• Title/Summary/Keyword: ray number

Search Result 1,137, Processing Time 0.029 seconds

Comparative Analysis of Fluctuating Asymmetry between Ploidy and Sex in Marine Medaka, Oryzias dancena

  • Park, In-Seok;Gil, Hyun Woo
    • Development and Reproduction
    • /
    • v.22 no.3
    • /
    • pp.275-281
    • /
    • 2018
  • The purpose of this study is to examine fluctuating asymmetry of eye diameter, maxilla length, operculum length, and the number of pectoral fin ray and pelvic fin ray between ploidy and sex in diploid and triploid marine medaka, Oryzias dancena. In all experimental groups, eye diameter and maxilla length showed no significant difference between left side and right side (p>0.05). Results of operculum length in triploid male group and pectoral fin ray's number in diploid male group showed similarity ones with results of operculum length in triploid female group and pectoral fin ray's number in diploid female group (p<0.05). However, the operculum length in diploid male group and pectoral fin ray's number in triploid male group showed consinderable difference with those of operculum length in diploid female group and pectoral fin in triploid female group. Findings of pelvic fin ray's number in all groups were similar to those of pectoral fin ray's number in all groups (p<0.01).

A Study on Activities of Diagnostic X-ray Examination(II) (X선진단(X線診斷) 부문(部門)에 있어서 업무량(業務量)에 관(關)한 조사연구(調査硏究)(II))

  • Kyong, Kwang-Hyon;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.1 no.1
    • /
    • pp.44-54
    • /
    • 1978
  • This study was carried out with statistical materials during the last two years of period from Jan. 1975 to Dec. 1976 which presented at radiologic department of 5 hospitals in Seoul City. The primary purpose of this study was to obtained more detailed informations related to the activities of radiologic technologists in diagnostic X-Ray examinations part and to provide some basic materials for managements in activities of then and manpower managements of their organization and practice. From the results of this study, the following conclusions were obtained [1] During two year from the January of 1975 to the December of 1976, total number of case in X-ray examinations were 464,830 case and 22,029 case in 1975 and 24,461 in 1976. And ratio of icreased in X-Ray examinations by year was 11.09 per cent. [2] Regarding the examined portion of X-Ray examination, a great propotion was chest examination as 56.88 per cent. [3] An average, the required time per case in X-Ray exam. was 9.28 minutes and make used of 1.94 sheets of X-Ray film per case in radiography. [4] An average, ratio of increased in X-Ray film by year was 12.71 per cent and ratio of failed film in it was 2.23 per cent. [5] The frequency rate of film size showed the highest distribution of $8"{\times}10"$(28.17%) and the highest distribution of X-Ray film by month was July(8.93%). [6] An average, the amount of activities per a diagnostic X-Ray equipment was 34.92 case and make used of 67.81 sheets of X-Ray film in a day. [7] The mean number of case in X-Ray examinations by radiologic technologists was 29.29 cases and make used of 56.87 sheets of X-Ray film in a day. Also, the average number of case was reading by radiologists was 32.42 case and 62.97 sheets of X-Ray film in a day.

  • PDF

Micro Structural Changes in Juvenile and Matured Wood of Populus tomentiglandulosa T. Lee

  • Lu, Sun;Ahmed, Sheikh Ali;Chong, Song-Ho
    • Journal of the Korea Furniture Society
    • /
    • v.17 no.3
    • /
    • pp.29-36
    • /
    • 2006
  • Juvenile and matured wood of Populus tomentiglandulosa species of Salicaceae native grown in Korea was observed by FE-SEM and optical microscope. Species is characterized by mostly diffuse-porous, simple perforation plates, polygonal alternate non-vestured intervessel pit, medium length of vessel elements and fibres, non-septate very thin walled libriform fibres and exclusively uniseriate procumbent rays. Axial parenchyma was absent or extremely rare. Vessel and fibre length were longer in both matured and juvenile latewood than those of earlywood. Ray cell lumen diameter, ray length, number and diameter of endwall pit in ray cell, endwall pit, number and diameter of pit in lateral wall of one ray parenchyma cell, vessel ray pit number and diameter vary from juvenile early and latewood to matured wood.

  • PDF

The Representation of 3-D Objects Using Ray Tracing and Space Subdivision (광선 추적법과 공간 분할을 이용한 입체 도형의 표현)

  • Kim, Y.I.;Cho, D.U.;Choi, B.U.
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1073-1076
    • /
    • 1987
  • In this paper, a new ray tracing algorithm which uses space subdivision method is introduced. In order to reduce huge number of ray-surface intersection calculation, the space is subdivided as lattice that contains minimum number of objects. With lattice structure, the process that calculates unnecessary ray-surface intersection is eliminated.

