• 제목/요약/키워드: raw water quality

검색결과 505건 처리시간 0.024초

Effect of Ozone Treatment for Nakdong River Raw Water I. Efficiency of Water Treatment by Conducting Batch Test of Ozonation Experiments (낙동강 상수원수의 오존처리 효과 I. 회분식 오존처리에 의한 수처리효과)

  • 조주식;임영성;이홍재;허종수
    • Journal of Environmental Science International
    • /
    • 제10권6호
    • /
    • pp.393-399
    • /
    • 2001
  • This study was carried out to evaluate the pollutant removal efficiencies of the advanced drinking water treatment using ozonation. for raw water, Nakdong River was used. By conducting batch ozonation test, the following results were obtained. when ozone dosage of 5mg/$\ell$was used, preozonation of raw water reduced turbidity, KMnO$_4$consumption, DOC(dissolved organic carbon), UV254 absorbance, THMFP(trihalomethane formation potential) as much as 3.9NTU, 5.5mg/$\ell$, 1.15mg/$\ell$, 0.112 and 0.065mg/$\ell$, respectively. In case of postozonation of sand filtered water, water quality was also improved with decrease in turbidity, KMnO$_4$consumption, DOC, UV254 absorbance and THMFP at the amount of 0.08NTU, 2.6mg/$\ell$, 0.88mg/$\ell$, 0.042 and 0.018mg/$\ell$, respectively. On the other hand, contents of dissolved oxygen increased at the level of 1.3mg/$\ell$ after preozonation process and 1.0mg/$\ell$ after postozonation process. The effect of ozone dosage was higher than that of its contact time for the removal of the pollutants.

  • PDF

Analysis of the sludge thickening characteristics in the thickener using CFD Model (CFD를 이용한 농축조 슬러지의 유출흐름특성 해석)

  • Park, No-Suk;Moon, Yong-Taik;Kim, Byung-Goon;Kim, Hong-Suck
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제25권5호
    • /
    • pp.777-782
    • /
    • 2011
  • The residual treatment facilities in WTP(water treatment plant) play an important role in solid-liquid separation. At present, it is difficult to solve problems related with thickening and dewatering of WTP sludge, and discharging waste water to river. The quantity of residuals generated from water treatment plants depends upon the raw water quality, dosage of chemicals used, performance of the treatment process, method of sludge removal, efficiency of sedimentation, and backwashing frequency. Sludge production by the physical separation of SS(Suspended Solid) occurs under quiescent conditions in the primary clarifier, where SSs are allowed to settle and to consolidate on the clarifier bottom. Raw primary sludge results when the settled solids are hydraulically removed from the tank. In this study, Drawing characteristics of the sludge thickening in the thickener of Water Treatment Plants was simulated by Using CFD(Computational Fluid Dynamics.

The Study on the Ion Water Characteristics of Raw Water in the Domestic Natural Mineral Water (국내 유통 중인 먹는샘물 원수의 이온류 수질 특성에 관한 연구)

  • Lee, Leenae;Ahn, Kyunghee;Min, Byungdae;Yang, Mihee;Choi, Incheol;Chung, Hyenmi;Park, Juhyun
    • Journal of Korean Society on Water Environment
    • /
    • 제32권5호
    • /
    • pp.442-449
    • /
    • 2016
  • The goal of this study is to provide basic data to establish a foundation for the provision of safe drinkable water. The raw water of natural mineral water was analyzed to determine the quantities of anions (F-, Cl-, NO3-N-, and SO42- ) and cations (Ca2+, K+, Mg2+, and Na+) during the former and latter half of 2016. Analysis of the current quality of the raw water of natural mineral water among domestic manufacturers showed average anions contents of 0.46mg/L of fluorine, 8mg/L of chlorine ion, 1.5mg/L of nitrate nitrogen, and 12mg/L of sulfate ion. While the fluorine content was greater than the water quality criterion of 2.0mg/L at four points, the fluorine level was overall stable. The average cations contents included 21.3mg/L of calcium, 1.0mg/L of potassium, 3.4mg/L of magnesium, and 9.6mg/L of sodium. The chemical characteristics were compared among the major ions, and the results are presented in a piper diagram. The content ratio of cations was in the order of Ca2+> Na+>Mg2+>K+, whereas that of anions was in the order of SO42->Cl->NO3-N->F-. While the cations were slightly scattered, the anions were generally concentrated except for at a few points. The Ca-Na-HCO3 type was dominant overall in water sources from diorite, gneiss, and granite, while the Na-Mg-Ca-HCO3-Cl type was dominant in basalt sources. Mineral water manufacturers source their water under various conditions, including in-hole casing, excavation depth, and contact state of bedrock; even within the same rocky area, some differences in the water quality type can occur. When the depth of the water source was taken into account, the mean anions contents of F-, Cl-, NO3-N-, and SO42- were similar, with no significant differences according to depth. Of the cations, K+ and Na+ showed no significant differences across all the tubular wells, whereas Ca2+ and Mg2+ decreased in content with depth.

Quality Characteristics of Commercially Available Soybean and Mung-bean Flours in Korea (국내 유통 콩 및 녹두가루 제품의 품질 특성)

  • Woo, Koan Sik;Kim, Mi-Jung;Sim, Eun-Yeong;Kim, Hyun-Joo;Lee, Choon Ki;Jeon, Yong Hee
    • The Korean Journal of Food And Nutrition
    • /
    • 제30권5호
    • /
    • pp.1119-1126
    • /
    • 2017
  • Quality characteristics of commercially available soybean and mung-bean flours in Korea were evaluated relative to product information such as bean content, price, chromaticity, proximate composition, water binding capacity, swelling power and solubility. Origin of raw materials was 23 in domestic products and 19 in imported products. The price of the product was 3.48 times more for raw soybean flour, 3.34 times more for fried soybean flour, and 3.47 times more for mung bean flour compared to imported soybean. In the domestic products, the lightness of raw soybean flour was higher than roasted soybean flour. The redness and yellowness of roasted soybean flour were higher than raw soybean flour. Moisture content of raw soybean flour was higher than roasted soybean flour, and crude fat, crude protein and carbohydrate content were higher in imported soybean flour. Ash and crude protein contents of mung bean were slightly higher than imported products. Water binding capacity of roasted soybean flour in domestic products was higher than raw soy flour, and there was no significant difference in solubility and swelling power. Correlation between quality characteristics of commercially available soybean and mung-bean flours products was found to be highly significant among measured items, except for solubility.

Isolation and Characteristics of Humic Substances in Raw water of Chuncheon-City (춘천지역 상수원수 중 휴믹물질의 분리 및 특성)

  • Lee, Yu-Mi;Rhee, Dong-Seok
    • Journal of Industrial Technology
    • /
    • 제27권B호
    • /
    • pp.109-114
    • /
    • 2007
  • Humic substances generally comprise 30-50% of the dissolved organic carbon in water. They can affect water quality adversely in several ways and they are important from a water treatment perspective due to their role as precursors for the formation of chlorination by-products such as trihalomethanes. The objectives of this research are to investigate the characteristics of organic matter using raw water of Chuncheon area, to isolate the humic substance fractions from natural water samples, and characterize the extracted humic substances. Humic substances were fractionated according to "isolation of IHSS aquatic humic and fulvic acids" using XAD resin adsorption technique. Characteristics of humic substances were analyzed through DOC, $UV_{254}$, $SUVA_{254}$, FT-IR spectra, fluorescence analysis.

  • PDF

Water Quality Change Characteristics of Treated Water in Distribution System of Water Treatment Plant of Jeiu City (제주시 정수장 처리수의 급수과정별 수질변화 특성)

  • Han, Kyung-Yong;Lee, Min-Gyu;Chung, Ho-Jin;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • 제16권1호
    • /
    • pp.81-94
    • /
    • 2007
  • The purpose of this work is to investigate the water quality change characteristics of treated water in water distribution systems of Water Treatment Plants (WTPs) of Jeju City. For this, the raw water, treated water and tap water that did not pass (named as not pass-tap water) and passed through the water storage tank (named as pass-tap water) were sampled and analyzed monthly from September 2001 to August 2002, for four (W, S, B and O) WTPs except for D WTP (where treated water is not supplied continuously) among WTPs of Jeju City. The concentrations of $NO_3^-$ and $Cl^-$ of treated water in distribution systems changed little, but changed seasonally, which is considered to be based on the seasonal variation of the quality of raw water. The pH of treated water changed little in distribution systems for S WTP, but for the other WTPs, the pH of not pass-tap water was similar to that of treated water and the pH of pass-tap water was higher than that of treated water. The turbidity of treated water in distribution systems changed little except for W2 of W WTP and S4 and S5 of S WTP, where it was higher than that of each treated water. The residual chlorine concentrations between treated water and not pass-tap water changed little, but those between treated water and pass-tap water changed greatly, based on the its long residence time in water storage tank and so its reaction with organic matter, etc or its evaporation. The concentrations of TTHMs (total trihalomethanes) and $CHCl_3$ that induce cancers in water distribution systems of these WTPs, were much lower than their water quality criteria and those in other cities. The concentrations of TTHMs of treated water and not pass-tap water were similar, but concentrations of pass-tap water were 1.5 to 2.0 times higher than those of treated water and not pass-tap water, due to the reaction of residual chlorine and organic matter, etc, with the result of long residence time in water storage tank.

Effect of White Water Quality on AKD Sizing of Linerboard (백수의 수질에 따른 라이너지의 AKD 사이징)

  • Lee, Hak-Lae;Seo, Man-Seok;Shin, Jong-Ho;Youn, Hye-Jung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • 제38권2호
    • /
    • pp.9-15
    • /
    • 2006
  • Neutral sizing is required for linerboard to solve the troubles in strength and process caused by recycled raw materials. AKD sizing efficiency can be influenced by process condition like white water quality, fines retention and so on. Therefore, this study was aimed to evaluate sizing performance of general and fast cure type AKDs using process water obtained from linerboard mill. To evaluate effect of process water quality on AKD sizing, white water was diluted with tap water at the different dilution ratios and UKP slurry was sized using the prepared water. Also, effects of inorganic and organic ion material on sizing were examined. When white water was used for stock forming, UKP sheet showed very low sizing degree. Sizing degree of sheet was increased with increase of dilution ratio because water quality was improved. Especially anionic organic material had a greater influence on AKD sizing than inorganic material. When white water quality was deteriorated, fast cure type AKD showed superior sizing performance to general type AKD.

