• Title/Summary/Keyword: ray.

Search Result 20,659, Processing Time 0.038 seconds

Ultra Broadband Indoor Channel Measurements and Calibrated Ray Tracing Propagation Modeling at THz Frequencies

  • Priebe, Sebastian;Kannicht, Marius;Jacob, Martin;Kurner, Thomas
    • Journal of Communications and Networks
    • /
    • v.15 no.6
    • /
    • pp.547-558
    • /
    • 2013
  • Ultra broadband communication systems operated at THz frequencies will require the thorough knowledge of the propagation channel. Therefore, an extensive measurement campaign of 50 GHz wide indoor radio channels is presented for the frequencies between 275 and 325 GHz. Individual ray paths are resolved spatially according to angle of arrival and departure. A MIMO channel is recorded in a $2{\times}2$ configuration. An advanced frequency domain ray tracing approach is used to deterministically simulate the THz indoor propagation channel. The ray tracing results are validated with the measurement data. Moreover, the measurements are utilized for the calibration of the ray tracing algorithm. Resulting ray tracing accuracies are discussed.

Studies on Nanostructured Amorphous Carbon by X-ray Diffraction and Small Angle X-ray Scattering

  • Dasgupta, K.;Krishna, P.S.R.;Chitra, R.;Sathiyamoorth, D.
    • Carbon letters
    • /
    • v.4 no.1
    • /
    • pp.10-13
    • /
    • 2003
  • The structural studies of amorphous isotropic carbon prepared from pyrolysis of phenol formaldehyde resin have been carried out using X-ray diffraction. X-ray diffraction from as prepared sample at $1000^{\circ}C$ and a sample treated at $1900^{\circ}C$ revealed that both are amorphous even though there are small differences in short range order. It is found that both are graphite like carbon (GLC) with predominantly $sp^2$ hybridization. Small angle X-ray scattering results show that as prepared sample mainly consists of thin two dimensional platelets of graphitic carbon whereas they grow in thickness to become three dimensional materials of nano dimensions.

  • PDF

Determination of Thin Film Thickness by EDS Analysis and its Modeling (EDS 분석과 모델링에 의한 박막두께 측정 방법에 관한 연구)

  • Yun, Jae-Jin;Lee, Won-Jong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.8
    • /
    • pp.647-653
    • /
    • 2011
  • In this study, a method to measure the thickness of thin film by EDS (energy dispersive spectroscopy) is suggested. We have developed a model which calculates the thickness of thin film from the characteristic x-ray intensity ratio of the elements in thin film and substrate by considering incident electron beam energy, x-ray generation curve, backscattering and absorption of x-ray, take-off angle of x-ray and tilt angle of the sample. We obtained the relation curve between the film thickness measured experimentally and the x-ray intensity ratio of elements. The film thicknesses calculated from the model agrees quite well with those measured experimentally. Therefore, the thin film thickness can be measured rapidly and accurately by using the model developed in this study and the x-ray intensity ratio obtained in EDS analysis.

Fast Computation of Projection Image Based on the Repeated Patterns of Intersection between Ray and Voxel (Ray와 Voxel 교차 길이 반복성 기반 고속 Projection 영상 생성 기법)

  • Lee, Hyunjeong;Kim, Jeongtae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.942-948
    • /
    • 2017
  • Ray-tracing based method for computing projection image calculates the exact amounts of the intersection between voxels and a ray. Among several different implementations of the ray tracing based methods, Siddon's method is the earliest one. Later faster implementation such as Jacobs's method, Zhao's method, were investigated. To our knowledge, Zhao's method is the fastest one among these. We improve the speed of the Zhao's method by predicting the number of the same intersection length between voxel and a ray. In our experiment, the proposed method showed significantly faster computation speed than Zhao's method.

The Study on Measurement of Relative Conversion Factor in X-ray Image Intensifier (X선영상증배관의 상대변환계수 측정에 관한 검토)

  • Kim, Sung-Chul;Shin, Sung-Ill;Lee, Sun-Sook;Huh, Joon;Kim, Sung-Soo
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.28-33
    • /
    • 1997
  • For the Evaluation of X-ray image intensifier, we measured radiation dose at input of I. I., brightness and fluorescence at output of I. I. by using X-ray exposure meter, optometer and fluorescence meter for the relative conversion factor. Especially, by using fluorescence meter, we could easily get relative conversion factor without having regulated machine by JIS. Since using, the quality of image intensifier is going down. Consequently, it needs continuous quality maintenance.

  • PDF

Analysis of Rolling Contact fatigue for PM-High Speed Steel by X-ray Diffraction (X선회절에 의한 분말 고속도공구강의 구름접촉피로 해석)

  • 이한영;노정균;배종수;김용진
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.44-49
    • /
    • 2000
  • Recently, PM-high speed steel(PM-HSS) has reportedly been a good alternative material for rolling mill because of its superior peformance to conventional HSS. This paper has been aimed to investigate the possibility for application to rolling contact element for PM-HSS by X-ray diffraction technique. The X-ray elastic constant for PM-HSS has been found by X-ray diffraction during the four-point bending test. Residual stress and half-value breadth on the contact surface during rolling contact fatigue process by X-ray diffraction have also been measured. The result of this study shows that the application of X-ray diffraction technique to PM-HSS could be as possible alternative material as conventional HSS. Half-value breadth on rolling contact surface by X-ray diffraction is not changed during rolling contact fatigue process. On the other hand, the residual stress is changed. This suggests that dislocation reaction has been hardly occurred in rolling contact, depending on supersaturated carbon in PM-HSS.

