• Title/Summary/Keyword: rapid measurements

Search Result 441, Processing Time 0.027 seconds

Effect of Native Oxide Layer on the Water Contact Angle to Determine the Surface Polarity of SiC Single Crystals (접촉각 측정방법을 이용한 SiC 단결정의 극성표면 판별에 있어 자연산화막의 영향)

  • Park, Jin Yong;Kim, Jung Gon;Kim, Dae Sung;Yoo, Woo Sik;Lee, Won Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.245-248
    • /
    • 2020
  • The wettability of silicon carbide (SiC) crystal, which has 6H-SiC and 4H-SiC regions prepared using the physical vapor transport (PVT) method, is quantitatively analyzed using dispensed deionized (DI) water droplets. Regardless of the polytypes in SiC, the average of five contact angle measurements showed a difference of about 6° between the Si-face and C-face. The contact angle on the Si-face (C-face) is measured after the removal of the native oxide using BOE (6:1), and revealed a significant decrease of the contact angle from 74.9° (68.4°) to 47.7° (49.3°) and from 75.8° (70.2°) to 51.6° (49.5°) for the 4H-SiC and 6H-SiC regions, respectively. The contact angle of the Si-face recovered over time during room temperature oxidation in air; in contrast, that of the C-face did not recover to the initial value. This study shows that the contact angle is very sensitive to SiC surface polarity, specific surface conditions, and process time. Contact angle measurements are expected to be a rapid way of determining the surface polarity and wettability of SiC crystals.

Study on the Development of Ubiquitous-Based Landslide with a Debris Flow Monitoring System (유비퀴터스 기반 토석류 산사태 모니터링 시스템 개발에 관한 연구)

  • Kim, Yong-Gyun;An, Dae-Young;Kang, Dea-Woo;Han, Byung-Won
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.511-522
    • /
    • 2008
  • Domestic slope related measuring system are mainly depending on manual and visual measurements and technical development for natural slopes is poor since the technology is developed focusing on artificial cut slopes. In addition, landslide with a debris flow is occurring frequently due to recent climate abnormally and heavy rains but early forecasts and prevention of disasters are in poor condition. Therefore, construction of ubiquitous sensor network (USN) capable of detecting dangers of landslide for rapid countermeasures is necessary. In this study, new measurements devices and measurement management techniques in compliance with domestic conditions are prepared by establishing ubiquitous based landslide monitoring system and standards of measurement management.

A Study on the Laminar Burning Velocity and Flame Structure with H2 Content in a Wide Range of Equivalence Ratio of Syngas(H2/CO)/Air Premixed Flames (넓은 당량비 구간에서 수소함유량에 따른 합성가스(H2/CO)/공기 예혼합화염의 연소속도 및 화염구조에 관한 연구)

  • Jeong, Byeong-Gyu;Lee, Kee-Man
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.1
    • /
    • pp.17-28
    • /
    • 2014
  • In this study, the laminar burning velocity of syngas fuel($H_2/CO$) and flame structure with various hydrogen contents were studied using both experimental measurements and detailed kinetic analysis. The laminar burning velocities were measured by the angle method of Bunsen flame configuration and the numerical calculations including chemical kinetic analysis were made using CHEMKIN Package with USC-Mech II. A wide range of syngas mixture compositions such as $H_2$ : CO = 10 : 90, 25 : 75, 50 : 50, 75:25 and equivalence ratios from lean condition of 0.5 to rich condition of 5.0 have been considered. The experimental results of burning velocity were in good agreement with previous other research data and numerical simulation. Also, it was shown that the experimental measurements of laminar burning velocity linearly increased with the increment of $H_2$ content although the burning velocity of hydrogen is faster than the carbon monoxide above 10 times. This phenomenon is attributed to the rapid production of hydrogen related radicals such as H radical at the early stage of combustion, which is confirmed the linear increase of radical concentrations on kinetic analysis. Particular concerns in this study are the characteristics of burning velocity and flame structure different from lean condition for rich condition. The decrease of OH radicals and double peaks are observed with $H_2$ content in rich condition once $H_2$ fraction exceeds over threshold.

