A Three-phase Hybrid Power Flow Algorithm for Meshed Distribution System with Transformer Branches and PV Nodes

  • Li, Hongwei;Wu, Huabing;Jiang, Biyu;Zhang, Anan;Fang, Wei
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.65-75
    • /
    • 2016
  • Aiming at analyzing the power flow of the distribution systems with distribution transformer (DT) branches and PV nodes, a hybrid three-phase power flow methodology is presented in this paper. The incidence formulas among node voltages, loop currents and node current injections have been developed based on node-branch incidence matrix of the distribution network. The method can solve the power flow directly and has higher efficiency. Moreover, the paper provides a modified method to model DT branches by considering winding connections, phase shifting and off-nominal tap ratio, and then DT branches could be seen like one transmission line with the proposed power flow method. To deal with the PV nodes, an improved approach to calculate reactive power increment at each PV node was deduced based on the assumption that the positive-sequence voltage magnitude of PV node is fixed at a given value. Then during calculating the power flow at each iteration, it only needs to update current injection at each PV node with the proposed algorithm. The process is very simple and clear. The results of IEEE 4 nodes and the modified IEEE 34 nodes test feeders verified the correctness and efficiency of the proposed hybrid power flow algorithm.

Electrical Properties of PNN-PMN-PZT ceramics for Rosen Type Transformer Applications (Rosen type 변압기 응용을 위한 PNN-PMN-PZT 세라믹스의 전기적 특성)

  • Joo, H.K.;Kim, I.S.;Song, J.S.;Kim, M.S.;Jeong, S.J.;Lee, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1244-1245
    • /
    • 2008
  • Recently, piezoelectric transformer is applied to wide fields. Multi layer piezoelectric transformer has the advantage of high step up ratio, electromechanical coupling coefficient(Kp) and mechanical quality factor(Qm), but is indicated of peeling-phenomenon of electrode, rising sintering temperature made price of costly electrode. So in this study, it discuss on method for fabrication of rosen type piezoelectric transformers. For the fabrication as rosen type piezoelectric transformers, synthesized the powder using 0.01Pb$(ni_{1/3}Nb_{2/3})O_3$ - 0.08Pb$(Mn_{1/3}Nb_{2/3})O_3$ - 0.91Pb$(Zr_{0506}Ti_{0496})O_3$ (abbreviated as PNN-PMN-PZT) ceramics. The density, microstructure, dielectric and piezoelectric properties as a function of sintering temperature were investigated. The results indicated that the optimized properties of ceramics were obtained at sintering temperature of 1200$^{\circ}C$, showed the value of $d_{33}$=273pC/N, $K_p$=0.60 $Q_m$=1585, ${\varepsilon}_r$=1454, density=7.917$g/cm^3$ and $tan{\delta}$=0.0064.

  • PDF

A Design of Power Amplifier with Broadband and High Linearity for 4G Application in 0.11 μm CMOS Process (0.11 μm CMOS 공정을 이용한 4세대 이동통신용 광대역 고 선형 전력증폭기의 설계 및 구현)

  • Kim, Ki-Hyun;Ko, Jae-Yong;Nam, Sang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.1
    • /
    • pp.50-59
    • /
    • 2016
  • This work shows that the design and test results of a power amplifier(PA) with broadband and high linearity for 4G applications in $0.11{\mu}m$ CMOS process. A 1:2-transformer is designed for load impedance matching of PA and a inter-stage matching is implemented for a linearity. A designed PA achieves more than 27.3 dBm of linear output power and 26.1 % of power-added efficiency(PAE) under an adjacent channel leakage ratio(ACLR) of -30 dBc for a LTE 16-QAM 10 MHz signal with a carrier frequency range of 1.8 to 2.3 GHz.

Compact 1×2 and 2×2 Dual Polarized Series-Fed Antenna Array for X-Band Airborne Synthetic Aperture Radar Applications

  • Kothapudi, Venkata Kishore;Kumar, Vijay
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.2
    • /
    • pp.117-128
    • /
    • 2018
  • In this paper, compact linear dual polarized series-fed $1{\times}2$ linear and $2{\times}2$ planar arrays antennas for airborne SAR applications are proposed. The proposed antenna design consists of a square radiating patch that is placed on top of the substrate, a quarter wave transformer and $50-{\Omega}$ matched transformer. Matching between a radiating patch and the $50-{\Omega}$ microstrip line is accomplished through a direct coupled-feed technique with the help of an impedance inverter (${\lambda}/4$ impedance transformer) placed at both horizontal and vertical planes, in the case of the $2{\times}2$ planar array. The overall size for the prototype-1 and prototype-2 fabricated antennas are $1.9305{\times}0.9652{\times}0.05106{{\lambda}_0}^3$ and $1.9305{\times}1.9305{\times}0.05106{{\lambda}_0}^3$, respectively. The fabricated structure has been tested, and the experimental results are similar to the simulated ones. The CST MWS simulated and vector network analyzer measured reflection coefficient ($S_{11}$) results were compared, and they indicate that the proposed antenna prototype-1 yields the impedance bandwidth >140 MHz (9.56-9.72 GHz) defined by $S_{11}$<-10 dB with 1.43%, and $S_{21}$<-25 dB in the case of prototype-2 (9.58-9.74 GHz, $S_{11}$< -10 dB) >140 MHz for all the individual ports. The surface currents and the E- and H-field distributions were studied for a better understanding of the polarization mechanism. The measured results of the proposed dual polarized antenna were in accordance with the simulated analysis and showed good performance of the S-parameters and radiation patterns (co-pol and cross-pol), gain, efficiency, front-to-back ratio, half-power beam width) at the resonant frequency. With these features and its compact size, the proposed antenna will be suitable for X-band airborne synthetic aperture radar applications.

Design of Isolation-Type Matching Network for Underwater Acoustic Piezoelectric Transducer Using Chebyshev Filter Function (체비셰프 필터함수를 이용한 수중 음향 압전 트랜스듀서의 절연형 정합회로 설계)

  • Lee, Jeong-Min;Lee, Byung-Hwa;Baek, Kwang-Ryul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.491-498
    • /
    • 2009
  • This paper presents the design method of an impedance matching network using an isolation transformer and the Chebyshev filter function for the high efficiency and the flat power driving of an underwater acoustic piezoelectric transducer. The proposed impedance matching network is designed for minimizing the reactance component of transducer and having the flat power response in the wide frequency range. We design a low pass filter with ladder-type circuit using the Chebyshev function as standard prototype filter function. In addition, we design the impedance matching network which is suitable for the equivalent circuit of transducer and the turn ratio of transformer through the bandpass frequency transformation. The proposed method is applied to the simulated dummy load of the tonpilz-type transducer operating in the middle frequency range. The simulation results are compared with the measured characteristics and the validity of the proposed method is verified.

Analysis of the response of a distance relay considering the errors of CT and CCVT (CT와 CCVT의 오차를 고려한 거리 계전기의 응동 분석)

  • Kang, Yong-Cheol;Zhang, Tai-Ying;Choi, Jae-Sun;Kang, Hae-Gweon;Kim, Kwang-Moo;Jang, Sung-Il;Kim, Yong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.12-15
    • /
    • 2008
  • A distance relay has been widely used for transmission line protection. The distance relay detects a fault based on the calculated impedance i.e. the ratio of the voltage to the current measured from a current transformer (CT) and a coupling capacitor voltage transformer (CCVT), respectively. When a fault occurs and a CT saturates due to the magnitude of fault current, dc component, primary time constant, and the remanent flux of the iron core, the secondary current of a CT is distorted On the other hand, non-fundamental components generated during a fault can increase the error of a CCVT, particularly when a fault distance is short. The distortion of the current and voltage can cause mal-operation or the operating time delay of a distance relay. This paper describes the response of a distance relay considering the errors of a CT and a CCVT. The results indicate that the severe distortion of a CT and a CCVT have noticeable effect to a distance relay.