  • PDF

X-Ray Security Checkpoint System Using Storage Media Detection Method Based on Deep Learning for Information Security

  • Lee, Han-Sung;Kim Kang-San;Kim, Won-Chan;Woo, Tea-Kun;Jung, Se-Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.10
    • /
    • pp.1433-1447
    • /
    • 2022
  • Recently, as the demand for physical security technology to prevent leakage of technical and business information of companies and public institutions increases, the high tech companies are operating X-ray security checkpoints at building entrances to protect their intellectual property and technology. X-ray security checkpoints are operated to detect cameras and storage media that may store or leak important technologies in the bags of people entering and leaving the building. In this study, we propose an X-ray security checkpoint system that automatically detects a storage medium in an X-ray image using a deep learning based object detection method. The proposed system consists of an edge computing unit and a cloud-computing unit. We employ the RetinaNet for automatic storage media detection in the X-ray security checkpoint images. The proposed approach achieved mAP of 95.92% on private dataset.

HARD X-RAY PULSATIONS IN GX 1+4

  • AGRAWAL P. C.;PAUL B.;RAO A. R.;CHANDA R. K. MAN
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.219-221
    • /
    • 1996
  • The x-ray pulsar GX 1+4 was observed by us in four balloon- borne experiments carried out from Hyderabad, India during 1991-1995 period with a hard x-ray telescope. The x-ray telescope consists of two collimated large area xenon-filled proportional counters with an effective area of $2400 cm^2$, a field of view of $5^{\circ}{\times}5^{\circ}$ and sensitive in the energy band of 20 - 100 keV. The pulsar was detected in bright state in two of the four experiments and x-ray pulsations with 120 second period were detected clearly. Pulsation period, rate of change of period with time, pulse fraction, pulse profile and energy spectra of the source were determined from these studies. During March 1995 observation, the x-ray pulse of GX 1+4 was found to be double-peaked compared to a single-peak pulse profile detected in December 1993. Details of these results are presented and their interpretation discussed in terms of the current accretion models of x-ray binaries.

  • PDF

Skin and Bone Segmentation Technique Using Dynamic Gaussian Filter Based on High Frequency Components in X-Ray Images (X-Ray 영상에서 고주파 성분 기반 동적 가우시안 필터를 이용한 피부와 뼈 영역 분할 기법)

  • Nam, Youn-man;Park, Tae-eun;Kim, Ju-wan;Song, Doo Heon;Kim, Kwang-baek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.137-140
    • /
    • 2021
  • 본 논문에서는 X-Ray 영상에서 발 뼈의 골절 영역을 분석 및 진단하기 위한 전단계로서 X-Ray 영상에서 뼈와 피부 영역을 분할하는 방법을 제안한다. 제안된 방법은 X-Ray 영상의 피부 영역과 발 뼈 영역을 분할하기 위해 가우시안 필터를 적용하여 DOG 영상을 생성한다. 그러나 기존의 가우시안 필터는 정적으로 적용되기 때문에 영상을 촬영하는 부위와 각도에 따라 영상의 특성이 달라지는 X-Ray 영상에 적용하기에 부적합하다. 따라서 부위와 각도에 따라 영상의 특성 변화에 민감하지 않는 동적 가우시안 필터를 제안한다. 실험 결과에서는 제안하는 동적 가우시안 필터와 기존의 정적인 가우시안 필터를 각각 적용하여 생성된 DOG 영상에 대해서 발 뼈 영역과 피부 영역을 분할하고, 효율성을 TPR과 특이도로 분석한 결과, 제안된 동적 가우시안 필터를 적용한 방법이 정적 가우시안 필터보다 평균적으로 TPR는 0.12%와 특이도는 평균적으로 0.36%가 개선된 것을 확인하였다.

  • PDF

Studies on the Wood Rays in Coniferous Woods - Mutural Relation on the Indicators of Wood Rays in Coniferous Woods - (침엽수재(針葉樹材)의 방사조직(放射組織)에 관(關)한 연구(硏究) - 방사조직지표치(放射組織指標値)의 상호관련성(相互關聯性)-)

  • Lee, Weon-Yong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.90-98
    • /
    • 1987
  • In the present paper I described the relations of wood ray indicators such as ray height, ray width, number of rays per $0.25mm^2$, ray spacing and fusiform ray height on the stem of Pinus koraiensis and Larix leptolepis grown at the Experiment Forest of Kangweon National University. The results may be summarized as follows. 1. The number of rays and ray spacing were generally decreased with the increase of ray height on the sample woods. 2. According to the tree species the patterns of varition of ray width with the increase of ray height were different, namely the relation between ray width and ray height showed some positive correlation on Pinus koraiensis and negative on Larix leptolepis. 3. It was recognized that the variation of fusiform ray height due to the increase of ray height indicated two patterns(the increasing, md constant regions) in sample woods. This boundary seemed to appear at six cells of ray height on Pinus koraiensis and ninc cells on Larix leptolepis. 4. The relation between fusiform ray height and number of rays had a negative correlation on Pinus koraiensis, but this tendancy was not obvious on Larix leptolepis. And ray spacing and ray width due to the increase of fusiform ray height were generally decreased. 5. On the whole the values of ray spacing and ray width became gradually larger in proportion to the increase of number of rays. 6. According to the increase of ray spacing the values of ray width also increased gradually. But this tendency was more clear on Pinus koraiensis than larix leptolepis.

  • PDF