• Title/Summary/Keyword: raw water quality

Search Result 504, Processing Time 0.037 seconds

Removal of High Concentration Manganese in 2-stage Manganese Sand Filtration (2단 망간모래여과에 의한 고농도 망간 처리)

  • Kim, Chung H.;Yun, Jong S.;Lim, Jae L.;Kim, Seong S.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.503-508
    • /
    • 2007
  • Small scale D-water treatment plant(WTP) where has slow sand filtration was using raw water containing high concentration of manganese (> 2mg/l). The raw water was pre-chlorinated for oxidation of manganese and resulted in difficulty for filtration. Thus, sometimes manganese concentration and turbidity were over the water quality standard. Two stage rapid manganese sand filtration pilot plant which can treat $200m^3/d$ was operated to solve manganese problem in D-WTP. The removal rate of manganese and turbidity were about 38% and 84%, respectively without pH control of raw water. However, when pH of raw water was controlled to average 7.9 with NaOH solution, the removal rate of manganese and turbidity increased to 95.0% and 95.5%, respectively and the water quality of filtrate satisfied the water quality standard. Manganese content in sand was over 0.3mg/g which is Japan Water Association Guideline. The content in upper filter was 5~10 times more than that of middle and lower during an early operation but the content in middle and lower filter was increased more and more with increase of operation time. This result means that the oxidized manganese was adsorbed well in sand. Rapid manganese sand filter was backwashed periodically. The water quality of backwash wastewater was improved by sedimentation. Thus, turbidity and manganese concentration decreased from 29.4NTU to 3.09NTU and from 1.7mg/L to 0.26mg/L, respectively for one day. In Jar test of backwash wastewater with PAC(Poly-aluminum chloride), optimum dosage was 30mg/L. Because the turbidity of filtrate was high as 0.76NTU for early 5 minute after backwash, filter-to-waste should be used after backwash to prevent poor quality water.

Distribution of Acanthamoeba spp. in Raw Water and Water Treatment Process (상수원수 및 정수처리공정별 가시아메바 분포특성에 관한 연구)

  • Jung, Eun-Young;Jung, Mi-Eun;Park, Hong-Gi;Jung, Jong-Moon;Rho, Jae-Sun;Ryu, Pyung-Jong
    • Journal of Environmental Science International
    • /
    • v.17 no.10
    • /
    • pp.1121-1127
    • /
    • 2008
  • The free-living amoeba and Acanthamoeba sp. are widely distributed in fresh water, soil, air and dust in the world. We studied distribution of amoeba from low Nakdong River(Mulgum and Maeri) and removal efficiency in water treatment process of Busan metropolitan city. During this investigation, water quality showed pH $7.4{\sim}9.6({\pm}1.1)$, water temperature $2.0{\sim}29.0({\pm}17)^{\circ}C$, turbidity $4.8{\sim}27.4({\pm}11.0)$ NTU, chlorophyll-a $10.3{\sim}109.0({\pm}44.3)\;mg/m^{3}$, BOD $1.7\sim4.9({\pm}2.6)$ mg/L, COD $3.1\sim-6.9({\pm}5.0)$ mg/L and total coliform $17\sim920({\pm}200.5)$ MPN/100 mL. The free-living amoeba were detected highly than Acanthamoeba sp., 11 out of 22 in raw water samples were positive (50%) for Acanthamoeba sp. from February 2005 to December 2005. The seasonal characteristics of tree-living amoeba and Acanthamoeba sp. in raw water were mainly distributed through the spring to the early fall. When tree-living amoeba and Acanthamoeba sp. were passed through the water treatment of pilot-plant, approximately 80% was sure to be removed through pre-ozonation, sedimentation, send filtration. 100% was removed after post-ozonation process. All of the isolated amoebas from Nakdong River were Acanthamoeba sp. AC311 18S ribosomal RNA gene with 98% nucleotide sequence homology.

Towards a novel approach to improve drinking water quality at Dhaka, Bangladesh

  • Serajuddin, Md.;Chowdhury, Md. Aktarul Islam
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.136-142
    • /
    • 2018
  • The river water source of Saidabad Surface Water Treatment Plant at Dhaka, Bangladesh, is deteriorated too much to be treated by conventional treatment process due to excessive ammonia pollution. In order to improve the raw water quality before it enters into the main treatment chain, a pilot study was conducted for pre-treatment of the raw water. The objective is to investigate the rate of reduction of ammonia using the Meteor pilot, a biological pretreatment system, which is a laboratory scale Moving Bed Biofilm Reactor with a nominal volume of hundred liters, filled with 50 L of Meteor 660 media. The reduction of ammonia was quite significant on average 73%, while the reduction of COD was in a range from 20 to 60%. The Meteor pilot was able to treat and nitrify the raw water and produce an effluent that respects the guarantee of ammonia < $4.0mg\;NH_3-N/L$ when the raw water ammonia concentration was < $15mg\;NH_3-N/L$. The study identified operating parameters necessary to achieve the desired goal of adequate ammonia removal. The study results would benefit a range of systems across the country by providing guidance on the design and operation of a biological pre-treatment system for ammonia removal.

Corrosivity Characteristics of Raw Water in Korea (국내 상수원수의 부식성 특성)

  • Kim, Jin-Keun;Kim, Jae-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.839-846
    • /
    • 2011
  • To investigate corrosivity characteristics of raw water in Korea, Langelier index (LI) of 30 multi-regional water treatment plants (WTPs) were evaluated. Annual average values of LI at 30 WTPs were all negative, which means raw water in Korea is very corrosive. LI results for 4 major rivers showed that raw water from Han and Nakdong had relatively high values compared to those of Sumjin and Keum. On the other hand, LI values of raw water from the tributaries of four major rivers were relatively low presumably due to geological characteristics, and in some cases the values were less than -4.0 which means increase of LI is urgently needed to minimize red water problem. Based on the correlation results among LI and water quality parameters, pH, water temperature, calcium concentration were confirmed as major components for LI. Therefore, pH and calcium concentration control is an effective method for the improvement of LI in water treatment processes.

Automatic Determination of Coagulant Dosing Rate Using Fuzzy Neural Network (Fuzzy Neural Network에 응집제 투입률의 자동결정)

  • Chung, Woo-Seop;Oh, Sueg-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.1
    • /
    • pp.101-107
    • /
    • 1997
  • Recently, as the raw water quality becomes to be polluted and the seasonal and local variation of water quality becomes to be severe, an exact control of coagulant dosing have been required in the water treat- ment plant. The amounts of coagulant is related to the raw water quality such as turbidity, alkalinity, water temperature, pH and edectrical conductivity. However the process of chemical reaction has not been clarified so far, so the dosing rate has been decided by jar-test, which is taken one or two hours. For the sake of this coagulant dosing control, fuzzy neural network to fuse fuzzy logic and neural network was proposed, and the scheme was applied to automatic determination of coagulant dosing rate. This controller can automatically identify the if-then rules and tune the membership functions by utilizing expert's cintrol data. It is shown that determination of coagulant dosing rate according to real time sensing of water quality is very effect.

  • PDF

Evaluation of Corrosion Index by Water Quality Parameters in Korea (국내 수질에 적합한 부식성지수 선정 연구)

  • Ahn, Kyunghee;Yu, Soonju;Park, Sujeong;Kwon, Ohsang
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.615-623
    • /
    • 2012
  • In this study, we evaluate the corrosion indexes (CI) such as Langelier Index (LI), Larson ratio (LR), Ryznar saturation index (RSI), Aggressiveness index (AI) of water quality for raw water, treated water and water in distribution reservoir at major eight drinking water treatment plants (DWTPs) in Korea. By analyzing secondary contamination of tap water, the variation of secondary contaminants was investigated with regard to pipe materials, aging and corrosion index (CI). In addition, we suggested an appropriate CI applicable water quality and the management plan for CI monitoriing. All CI showed corrosive water quality, and they did not change significantly in the distribution network. However, Copper (Cu), iron (Fe) and zinc (Zn) concentrations as secondary contaminants increased through the distribution network. Among CI, LI was most sensitive to changes in raw water quality and drinking water treatment. Also, it has high correlations with other indexes such as RSI, AI. Therefore, LI is considered as an appropriate CI to the domestic water quality. Based on these result, we propose LI as a drinking water quality standard to control the pipe corrosion from DWTPs.

