• 제목/요약/키워드: rank order filter

검색결과 16건 처리시간 0.027초

Kalman filter를 이용한 생체신호의 AR modelling (AR modelling for a biomedical signal using Kalman filter)

  • 김대근;박해정;지영준;박광석;이충웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.184-187
    • /
    • 1997
  • In terms of a system identification, we present a method for autoregressive(AR) modelling of variious biomedical signal. Model order is estimated fly low rank approximation and coefficients are determined by innovation processes of Kalman filter derivation. An application of the method is given for visual evoked potentials.

  • PDF

Generalized Directional Morphological Filter Design for Noise Removal

  • Jinsung Oh;Heesoo Hwang;Changhoon Lee;Younam Kim
    • KIEE International Transaction on Systems and Control
    • /
    • 제2D권2호
    • /
    • pp.115-119
    • /
    • 2002
  • In this paper we present a generalized directional morphological filtering algorithm for the removal of impulse noise, which is based on a combination of impulse noise detection and a weighted rank-order morphological filtering technique. For salt (or pepper) noise suppression, the generalized directional opening (or closing) filtering of the input signal is selectively used. The detection of impulse noise can be done by the geometrical difference of opening and closing filtering. Simulations show that this new filter has better detail feature preservation with effective noise reduction compared to other nonlinear filtering techniques.

  • PDF

Pupil Detection using PCA and Hough Transform

  • Jang, Kyung-Shik
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권2호
    • /
    • pp.21-27
    • /
    • 2017
  • In this paper, we propose a pupil detection method using PCA(principal component analysis) and Hough transform. To reduce error to detect eyebrows as pupil, eyebrows are detected using projection function in eye region and eye region is set to not include the eyebrows. In the eye region, pupil candidates are detected using rank order filter. False candidates are removed by using symmetry. The pupil candidates are grouped into pairs based on geometric constraints. A similarity measure is obtained for two eye of each pair using PCA and hough transform, we select a pair with the smallest similarity measure as final two pupils. The experiments have been performed for 1000 images of the BioID face database. The results show that it achieves the higher detection rate than existing method.

An improved extended Kalman filter for parameters and loads identification without collocated measurements

  • Jia He;Mengchen Qi;Zhuohui Tong;Xugang Hua;Zhengqing Chen
    • Smart Structures and Systems
    • /
    • 제31권2호
    • /
    • pp.131-140
    • /
    • 2023
  • As well-known, the extended Kalman filter (EKF) is a powerful tool for parameter identification with limited measurements. However, traditional EKF is not applicable when the external excitation is unknown. By using least-squares estimation (LSE) for force identification, an EKF with unknown input (EKF-UI) approach was recently proposed by the authors. In this approach, to ensure the influence matrix be of full column rank, the sensors have to be deployed at all the degrees-of-freedom (DOFs) corresponding to the unknown excitation, saying collocated measurements are required. However, it is not easy to guarantee that the sensors can be installed at all these locations. To circumvent this limitation, based on the idea of first-order-holder discretization (FOHD), an improved EKF with unknown input (IEKF-UI) approach is proposed in this study for the simultaneous identification of structural parameters and unknown excitation. By using projection matrix, an improved observation equation is obtained. Few displacement measurements are fused into the observation equation to avoid the so-called low-frequency drift. To avoid the ill-conditioning problem for force identification without collocated measurements, the idea of FOHD is employed. The recursive solution of the structural states and unknown loads is then analytically derived. The effectiveness of the proposed approach is validated via several numerical examples. Results show that the proposed approach is capable of satisfactorily identifying the parameters of linear and nonlinear structures and the unknown excitation applied to them.

IHP 알고리즘을 이용한 SIMO 시스템용 적응 직접 결정 등화기 연구 (An Adaptive Decision-Directed Equalizer using Iterative Hyperplane Projection for SIMO systems)

  • 이원철
    • 한국통신학회논문지
    • /
    • 제30권1C호
    • /
    • pp.82-91
    • /
    • 2005
  • 본 논문은 iterative hyperplane projection 을 이용한 효율적인 APA(affine projection algorithm)을 소개한다. 다양한 적응 알고리즘들 중 APA는 랭크 부족 문제를 해결하며 고속 수렴의 특성 때문에 다양한 응용분야에 적용되고 있다. SIMO(Single-Input-Multiple-Output) 시스템을 위한 STDE(Space-Time Decision- directed Equalizer) 적용 시 흔히 단일 채널 환경에서 발생하는 "shifting invariance property"를 이용할 수 없으므로 인해 FTF(Fast Transversal Filter)와 같이 저 복잡도를 갖는 고속 적응 알고리즘을 사용할 수 없다. 따라서 APA 기반의 STDE 기능을 수행하는 과정에서 SMI(Sample Matrix Inversion) 처리가 불가피하며, 계산상의 복잡도가 증가하게 된다. 이러한 문제점을 해결하고자 본 논문에서는 APA 기법 고유의 우수한 추적 특성 및 고속 수렴 성질을 유지하면서, 낮은 복잡도를 갖는 IHP(Iterative Hyperplane Projection) 알고리즘 기반의 효율적인 수정 APA 기법을 소개한다. 제안된 IHP 기반 APA 기법의 성능을 확인하기 위하여, 무선 SIMO 채널 환경 하에서 제안된 IHP-APA 알고리즘을 적용한 STED에 대한 비트 에러 오률 (BER) 특성과 계산량 분석을 통해서 우수성을 입증하였다.

PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가 (Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT)

  • 이충운;유연욱;문종운;김윤철
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF