• 제목/요약/키워드: raw water quality

검색결과 504건 처리시간 0.024초

화장품(化粧品)에서 알코올성(性) 화장수(化粧水)의 안정도(安定度)에 관(關)한 연구(硏究) (A study on the stability of alcohlic toilet water in cosmetics)

  • 성기천;김기준;이후설
    • 한국응용과학기술학회지
    • /
    • 제14권1호
    • /
    • pp.45-52
    • /
    • 1997
  • It is the problem point of stability for this study to produce cosmetics and to occur in the circulation process, and specially in a case of alcoholic toilet water the precipitation materials to float on content materials has study on the solubility of perfume, and it has practiced in order to examine the problem point whether the raw materials of plastic vessel is or not harmful in content materials. In testing result, A study on stability of alcoholic toilet water is above all the precipitation materials which floats in content materials, and It is appeared by combination ratio to the raw materials of perfume, ethanol, solubilizer and refining water etcs, and in second the alkali degree which has gushed out of glass vessel can understand the thing that the change of PH is largely increased following to the passage of time, and in third the harmful component of content materials out of raw material in plastics vessel must certainly consider a stability and a safety in quality control of products.

감마선 처리를 이용한 고무공장 폐수의 생물독성 저감 (Toxicity Reduction of Wastewater from a Rubber Products Manufacturing Factory by Gamma-ray Treatment)

  • 박은주;조훈제;조기종;김정규;정진호
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.913-918
    • /
    • 2006
  • Both raw wastewater and effluent from a rubber products manufacturing factory were found to be toxic to Daphnia magna though the effluent satisfied current water quality standards. Thus, in order to reduce toxicity, advanced oxidation processes (AOPs) such as gamma-ray (${\gamma}-ray$) treatment and ozonation ($O_3$) were applied. A combined ${\gamma}-rays/O_3$ treatment at 20 kGy after coagulation significantly reduced toxicity of raw wastewater, changing 48-h toxic unit (TU) value from 201.21 to 23.92. However, toxicity of treated water was higher than that of effluent (TU = 12.15). This shows limitation of gamma-ray treatment to remove toxicity of raw wastewater. In case of effluent, the combined ${\gamma}-rays/O_3$ treatment at 20 kGy efficiently decomposed toxic compounds down to non toxic level. This work strongly supports the necessity of toxicity reduction evaluation as well as toxicity-based effluent management.

수돗물 위해요소 리스크 관리를 위한 물안전계획 적용 연구 (A study on the application of water safety plans for the hazard risk management of tap water)

  • 김진근;김두일
    • 상하수도학회지
    • /
    • 제33권4호
    • /
    • pp.259-268
    • /
    • 2019
  • One of the most effective methods to consistently ensure the safety of a tap water supply can be achieved by application of a comprehensive risk assessment and risk management approach for drinking water supply systems. This approach can be termed water safety plans(WSP) which recommended by WHO(world health organization) and IWA(international water association). For the introduction of WSP into Korea, 150 hazards were identified all steps in drinking water supply from catchment to consumer and risk assessment tool based on frequency and consequence of hazards were developed. Then, developed risk assessment tool by this research was implemented at a water treatment plant($Q=25,000m^3/d$) to verify its applicability, and several amendments were recommended; classification of water source should be changed from groundwater to stream to strengthen water quality monitoring contaminants and frequencies; installation of aquarium to monitor intrusion of toxic substances into raw water; relocation or new installation on-line water quality analyzers for efficient water quality monitoring; change of chlorination chemical from solid phase($Ca(OCl)_2$) to liquid phase(NaOCl) to improve soundness of chlorination. It was also meaningful to propose hazards and risk assessment tool appropriate for Korea drinking water supply systems through this research which has been inconsistent among water treatment authorities.

Smart Water Quality Sensor Platform For Hydroponic Plant Growing Applications

  • Nagavalli, Venkata Raja Satya Teja;Lee, Seung-Jun;Lee, Kye-Shin
    • Journal of Multimedia Information System
    • /
    • 제5권3호
    • /
    • pp.215-220
    • /
    • 2018
  • This work presents a smart water quality sensor for hydroponic plant growing applications. The proposed sensor can effectively measure pH level and electrical conductivity of the water solution. The micro-controller incorporated in the sensor processes the raw sensor data, and converts it into a readable format. In addition, through the mobile interface realized using a WiFi module, the sensor can send data to the web server database that collects and stores the data. The data stored in the web server can be accessed by a personal computer or smart phone. The prototype sensor has been implemented, and the operations have been verified under an actual hydroponic plant growing application.