Early overcounting in otoliths: a case study of age and growth for gindai (Pristipomoides zonatus) using bomb 14C dating

  • Andrews, Allen H;Scofield, Taylor R.
    • Fisheries and Aquatic Sciences
    • /
    • v.24 no.1
    • /
    • pp.53-62
    • /
    • 2021
  • Gindai (Pristipomoides zonatus) is one of six snappers in a management complex called the Deep 7 of the Hawaiian Islands. Little is known about its life history and a preliminary analysis of otolith thin sections indicated the species may exhibit moderate growth with a lifespan approaching 40 years. Preliminary age estimates from the previous study were reinvestigated using the same otolith sections in an attempt to validate those ages with bomb radiocarbon (14C) dating. From the misalignment of birth years for the otolith 14C measurements with regional references - the post-peak bomb 14C decline period - it was concluded that previous ages were inflated from overcounting of the earliest growth zone structure in otolith sections. The oldest gindai was re-aged to 26 years once the age reading was adjusted for early overcounting, 13 years younger than the original estimate of 39 years for this fish. In general, the earliest otolith growth of gindai was massive and complicated by numerous subannual checks. The approach of lumping the early growth structures was supported by the alignment of 14C measurements from otolith core material (first year of growth). The result was greater consistency of calculated birthdates with the 14C decline reference, along with minor offsets that may indicate age estimation was imprecise by a few years for some individuals. The revised von Bertalanffy growth function applied to the validated age-at-length estimates revealed more rapid growth (k = 0.378 cf. 0.113) and a lifespan of approximately 30 years. The findings presented here are a case study of how the bomb 14C decline period can be used as a tool in the refinement of age reading protocols.

A study on coil temperature bariation in 75% hydrogen batch annealing furnace (75% 수소 BATCH 소둔시에서의 코일 온도변화에 관한 연구)

  • Jeon, Eon-Chan;Kim, Soon-Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.2
    • /
    • pp.173-181
    • /
    • 1994
  • A Cold spot temperature control system for the batch annealing furnace has been estabilished in order to reduce energy consumption to improve productivity and stabilize the propertics of products. Therefore we confirmed a relation between annealing cycle time and atmospheric gas, variation of coil cold spot temperature with time during heating and actual temperature measurements at mid-width of each coil during heating and actual temperature measurements at mid-width of each coil during soaking. The results of the tempaeature variation effect on the batch annealing are as follows. 1) Heating time is reduced to one half with increasing atmospheric gas flow rate and changing of atmospheric gas component from HNx to Ax gas, and annealing cycle time is reduced to 2.7 times. 2) In case of short time healing, the slowest heating part is the center of B coil, in case of long time heating, the low temperature point moves from the center of coil to inside coil. And the temperature in this part is higher than other parts when cooling. When finished heating, the cold spot is located 1/3 of coil inside in case of HNx atmospheric gas. But center of coil in case of Ax atmospheric gas. 3) The outside of top coil is the highest temperature point when heating, which becomes the lowest temperature point when cooling. So, this point becomes high temperature zone at heating and low temperature zone at cooling, It has relation according to atmospheric gas component and flow rate. 4) Soaking time at batch annealing cycle determination is made a decision by the input coil width, and soaking time for quality homogenization of 1214mm width coil must be 2.5 hours longer than that of 914mm width coil for the same ciol weight. 5) Annealing cycle time with Ax atmospheric gas is extended 1 hour in of slow cooling during 5 hours in order to avoid rapid cooling.

  • PDF

Value of Nutritional Screening Tools Versus Anthropometric Measurements in Evaluating Nutritional Status of Children in a Low/Middle-Income Country

  • Shaimaa Sayed;Mortada H. F. El-Shabrawi ;Eman Abdelmonaem ;Nehal El Koofy;Sara Tarek
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.26 no.4
    • /
    • pp.213-223
    • /
    • 2023
  • Purpose: Pediatric patients in low-income countries are at a high risk of malnutrition. Numerous screening tools have been developed to detect the risk of malnutrition, including the Subjective Global Nutritional Assessment (SGNA), Pediatric Yorkhill Malnutrition Score (PYMS), Screening Tool for the Assessment of Malnutrition in Pediatrics (STAMP), and Screening Tool for Risk of Nutritional Status and Growth (STRONGkids). However, anthropometry remains the main tool for assessing malnutrition. We aimed to identify the value of four nutritional screening tools versus anthropometry for evaluating the nutritional status of children. Methods: We conducted a cross-sectional study of 1,000 children aged 1-12 years who visited the outpatient clinic of Cairo University Pediatric Hospital. Each participant was evaluated using anthropometric measurements (weight, length/height, and weight for length/height) as well as the PYMS, STAMP, STRONGkids, and SGNA screening tools. The sensitivities and specificities of these four tools were assessed using anthropometry as the gold standard. Results: Of the patients, 1.7% were underweight, 10.2% were wasted, and 35% were stunted. STRONGkids demonstrated the highest sensitivity (79.4%) and a high specificity (80.2%) for detecting malnutrition compared with weight for height, followed by STAMP, which demonstrated lower sensitivity (73.5%) but higher specificity (81.4%). PYMS demonstrated the lowest sensitivity (66.7%) and the highest specificity (93.5%), whereas SAGA demonstrated higher sensitivity (77.5%) and lower specificity (85.4%) than PYMS. Conclusion: The use of nutritional screening tools to evaluate the nutritional status of children is valuable and recommended as a simple and rapid method for identifying the risk of malnutrition in pediatric patients.

