made for industrial applications has been increasing. In general, it is difficult to calibrate fixed pattern noise (FPN) of bolometer array. In this paper, average-current calibration algorithm is presented for reducing bolometer resistance offset. A resistor which is produced by standard CMOS process, on the average, has a deviation. We compensate for deviation of each resistor using average-current calibration algorithm. The proposed algorithm has been implemented by a chip which is consisted of a bolometer pixel array, average current generators, current-to-voltage converters (IVCs), a digital-to-analog converter (DAC), and analog-to-digital converters (ADCs). These bolometer-resistor array and readout circuit were designed and manufactured by $0.35{\mu}m$ standard CMOS process.

Construction and Operation of High-$T_c$ Scanning SQUID Microscope

  • Baeka, B.;Kim, Ho-chul;Khim, Z.G.;Lee, S.M.;Moon, S.H.;Oh, B.
    • Progress in Superconductivity
    • /
    • v.1 no.1
    • /
    • pp.20-25
    • /
    • 1999
  • We constructed a high-$T_c$ scanning SQUID microscope (SSM) operating in the liquid nitrogen. We used a washer-type YBCO SQUID with inner and outer dimensions of $12{\mu}m$ and $36{\mu}m$, respectively, which was grown on the $SrTiO^3$ bicrystal substrate. The sample, rather than SQUID, was scanned using two stepping motors. We also developed readout electronics, stepping motor controller, and the software for system control and data display. We took images of various samples using our SSM and found that the spatial resolution is about $40{\mu}m$ and noise level is lower than $10^{-7}T/{\surd}Hz$ at 100 Hz and higher at lower frequencies. The noise level was much higher than that of a typical SQUID due to the other coupling from the electric parts. We present a simple argument on the inductive coupling between the sample and the SQUID which should be under-stood for the proper interpretation of the obtained images. By comparing the measured data with the simulation results the gap between the SQUID and the sample is estimated to be $40{\mu}m$.

  • PDF

Annealing Effects on VOx Thin Film Deposited by DC Magnetron Sputtering Method

  • Park, Il-Mong;Han, Myeong-Su;Han, Seok-Man;Go, Hang-Ju;Kim, Hyo-Jin;Sin, Jae-Cheol;O, Tae-Seung;Kim, Dong-Il
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.223-223
    • /
    • 2011
  • 적외선 감지기로 사용되는 microbolometer 소자재료로 VOx 또는 비정질 Si이 가장 많이 사용된다. 그 중에서 VOx 물질은 온도저항계수 즉, TCR이 높고 감지도가 우수하기 때문에 비냉각 적외선 검출기에 많이 응용된다. Microbolometer 검출기는 그 응답도는 micromachining 공정에 의해 좌우되는 열 고립구조에 의해 좌우된다. 특히 TCR 값이 크고, 열시상수 값이 작을수록 양질의 감지도를 얻을 수 있으므로 재료의 선택 및 공정이 매우 중요하다. 따라서 본 연구에서는 비냉각 적외선 감지소자로 사용되는 VOx 박막을 DC Sputtering을 사용하여 증착하였으며, 그 특성을 조사하였다. MEMS 공정에 의한 센서의 제작은 적외선을 흡수하여 저항변화를 읽어내어 판독하는 Readout IC(ROIC) 위에 행해진다. Monolithic 공정에 의해 이러한 ROIC 위에서 공정이 동시에 행해지므로 공정온도는 매우 중요한 요소로 작용한다. 따라서 증착된 VOx 박막의 열처리 효과를 연구하였다. 열처리 온도는 $250^{\circ}{\sim}420^{\circ}C$, 열처리 시간은 20~80 min 까지 변화시켰다. 갓 증착된 VOx 박막의 저항은 약 200 $k{\Omega}$이였으며, TCR은 -1.5%/$^{\circ}C$로 나타났다. 열처리 온도가 증가함에 따라 TCR 값은 증가하였으며, 열처리 시간이 증가할수록 역시 TCR 값이 증가하는 경향을 보였다. 열처리 온도 320$^{\circ}C$, 열처리 시간 40 min에서 TCR 값은 약 -2%/$^{\circ}C$의 값을 얻을 수 있었다. 이러한 성능의 VOx 박막을 이용하여 비냉각형 microbolometer 검출소자를 열변형없이 공정을 수행할 수 있을 것으로 기대한다.

  • PDF

Single-pixel Autofocus with Plasmonic Nanostructures

  • Seok, Godeun;Choi, Seunghwan;Kim, Yunkyung
    • Current Optics and Photonics
    • /
    • v.4 no.5
    • /
    • pp.428-433
    • /
    • 2020
  • Recently, the on-chip autofocus (AF) function has become essential to the CMOS image sensor. An auto-focus usually operates using phase detection of the photocurrent difference from a pair of AF pixels that have focused or defocused. However, the phase-detection method requires a pair of AF pixels for comparison of readout. Therefore, the pixel variation may reduce AF performance. In this paper, we propose a color-selective AF pixel with a plasmonic nanostructure in a 0.9 μ㎡ pixel. The suggested AF pixel requires one pixel for AF function. The plasmonic nanostructure uses metal-insulator-metal (MIM) stack arrays instead of a color filter (CF). The color filters are formed at the subwavelength, and they transmit the specific wavelength of light according to the stack period and incident angles. For the optical analysis of the pixel, a finite-difference time-domain (FDTD) simulation was conducted. The analysis showed that the MIM stack arrays in the pixels perform as an AF pixel. As the primary metric of AF performance, the resulting AF contrasts are 1.8 for the red pixels, 1.6 for green, and 1.5 blue. Based on the simulation results, we confirmed the autofocusing performance of the MIM stack arrays.