• Title/Summary/Keyword: ratio control

Search Result 9,919, Processing Time 0.038 seconds

Determination of the Optimal Control-Response Ratio for Data Searching Through a Touchpad Placed on the Steering Wheel (스티어링 휠의 터치패드를 이용한 정보 목록 검색 시 조작 : 반응 비율에 관한 연구)

  • Kim, Jong-Seok;Jung, Eui-S.;Park, Sung-Joon;Jeong, Seong-Wook
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2009
  • As the number of personal computers installed in vehicles increases, a touchpad often used in a labtop computer can be used for the control of an in-vehicle information system (IVIS). Using a touchpad to control the system allows the user to select among large amount of information with a single touch of dragging. For safety and convenience of a driver, the touchpad could be placed on a steering wheel. This research is designed to calculate the most efficient Control-Response Ratio (C/R ratio) for the menu interaction of a touchpad on a steering wheel. Since the menu pointer's rate of movement and proper C/R ratio is determined by the amount of selected information, the amount of displayed information and the movement of a menu pointer was chosen to be independent variables. The dependent variables are a user's preference and task completion time. Two factor full factorial within subject design was used 16 subjects. The investigation revealed that the amount of selected information increased with increasing C/R ratio. The movement of the pointer became slower as the amount of information increased. The best C/R ratio was calculated for each amount of information and preference regression of the user's preference was drawn accordingly. Through this research, the automobile interior designer can benefit from the guidelines suggested for the touchpad control.

Vibration control in high-rise buildings with tuned liquid dampers - Numerical simulation and engineering applications

  • Zijie Zhou;Zhuangning Xie;Lele Zhang
    • Wind and Structures
    • /
    • v.36 no.2
    • /
    • pp.91-103
    • /
    • 2023
  • Tuned liquid dampers (TLDs) are increasingly being used as efficient dynamic vibration absorbers to mitigate wind-induced vibration in super high-rise buildings. However, the damping characteristics of screens and the control effectiveness of actual structures must be investigated to improve the reliability of TLDs in engineering applications. In this study, a numerical TLD model is developed using computational fluid dynamics (CFD) and a simulation method for achieving the coupled vibration of the structure and TLD is proposed. The numerical results are verified using shaking table tests, and the effects of the solidity ratio and screen position on the TLD damping ratios are investigated. The TLD control effectiveness is obtained by simulating the wind-induced vibration response of a full-scale structure-TLD system to determine the optimal screen solidity ratio. The effects of the structural frequency, damping ratio, and wind load amplitude on the TLD performance are further analyzed. The TLD damping ratio increases nonlinearly with the solidity ratio, and it increases with the screens towards the tank center and then decreases slightly owing to the hydrodynamic interaction between screens. Full-scale coupled simulations demonstrated that the optimal TLD control effectiveness was achieved when the solidity ratio was 0.46. In addition, structural frequency shifts can significantly weaken the TLD performance. The control effectiveness decreases with an increase in the structural damping ratio, and is insensitive to the wind load amplitude within a certain range, implying that the TLD has a stable damping performance over a range of wind speed variations.

Robust Nonlinear Control of Air-to-Fuel Ratio in Spark Ignition Engines

  • Myoungho Sunwoo;Paljoo Yoon;Park, Seungbum;Lee, Wootaik
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.699-708
    • /
    • 2001
  • This paper presents a new approach to the AFR (Air-to-Fuel Ratio) control problem, which is based on the wide-band oxygen sensor output. The dedicated nonlinear controller is based on the feedback lineaization technique. It is well known that the feedback linearizing control technique requires an exact model of the plant for the cancellation of plant nonlinearities. A sliding mode control scheme is applied which can effectively compensate the modeling uncertainties. The measurement time delay of an oxygen sensor limits the gain of the feedback controller. Hence, time delay compensation procedure is necessary for the improvement of control performance. The Smith predictor is adopted to compensate the effects of time delay. The simulation and experimental results show that the proposed controllers can effectively reduce the transient peaks of AFR in spite of fast tip-in and tip-out maneuvers of the throttle.