  • PDF

Analysis of Transient Characteristics of a SFCL Applied Into Third-winding Transformer in a Single Line-to-ground Fault (1선 지락 사고 시 3 권선 변압기에 적용된 초전도 한류기의 동작 특성 분석)

  • Choi, Hye-Won;Choi, Hyo-Sang;Jung, Byung-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1033-1037
    • /
    • 2013
  • Coercion transformer is commonly used in the electrical grid which in three phase of distribution system. The accident of the electrical grid is divided into a single, a double, a third line-to-ground faults and a double, a third line-to-line faults. A single line-to-ground fault accounts for nearly 75[%] among them. In this research, when a Superconducting Fault Current Limiters (SFCL) was applied to the three phase power system, operation in a single line-to-ground fault and limiting characteristics of fault current according to turns ratio of third winding were analyzed. When a single line-to-ground fault happened, secondary winding's circuit was open. Then third winding's circuit with a SFCL was closed. So fault current was limited by diverted circuit. At this time, we could find out that size of the limited fault current could be changed according to third winding rate. We confirmed that limiting operation of the fault current was carried out within one-period. These results will be utilized in adjusting the size of the SFCL.

The New Criteria of Dissolved Gas Analysis for Oil-Filled Transformers Using a Cumulative Distribution Function

  • Cho, Sung-Min;Kim, Jae-Chul;Kweon, Dong-Jin;Koo, Kyo-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.9
    • /
    • pp.87-94
    • /
    • 2007
  • This paper presents new criteria for DGA(Dissolved Gases Analysis) using CDF(Cumulative Distribution Function) obtained from the data from the diagnosis of transformers operated in KEPCO over a period of 16 years. Because of differences in operating environments, construction type, oil volume, and other factors, the interpretative criteria of DGA at KEPCO differs from other standards such as IEC-60599, or Rogers and Doernenburg. To suggest the most appropriate criteria, the DGA data from transformers under normal conditions as well as from developing fault transformers were collected. Using these data, this study suggests the limitative gas level of transformers under normal operating conditions and verifies the suitability of the criteria. Because the application of this new criterion to transformers at KEPCO increases the detectable ratio of incipient faults and reduces unnecessary follow-up sampling and analysis, the new criteria yields a more reliable prediction of transformer condition.

Fuzzy Logic Application in Fault Diagnosis of Transformers Using Dissolved Gases

  • Hooshmand, Rahmat-Allah;Banejad, Mahdi
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.293-299
    • /
    • 2008
  • One of the problems with the fault diagnosis of transformers based on dissolved gas is the inability to match the result of the different standards of fault diagnosis with real world standards. In this paper, the results of the different standards are analyzed using fuzzy logic and then compared with the empirical test. The proposed method is based on the standards and guidelines of the International Electrotechnical Commission (IEC), the Central Electric Generating Board (CEGB), and the American Society for Testing and Material (ASTM) and its main task is to assist the conventional gas ratio method. The comparison between the suggested method and existing methods indicates the capability of the suggested method in the on-line fault diagnosis of transformers. In addition, in some cases the existing standards are not able to diagnose the fault. For theses instances, the presented method has the potential of diagnosing the fault. In this paper, the information of three real transformers is used to show the capability of the suggested method in diagnosing the fault. The results validate the capability of the presented method in fault diagnosis of the transformer.

Compensation of an Air-Gapped Current Transformer in the steady state (정상상태에서 공극 변류기의 보상)

  • Kang, Yong-Cheol;Park, Ji-Youn;So, Soon-Hong;Jang, Sung-Il;Kim, Yong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.15-17
    • /
    • 2006
  • This paper proposes a compensation method for an air gapped current transformer (CT) in the steady state. An air gapped CT is used in order to reduce a remanent flux in the case of auto-reclosure. It causes larger ratio and angle errors than the closed core CT because the magnetizing inductance of an air-gapped CT is even smaller than the closed-core CT. The core flux is calculated and used to estimate the exciting current in accordance with the hysteresis curve of the air-gapped CT The correct current is obtained by adding the estimated exciting current to the measured secondary current. The performance of the method was investigated for the air gapped CTs with a gap of 0.083mm and 0.249mm for the 120%, 100% and 20% of the rated current. Various test results indicate that the proposed compensation algorithm can improves the accuracy significantly.

  • PDF