  • PDF

Cambial Activity and Development of Rays in the Stem of Robinia pseudo-acacia L. (아카시아나무의 줄기에 있어서 형성층의 활동과 방사조직의 발생)

  • 한경식
    • Journal of Plant Biology
    • /
    • v.33 no.1
    • /
    • pp.65-72
    • /
    • 1990
  • An anatomical study was conducted in order to elucidate the development of primary and secondary ray in Robinia pseudoacacia L. The height of primary ray near pith decreases progressively toward periphery, while the width and number per unit area gradually increase, and then the height, width and number remain somewhat constant. Secondary ray originates from the segmentation of fusiform initials or division of the side or end of fusiform initials at the middle of the first growth layer. And after the height and width of secondary ray increases to some extent, it remains constantly.

  • PDF

Automatic ray-code generation for efficient ray tracing (효율적인 파선추적을 위한 파선코드 자동 생성에 관한 연구)

  • 이희일
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.55-62
    • /
    • 2000
  • In constructing a synthetic seismogram using ray-tracing method a suite of ray-code is required to obtain a realistic seismogram which is similar to the actual seismogram or earthquake record under consideration. An infinite number of rays exist for any arbitrarily located source and receiver. One select only a finite number of such rays in computing a synthetic seismogram so their selection becomes important to the validity of the seismogram being generated. Missing certain important rays or an inappropriate selection of ray-codes in tracing rays may result in wrong interpretation of the earthquake record or seismogram. Automatic ray-code generation will eliminate such problems. In this study we have developed an efficient algorithm, with which one can generate systemastically all the ray-codes connecting source and receiver arbitrarily located. The result of this work will helpful in analysing multiple reflections in seismic data processing as well as simulating Lg wave and multiply reflected or converted phases in earthquake study.

  • PDF

Charge Transport Characteristics of a-Se based X-ray Detector (비정질 셀레늄 기반의 X선 검출 센서의 전하 수송 특성)

  • Kang, Sang-Sik;Cha, Byung-Youl;Jang, Gi-Won;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.375-378
    • /
    • 2002
  • There has recently been a great deal of interest in amorphous selenium for application of digital x-ray image sensor. The initial number of the electron-hole induced by interaction a-Se with x-ray photons and the collection efficiency to surface of generated charges are important parameters for x-ray sensitivity of the a-Se. Therefore, in this paper, we analyzed that thickness of a-Se film and electric field is affected on the initial number of electron-hole and the collection efficiency. The experimental value of x-ray induced charge about the various thickness and the electric field is compared with estimated absorbed energy through MCNP 4C code to analyze the mechanism x-ray induced signal of a-Se. The experimental results showed that the electric field depends on initial escape coefficient and the thickness depends on collection coefficient than escape efficient.

  • PDF

Safranine Penetration Path Observed by Optical Microscope in Four Korean Pine Wood Species

  • Chong, Song-Ho;Ahmed, Sheikh Ali;Chun, Su-Kyoung
    • Journal of the Korea Furniture Society
    • /
    • v.18 no.2
    • /
    • pp.138-142
    • /
    • 2007
  • Optical microscope was used to observe the difference of safranine penetration in Pinus densiflora, Pinus rigida, Pinus koraiensis and Larix kaempferi grown in Korea. It was found that Pinus koraiensis contained the highest number of ray parenchyma and ray tracheids. In longitudinal direction, latewood penetration was found higher than that of earlywood. The number of resin canals was found highest in Pinus koraiensis and lowest in Pinus rigida. The resin canal conducted safranine higher than longitudinal tracheids. In longitudinal direction, safranine diffused from longitudinal tracheid to ray parenchyma through the cross-field pits and from the longitudinal resin canal to ray parenchyma or longitudinal tracheid. Safranine diffused from longitudinal tracheid to its neighboring tracheid through bordered pit or ray parenchyma through the cross-field pits.

  • PDF

X-ray Computed Tomography on Larger Diameter Timber than Digital Detector

  • Kim, Chul-Ki;Lee, Jun-Jae;Oh, Jung-Kwon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.5
    • /
    • pp.385-391
    • /
    • 2013
  • X-ray computed tomography is a very powerful nondestructive technique in safety inspection of historic timber building. But, in field, various testing condition makes it difficult to carry out X-ray CT testing. Limited size in X-ray digital detector is one of the problems. In this study, a pitch pine disk with two holes was used to know how imperfection in X-ray projection affects CT image resolution. Using various number of projections, CT image was reconstructed by filtered back projection method, and then it was investigated how many projection is required to identify the holes in different location. Two artificial holes could be differently detected according to their location in cross section of specimen. One hole in center part of specimen was identified using more than 9 radiographs, but the other one which located in outer part of cross section could not be detected until more than 36 projections were used. Even though there is data missing in outer part of cross section due to limited size of detector, the center part of CT image could be reconstructed well and the resolution of outer part became higher with increase of the number of projections. For field application, the number of projections for CT image reconstruction needs to be decided with consideration of another nondestructive testing and the location of interest.