  • PDF

The Study on Earlier Evaluation of Concrete Strength Using Electric Resistance Method (전기 저항법을 이용한 콘크리트 조기 강도 판정에 관한 연구)

  • 김화중;이도현;윤상천;박정민;최신호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.130-135
    • /
    • 1995
  • We can consider that the study on early evaluation of strength of concrete is useful to raise safety of building and utility of quality control of concrete is useful to raise safety of building and utility of quality control of concrete. In this paper, was proposed to method early to predict strength of concrete with key parameters, such as Water/Cement(W/C) ratio and Sand / Aggregate(S/A) ratio. Through a series of experiment, the obtained results are summarized as follow. $\circled1$ The ratio of resistance was decteased as the increase of W/C ratio. $\circled2$ The maximum value for the ratio of resistance and compressive strength was presented in the case of 40% S/A ratio. $\circled3$ The relationship. of the ratio of resistance and compressive strength on 28days according to the change of W/C and S/A ratio is to be: $F_{28}=-0.00104R^2 + 2.263R - 935.5$ (W/C Ratio) $F_{28} = 0.007R^2 - 10.693R - 4269.1$ (S/A Ratio)

  • PDF

Performance Analysis of ATM Switch Using Dynamic Priority Control Mechanisms (동적 우선순위 제어방식을 사용한 ATM 스위치의 성능분석)

  • 박원기
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.4
    • /
    • pp.855-869
    • /
    • 1997
  • In this paper, we proposed two kids of dynamic priority control mechanisms controlling the cell service ratio in order to improve the QOS(Quality of Service). We also analyse theoretically the characteristics of cell loss probability and mean cell delay time by applying the proposed priority control mechanisms to ATM switch with output buffer. The proposed priority control mechanisms have the same principles of storing cells into buffer but the different principles of serving cells from buffer. The one is the control mechanism controlling the cell service ratio according to the relative cell occupancy ratio of buffer, the other is the control mechanism controlling the cell service ratio according to both the relative cell occupancy ratio of buffer and the average arrival rate. The two service classes of our concern are the delay sensitive class and the loss sensitive class. The analytical results show that the proposed control mechanisms are able to improve the QOS, the characteristics of cell loss probability and mean cell delay time, by selecting properly the relative cell occupancy ratio of buffer and the average arrival rate. conventional DLB algorithm does not support synchronous cells, but the proposed algorithm gives higher priority to synchronous cells. To reduce synchronous cell loss rate, the synchronous cell detector is used in the proposed algorithm. Synchronous cell detector detects synchronous cells, and passes them cells to the 2nd Leaky-Bucket. So it is similar to give higher priority to synchronous cells. In this paper, the proposed algorithm used audio/video traffic modeled by On/Off and Two-state MMPP, and simulated by SLAM II package. As simulation results, the proposed algorithm gets lower synchronous cell loss rate than the conventional DLB algorithms. The improved DLB algorithm for multimedia synchronization can be extended to any other cells which require higher priority.

  • PDF

Duty Ratio-Displacement Model in PWM Control of Voice Coil Actuator (보이스 코일 액츄에이터의 PWM 제어에서 듀티비-변위 모델 연구)

  • Hwang, Jin-Dong;Kwak, Yong-Kil;Kim, Ju-Hyun;Kim, Sun-Ho;Ahn, Jung-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.2
    • /
    • pp.59-66
    • /
    • 2007
  • Voice coil actuator is used linear motion system that requires precision positioning control. In order to control precision positioning of voice coil actuator, relation model between duty ratio and moving displacement of voice coil actuator is needed. This paper present a duty ratio - displacement model in PWM control of voice coil actuator. Transfer function of voice coil actuator is obtained by combining voice coil motor's equation of motion with the equation of circuit and characteristic of voice coil motor. Consider to initial condition of velocity and current, transfer function is transformed mathematical model. The induced model can predict output displacement, velocity and current according to duty ratio and amplitude. The model is verified by experimental tests such as velocity and displacement response of voice coil motor. Simulated results have tracking errors of less than 10 percent of experimental results.

  • PDF

A Study on the Relationship between Recurrent Aphthous Ulcer and Oral Mucosal Keratinization (재발성 아프타성 궤양과 구강점막 각화도의 관계에 대한 연구)

  • Yu-Kyung Lee;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.449-459
    • /
    • 1995
  • To investigate the relationship between recurrent aphthous ulcer and oral mucosal keratinization, exfoliative cytology in buccal mucosa, lip mucosa, tongue mucosa were performed on 25 recurrent aphthous ulcer patients and 25 controls whose age ranged from 10 to 65. Keratinization cell ratio was then measured. The results were as follows : 1. Yellow cell ratio in the control group was more than that in the patient group in buccal mucosa, lip mucosa, tongue mucosa. Red cell ratio in the control group was more than that in the patient group in lip mucosa. Blue cell ratio in the patient group was more than that in control group in all regions( p(0.01) 2. In the comparison by sex, the patient group showed no significant difference in all site but, the control group showed different results according to the site; males were more than females in yellow cell, but less than females in red cell Females were more than males in yellow cell, but less than males in red cell. 3. In the comparison by age, patient group showed no significant difference in all site, but the control group showed significantly high yellow cell ratio in buccal and tongue mucosa over the age of 50. In conclusion, there was close relationship between recurrent aphthous ulcer and decreased oral mucosal keratinization. In other words, reduced oral mucosal keratinization must be recommended for prevention of recurrent aphthous ulcer.