Effect of Annealing Temperature on the Luminescence Properties of Digital-Alloy InGaAlAs Multiple Quantum Wells (디지털 합금 InGaAlAs 다중 양자 우물의 열처리 온도에 따른 발광 특성)

  • Cho, Il Wook;Byun, Hye Ryoung;Ryu, Mee-Yi;Song, Jin Dong
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.6
    • /
    • pp.321-326
    • /
    • 2013
  • The effect of rapid thermal annealing (RTA) on the optical properties of digital-alloy InGaAlAs multiple quantum well (MQW) structures have been investigated by using photoluminescence (PL) and time-resolved PL measurements as a function of RTA temperature. The MQW samples were annealed from $700^{\circ}C$ to $850^{\circ}C$ for 30 s in a nitrogen atmosphere. The MQW sample annealed at $750^{\circ}C$ exhibited the strongest PL intensity and the narrowest FWHM (Full width at half maximum), indicating the reduced nonradiative recombination centers and the improved interfaces between the wells and barriers. The MQW samples annealed at $800^{\circ}C$ and $850^{\circ}C$ showed the decreased PL intensities and blueshifted PL peaks compared to $750^{\circ}C$-annealed sample. The blueshift of PL peak with increasing RTA temperatures are ascribed to the increase of aluminum due to intermixing of gallium (Ga) and aluminum (Al) in the interfaces of InGaAs/InAlAs short-period superlattices. The decrease of PL intensity after annealing at $800^{\circ}C$ and $850^{\circ}C$ are attributed to the interface roughening and lateral composition modulation caused by the interdiffusion of Ga and Al and indium segregation, respectively. With increasing RTA temperature the PL decay becomes slower, indicating the decrease of nonradiative defect centers. The optical properties of digital-alloy InGaAlAs MQW structures can be improved significantly with optimum RTA conditions.

Interior surface treatment guidelines for classrooms according to the acoustical performance criteria (학교 교실의 음환경 기준에 따른 실내마감 방안)

  • Ryu, Da-Jung;Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.2
    • /
    • pp.92-101
    • /
    • 2016
  • There are many results in which acoustical conditions of a classroom play an important role for studying effects and academic achievement of students. However, there are very few guidelines or design proposals which could make appropriate acoustic environment when classrooms are built or renovated. The present study suggests various design proposals satisfying acoustic standards of classrooms based on theoretical calculation and acoustic field experiments. At first, minimum area of sound absorption was calculated which is required to satisfy the acoustic standard for domestic middle and high schools. Also, room acoustic measurements were carried out in order to investigate the acoustic performance of an existing classroom by changing interior finishing materials on ceiling and rear walls. As a result, it was revealed that reverberation time standard below 0.8 s can be acquired even if there is no sound absorption on ceiling which is a general practice executed in Korea. Specially, it was found that if partial area of ceiling would be treated as reflective with the ratio of sound absorption and reflection as 2:1, almost similar acoustic parameters of $C_{50}$, $D_{50}$, RASTI (Rapid Speech Transmission Index) and higher sound levels could be acquired in comparison with the case of entire sound absorption on ceiling.

Manikin Model Study on Reproducibility and Accuracy of Maxillofacial Measurements Determined by Stereocamera: Comparative Study of Direct Anthropometry, Digitizer and Stereophotogrammetery (스테레오 카메라를 이용한 안면부 측정의 재현성과 정확도에 대한 마네킨을 이용한 연구: 직접 인체계측, Digitizer, Stereophotogrammetry의 비교 연구)