Consumer Attitudes Toward Storing and Thawing Chicken and Effects of the Common Thawing Practices on Some Quality Characteristics of Frozen Chicken

  • Benli, Hakan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제29권1호
    • /
    • pp.100-108
    • /
    • 2016
  • In this study, a survey was conducted to both evaluate the consumers' general attitudes for purchasing and storing the raw chicken and determine the thawing practices used for defrosting frozen chicken at home. About 75% of the consumers indicated purchasing chicken meat at least once a week or more. Furthermore, the majority (82.16%) of those who stored at least a portion of the raw chicken stated freezing the raw chicken meat at home. Freezing the chicken meat was considered to have no effect on the quality by 43.49% of the consumers while 56.51% thought that freezing had either negative or positive effects on the quality. The survey study indicated that top five most commonly used thawing practices included thawing on the kitchen counter, thawing in the refrigerator, thawing in the warm water, thawing in the microwave, and thawing under tap water. In addition, an experimental study was conducted to determine the effects of these most commonly used thawing practices on some quality characteristics of the chicken meat including pH, drip loss, cooking loss, color analysis and textural profile analysis. Although, $L^*$ value for thawing on the kitchen counter was the lowest, after cooking, none of the thawing treatments have a significant effect on the color values. Thawing in the microwave produced the highest drip loss of 3.47% while the lowest drip loss of 0.62% was observed with thawing in the refrigerator. On the other hand, thawing in the microwave and refrigerator caused the lowest cooking loss values of 18.29% and 18.53%, respectively. Nevertheless, there were no significant differences among textural parameter values of the defrosted and then cooked samples using the home based thawing practices, indicating similar quality characteristics among the samples.

Derivation of Optimal Conditions and Effect of Treated Water Quality for Treatment of Drinking Water using Inorganic Membrane (무기막을 사용한 먹는물 처리 시 최적의 조건 도출 및 처리수질에 미치는 영향)

  • Won, Chan-Hee
    • Journal of the Korean Society for Environmental Technology
    • /
    • 제19권6호
    • /
    • pp.543-549
    • /
    • 2018
  • In this study, the treatment efficiency of inorganic membrane according to the flux that blending raw water was investigated at the laboratory level. Based on the results of each blending and flux, we obtained the best efficiency according to each measurement item. The treatment efficiencies were different depending on the raw water and treatment amount of the treated water. Especially, turbidity removal efficiency was high. In the case of $UV_{254}$, the removal efficiency according to the concentration of the raw water and the removal efficiency according to the flux of the treated water showed a maximum of 69 % to minimum of 48 %. In the case of TOC and DOC, the processing efficiency was 22 % and 28 %, respectively, because the organic value of the raw water was low. These results suggest that there is an optimal process to effectively remove contaminants from the inorganic membrane process, and it is necessary to optimize it according to operating conditions.

Identification of operating parameters in auto-discharging filter system for treatment of urban storm water (자동방류가 가능한 여과형 비점오염처리장치의 운전인자 도출)

  • Kim, Sun-Hee;Gwon, Eun-Mi;Pak, Sung-Soon;Joh, Seong-Ju;Lim, Chea-Hoan;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제24권4호
    • /
    • pp.377-386
    • /
    • 2010
  • To identify operating parameters of the up-flow filtering system, which is available to discharge filtering residue after the rain, developed for treatment of urban storm runoff, lab scale test was carried out. Removal efficiency of SS was 68.7%, 62.2%, and 58.6% at the area roading rate of 2.46m/h, 4.68m/h, and 10m/h, respectively, filtering device is desirable to operate at the lower than 4.68m/h of area roading rate to get higher level of 60% SS removal efficiency. The removal efficiency of SS was 57.1% ~ 68.7% at the raw water SS of 100mg/L ~ 600mg/L, and the SS in treated water was maintained at the constant level through the elapsed time. It is indicate that filtering device can guarantee a certain level of effluent water quality at various raw water quality. The removal efficiency of SS to the depth of filter media was 68.3%, 78.6% at the filter depth of 10 cm, 20cm respectively. The final treated water quality was showed 30.2mg/L of CODMn, 1.60mg/L of TN and 0.25mg/L of TP. The average removal efficiencies by filtering device developed in this research were recorded slightly lower levels than other research. The main reason of these results were the first, the filter depth of the media used in this test was shallow, the second, the kind of filter media in discharge port of residue. More research to kind of filter media, filter packing rate, select of media for residue discharge port should be go on to produce optimum operating condition. The result of this study would be valuable for the application of filtration device to control of urban storm water.