  • PDF

Comparison of Dietary Intakes and Plasma Lipid Levels in Diabetes and Control Elderly (당뇨병 노인군과 대조군의 영양소 섭취실태 및 혈장지질 양상비교)

  • 이상은;김정희
    • Korean Journal of Community Nutrition
    • /
    • v.9 no.1
    • /
    • pp.98-112
    • /
    • 2004
  • This study was done to investigate and compare the nutritional status and plasma lipids in the diabetes and control elderly. Subjects were 105 persons (male 32, female 73) aged over 65 years and visited public health centers in Ulsan area. The subjects were divided into 2 groups, diabetes and control group. Athropometric measurement, dietary intakes, and plasma biochemical indices were examined. Body Mass Index (BMI), Percentage of Ideal Body Weight (PIBW) and Waist-Hip Ratio (WHR) of diabetes group were higher than those of control group. Overall eating behavior were worse in diabetes group than those of control group. There was no significant difference in smoking and exercise status among groups. The ratio of drinkers was significantly higher in control group. But the amount of alcohol consumed at once was higher in the diabetes group. There was no significant difference in most nutrient intakes between males and females. The intakes of fiber, natrium (Na), vitamin A, and $\beta$-carotene were significantly higher in diabetes group than control groups while that of potassium (K) was lower in diabetes group. Diabetes group had the higher levels in triglyceride, VLDL-cholesterol, Chol/HDL-cholesterol ratio, LDL/HDL-cholesterol ratio, while they had lower HDL-cholesterol level. Overall results might imply that the elderly with diabetes have to be more careful to their meals and health-related behaviors to increase the likelihood of a healthier life.

Automatic Control of Engine Speed and Transmission Ratio for Efficient Tractor Operations(I) -Control Systems for Engine Speed and Transmission Ratio- (트랙터의 기관속도(機關速度) 및 변속비(變速比)의 자동제어(自動制御)에 관(關)한 연구(硏究)(I) -기관속도(機關速度) 및 변속비(變速比) 제어(制御) 시스템-)

  • Kang, S.B.;Ryu, K.H.;Oh, K.K.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.4
    • /
    • pp.305-316
    • /
    • 1993
  • Fuel efficiency in tractor operations dep6nds on the selection of transmission gears and upon the engine being operated at or near maximum torque much of time. The objective of this study was to develop automatic control systems for tractor transmission ratio and governor setting so that the engine is operated at or near maximum torque as much of time as possible. An indoor test unit, which can be used to simulate tractor operation, was built in order to investigate the system design parameters and test the performance of the control system designed. The test-unit consists of engine, gear-type transmission, dynamometer, and control systems for transmission ratio and engine speed. Governor setting lever was controlled by a step motor, and the clutch and transmission levers were controlled by hydraulic cylinders and solenoid valves. The control systems showed good time responses which are assumed to be suitable for optimal tractor operation. The time required for shifting gears from clutch disengagement to engagement was about 1 second, which is almost the same as that for manual shift. And the settling time for engine speed control system was about 5 to 6 seconds.

  • PDF

A Fundamental Study of Air-Fuel Ratio Control on LPG Liquid Injection Engines (LPG 액체분사엔진의 공연비제어에 관한 기초 연구)

  • Sim, Han-Seop;Sunwoo, Myoungho;Song, Chang-Seop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.7
    • /
    • pp.80-87
    • /
    • 2002
  • Liquefied petroleum gas (LPG) is used in spark ignition (SI) engines. Fuel injection rate of an injector is affected by fuel temperature and pressure in LPG liquid injection systems for either a multi-point-injection (MPI) or a direct injection (DI) engine. Even fuel injection conditions are varied, the air-fuel ratio should be accurately controlled to reduce exhaust emissions. In this study, a correction factor fur the fuel injection rate of an injector is derived from density ratio and pressure difference ratio. A compensation method of injected fuel amount is proposed for a fuel injection control system. The experimental results for the LPG liquid injection system in a SI engine show that this system works well fur a full range of engine speed and load condition, and the air-fuel ratio is accurately controlled by the proposed correction factor.