Effect of Reservoirs on Microbiological Water Qualities in a Drinking Water Distribution System

  • Lee Dong-Geun;Kim Sang-Jong;Park Seong-Joo
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권7호
    • /
    • pp.1060-1067
    • /
    • 2006
  • This study was undertaken to determine the effect of reservoirs on water quality and the distribution of pathogenic and indicator bacteria in a drinking water distribution system (total length 14km). Raw water, disinfected water, and water samples from the distribution system were subjected to physicochemical and microbiological analyses. Most factors encountered at each season included residual chloride, nitrate, turbidity, and phosphorus for heterotrophic bacterial distribution, and hardness, heterotrophic bacteria, sampling site, and DOC (dissolved organic carbon) for bacteria on selective media. No Salmonella or Shigella spp. were detected, but many colonies of opportunistic pathogens were found. Comparing tap water samples taken at similar distances from the water treatment plant, samples that had passed through a reservoir had a higher concentration of heterotrophic bacteria, and a higher rate of colony formation with 10 times as many bacteria on selective media. Based on the results with m-Endo agar, the water in reservoirs appeared safe; however, coliforms and opportunistic pathogenic bacteria such as Pseudomonas aeruginosa were identified on other selective media. This study illustrates that storage reservoirs in the drinking water distribution system have low microbiological water quality by opportunistic pathogens, and therefore, water quality must be controlled.

Reuses Of Wash Water Effluents Of The Ion-Exchanger Units Of Water Demineralization Plant For Economic And Environmental Benefits

  • Miah, Raisuddin
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.799-806
    • /
    • 1995
  • In industrial field, a large volume of regenerants (acid and caustic soda) and their washing effluents are regularly disposed off from the water demineralization plant during regeneration of the ion-exchanger units. Of these waste effluents, a part of the wash water discharged from the single bed Anion and Mixed Bed units can be utilized at a certain stage of their washing cycles when its conductivity is fallen down and becomes considerably less than that of the input raw water. The main aim of this specific waste effluent utilization is to dilute the TDS concentration of the input raw water (fed into the single bed ion-exchanger units) by blending. The achievement is the increase of the longevity of the production cycles of the I.E. units along with the improvement of the production quality and decrease of the regeneration frequencies. As a result, regenerant consumption would be saved because of the reduction of ionic load in feed water which will ultimately reduce the water purification cost. At the same time, the environment pollution will also be protected to a considerable extent. This operational measure is quite effective and useful specially where high TDS water is demineralized only by single bed ion-exchangers. In such case, the water treatment plant is very often found to suffer from both production quality and quantity in addition to carrying out of random and restless regenerations. Proper reuses of the aforesaid wash water effluents of the Anion and MB units excellently minimizes the difficulties experienced in practice. This paper contains the utilities and techniques of reuses of the different kinds of waste effluents of the industrial water treatment plant in addition to the specific reuses of the post-regeneration wash waters of the Anion and MB ion-exchanger units.

  • PDF

막여과 정수처리공정에서 전여과공정의 효용성 평가 (Utility Estimation of Pre-filtration on the Membrane Water Treatment Process)

  • 박민구;최상일
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.445-448
    • /
    • 2008
  • The application of the membrane filtration process has been increased for the drinking water treatment system because of excellent quality of treated water compared with the sand filtration process. The selection of suitable pre-treatment processes and optimum flux according to the characteristics of raw water are important factors for the design of membrane processes. In this study, the most efficient pre-treatment processes for drinking water was selected by investigating the effects of pre-treatment processes on the operational stability of the membrane filtration process. Both lab-scale and pilot-scale experiments were conducted. In the lab-scale test, the effect of pre-treatment processes on the stability of the membrane filtration process was investigated indirectly by comparing the performance of membrane flux for raw water, pre-treated water, and membrane permeated water. In the pilot-scale test, the usefulness of prefiltration processes was assessed by comparing the performance of single membrane process and hybrid coagulation-membrane process. The results indicated that the coagulation process contributed to the stabilization of trans-membrane pressure (TMP) by removing contaminants on membranes, though the pre-filtration process had little effect on the TMP.