Effects of the Membrane Materials on the Filtration Characteristic in the Membrane Separation-activated Sludge Process (막 재질에 따른 막분리활성오니법의 여과 특성)

  • Kim, Hyung-Soo;Cho, Sang-Il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.2
    • /
    • pp.42-49
    • /
    • 1998
  • By checking the variations of the raw water quality and MLSS, the effects of the membrane materials on permeable flux and quality of the treated water were investigated in this study. Due to the stability for high variations of MLSS, tubular type membranes were selected. Polysulfone group membranes and polyamide group membranes were tested. The crossflow operation mode was adapted, because membrane fouling problems could be easily controlled by adjusting the linear velocity. Due to the high concentration of the raw water, polyamide group membranes were originally expected to achieve two times higher permeable fluxes. However, difference was only approximately $20l/m^2{\cdot}h$ at $3kgf/cm^2$. It might be resulted from the high concentration of organic materials in the effluent of the RBC process. For the quality of the treated water, polyamide group membranes were slightly less effective. It might be resulted from the fact that polysulfone group membranes had more adsorptive capacities for the organic materials. The effects of temperature on the permeable flux were found to be significant. Despite of the irregular injection of raw water, the quality of the treated water was kept stable.

  • PDF

Development of Analytical Method and Monitoring of Organophosphorus Pesticides in the Raw Water and Clean Water by Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS를 이용한 유기인계 농약류의 최적 분석법 정립과 원·정수에서의 모니터링)

  • Kim, Gyung-A;Song, Mi-Jeong;Yeom, Hoon-Sik;Son, Hee-Jong;Lee, Sang-Won;Choi, Jin-Tack
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1569-1582
    • /
    • 2015
  • The analytical method for 16 organophosphorus pesticides was developed in this study. The 16 organophosphorus pesticides were analyzed by liquid chromatography-tandem mass spectrometry (LC/MS/MS) using on-line solid phase extraction (on-line SPE) with PLRP- S cartridge. Analysis of all analytes in the MS/MS was processed in the electrospray ioni-zation (ESI) positive mode. They are Azinphos ethyl, Chlorfenvinphos, Ethion, Famphur, Phosmet, Phosphamidon, Terbufos, Aspon, Chlorpyrifos-methyl, Crotoxyphos, Dichlofenthi-on, Dicrotophos, Fonofos, Thionazin, Dimethoate and Iprobenfos. Limits of detection (LODs) and Limits of quantification(LOQs) were obtained as 0.8~2.0 ng/L and 2.6~6.4 ng/L, respectively. All compounds were not detected at the 8 sampling points of the raw water and clean water.

Estimation on the Design Capacities of Residuals Treatment Facilities by the Quantity of Dewatered Sludge Generated from Water Treatment Plants (정수장에서 발생된 탈수슬러지의 량에 의한 배출수처리시설용량에 대한 평가)

  • Moon, Yong-Taik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.715-723
    • /
    • 2004
  • The quantity of residuals generated from water treatment plants depends upon the raw water quality, dosage of chemicals used, performance of the treatment process, method of sludge removal, efficiency of sedimentation, and backwashing frequency. Sludge production by the physical separation of SS occurs under quiescent conditions in the primary clarifier, where suspended solids are allowed to settle and to consolidate on the clarifier bottom. Raw primary sludge results when the settled solids are hydraulically removed from the tank. The relative solid and liquid fractions of a slurry are most commonly described by the solids concentration, expressed as mg/L or percent solids. The purpose of the present investigation is to estimate a suitability on the design capacities of residuals treatment facilities by the quantity of dewatered sludge generated from water treatment plants.

Effects of Recycled Washwater on Pollutant Removal and Particle Characteristics during Coagulation (회수수가 응집공정의 오염물질 제거 및 입자특성에 미치는 영향)

  • 문병현;김승현;박미선;이향인;이강춘
    • Journal of Environmental Science International
    • /
    • v.11 no.9
    • /
    • pp.955-960
    • /
    • 2002
  • The recycled washwater, which has different water quality and is produced about 5 to 20% of the total water volume treated, affects the unit operation of water treatment, especially coagulation process. However, the effects of recycled washwater on unit operation of water treatment have not been fully investigated. In this study, effects of recycled washwater on coagulation process were investigated to find the optimum coagulation condition by analyzing turbidity, $UV_{254}$, TOC removal efficiencies. In addition, effects of recycled washwater on residual Al after coagulation were studied by analyzing soluble and particulate Al. The size distribution and fractal dimension of coagulated also analyzed. The recycled washwater was lower pH than the raw water. And the recycled washwater had higher $UV_{254}$, TOC and residual Al concentration than the raw water. Residual Al concentration of recycled washwater was about 50 times higher than that of raw water. Optimum coagulant dosages on the blending recycled washwater and the raw water for turbidity, $UV_{254}$ and Al removal were lower than that on the raw water. However, TOC removal increased by increasing coagulant dosage. The size and fractal dimension of coagulated particle produced in the blending recycled washwater were larger, which imply faster settling velocity, than those produced in the raw water only.