  • Jeoung, Youn-Wook;Yang, Ji-Woong;Chung, Kwang;Kook, Min-Suk;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.17-25
    • /
    • 2012
  • Purpose: Recently, a three dimensional approach to hard and soft tissues of the maxillofacial area has been widely used. This study was to evaluate the reproducibility and accuracy of a stereocamera compared to actual measurement methods using a digital caliper and digitizer. Methods: The stereoscopies of 7 head dummies with different sizes and shapes were obtained using a Di3D system (Dimensional Imaging, Glasgow, UK) after marking reference points on facial areas. From the obtained stereoscopy, 10 measurements representing the width, height and depth of each of the facial sections of the dummy were measured twice using a three dimensional reverse engineering software program (RapidForm$^{TM}$ 2006, Inus, Seoul, Korea). The x, y, and z coordinates of each of the three dimensional measurements were obtained and distances between two points were calculated. All procedures were repeated twice. The actual measurement method was performed twice, directly on dummies, using a digital caliper and values were compared with the previously determined values. Results: The results were as follows. In the ANOVA analysis, there were no significant statistical differences among the three measurement methods. In the Bonferroni analysis, with adjustments applied for multiple comparisons, there was no difference between actual measurement methods using a digitizer and a digital caliper. However, there was some difference between using a stereocamera and actual measurement methods using a digitizer and a digital caliper in values of $Ex_{Rt}-Ex_{Lt}$, $En_{Rt}-En_{Lt}$, $Ala_{Rt}-Ala_{Lt}$, $Ch_{Rt}-Ch_{Lt}$, G-Pg', $Ala_{Rt}$-Prn, $Ala_{Rt}$-Prn. The mean value for technical error in measurement (TEM) in Di3D (0.98 mm) was slightly higher than for a digital caliper (0.17 mm) and a digitizer (0.30 mm). In an intraclass correlation coefficient (ICC) there were no significant differences among the three measurement methods, but the Di3D system with the stereocamera showed relatively lower reproducibility compared to actual measurement methods using a digitizer and a digital caliper. Conclusion: These results indicate that some complementary measures may be needed to improve accuracy and reproducibility in the Di3D system with stereocamera.

Studies on the Indirect Measuring Method of the Maximum Voluntary Ventilation (최대환기능의 간접측정법에 관한 연구)

  • Park, Hae-Kun;Kim, Kwang-Jin;Sung, Hae-Sook;Jeon, Byung-Sook
    • The Korean Journal of Physiology
    • /
    • v.11 no.2
    • /
    • pp.45-50
    • /
    • 1977
  • The maximum voluntary ventilation (MVV) is one of the most widely used pulmonary function test, but its measuring method was very difficult and unreliable. However, it is need to get more easy and simple measuring method of MVV. Therefore, this study was attempted to get more easy and simple measuring method of MVV by means of the forced expiratory volume $(FEV_{T})$. The young and healthy 1,000 Korean students(592 male and 408 female) were cheesed for this purpose and whose ages were from 8 to 20 years. A spirometer (9L, Collins Co.) was used for the MVV and FEV, and they were measured 3 times at standing position, and the highest value was used. In the measurements, the subjects for MVV were asked for the breath as fast and deeply as possible for 12 seconds, and for FEV were asked for the rapid and forceful exhalation after a maximal inhalation (forced expiratory curve). In the FEV measurements toward the end of the expiration, the subjects were exhaused to continue the effort until no further gas was expired. During these measurements, the investigator stood by the subject to give a constant encouragement. FEV were calculated in the volume exhaled during the one-half $(FEV_{0{\cdot}5,}\;ml)$, the first second $(FEV_{1{\cdot}0,}\;ml)$ and the percentage of the total vital capacity exhaled during the one-half second $(FEV_{0{\cdot}5,}\;%)$. The results are summarized as follows: 1) The values of MVV were increased linearly with ages until 20 in both sexes. The values of male at the age of 20 was $168.2{\pm}2.5L/min$, and female at the age of 17 was $112.3{\pm}3.0L/min$, respectively. 2) The values of FEV (ml) were increased linearly with ages until 20 in both sexes. The values of $FEV_{0{\cdot}5}$ were $2,797{\pm}65.7ml$ in the male of 20 years and were $2,088{\pm}54.6ml$ in the female of 17 years, and of $FEV_{1{\cdot}0$ were $4,119{\pm}68.2ml$ in the male of 20 years and were $2,897{\pm}65.9ml$ in the female of 17 years, respectively. 3) The correlation coefficients between MVV and $FEV_{0{\cdot}5}\;or\;FEV_{1{\cdot}0$ (ml) were 0.82 or 0.85 in the male, and 0.77 or 0.79 in the female, respectively. 4) The prediction formulae for MVV to be derived from above results were: For male: MVV (L/min) =7.19+$0.05{\times}FEV_{0\cdot5}(ml)$, MVV (L/min)=11.25+$0.04{\times}FEV_{1\cdot0}(ml)$ For female: MVV (L/min)=16.03+$0.05{\times}FEV_{0\cdot5}(ml)$, MVV (L/min)=9.47+$0.03{\times}FEV_{1\cdot0}(ml)$.

  • PDF