Gum류를 첨가한 우육 Patty의 품질 특성 (Quality Characteristics of Beef Patty Containing Gums)

  • 정인철;김도완;이경수
    • 동아시아식생활학회지
    • /
    • 제10권5호
    • /
    • pp.403-410
    • /
    • 2000
  • In order to investigate the possibility of lwo fat meat products, beef patties were prepared with gums such as carrageenan, methyl cellulose, and xanthangum. The quality characteristics of beef patties were examined. Moisture contents of raw and cooked patties of control were lower than those of patties containing gums, and fat content was higher than those of containing gums. There was no significant difference in the protein contents of patties. In case of L-value(lightness) of raw patty, the control was higher than those patties containing gums. a-(redness) and b-value(yellowness) among patties were not significantly different. Cooking yield, fat retention, and water holding capacity of beef patties containing gums were higher than control beef patty, but salt soluble protein and gel strength were not significantly different. Significant difference did not exist among beef patties in hardness, but the chewiness and gumminess of patties containing gums were higher than control. In case of sensory evaluation, there was no significant difference among patties in aroma and palatability. Texture of control was higher than patties containing gums, and juiciness of control was higher than patties containing carrageenan.

  • PDF

영산강 유역의 유출량 및 수질자료에 대한 비선형 동역학과 웨이블렛 이론의 적용 (Application of Nonlinear Dynamics and Wavelet Theory for Discharge and Water Quality Data in Youngsan River Basin)

  • 오창열;진영훈;박성천
    • 한국물환경학회지
    • /
    • 제23권4호
    • /
    • pp.551-560
    • /
    • 2007
  • The present study analyzed noise reduction and long/short-term components for discharge, TOC concentration, and TOC load data in order to understand the data characteristics better. For the purpose, wavelet transform which can reduce noise from raw data and has flexible resolution in time and frequency domain was applied and the theory of nonlinear dynamics was also used to determine the last decomposition level for wavelet transform. Wavelet function of 'db10' and the 7th level for the last decomposition of wavelet transform were applied for the all data in the present study. Also the results revealed that the energy ratios of approximation components with 187-hour periodicity decomposed from 7th level of wavelet transform were 94.71% (discharge), 99.00% (TOC concentration), and 93.84% (TOC load), respectively. In addition, the energy ratios of detail components showed the range between 1.00% and 6.17%, which were extremely small comparing to the energy ratios of approximation components, therefore, the first and second detail components might be considered as noise components included in the raw data.

범람/휴지식 홍수터여과에서 폐색현상 및 수질개선도 연구 (A Study on Clogging and Water Quality Improvement in Floodplain Filtration with Flood/rest Raw-water Supply)

  • 김호석;김승현
    • 대한환경공학회지
    • /
    • 제33권2호
    • /
    • pp.120-131
    • /
    • 2011
  • 하수처리장 방류수를 추가로 처리하여 하천의 수질을 개선하려는 노력의 일환으로 범람/휴지식 홍수터여과에 대한 파일럿 규모의 실험을 수행하였다. 대상토양은 낙동강의 구미, 대구, 그리고 김해에서 얻었으며, 각 토양별로 운전경과에 따른 침투율 감소현상과 여러 침투율에서 각종 오염물질의 여과거리에 따른 제거율을 조사하였다. 실험결과 운전시간이 경과함에 따라 표층에서 폐색이 점차 발달하였고 이에 따라 침투율이 지수함수적으로 감소하였다. 표층의 폐색제거에 필요한 주기는 모든 토양에서 2주 이상이었고, 안정적인 침투율은 구미토양의 경우 5 m/day, 대구와 김해 토양의 경우에는 1 m/day이었다. 불포화대에서는 여과거리 증가에 따라 용존산소의 농도가 오히려 증가하여 범람/휴지를 번갈아 적용하는 방식이 토양을 호기환경으로 유지하는데 효과적임을 알 수 있었다. 모든 토양에서 침투율이 증가하여도 여과거리에 따른 오염제거특성은 거의 일정하였다. BOD와 탁도는 모든 토양의 여과거리 1.2 m에서 대부분 제거가 가능하였으며, COD는 3.6 m 여과에서 30% 이상 제거되었고 여과거리가 증가하면 그 제거율이 다소 향상될 것으로 예상되었다. 모든 토양의 표층부근에서 질산화반응이 진행되었으나 실험된 여과거리에서는 질소의 제거가 거의 없었다. 구미토양에서는 인 제거율이 낮았으나 다른 토양에서는 인 제거율이 상당하거나 매우 높아서 본 공법을 잘 활용하는 경우 하천수질을 크게 개선할 수 있을 것으로 기대되었다.